Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TEMPERATURE PROFILE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Stratospheric NO and NO2 Abundances from ATMOS Solar-Occultation Measurements

Using results from a time-dependent photochemical model to calculate the diurnal variation of NO and NO2, we have corrected Atmospheric Trace MOlecule Spectroscopy (ATMOS) solar-occultation retrievals of the NO and NO2 abundances at 90' solar zenith angle. Neglecting to adjust for the rapid variation of these gases across the terminator results in potential errors in retrieved profiles of approximately 20% for NO2 and greater than 100% for NC at altitudes below 25 km. Sensitivity analysis indicates that knowledge of the local 03 and temperature profiles, rather than zonal mean or climatological conditions of these quantities, is required to obtain reliable retrievals of NO and NO2 in the lower stratosphere. Extremely inaccurate 03 or temperature values at 20 km can result in 50% errors in retrieved NO or NO2. Mixing ratios of NO in the mid-latitude, lower stratosphere measured by ATMOS during the November 1994 ATLAS-3 mission compare favorably with in situ ER-2 observations, providing strong corroboration of the reliability of the adjusted space-borne measurements.

Newchurch, M. J.↗

Integral LOCA fragmentation test on high-burnup fuel

Increasing the fuel burnup limit in light water reactors is sought to enhance fuel cycle economics and requires establishing a technical basis. Experimental observations of severe fuel fragmentation under loss-of-coolant-accident conditions at Halden and Studsvik had raised the need for additional considerations during the development of this technical basis. These test data suggested that the burnup threshold for high burnup fuel fragmentation may be influenced by pre-transient power. Additional loss-of-coolant-accident test data is therefore valuable to complement these tests and enhance the current state of understating. Oak Ridge National Lab has developed the Severe Accident Test Station capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident and beyond design basis accident scenarios. Severe Accident Test Station provides various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident testing, defueled oxidation quench testing, and high-temperature beyond design basis accident testing. Severe Accident Test Station has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory at Oak Ridge National Lab. Furthermore, descriptions of the in-cell re-fabrication capabilities and assembly of the loss-of-coolant-accident test train are provided. Installation of the Severe Accident Test Station system and in-cell re-fabrication restores United States capability to examine postulated and extended loss-of-coolant-accident conditions on spent fuel and cladding and provides a platform for evaluating advanced fuel and accident-tolerant fuel cladding concepts. Lastly, three in-cell integral loss-of-coolant-accident test were performed in the Severe Accident Test Station and compared to the Nuclear Regulatory Commission sponsored loss-of-coolant-accident test as well as the original loss-of-coolant-accident test performed at Argonne National Lab. Finally, the results of these tests as well as all publicly available integral loss-of-coolant-accident test were used to validate a threshold for high burnup fuel fragmentation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Kinetic-ballooning-limited pedestals in spherical tokamak plasmas

Abstract A theoretical model is presented that for the first time matches experimental measurements of the pedestal width-height Diallo scaling in the low-aspect-ratio high- β tokamak NSTX. Combining linear gyrokinetics with self-consistent pedestal equilibrium variation, kinetic-ballooning, rather than ideal-ballooning plasma instability, is shown to limit achievable confinement in spherical tokamak pedestals. Simulations are used to find the novel Gyrokinetic Critical Pedestal constraint, which determines the steepest pressure profile a pedestal can sustain subject to gyrokinetic instability. Gyrokinetic width-height scaling expressions for NSTX pedestals with varying density and temperature profiles are obtained. These scalings for STs depart significantly from that of conventional aspect ratio tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrasonic Measurements of Temperature Distribution in Extreme Environments: Results of Power Plant Testing

The most hardened insertion sensors do not perform reliably in extreme environmental conditions. We address this problem by developing an ultrasonic thermometry system for the measurements of segmental temperature distributions (MSTD) in solid materials and, specifically, across containments of energy conversion processes. The MSTD approach uses an echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features. In pulse-echo mode, these features produce a train of echoes in response to an external pulse of ultrasonic excitation created and acquired by a transducer located outside the extreme environment. The delays between the echoes encode the information on the temperature distribution in the corresponding segments of the ultrasonic propagation path, which we use to reconstruct an unknown temperature profile. This note describes the preliminary results and initial experience in applying the developed MSTD ultrasonic thermometry system to the measurements of temperatures in a utility-scale 500MW coal-fired boiler.

John, Mason↗

Hot Cell Installation and Demonstration of the Severe Accident Test Station

A Severe Accident Test Station (SATS) capable of examining the oxidation kinetics and accident response of irradiated fuel and cladding materials for design basis accident (DBA) and beyond design basis accident (BDBA) scenarios has been successfully installed and demonstrated in the Irradiated Fuels Examination Laboratory (IFEL), a hot cell facility at Oak Ridge National Laboratory. The two test station modules provide various temperature profiles, steam, and the thermal shock conditions necessary for integral loss of coolant accident (LOCA) testing, defueled oxidation quench testing and high temperature BDBA testing. The installation of the SATS system restores the domestic capability to examine postulated and extended LOCA conditions on spent fuel and cladding and provides a platform for evaluation of advanced fuel and accident tolerant fuel (ATF) cladding concepts. This document reports on the successful in-cell demonstration testing of unirradiated Zircaloy-4. It also contains descriptions of the integral test facility capabilities, installation activities, and out-of-cell benchmark testing to calibrate and optimize the system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Laboratory Testing of the Temperature Sensor Qualification Device

The Temperature sensor Qualification Device (TQD) has been developed and tested under laboratory conditions to evaluate its thermal performance and the reliability of its retractable sensor system. The TQD is designed to provide an isothermal environment for temperature sensors in both test and reference zones during irradiation experiments. Initial testing revealed minimal radial and azimuthal temperature variations but identified a significant axial gradient. To address this, design modifications were implemented, including enhanced insulation and the addition of a small heater at the device's top. These changes are expected to produce a more uniform axial temperature profile, though further testing is recommended prior to irradiation. The retractable sensor mechanism was rigorously tested, achieving 1,350 cycles at room temperature and 332 cycles at 400°C before failure. The primary failure mechanism was the thermocouple becoming stuck in the wire guide or capillary tube. Based on these results, design improvements were proposed, such as incorporating a load cell for force monitoring and a stepper motor for precise sensor positioning.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermoelectric thin film thermal coating systems

Derivation of the fluid loop temperature profile for a model with thermoelectric devices (TED) attached is developed as a function of position, incident radiation intensity, input fluid loop temperature and TED current. The associated temperature of the radiator is also developed so that the temperature difference across the TED can be determined for each position. The temperature difference is used in determining optimum operating conditions and available generated electrical power.

Harpster, J. W.↗

Apparent solar temperature enhancement due to large-amplitude waves

The effect of slow-mode acoustic-type MHD waves propagating outward in the solar atmosphere on the temperature structures predicted by empirical models is investigated analytically. A model is constructed, and numerical results are presented for wing intensities, line profiles, temperature enhancements, waves with higher energy flux, temperature depression, and the Si continuum. The flux in the MgII and CaII UV resonance lines is found to be increased relative to that in the IR continuum, leading to model temperatures which depend systematically on which observations are used in the computation. It is suggested that mechanical heating may take place in smaller regions such as flux tubes rather than uniformly over the surface.

Kalkofen, W.↗

Growth and characterization of CdS crystals

A growth method for the physical vapor transport of compound semiconductors in closed ampoules is described. With the unique techniques applied in the heat treatment of the starting materials and the temperature profiles provided by the three-zone translational furnace, large crystals of CdS have been grown successfully by the method at lower temperatures than previously used. Both unseeded and seeded growth have been investigated. The CdS crystals were examined using optical and scanning electron microscopies (SEM) to study the microstructure and the dislocation etch-pits. The crystals were further characterized by infrared (IR) and ultraviolet (UV) transmission measurements.

Su, Ching-Hua↗

Comparisons of peak ionosphere pressures at Mars and Venus with incident solar wind dynamic pressure

Radio occultation measurements of electron density profiles from Mariner 6 and 7, the Mariner 9 extended mission, and the U.S. Viking orbiters, together with model ion and electron temperature profiles, are used to derive thermal pressure profiles in the Mars ionosphere. The comparison of the Mars peak ionosphere pressure with the incident solar and dynamic pressure suggests that at solar maximum the Mars ionosphere, like that of Venus, should generally be sufficient to balance the incident solar wind pressure. At solar minimum, when the ionosphere is weakest and the solar wind dynamic pressure is highest, only the peak pressures at high solar zenith angles (SZAs) at Mars appear to be strong enough to balance the incident solar wind pressure. This is similar to the situation at Venus at solar minimum.

Zhang, M. H. G.↗

Investigation of radiative interaction in laminar flows using Monte Carlo simulation

The Monte Carlo method (MCM) is employed to study the radiative interactions in fully developed laminar flow between two parallel plates. Taking advantage of the characteristics of easy mathematical treatment of the MCM, a general numerical procedure is developed for nongray radiative interaction. The nongray model is based on the statistical narrow band model with an exponential-tailed inverse intensity distribution. To validate the Monte Carlo simulation for nongray radiation problems, the results of radiative dissipation from the MCM are compared with two available solutions for a given temperature profile between two plates. After this validation, the MCM is employed to solve the present physical problem and results for the bulk temperature are compared with available solutions. In general, good agreement is noted and reasons for some discrepancies in certain ranges of parameters are explained.

Liu, Jiwen↗

Thermal Stability of RP-2 for Hydrocarbon Boost Regenerative Cooling

A series of tests were performed in the NASA Glenn Research Centers Heated Tube Facility to study the heat transfer and thermal stability behavior of RP-2 under conditions similar to those found in rocket engine cooling channels. It has long been known that hydrocarbon fuels, such as RP-2, can decompose at high temperature to form deposits (coke) which can adversely impact rocket engine cooling channel performance. The heated tube facility provides a simple means to study these effects. Using resistively heated copper tubes in a vacuum chamber, flowing RP-2 was heated to explore thermal effects at a range of test conditions. Wall temperature (850-1050F) and bulk fluid temperature (300-500F) were varied to define thermal decomposition and stability at each condition. Flow velocity and pressure were fixed at 75 fts and 1000 psia, respectively. Additionally, five different batches of RP-2 were tested at identical conditions to examine any thermal stability differences resulting from batch to batch compositional variation. Among these tests was one with a potential coke reducing additive known as 1,2,3,4-Tetrahydroquinoline (THQ). While copper tubes were used for the majority of tests, two exploratory tests were performed with a copper alloy known as GRCop-42. Each tube was instrumented with 15 thermocouples to examine the temperature profile, and carbon deposition at each thermocouple location was determined post-test in an oxidation furnace. In many tests, intermittent local temperature increases were observed visually and in the thermocouple data. These hot spots did not appear to correspond with a higher carbon deposition.

Kleinhenz, Julie E.↗

Thermal Analysis for Ion-Exchange Column System

Models have been developed to simulate the thermal characteristics of crystalline silicotitanate ion exchange media fully loaded with radioactive cesium either in a column configuration or distributed within a waste storage tank. This work was conducted to support the design and operation of a waste treatment process focused on treating dissolved, high-sodium salt waste solutions for the removal of specific radionuclides. The ion exchange column will be installed inside a high level waste storage tank at the Savannah River Site. After cesium loading, the ion exchange media may be transferred to the waste tank floor for interim storage. Models were used to predict temperature profiles in these areas of the system where the cesium-loaded media is expected to lead to localized regions of elevated temperature due to radiolytic decay. Normal operating conditions and accident scenarios (including loss of solution flow, inadvertent drainage, and loss of active cooling) were evaluated for the ion exchange column using bounding conditions to establish the design safety basis. The modeling results demonstrate that the baseline design using one central and four outer cooling tubes provides a highly efficient cooling mechanism for reducing the maximum column temperature. In-tank modeling results revealed that an idealized hemispherical mound shape leads to the highest tank floor temperatures. In contrast, even large volumes of CST distributed in a flat layer with a cylindrical shape do not result in significant floor heating.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of Spatial Discretization on Reactivity Biases in Depleted TRIGA Fuel

Ongoing work at Kansas State University (KSU) and the University of Wisconsin involves the determination of fuel compositions in TRIGA reactors. Modeling of depletion requires a number of approximations to be made, which often includes selection of an appropriate spatial discretization for tracking material evolution in time. Incorporation of temperature feedback also requires such spatial zoning. Any approximation made leads to computational biases, i.e., differences between computed and accurate values of some parameter of interest. The objective of this study is to understand the potential magnitude of biases introduced by the selected spatial discretization. Specifically, biases in the reactivity of a square-pitch unit cell representative of a typical TRIGA fuel element were studied as a function of burnup for different radial and axial discretizations. Temperature effects were also studied by introducing a fixed, radial temperature profile. The results indicate a very fine radial discretization (> 10 radial regions) may be needed to eliminate biases (of statistical significance) from temperature feedback effects, while an axial discretization of {approx_equal}7 regions may be sufficient to eliminate biases due to evolution of the fuel composition. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Status of the Microwave Barometric Radar and Sounder (MBARS)

Atmospheric surface pressure and pressure profiles are essential variables in weather modeling and forecasting. Pressure gradients generate atmospheric motion and are essential to the air-sea heat exchange feedbacks within the planetary boundary layer (PBL) that lead to convective storms and heavy precipitation. Despite the importance of pressure and pressure gradients on meso-, synoptic-, and global-scale weather patterns, current technology relies almost entirely on buoy measurements over the majority of the ocean. These measurements are too sparse to capture pressure gradients of even many synoptic scale events, and leave models starved of information. NASA/Goddard Space Flight Center (GSFC), NASA/Langley Research Center (LaRC), and Tomorrow.io have begun development of the Microwave Barometric Radar and Sounder (MBARS), an airborne sensor to retrieve surface air pressure and vertical pressure profiles, especially over oceans. MBARS is a new combined active/passive microwave instrument in the O2 absorption V-band (64-70 GHz) funded by the NASA Earth Science Technology Office (ESTO) Instrument Incubator Program (IIP). This instrument consists of an innovative scanning multi-channel differential absorption radar (DAR) to provide an estimation of total atmospheric column oxygen content and thus the surface dry air pressure. MBARS also will provide hyperspectral radiometric temperature profiling to enables vertical pressure profiles using the hypsometric relationship between pressure and temperature. A co-located microwave radiometer will provide the integrated water vapor mass contribution to atmospheric pressure. This presentation will summarize the project, retrieval concept, and engineering status of the MBARS project.

Radar, Radiometer↗

Sensitivities of Modeled Tropical Cyclones to Surface Friction and the Coriolis Parameter

In this investigation the sensitivities of a 2-D tropical cyclone (TC) model to surface frictional coefficient and the Coriolis parameter are studied and their implication is discussed. The model used is an axisymmetric version of the latest version of the Goddard cloud ensemble model. The model has stretched vertical grids with 33 levels varying from 30 m near the bottom to 1140 m near the top. The vertical domain is about 21 km. The horizontal domain covers a radius of 962 km (770 grids) with a grid size of 1.25 km. The time step is 10 seconds. An open lateral boundary condition is used. The sea surface temperature is specified at 29C. Unless specified otherwise, the Coriolis parameter is set at its value at 15 deg N. The Newtonian cooling is used with a time scale of 12 hours. The reference vertical temperature profile used in the Newtonian cooling is that of Jordan. The Newtonian cooling models not only the effect of radiative processes but also the effect of processes with scale larger than that of TC. Our experiments showed that if the Newtonian cooling is replaced by a radiation package, the simulated TC is much weaker. The initial condition has a temperature uniform in the radial direction and its vertical profile is that of Jordan. The initial winds are a weak Rankin vortex in the tangential winds superimposed on a resting atmosphere. The initial sea level pressure is set at 1015 hPa everywhere. Since there is no surface pressure perturbation, the initial condition is not in gradient balance. This initial condition is enough to lead to cyclogenesis, but the initial stage (say, the first 24 hrs) is not considered to resemble anything observed. The control experiment reaches quasi-equilibration after about 10 days with an eye wall extending from 15 to 25 km radius, reasonable comparing with the observations. The maximum surface wind of more than 70 m/s is located at about 18 km radius. The minimum sea level pressure on day 10 is about 886 hPa. Thus the overall simulation is considered successful and the model is considered adequate for our investigation.

Chao, Winston C.↗

A model of devolatilization behavior in lignite pyrolysis with solid heat carriers

To elucidate the influence of the process conditions on pyrolytic products, the interactions between transport phenomena and pyrolysis kinetics are quantitatively analyzed at the level of a single coal particle. A comprehensive mathematical model is formulated to predict intraparticle multiphysics and devolatilization behaviors; the model contains two correlative one–dimensional unsteady heat conservation equations and ternary mass conservation equations in conjunction with the simplified dusty–gas model. Moreover, a multistep kinetic model of coal devolatilization is adopted to predict the generating rates of the lumped pyrolytic products. Validation of the model against experimental and literature data showed that can predict the transient temperature profiles of a coal particle and the yields of volatiles. Finally, the effects of the main process conditions on the intra– and extra–temperature history of lignite during pyrolysis with solid heat carriers are analyzed. Here, the interactions between physical transport and the pyrolysis reaction are also examined.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Nonlinear Optimal Control Problem Arising from a Sterilization Process for Packaged Foods

In this paper we study an optimization problem arising from a sterilization process for packaged foods by using a microwave heating method. The goal of the optimal control is to find the optimal frequency function such that the temperature profile at the final stage has a relative uniform distribution in the food product. The underlying state variables are electric, magnetic fields and temperature which satisfy the coupled nonlinear Maxwell’s system and a nonlinear heat equation. The control variable for the system is chosen to be the electric frequency function. We show that there exists an optimal frequency which minimizes the cost functional. Moreover, an optimality condition is also derived.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗