Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Systems Integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Flexible Electronics toward Wearable Sensing

Wearable sensors play a crucial role in realizing personalized medicine, as they can continuously collect data from the human body to capture meaningful health status changes in time for preventive intervention. However, motion artifacts and mechanical mismatches between conventional rigid electronic materials and soft skin often lead to substantial sensor errors during epidermal measurement. Because of its unique properties such as high flexibility and conformability, flexible electronics enables a natural interaction between electronics and the human body. Here, we summarize our recent studies on the design of flexible electronic devices and systems for physical and chemical monitoring. Material innovation, sensor design, device fabrication, system integration, and human studies employed toward continuous and noninvasive wearable sensing are discussed. A flexible electronic device typically contains several key components, including the substrate, the active layer, and the interface layer. The inorganic-nanomaterials-based active layer (prepared by a physical transfer or solution process) is shown to have good physicochemical properties, electron/hole mobility, and mechanical strength. Flexible electronics based on the printed and transferred active materials has shown great promise for physical sensing. For example, integrating a nanowire transistor array for the active matrix and a conductive pressure-sensitive rubber enables tactile pressure mapping; tactile-pressure-sensitive e-skin and organic light-emitting diodes can be integrated for instantaneous pressure visualization. Such printed sensors have been applied as wearable patches to monitor skin temperature, electrocardiograms, and human activities. In addition, liquid metals could serve as an attractive candidate for flexible electronics because of their excellent conductivity, flexibility, and stretchability. Liquid-metal-enabled electronics (based on liquid-liquid heterojunctions and embedded microchannels) have been utilized to monitor a wide range of physiological parameters (e.g., pulse and temperature). Despite the rapid growth in wearable sensing technologies, there is an urgent need for the development of flexible devices that can capture molecular data from the human body to retrieve more insightful health information. We have developed a wearable and flexible sweat-sensing platform toward real-time multiplexed perspiration analysis. An integrated iontophoresis module on a wearable sweat sensor could enable autonomous and programmed sweat extraction. A microfluidics-based sensing system was demonstrated for sweat sampling, sensing, and sweat rate analysis. Roll-to-roll gravure printing allows for mass production of high-performance flexible chemical sensors at low cost. These wearable and flexible sweat sensors have shown great promise in dehydration monitoring, cystic fibrosis diagnosis, drug monitoring, and noninvasive glucose monitoring. Future work in this field should focus on designing robust wearable sensing systems to accurately collect data from the human body and on large-scale human studies to determine how the measured physical and chemical information relates to the individual's specific health conditions. Further research in these directions, along with the large sets of data collected via these wearable and flexible sensing technologies, will have a significant impact on future personalized healthcare.

47 OTHER INSTRUMENTATION↗

Energy-Water Microgrid Opportunity Analysis at the University of Arizona's Biosphere 2 Facility

Microgrids provide reliable and cost-effective energy services in a variety of conditions and locations. There has been minimal effort invested in developing energy-water microgrids that demonstrate the feasibility and leverage synergies of operating renewable energy and water systems in a coordinated framework. Water systems can be operated in ways to provide ancillary services to the electrical grid and renewable energy can be utilized to power water-related infrastructure, but the potential for co-managed systems has not yet been quantified or fully characterized. Energy-water microgrids could be a promising solution to improve energy and water resource management for islands, rural communities, distributed generation, Defense operations, and many parts of the world lacking critical infrastructure. NREL and the University of Arizona have been jointly researching energy-water microgrid opportunities at the University's Biosphere 2 (B2) research facility. B2 is an ideal case study for an energy-water microgrid test site, given its size, its unique mission and operations, the criticality of water and energy infrastructure, and its ability to operate connected to or disconnected from the local electrical grid. Moreover, the B2 is a premier facility for undertaking agricultural research, providing an excellent opportunity to evaluate connections and tradeoffs at the food-energy-water nexus. In this study, NREL used the B2 facility as a case study for an energy-water microgrid test site, with the potential to catalyze future energy-water system integration research. The study identified opportunities for energy and water efficiency and estimated the sizes of renewable energy and storage systems required to meet remaining loads in a microgrid, identified dispatchable loads in the water system, and laid the foundation for an in-depth energy-water microgrid analysis. The foundational work performed at B2 serves a model that can be built upon for identifying relevant energy-water microgrid data, analytical requirements, and operational challenges associated with development of future energy-water microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Monitoring and Commissioning Verification Algorithms for CHP Systems

This document provides the algorithms for CHP system performance monitoring and commissioning verification (CxV). It starts by presenting system-level and component-level performance metrics, followed by descriptions of algorithms for performance monitoring and commissioning verification, using the metric presented earlier. Verification of commissioning is accomplished essentially by comparing actual measured performance to benchmarks for performance provided by the system integrator and/or component manufacturers. The results of these comparisons are then automatically interpreted to provide conclusions regarding whether the CHP system and its components have been properly commissioned and where problems are found, guidance is provided for corrections. A discussion of uncertainty handling is then provided, which is followed by a description of how simulations models can be used to generate data for testing the algorithms. A model is described for simulating a CHP system consisting of a micro-turbine, an exhaust-gas heat recovery unit that produces hot water, a absorption chiller and a cooling tower. The process for using this model for generating data for testing the algorithms for a selected set of faults is described. The next section applies the algorithms developed to CHP laboratory and field data to illustrate their use. The report then concludes with a discussion of the need for laboratory testing of the algorithms on a physical CHP systems and identification of the recommended next steps.

20 FOSSIL-FUELED POWER PLANTS↗

BENEFIT with Northeastern University: HVAC Hardware-in-the-Loop Experimental Testing of a Heat Pump and Air Conditioner

This dataset includes HVAC Hardware-in-the-Loop (HIL) experimental results for a single stage, SEER 16, HSPF 9.5, 3-ton single-speed air source heat pump with 15 kW of backup auxiliary heating tested in both cooling and heating mode, and a two stage, SEER 21, 2-ton central air conditioner tested in cooling mode for a set of outdoor temperatures and indoor setpoint temperatures. In addition to these tests, experimental tests focused on the operation of auxiliary heating for the heat pump for winter condition were also conducted. The laboratory experiments for transient testing of the heat pump and air conditioner were conducted using the two HIL systems in the Systems Performance Laboratory (SPL) at NREL’s Energy Systems Integration Facility (ESIF). Further information on laboratory design and capabilities of the SPL along with the architecture of HVAC HIL system can be found in: Sparn, B. F. 2018. Laboratory Resources and Techniques to Evaluate Smart Home Technology (No. NREL/CP-5500-71696). National Renewable Energy Laboratory (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy18osti/71696.pdf and the experimental setup and validation of HVAC HIL platform can be found in: Ramaraj, S. and Sparn, B. 2022. Validation of HVAC Hardware-In-the-Loop Simulation for Advanced Control Strategies in Smart Homes (No. NREL/CP-5500-82562). National Renewable Energy Lab (NREL), Golden, CO (United States). https://www.nrel.gov/docs/fy22osti/82562.pdf. These experimental results can be used to validate how we currently model the cycling behavior of heat pumps and air conditioners. Additionally, many demand response programs implement heat pump and air conditioner control by changing the thermostat set point – these data may also be used to verify our models for heat pump and air conditioner demand response control are implemented correctly. The Test_Matrix file describes all the indoor and outdoor test conditions for heat pump and air conditioner and the file names of data sets include information about the test conditions. A wide range of outdoor air temperatures were chosen to accommodate summer and winter conditions. In addition to operating the HVAC equipment with different outdoor temperatures, we also operate the system with different indoor temperature set points to represent different grid signals or different operating conditions. For cooling conditions, the baseline set point is 72°F. To represent Load Up signals, the setpoint is changed to 68°F. The Load Shed set point is 76°F. For heating conditions, the baseline set point was assumed to be 68°F. The Load add set point is 72°F and the Load shed set point is 64°F. The starting indoor temperature for cooling conditions was set ~2°F above the indoor setpoint temperature so that the equipment turned on quickly. Similarly, the initial indoor temperature was set ~2°F lower than setpoint for heating mode tests to ensure that heating began quickly. The return air temperature was assumed to be equal to the indoor setpoint temperature in all cases. The experimental data are sampled at 1-second intervals. The data from ecobee thermostat at 5-minute interval are resampled and added to the corresponding file. The content of each data set is as follows: • T_Return (C): Measured return air temperature [C] • T_Return_SP (C): Return air temperature setpoint from E+ model, sent to HIL [C] • T_Supply (C): Measured supply air temperature at evaporator outlet [C] • T_Outdoor (C): Measured outdoor air temperature [C] • T_Outdoor_SP (C): Outdoor air temperature setpoint from weather file, sent to HIL [C] • T_Indoor (C): Measured indoor air temperature [C] • T_Indoor_SP (C): Indoor air temperature setpoint from E+ model, sent to HIL [C] • Outdoor Unit Power (W): Measured power of the outdoor unit [W] • Indoor Unit Power (W): Measured power of the indoor unit [W] • Evaporator Airflow Rate (CFM): Measured evaporator or indoor unit airflow rate sent to E+ model [CFM] • Cooling/Heating Capacity (kW): Calculated cooling/heating capacity sent to E+ model [kW] • T_SP_Thermostat (C): Thermostat cooling/heating setpoint temperature [C] • T_Indoor_Thermostat (C): Thermostat indoor air temperature [C]

24 POWER TRANSMISSION AND DISTRIBUTION↗

Durability, Reliability and Safety of Energy Storage Systems

For grid modernization, energy storage systems play a critical role in reliability. There are many technical issues and barriers that need to be addressed to redefine the reliability issues in modern grid system integration with renewable and distributed energy resources. This presentation is to disseminate some existing reliability issues in the energy storage systems to paint a bigger picture of what needs to be addressed. This presentation is intended to define these issues before we strive for a solution.

25 ENERGY STORAGE↗

Integrated Thermal Energy Storage and Brayton Cycle Equipment Demonstration (Integrated TESTBED) Project Design Basis

The Integrated Thermal Energy Storage and Brayton cycle Equipment Demonstration (Integrated TESTBED) project seeks to retire commercial-scale risks associated with the design, integration,and operation of a supercritical carbon dioxide (sCO2) power cycle and concentrating solar power (CSP) thermal energy storage (TES) system. This requires an understanding of commercial-scale collector system transient impacts on the TES system, the dynamics of heat exchange from theTES to the power cycle, and the control and operation of the power cycle to accommodate various dispatch strategies. In order to retire these risks, Heliogen has proposed to construct a 5 MWe CSP demonstration facility based on directly heated particle and sCO2 technology. The receivers, primary heat exchanger, and power cycle will be deployed at a full commercial scale based on Heliogen’s modular plant architecture to ensure actual system integration risks are validated during design, construction, and operation. This work summarizes the design basis for the Integrated TESTBED project demonstration facility including a design target for capacity factor to support test operations, hours of storage, particle silo arrangement, centrifugal article receivers, a diffusion bonded particle-sCO2 heat exchanger, and a 5 MWe (net) integrally geared sCO2 recompression Brayton cycle.

14 SOLAR ENERGY↗

Idaho National Laboratory Integrated Safety Management System FY 2016 Effectiveness Review and Declaration Report

Idaho National Laboratory’s (INL’s) Integrated Safety Management System (ISMS) effectiveness review of fiscal year (FY) 2016 shows that INL has integrated management programs and safety elements throughout the oversight and operational activities performed at INL. The significant maturity of Contractor Assurance System (CAS) processes, as demonstrated across INL’s management systems and periodic reporting through the Management Review Meeting process, over the past two years has provided INL with current real-time understanding and knowledge pertaining to the health of the institution. INL’s sustained excellence of the Integrated Safety and effective implementation of the Worker Safety and Health Program is also evidenced by other external validations and key indicators. In particular, external validations include VPP, ISO 14001, DOELAP accreditation, and key Laboratory level indicators such as ORPS (number, event frequency and severity); injury/illness indicators such as Days Away, Restricted and Transfer (DART) case rate, back & shoulder metric and open reporting indicators, demonstrate a continuous positive trend and therefore improved operational performance over the last few years. These indicators are also reflective of the Laboratory’s overall organizational and safety culture improvement. Notably, there has also been a step change in ESH&Q Leadership actions that have been recognized both locally and complex-wide. Notwithstanding, Laboratory management continues to monitor and take action on lower level negative trends in numerous areas including: Conduct of Operations, Work Control, Work Site Analysis, Risk Assessment, LO/TO, Fire Protection, and Life Safety Systems, to mention a few. While the number of severe injury cases has decreased, as evidenced by the reduction in the DART case rate, the two hand injuries and the fire truck/ambulance accident were of particular concern. Aggressive actions continue in order to understand the causes and define actions needed to prevent similar injuries and accidents in the future. While our injury rate is not where we want it to be, it is not the only indicator that defines our ISMS program, safety culture, and efforts to be a continuous learning organization. When reviewing the entire year’s performance, and all areas that integrate ISMS principles and core functions, INL has an “effective” ISMS program that is continually improving.

99 GENERAL AND MISCELLANEOUS↗

Status Report on Thermal Extraction Modeling within HYBRID

Idaho National Laboratory continues to be at the forefront of advanced reactor systems and integrated energy systems (IES) research. The HYBRID modeling repository is the computational modeling repository used to evaluate potential IES configurations. To support IES analysis, it is necessary to develop models that can evaluate a range of thermal integration points within given energy conversion systems. This work includes as many technologies as possible anticipating that many technologies will be deployed to broadly reduce climate impacts of energy intensive processes. To provide this analysis, a new balance of plant model has been generated. This report will discuss progress on this new main model and discuss nominal conditions for the primary reactor types contained within HYBRID.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

ARIES/Flatirons Facility - Hydrogen System Capability Buildout

Under the "Advanced Research on Integrated Energy Systems" (ARIES) initiative, hydrogen system capabilities including a MW-scale electrolyzer, storage system, and MW-scale fuel cell generator will be designed and commissioned at NREL's Flatirons Campus. This hydrogen infrastructure will support H2@Scale goals by enabling integrated systems R&D to study the science of scaling for hydrogen energy systems. The system is designed with flexibility to provide a testbed to demonstrate systems integration, grid services, energy storage, direct renewable hydrogen production, and innovative end use applications (e.g. HD transportation, natural gas blending, etc.).

DIRECT ENERGY CONVERSION,HYDROGEN↗

ARIES / Flatirons Facility - Hydrogen System Capability Buildout

Under the "Advanced Research on Integrated Energy Systems" (ARIES) initiative, hydrogen system capabilities including a MW-scale electrolyzer, storage system, and MW-scale fuel cell generator will be designed and commissioned at NREL's Flatirons Campus. This hydrogen infrastructure will support H2@Scale goals by enabling integrated systems R&D to study the science of scaling for hydrogen energy systems.The system is designed with flexibility to provide a testbed to demonstrate systems integration, grid services, energy storage, direct renewable hydrogen production, and innovative end use applications (e.g. HD transportation, natural gas blending, etc.).

electrical grid↗

Keynote Address #2 - Scale-up of Chemical Looping Reactors: Practical Considerations and Design of Industrial Systems

Chemical looping technology is advancing toward large pilot-scale demonstrations. When scaling chemical looping reactors and chemical looping system integrated with steam generation issues of fuel distribution, thermal integration and modular operation must be considered in addition to sparing philosophy. The keynote addressed discusses a number of scaling issues unique to chemical looping systems.

20 FOSSIL-FUELED POWER PLANTS↗

Engineering photosynthetic organisms for the production of biohydrogen

Oxygenic photosynthetic organisms such as green algae are capable of absorbing sunlight and converting the chemical energy into hydrogen gas. This process takes advantage of the photosynthetic apparatus of these organisms which links water oxidation to H 2 production. Biological H 2 has therefore the potential to be an alternative fuel of the future and shows great promise for generating large scale sustainable energy. Microalgae are able to produce H 2 under light anoxic or dark anoxic condition by activating 3 different pathways that utilize the hydrogenases as catalysts. In this review, we highlight the principal barriers that prevent hydrogen production in green algae and how those limitations are being addressed, through metabolic and genetic engineering. We also discuss the major challenges and bottlenecks facing the development of future commercial algal photobiological systems for H 2 production. Lastly we provide suggestions for future strategies and potential new techniques to be developed towards an integrated system with optimized hydrogen production.

09 BIOMASS FUELS↗

SU-E-J-153: Reconstructing 4D Cone Beam CT Images for Clinical QA of Lung SABR Treatments

Purpose: To verify that the planned Primary Target Volume (PTV) and Internal Gross Tumor Volume (IGTV) fully enclose a moving lung tumor volume as visualized on a pre-SABR treatment verification 4D Cone Beam CT. Methods: Daily 3DCBCT image sets were acquired immediately prior to treatment for 10 SABR lung patients using the on-board imaging system integrated into a Varian TrueBeam (v1.6: no 4DCBCT module available). Respiratory information was acquired during the scan using the Varian RPM system. The CBCT projections were sorted into 8 bins offline, both by breathing phase and amplitude, using in-house software. An iterative algorithm based on total variation minimization, implemented in the open source reconstruction toolkit (RTK), was used to reconstruct the binned projections into 4DCBCT images. The relative tumor motion was quantified by tracking the centroid of the tumor volume from each 4DCBCT image. Following CT-CBCT registration, the planning CT volumes were compared to the location of the CBCT tumor volume as it moves along its breathing trajectory. An overlap metric quantified the ability of the planned PTV and IGTV to contain the tumor volume at treatment. Results: The 4DCBCT reconstructed images visibly show the tumor motion. The mean overlap between the planned PTV (IGTV) and the 4DCBCT tumor volumes was 100% (94%), with an uncertainty of 5% from the 4DCBCT tumor volume contours. Examination of the tumor motion and overlap metric verify that the IGTV drawn at the planning stage is a good representation of the tumor location at treatment. Conclusion: It is difficult to compare GTV volumes from a 4DCBCT and a planning CT due to image quality differences. However, it was possible to conclude the GTV remained within the PTV 100% of the time thus giving the treatment staff confidence that SABR lung treatements are being delivered accurately.

60 APPLIED LIFE SCIENCES↗

Advanced Hydrogen Compressor for Hydrogen Storage Integrated with a Powerplant

This report summarizes work performed by Siemens Energy (SE) to design, build and test an advanced hydrogen compressor stage suitable for use in a hydrogen electrolysis system integrated with a powerplant to achieve energy storage in the form of compressed hydrogen. As hydrogen utilization increases to achieve energy storage and decarbonization of a variety of industries, the need is growing for improved and more cost-effective hydrogen compression technologies. The counter-rotating compression stage concept demonstrated under this contract and presented in this report offers a novel approach to achieve significantly more head rise per stage of compression, resulting in the potential for decreased capital cost and footprint compared to current state of the art centrifugal compression technologies. This report includes details of the design, testing, results, and subsequent validation of aerodynamic performance predictions.

08 HYDROGEN↗

Alternate Retrieval A-105 Application Assessment Report

This report summarizes the historical development of the Confined Sluicing End Effector (CSEE) technology as well scarification technology. We also summarize the systems integration and deployment of that technology in the Gunite and Associated Tanks (GAAT) at the Oak Ridge Reservation where the retrieval system successfully removed the remaining sludge and heel in the eight tanks for tank closure and disposition. We also summarize the lessons learned from the deployment at Oak Ridge. Simulant development and testing have been key activities for any waste retrieval effort as many of the physical properties of the waste are unknown; therefore, this report discusses a bounding series of simulants that helps to reduce uncertainty for operations. These simulants have been developed for potential Hanford waste retrieval deployment. The potential key attributes for retrieval, based upon information provided by Washington River Protection Services (WRPS), of single-shell tank A-105 are discussed along with the potential application of CSEE technology to the challenges presented by the unique nature of A-105. These unique features include a major tear in the bottom of the tank, which necessitates technologies other than past practice sluicing to be deployed to prevent further intrusion of waste into the vadose zone. In addition, significant in-tank hardware makes A-105 particular challenging. However, there appear to be a number of parameters that should be investigated through additional testing or review of prior testing that may demonstrate the applicability of the CSEE technology to A-105. Testing of the Waste Retrieval End Effector (WREE), which was based on the original CSEE design, to demonstrate the ability to remove sludge and hardpan from Tank 241-C-106 will be reviewed to determine relevance to the Tank A-105 retrieval. There may be new requirements for the deployment system that accesses the tank with the CSEE because the tank bottom may not be flat, requiring the ability to maneuver the CSEE to maintain the appropriate stand-off distance from the CSEE and the tank bottom. Finally, we provide a set of recommendations, a set of task descriptions, and a range of estimated costs for a demonstration of the technology by the end of FY17. These tasks are summarized as: Complete system-level functional requirements; Procure or access the capacity to perform; Generate simulant development and simulant testing; Develop CSEE functionality; Develop demonstration plan; Perform demonstration; Analyze and document testing results; Perform project management and engineering.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ontology to guide scenario design to evaluate new technologies for control room modernization - 127

Modernization of nuclear power plants (NPPs) are introducing new human-system interface (HSI) technology that may have unanticipated impact on control room operations. Introduction of HSI thus requires careful evaluation and integrated system validation involving human-in-the-loop experiments with high-fidelity simulation and realistic scenarios. To support the technology evaluation in modernization of NPPs, this paper reports our research on constructing an 'scenario development ontology' for the nuclear industry. We conducted a literature review to produce a preliminary flow chart of the scenario development process and verified the flow chart through interviews with ten domain professionals. The interviews confirmed the key steps in the process flow chart and provided a compendium of approximately 100 scenario attributes, which were divided according to their relevance to HSI evaluation. The next step will be to conduct additional interviews to expand and generalize the ontology that can facilitate vendor and industry evaluation of current and future control room modernization projects. This ontology is particularly intended to facilitate vendor and industry evaluation of current and future control room modernization projects. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SETP CPV Technology, Session: CPV (Presentation)

This project supports the Solar America Initiative by: (1) Reducing LCOE through--Increased power output from cell, and avenues for lowering of cell cost--substrate recycling; and (2) Establishing reliability by--Determination of cell degradation mechanisms; Integration of design for reliability into future cell development; future-generation cell development; cell reliability; advanced modeling for cell-system integration; basic science supporting cell development; and industry study.

14 SOLAR ENERGY↗

Life cycle assessment of integrated waste management systems for alternative legacy scenarios of the London Olympic Park

Highlights: • Application of LCA in planning integrated waste management systems. • Environmental valuation of 3 legacy scenarios for the Olympic Park. • Hot-spot analysis highlights the importance of energy and materials recovery. • Most environmental savings are achieved through materials recycling. • Sensitivity analysis shows importance of waste composition and recycling rates. - Abstract: This paper presents the results of the life cycle assessment (LCA) of 10 integrated waste management systems (IWMSs) for 3 potential post-event site design scenarios of the London Olympic Park. The aim of the LCA study is to evaluate direct and indirect emissions resulting from various treatment options of municipal solid waste (MSW) annually generated on site together with avoided emissions resulting from energy, materials and nutrients recovery. IWMSs are modelled using GaBi v6.0 Product Sustainability software and results are presented based on the CML (v.Nov-10) characterisation method. The results show that IWMSs with advanced thermal treatment (ATT) and incineration with energy recovery have the lowest Global Warming Potential (GWP) than IWMSs where landfill is the primary waste treatment process. This is due to higher direct emissions and lower avoided emissions from the landfill process compared to the emissions from the thermal treatment processes. LCA results demonstrate that significant environmental savings are achieved through substitution of virgin materials with recycled ones. The results of the sensitivity analysis carried out for IWMS 1 shows that increasing recycling rate by 5%, 10% and 15% compared to the baseline scenario can reduce GWP by 8%, 17% and 25% respectively. Sensitivity analysis also shows how changes in waste composition affect the overall result of the system. The outcomes of such assessments provide decision-makers with fundamental information regarding the environmental impacts of different waste treatment options necessary for sustainable waste management planning.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗