Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Soft computing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Dynamic Modeling and Soil Mechanics for Path Planning of the Mars Exploration Rovers

To help minimize risk of high sinkage and slippage during drives and to better understand soil properties and rover terramechanics from drive data, a multidisciplinary team was formed under the Mars Exploration Rover project to develop and utilize dynamic computer-based models for rover drives over realistic terrains. The resulting system, named ARTEMIS (Adams-based Rover Terramechanics and Mobility Interaction System), consists of the dynamic model, a library of terramechanics subroutines, and the high-resolution digital elevation maps of the Mars surface. A 200-element model of the rovers was developed and validated for drop tests before launch, using Adams dynamic modeling software. The external library was built in Fortran and called by Adams to model the wheel-soil interactions include the rut-formation effect of deformable soils, lateral and longitudinal forces, bull-dozing effects, and applied wheel torque. The paper presents the details and implementation of the system. To validate the developed system, one study case is presented from a realistic drive on Mars of the Opportunity rover. The simulation results match well from the measurement of on-board telemetry data. In its final form, ARTEMIS will be used in a predictive manner to assess terrain navigability and will become part of the overall effort in path planning and navigation for both Martian and lunar rovers.

rover↗

Feasibility of an image planning system for kilovoltage image-guided radiation therapy

Purpose: Image guidance has become a standard of care for many treatment scenarios in radiation therapy. This is most typically accomplished by use of kV x-ray devices mounted onto the linear accelerator (Linac) gantry that yield planar, fluoroscopic, and cone-beam computed tomography (CBCT) images. Image acquisition parameters are chosen via preset techniques that rely on broad categorizations in patient anatomy and imaging goal. However, the optimal imaging technique results in detectability of the features of interest while exposing the patient to minimum dose. Herein, the authors present an investigation into the feasibility of developing an image planning system (IPS) for radiotherapy.Methods: In this first phase, the authors focused on developing an algorithm to predict tissue contrast produced by a common radiotherapy planar imaging chain. Input parameters include a CT dataset and simulated planar imaging technique settings that include kV and mAs. Energy-specific attenuation through each voxel of the CT dataset was calculated in the algorithm to derive a net transmitted intensity. The response of the flat panel detector was integrated into the image simulation algorithm. Verification was conducted by comparing simulated and measured images using four phantoms. Comparisons were made in both high and low contrast settings, as well as changes in the geometric appearance due to image saturation. Results: The authors studied a lung nodule test object to assess the planning system's ability to predict object contrast and detectability. Verification demonstrated that the slope of the pixel intensities is similar, the presence of the nodule is evident, and image saturation at high mAs values is evident in both images. The appearance of the lung nodule is a function of the image detector saturation. The authors assessed the dimensions of the lung nodule in measured and simulated images. Good quantitative agreement affirmed the algorithm's predictive capabilities. The invariance of contrast with kVp and mAs prior to saturation was predicted, as well as the gradual loss of object detectability as saturation was approached. Small changes in soft tissue density were studied using a mammography step wedge phantom. Data were acquired at beam qualities of 80 and 120 kVp and over exposure values ranging from 0.04 to 500 mAs. The data showed good agreement in terms of the absolute value of pixel intensities predicted, as well as small variations across the step wedge pattern. The saturation pixel intensity was consistent between the two beam qualities studied. Boney tissue contrast was assessed using two abdominal phantoms. Measured and calculated values agree in terms of predicting the mAs value at which detector saturation, and subsequent loss of contrast occurs. The lack of variation in contrast over mAs values lower than 10 suggests that there is wide latitude for minimizing patient dose. Conclusions: The authors developed and tested an algorithm that can be used to assist in kV imaging technique selection during localization for radiotherapy. Phantom testing demonstrated the algorithm's predictive accuracy for both low and high contrast imaging scenarios. Detector saturation with subsequent loss of imaging detail, both in terms of object size and contrast were accurately predicted by the algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-petascale highly efficient parallel supercomputer

A Multi-Petascale Highly Efficient Parallel Supercomputer of 100 petaflop-scale includes node architectures based upon System-On-a-Chip technology, where each processing node comprises a single Application Specific Integrated Circuit (ASIC). The ASIC nodes are interconnected by a five dimensional torus network that optimally maximize the throughput of packet communications between nodes and minimize latency. The network implements collective network and a global asynchronous network that provides global barrier and notification functions. Integrated in the node design include a list-based prefetcher. The memory system implements transaction memory, thread level speculation, and multiversioning cache that improves soft error rate at the same time and supports DMA functionality allowing for parallel processing message-passing.

97 MATHEMATICS AND COMPUTING↗

Quantifying local and global mass balance errors in physics-informed neural networks

Physics-informed neural networks (PINN) have recently become attractive for solving partial differential equations (PDEs) that describe physics laws. By including PDE-based loss functions, physics laws such as mass balance are enforced softly in PINN. This paper investigates how mass balance constraints are satisfied when PINN is used to solve the resulting PDEs. We investigate PINN’s ability to solve the 1D saturated groundwater flow equations (diffusion equations) for homogeneous and heterogeneous media and evaluate the local and global mass balance errors. We compare the obtained PINN’s solution and associated mass balance errors against a two-point finite volume numerical method and the corresponding analytical solution. We also evaluate the accuracy of PINN in solving the 1D saturated groundwater flow equation with and without incorporating hydraulic heads as training data. We demonstrate that PINN’s local and global mass balance errors are significant compared to the finite volume approach. Tuning the PINN’s hyperparameters, such as the number of collocation points, training data, hidden layers, nodes, epochs, and learning rate, did not improve the solution accuracy or the mass balance errors compared to the finite volume solution. Mass balance errors could considerably challenge the utility of PINN in applications where ensuring compliance with physical and mathematical properties is crucial.

54 ENVIRONMENTAL SCIENCES↗

Quantifying local rearrangements in three-dimensional granular materials: Rearrangement measures, correlations, and relationship to stresses

Quantifying the ways in which local particle rearrangements contribute to macroscopic plasticity is one of the fundamental pursuits of granular mechanics and soft matter physics. Here we examine local rearrangements that occur naturally during the deformation of three samples of 3D granular materials subjected to distinct boundary conditions by employing in situ x-ray measurements of particle-resolved structure and stress. We focus on five distinct rearrangement measures, their statistics, interrelationships, contributions to macroscopic deformation, repeatability, and dependence on local structure and stress. Our most significant findings are that local rearrangements (1) are correlated on a scale of three to four particle diameters, (2) exhibit volumetric strain-shear strain and nonaffine displacement-rotation coupling, (3) exhibit correlations that suggest either rearrangement repeatability or that rearrangements span multiple steps of incremental sample strain, and (4) show little dependence on local stress but correlate with quantities describing local structure, such as porosity. Our results are presented in the context of relevant plasticity theories and are consistent with recent findings suggesting that local structure may play at least as important of a role as local stress in determining the nature of local rearrangements.

58 GEOSCIENCES↗

Library based x-ray scatter correction for dedicated cone beam breast CT

Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal views. Conclusions: The library-based scatter correction does not require increase in radiation dose or hardware modifications, and it improves over the existing methods on implementation simplicity and computational efficiency. As demonstrated through patient studies, the authors’ approach is effective and stable, and is therefore clinically attractive for CBBCT imaging.

60 APPLIED LIFE SCIENCES↗

Material Needs and Measurement Challenges for Advanced Semiconductor Packaging: Understanding the Soft Side of Science

This Perspective builds upon insights from the National Institute of Standards and Technology (NIST)-organized workshop, “Materials and Metrology Needs for Advanced Semiconductor Packaging Strategies,” held at the 35th annual Electronics Packaging Symposium in Binghamton, NY, on September 5, 2024. It outlines critical challenges and opportunities related to polymer-based “soft” materials in advanced semiconductor packaging, with emphasis on polymer science, measurement science (metrology), and the strategic development of Research-Grade Test Materials (RGTMs). These efforts, led by the NIST CHIPS team, aim to advance the fundamental understanding of structure-property-processing relationships, promote standardized guidelines and innovative methods for material characterization, and accelerate the development, qualification, and adoption of next-generation packaging materials. The Perspective also distills key insights from the panel discussion with industry experts, emphasizing the need for close collaboration among materials scientists, process engineers, and metrology experts to enable a holistic strategy, further highlighting the importance of cross-sector partnerships among industry, academia, and government to address pressing challenges in packaging materials and processes.

97 MATHEMATICS AND COMPUTING↗

Investigation of the multiplet features of SrTiO 3 in X-ray absorption spectra based on configuration interaction calculations

Synchrotron-based L 2,3 -edge absorption spectra show strong sensitivities to the local electronic structure and chemical environment. However, detailed physical information cannot be extracted easily without computational aids. Here in this study using the experimental Ti L 2,3 -edges absorption spectrum of SrTiO 3 as a fingerprint and considering full multiplet effects, calculations yield different energy parameters characterizing local ground state properties. The peak splitting and intensity ratios of the L 3 and L 2 set of peaks are carefully analyzed quantitatively, giving rise to a small hybridization energy around 1.2 eV, and the different hybridization energy values reported in the literature are further addressed. Finally, absorption spectra with different linearly polarized photons under various tetragonal crystal fields are investigated, revealing a non-linear orbital–lattice interaction, and a theoretical guidance for material engineering of SrTiO 3 -based thin films and heterostructures is offered. Finally, detailed analysis of spectrum shifts with different tetragonal crystal fields suggests that the e g crystal field splitting is a necessary parameter for a thorough analysis of the spectra, even though it is not relevant for the ground state properties.

3 d transition metal oxide↗

SMAC: A soft MAC to reduce control overhead and latency in CDMA-based AMI networks

The utilization of state-of-the-art 3G cellular CDMA technologies in a utility owned AMI network results in a large amount of control traffic relative to data traffic, increases the average packet delay and hence are not an appropriate choice for smart grid distribution applications. Like the CDG, we consider a utility owned cellular like CDMA network for smart grid distribution applications and classify the distribution smart grid data as scheduled data and random data. Also, we propose SMAC protocol, which changes its mode of operation based on the type of the data being collected to reduce the data collection latency and control overhead when compared to 3G cellular CDMA2000 MAC. The reduction in the data collection latency and control overhead aids in increasing the number of smart meters served by a base station within the periodic data collection interval, which further reduces the number of base stations needed by a utility or reduces the bandwidth needed to collect data from all the smart meters. The reduction in the number of base stations and/or the reduction in the data transmission bandwidth reduces the CAPital EXpenditure (CAPEX) and OPerational EXpenditure (OPEX) of the AMI network. Finally, the proposed SMAC protocol is analyzed using markov chain, analytical expressions for average throughput and average packet delay are derived, and simulation results are also provided to verify the analysis.

97 MATHEMATICS AND COMPUTING↗

TU-CD-BRA-11: Application of Bone Suppression Technique to Inspiratory/expiratory Chest Radiography

Purpose: The bone suppression technique based on advanced image processing can suppress the conspicuity of bones on chest radiographs, creating soft tissue images normally obtained by the dual-energy subtraction technique. This study was performed to investigate the usefulness of bone suppression technique in quantitative analysis of pulmonary function in inspiratory/expiratory chest radiography. Methods: Commercial bone suppression image processing software (ClearRead; Riverain Technologies) was applied to paired inspiratory/expiratory chest radiographs of 107 patients (normal, 33; abnormal, 74) to create corresponding bone suppression images. The abnormal subjects had been diagnosed with pulmonary diseases, such as pneumothorax, pneumonia, emphysema, asthma, and lung cancer. After recognition of the lung area, the vectors of respiratory displacement were measured in all local lung areas using a cross-correlation technique. The measured displacement in each area was visualized as displacement color maps. The distribution pattern of respiratory displacement was assessed by comparison with the findings of lung scintigraphy. Results: Respiratory displacement of pulmonary markings (soft tissues) was able to be quantified separately from the rib movements on bone suppression images. The resulting displacement map showed a left-right symmetric distribution increasing from the lung apex to the bottom region of the lung in many cases. However, patients with ventilatory impairments showed a nonuniform distribution caused by decreased displacement of pulmonary markings, which were confirmed to correspond to area with ventilatory impairments found on the lung scintigrams. Conclusion: The bone suppression technique was useful for quantitative analysis of respiratory displacement of pulmonary markings without any interruption of the rib shadows. Abnormal areas could be detected as decreased displacement of pulmonary markings. Inspiratory/expiratory chest radiography combined with the bone suppression technique has potential for predicting local lung function on the basis of dynamic analysis of pulmonary markings. This work was partially supported by Nakatani Foundation, Grant-in-aid for Scientific Research (C) of Ministry of Education, Culture, Sports, Science and Technology, JAPAN (Grant number : 24601007), and Nakatani Foundation, Mitsubishi Foundation, and the he Mitani Foundation for Research and Development. Yasushi Kishitani is a staff of TOYO corporation.

60 APPLIED LIFE SCIENCES↗

Expectation-maximization algorithms for learning a finite mixture of univariate survival time distributions from partially specified class values

Heterogeneity exists on a data set when samples from di erent classes are merged into the data set. Finite mixture models can be used to represent a survival time distribution on heterogeneous patient group by the proportions of each class and by the survival time distribution within each class as well. The heterogeneous data set cannot be explicitly decomposed to homogeneous subgroups unless all the samples are precisely labeled by their origin classes; such impossibility of decomposition is a barrier to overcome for estimating nite mixture models. The expectation-maximization (EM) algorithm has been used to obtain maximum likelihood estimates of nite mixture models by soft-decomposition of heterogeneous samples without labels for a subset or the entire set of data. In medical surveillance databases we can find partially labeled data, that is, while not completely unlabeled there is only imprecise information about class values. In this study we propose new EM algorithms that take advantages of using such partial labels, and thus incorporate more information than traditional EM algorithms. We particularly propose four variants of the EM algorithm named EM-OCML, EM-PCML, EM-HCML and EM-CPCML, each of which assumes a specific mechanism of missing class values. We conducted a simulation study on exponential survival trees with five classes and showed that the advantages of incorporating substantial amount of partially labeled data can be highly signi cant. We also showed model selection based on AIC values fairly works to select the best proposed algorithm on each specific data set. A case study on a real-world data set of gastric cancer provided by Surveillance, Epidemiology and End Results (SEER) program showed a superiority of EM-CPCML to not only the other proposed EM algorithms but also conventional supervised, unsupervised and semi-supervised learning algorithms.

97 MATHEMATICS AND COMPUTING↗

Coarse-Grained Density Functional Theory Predictions via Deep Kernel Learning

Scalable electronic predictions are critical for soft materials design. Recently, the Electronic Coarse-Graining (ECG) method was introduced to renormalize all-atom quantum chemical (QC) predictions to coarse-grained (CG) resolutions using deep neural networks (DNNs). While DNNs can learn complex representations that prove challenging for kernel-based methods, they are susceptible to overfitting and the overconfidence of uncertainty estimations. Here, we develop ECG within a GPU-accelerated Deep Kernel Learning (DKL) framework to enable CG QC predictions using range-separated hybrid density functional theory (DFT), obtaining a 107 speedup relative to naive all-atom QC. By treating the predicted electronic properties as random Gaussian Processes, DKL incorporates CG mapping degeneracy by learning the distribution of electronic energies as a function of CG configuration. DKL-ECG accurately reproduces molecular orbital energies from range-separated DFT while facilitating efficient training via active learning using the uncertainties provided by DKL. Further, we show that while active learning algorithms enable efficient sampling of a more diverse configurational space relative to random sampling, all explored query methods exhibit comparable performance for the examined system. We attribute this result to the significant overlap of the feature space and output property distributions across multiple temperatures.

97 MATHEMATICS AND COMPUTING↗

MO-G-17A-03: MR-Based Cortical Bone Segmentation for PET Attenuation Correction with a Non-UTE 3D Fast GRE Sequence

Purpose: To determine the feasibility of identifying cortical bone on MR images with a short-TE 3D fast-GRE sequence for attenuation correction of PET data in PET/MR. Methods: A water-fat-bone phantom was constructed with two pieces of beef shank. MR scans were performed on a 3T MR scanner (GE Discovery™ MR750). A 3D GRE sequence was first employed to measure the level of residual signal in cortical bone (TE{sub 1}/TE{sub 2}/TE{sub 3}=2.2/4.4/6.6ms, TR=20ms, flip angle=25°). For cortical bone segmentation, a 3D fast-GRE sequence (TE/TR=0.7/1.9ms, acquisition voxel size=2.5×2.5×3mm{sup 3}) was implemented along with a 3D Dixon sequence (TE{sub 1}/TE{sub 2}/TR=1.2/2.3/4.0ms, acquisition voxel size=1.25×1.25×3mm{sup 3}) for water/fat imaging. Flip angle (10°), acquisition bandwidth (250kHz), FOV (480×480×144mm{sup 3}) and reconstructed voxel size (0.94×0.94×1.5mm{sup 3}) were kept the same for both sequences. Soft tissue and fat tissue were first segmented on the reconstructed water/fat image. A tissue mask was created by combining the segmented water/fat masks, which was then applied on the fast-GRE image (MRFGRE). A second mask was created to remove the Gibbs artifacts present in regions in close vicinity to the phantom. MRFGRE data was smoothed with a 3D anisotropic diffusion filter for noise reduction, after which cortical bone and air was separated using a threshold determined from the histogram. Results: There is signal in the cortical bone region in the 3D GRE images, indicating the possibility of separating cortical bone and air based on signal intensity from short-TE MR image. The acquisition time for the 3D fast-GRE sequence was 17s, which can be reduced to less than 10s with parallel imaging. The attenuation image created from water-fat-bone segmentation is visually similar compared to reference CT. Conclusion: Cortical bone and air can be separated based on intensity in MR image with a short-TE 3D fast-GRE sequence. Further research is required to optimize the strategy to reduce Gibbs artifacts.

60 APPLIED LIFE SCIENCES↗

A dual cone-beam CT system for image guided radiotherapy: Initial performance characterization

Purpose: The purpose of this study is to evaluate the performance of a recently developed benchtop dual cone-beam computed tomography (CBCT) system with two orthogonally placed tube/detector sets. Methods: The benchtop dual CBCT system consists of two orthogonally placed 40 Multiplication-Sign 30 cm flat-panel detectors and two conventional x-ray tubes with two individual high-voltage generators sharing the same rotational axis. The x-ray source to detector distance is 150 cm and x-ray source to rotational axis distance is 100 cm for both subsystems. The objects are scanned through 200 Degree-Sign of rotation. The dual CBCT system utilized 110 Degree-Sign of projection data from one detector and 90 Degree-Sign from the other while the two individual single CBCTs utilized 200 Degree-Sign data from each detector. The system performance was characterized in terms of uniformity, contrast, spatial resolution, noise power spectrum, and CT number linearity. The uniformities, within the axial slice and along the longitudinal direction, and noise power spectrum were assessed by scanning a water bucket; the contrast and CT number linearity were measured using the Catphan phantom; and the spatial resolution was evaluated using a tungsten wire phantom. A skull phantom and a ham were also scanned to provide qualitative evaluation of high- and low-contrast resolution. Each measurement was compared between dual and single CBCT systems. Results: Compared to single CBCT, the dual CBCT presented: (1) a decrease in uniformity by 1.9% in axial view and 1.1% in the longitudinal view, as averaged for four energies (80, 100, 125, and 150 kVp); (2) comparable or slightly better contrast (0{approx}25 HU) for low-contrast objects and comparable contrast for high-contrast objects; (3) comparable spatial resolution; (4) comparable CT number linearity with R{sup 2}{>=} 0.99 for all four tested energies; (5) lower noise power spectrum in magnitude. Dual CBCT images of the skull phantom and the ham demonstrated both high-contrast resolution and good soft-tissue contrast. Conclusions: The performance of a benchtop dual CBCT imaging system has been characterized and is comparable to that of a single CBCT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterize traction–separation relation and interfacial imperfections by data-driven machine learning models

Abstract Interfacial mechanical properties are important in composite materials and their applications, including vehicle structures, soft robotics, and aerospace. Determination of traction–separation (T–S) relations at interfaces in composites can lead to evaluations of structural reliability, mechanical robustness, and failures criteria. Accurate measurements on T–S relations remain challenging, since the interface interaction generally happens at microscale. With the emergence of machine learning (ML), data-driven model becomes an efficient method to predict the interfacial behaviors of composite materials and establish their mechanical models. Here, we combine ML, finite element analysis (FEA), and empirical experiments to develop data-driven models that characterize interfacial mechanical properties precisely. Specifically, eXtreme Gradient Boosting (XGBoost) multi-output regressions and classifier models are harnessed to investigate T–S relations and identify the imperfection locations at interface, respectively. The ML models are trained by macroscale force–displacement curves, which can be obtained from FEA and standard mechanical tests. The results show accurate predictions of T–S relations ( R 2 = 0.988) and identification of imperfection locations with 81% accuracy. Our models are experimentally validated by 3D printed double cantilever beam specimens from different materials. Furthermore, we provide a code package containing trained ML models, allowing other researchers to establish T–S relations for different material interfaces.

97 MATHEMATICS AND COMPUTING↗

Large Vehicle Lunar Landing Surface Interaction and In-Situ Resource Based Risk Mitigation: Landing & Launch Pads

A key capability required for the exploration of planetary bodies is the ability to land on the surface. Previous work performed by NASA and other institutions has primarily focused on landing small spacecraft on planetary surfaces and the associated small-to-medium thrusters required for the soft landing. In the case of human exploration—particularly the establishment of long duration exploration and habitation outposts—the ability to land large landers, such as the SpaceX Starship, is necessary. These larger landing systems require the use of more powerful engines, with higher engine exhaust temperatures and higher landing loads. Understanding the excavation of material by the engines, as well as the potential for the landing legs to sink into the subsurface, is key in ensuring reliable and safe landings. A further improvement in landing reliability can be achieved by constructing landing / launch pads, especially with in-situ resources. Some material excavation by the plume is inevitable, leaving at least a portion of the surface scoured and uneven under the lander and ejecting regolith particles and rocks at very high velocities. One possible solution would be to robotically build landing / launch pads (ideally autonomously) at the destination using in-situ materials. In this case, the first one or few landers will need to land on unimproved surfaces at higher risk; however, they would bring the required equipment to build the landing pads with mostly local resources, thus increasing the reliability of safe landing for subsequent larger landers. A number of methods to build in-situ landing and launch pads have already been developed. These methods include no, or some, addition of required binder additives to the local regolith material, different processing approaches and result in varying landing pad strengths. A sub-scale rocket engine plume, was used to simulate some of the conditions of a landing on the Moon to assess the effectiveness of various materials for an in-situ built landing pad, The GO2/GCH4rocket engine fired on a 1m2area coupons of representative pad materials. The results will allow continued development towards materials that satisfy the landing pad properties required for the effective risk reduction and increased reliability for landing people and equipment on the lunar surface. This work contained two parts: (1) computer modeling of a large rocket engine plume interacting with regolith on the Moon, using the Granular Gas Flow Solver (GGFS) provided by CFD Research Corporation as well as other computational fluid dynamics codes (CFD) such as Loci/CHEM. (2) Developing landing/launch pad materials that could be used for in-situ construction on the lunar surface in the future, to mitigate the calculated effects of a large vehicle rocket engine landing and launching on the Moon.

Lunar↗

Large Vehicle Lunar Landing Surface Interaction and In-Situ Resource Based Risk Mitigation: Landing & Launch Pads

A key capability required for the exploration of planetary bodies is the ability to land on the surface. Previous work performed by NASA and other institutions has primarily focused on landing small spacecraft on planetary surfaces and the associated small-to-medium thrusters required for the soft landing. In the case of human exploration—particularly the establishment of long duration exploration and habitation outposts—the ability to land large landers, such as the SpaceX Starship, is necessary. These larger landing systems require the use of more powerful engines, with higher engine exhaust temperatures and higher landing loads. Understanding the excavation of material by the engines, as well as the potential for the landing legs to sink into the subsurface, is key in ensuring reliable and safe landings. A further improvement in landing reliability can be achieved by constructing landing / launch pads, especially with in-situ resources. Some material excavation by the plume is inevitable, leaving at least a portion of the surface scoured and uneven under the lander and ejecting regolith particles and rocks at very high velocities. One possible solution would be to robotically build landing / launch pads (ideally autonomously) at the destination using in-situ materials. In this case, the first one or few landers will need to land on unimproved surfaces at higher risk; however, they would bring the required equipment to build the landing pads with mostly local resources, thus increasing the reliability of safe landing for subsequent larger landers. A number of methods to build in-situ landing and launch pads have already been developed. These methods include no or some addition of required binder additives to the local regolith material, different processing approaches and result in varying landing pad strengths. A sub-scale rocket engine plume, was used to simulate some of the conditions of a landing on the Moon to assess the effectiveness of various materials for an in-situ built landing pad, The GO2/GCH4 rocket engine fired on 1m2 area coupons of representative pad materials. The results will allow continued development towards materials that satisfy the landing pad properties required for the effective risk reduction and increased reliability for landing people and equipment on the lunar surface. This work contained two parts: (1) computer modeling of a large rocket engine plume interacting with regolith on the Moon, using the Granular Gas Flow Solver (GGFS) provided by CFD Research Corporation as well as other computational fluid dynamics codes (CFD) such as Loci/CHEM. (2) Developing landing/launch pad materials that could be used for in-situ construction on the lunar surface in the future, to mitigate the calculated effects of a large vehicle rocket engine landing and launching on the Moon. The resulting computed values of plume impingement surface temperature, stagnation pressure, gas velocity, shear stress and heat flux were then matched as closely as possible in the Earth’s atmosphere in a sub-scale rocket engine GO2/CH4 test which was provided by Masten Space Systems in Mojave, California. The rocket engine was mounted on a test stand with vertical translation capabilities so that the landing operations of a lander could be simulated (Figure 1).The pad materials test coupons were placed at the surface of a large bin containing simulated lunar basalt regolith and subjected to a test firing as shown in Figure 2. The results of this testing will be presented with related findings, analysis and discussion.

Plume Surface Interaction↗

Image quality improvement in megavoltage cone beam CT using an imaging beam line and a sintered pixelated array system

Purpose: To quantify the improvement in megavoltage cone beam computed tomography (MVCBCT) image quality enabled by the combination of a 4.2 MV imaging beam line (IBL) with a carbon electron target and a detector system equipped with a novel sintered pixelated array (SPA) of translucent Gd{sub 2}O{sub 2}S ceramic scintillator. Clinical MVCBCT images are traditionally acquired with the same 6 MV treatment beam line (TBL) that is used for cancer treatment, a standard amorphous Si (a-Si) flat panel imager, and the Kodak Lanex Fast-B (LFB) scintillator. The IBL produces a greater fluence of keV-range photons than the TBL, to which the detector response is more optimal, and the SPA is a more efficient scintillator than the LFB. Methods: A prototype IBL + SPA system was installed on a Siemens Oncor linear accelerator equipped with the MVision{sup TM} image guided radiation therapy (IGRT) system. A SPA strip consisting of four neighboring tiles and measuring 40 cm by 10.96 cm in the crossplane and inplane directions, respectively, was installed in the flat panel imager. Head- and pelvis-sized phantom images were acquired at doses ranging from 3 to 60 cGy with three MVCBCT configurations: TBL + LFB, IBL + LFB, and IBL + SPA. Phantom image quality at each dose was quantified using the contrast-to-noise ratio (CNR) and modulation transfer function (MTF) metrics. Head and neck, thoracic, and pelvic (prostate) cancer patients were imaged with the three imaging system configurations at multiple doses ranging from 3 to 15 cGy. The systems were assessed qualitatively from the patient image data. Results: For head and neck and pelvis-sized phantom images, imaging doses of 3 cGy or greater, and relative electron densities of 1.09 and 1.48, the CNR average improvement factors for imaging system change of TBL + LFB to IBL + LFB, IBL + LFB to IBL + SPA, and TBL + LFB to IBL + SPA were 1.63 (p < 10{sup -8}), 1.64 (p < 10{sup -13}), 2.66 (p < 10{sup -9}), respectively. For all imaging doses, soft tissue contrast was more easily differentiated on IBL + SPA head and neck and pelvic images than TBL + LFB and IBL + LFB. IBL + SPA thoracic images were comparable to IBL + LFB images, but less noisy than TBL + LFB images at all imaging doses considered. The mean MTFs over all imaging doses were comparable, at within 3%, for all imaging system configurations for both the head- and pelvis-sized phantoms. Conclusions: Since CNR scales with the square root of imaging dose, changing from TBL + LFB to IBL + LFB and IBL + LFB to IBL + SPA reduces the imaging dose required to obtain a given CNR by factors of 0.38 and 0.37, respectively. MTFs were comparable between imaging system configurations. IBL + SPA patient image quality was always better than that of the TBL + LFB system and as good as or better than that of the IBL + LFB system, for a given dose.

61 RADIATION PROTECTION AND DOSIMETRY↗