Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Simulation of distributed computing systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Intelligent computer-aided training authoring environment

Although there has been much research into intelligent tutoring systems (ITS), there are few authoring systems available that support ITS metaphors. Instructional developers are generally obliged to use tools designed for creating on-line books. We are currently developing an authoring environment derived from NASA's research on intelligent computer-aided training (ICAT). The ICAT metaphor, currently in use at NASA has proven effective in disciplines from satellite deployment to high school physics. This technique provides a personal trainer (PT) who instructs the student using a simulated work environment (SWE). The PT acts as a tutor, providing individualized instruction and assistance to each student. Teaching in an SWE allows the student to learn tasks by doing them, rather than by reading about them. This authoring environment will expedite ICAT development by providing a tool set that guides the trainer modeling process. Additionally, this environment provides a vehicle for distributing NASA's ICAT technology to the private sector.

Way, Robert D.↗

Towards a Comprehensive Computational Simulation System for Turbomachinery

The objective of this work is to develop algorithms associated with a comprehensive computational simulation system for turbomachinery flow fields. This development is accomplished in a modular fashion. These modules includes grid generation, visualization, network, simulation, toolbox, and flow modules. An interactive grid generation module is customized to facilitate the grid generation process associated with complicated turbomachinery configurations. With its user-friendly graphical user interface, the user may interactively manipulate the default settings to obtain a quality grid within a fraction of time that is usually required for building a grid about the same geometry with a general-purpose grid generation code. Non-Uniform Rational B-Spline formulations are utilized in the algorithm to maintain geometry fidelity while redistributing grid points on the solid surfaces. Bezier curve formulation is used to allow interactive construction of inner boundaries. It is also utilized to allow interactive point distribution. Cascade surfaces are transformed from three-dimensional surfaces of revolution into two-dimensional parametric planes for easy manipulation. Such a transformation allows these manipulated plane grids to be mapped to surfaces of revolution by any generatrix definition. A sophisticated visualization module is developed to al-low visualization for both grid and flow solution, steady or unsteady. A network module is built to allow data transferring in the heterogeneous environment. A flow module is integrated into this system, using an existing turbomachinery flow code. A simulation module is developed to combine the network, flow, and visualization module to achieve near real-time flow simulation about turbomachinery geometries. A toolbox module is developed to support the overall task. A batch version of the grid generation module is developed to allow portability and has been extended to allow dynamic grid generation for pitch changing turbomachinery configurations. Various applications with different characteristics are presented to demonstrate the success of this system.

Shih, Ming-Hsin↗

Methodolgy For Evaluation Of Technology Impacts In Space Electric Power Systems

The Analysis and Management branch of the Power and Propulsion Office at NASA Glenn Research Center is responsible for performing complex analyses of the space power and In-Space propulsion products developed by GRC. This work quantifies the benefits of the advanced technologies to support on-going advocacy efforts. The Power and Propulsion Office is committed to understanding how the advancement in space technologies could benefit future NASA missions. They support many diverse projects and missions throughout NASA as well as industry and academia. The area of work that we are concentrating on is space technology investment strategies. Our goal is to develop a Monte-Carlo based tool to investigate technology impacts in space electric power systems. The framework is being developed at this stage, which will be used to set up a computer simulation of a space electric power system (EPS). The outcome is expected to be a probabilistic assessment of critical technologies and potential development issues. We are developing methods for integrating existing spreadsheet-based tools into the simulation tool. Also, work is being done on defining interface protocols to enable rapid integration of future tools. Monte Carlo-based simulation programs for statistical modeling of the EPS Model. I decided to learn and evaluate Palisade's @Risk and Risk Optimizer software, and utilize it's capabilities for the Electric Power System (EPS) model. I also looked at similar software packages (JMP, SPSS, Crystal Ball, VenSim, Analytica) available from other suppliers and evaluated them. The second task was to develop the framework for the tool, in which we had to define technology characteristics using weighing factors and probability distributions. Also we had to define the simulation space and add hard and soft constraints to the model. The third task is to incorporate (preliminary) cost factors into the model. A final task is developing a cross-platform solution of this framework.

Holda, Julie↗

EGSim - a C++ Toolkit for Analysis of Power Grid Systems

We describe the load flow formulation and the solution algorithms available in the Electric power Grid Simulator (EGSim) software toolkit. EGSim contains tools aimed at simulating static load flow solutions for electric power grids. It parses power grid models described in IEEE Common Data Format, and generates solutions for the bus voltages and voltage angles, and real and reactive power values through the transmission lines. The software, written in C++, implements both Gauss-Seidel and Newton solution methods. Example results for the 118 bus models and 300 bus models are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advancement of hybrid fluid-kinetic modeling for HEDP and ICF science

We report on the development progress of a hybrid fluid-kinetic code for simulating fluids and plasmas in a wide range of environments, such as laser–matter interactions, inertial confinement fusion, magnetic confinement fusion, and pulsed power. The suite of numerical tools under development utilizes heterogeneous computer architectures and leverages the benefits of particle–based simulation techniques. By working to combine the kinetic particle-in-cell (PIC) model with a particle-based fluid simulation technique, such as smoothed particle hydrodynamics, we are developing a flexible framework capable of accurately modeling complex flows within and between kinetic and fluid regimes. The TriForce code is under development as a C++ framework for parallel, 3D, particle-based, hybrid fluid-kinetic plasma simulations. The fluid half of TriForce will be based upon the meshless smoothed-particle-hydrodynamics (SPH) approach, well-suited for shear, mixing, and turbulence, whereas the kinetic half resembles a traditional particle-in-cell (PIC) code; other particle-based approaches to fluid modeling that do use a mesh are also possible to use and are under investigation. Maxwell’s electromagnetic field equations are solved either via explicit or implicit algorithms or approximated via resistive magnetohydrodynamics (MHD) using an Ohm’s law and resulting induction equation (extended MHD is under development). A primary goal of enabling direct comparisons, from the same code, between results from the variants of MHD and implicit electromagnetic solutions is to improve our fundamental understanding of systems with magnetic fields. The code is under development to recover results from both radiation-MHD and fully kinetic codes in those limits, and is continuing to be developed from other follow-on grants to operate in between where both descriptions may co-exist and interact. For certain applications, it is desired for a simulation to contain fluid ions and electrons as well as kinetic ions and electrons. Typically, it is too computationally intensive to model a full-scale ICF or HEDP experiment fully kinetically since many cycles are expended with very small time steps on modeling the fluid part of a material that is well treated by the fluid approximation. In this case, many traditional PIC particles can be replaced with a single fluid particle representing the thermal part of the distribution function, and there are fewer needed kinetic particles, which describe the non-thermal part and can be sub-cycled relative to the fluid particle advance. Furthermore, a pure fluid code may, depending on the problem, simply lack many physically important details that are beyond the scope of its reduced approximations and assumptions. In this report, we summarize the objectives achieved in the development of the collisional and kinetic half of the code, and the physics problems to which the code has been applied in the areas of advanced and innovative fusion concepts, pulsed power, and magneto-inertial fusion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computer network environment planning and analysis

The GSFC Computer Network Environment provides a broadband RF cable between campus buildings and ethernet spines in buildings for the interlinking of Local Area Networks (LANs). This system provides terminal and computer linkage among host and user systems thereby providing E-mail services, file exchange capability, and certain distributed computing opportunities. The Environment is designed to be transparent and supports multiple protocols. Networking at Goddard has a short history and has been under coordinated control of a Network Steering Committee for slightly more than two years; network growth has been rapid with more than 1500 nodes currently addressed and greater expansion expected. A new RF cable system with a different topology is being installed during summer 1989; consideration of a fiber optics system for the future will begin soon. Summmer study was directed toward Network Steering Committee operation and planning plus consideration of Center Network Environment analysis and modeling. Biweekly Steering Committee meetings were attended to learn the background of the network and the concerns of those managing it. Suggestions for historical data gathering have been made to support future planning and modeling. Data Systems Dynamic Simulator, a simulation package developed at NASA and maintained at GSFC was studied as a possible modeling tool for the network environment. A modeling concept based on a hierarchical model was hypothesized for further development. Such a model would allow input of newly updated parameters and would provide an estimation of the behavior of the network.

Dalphin, John F.↗

Optimized V1G and V2G Electric Vehicle Fleet Management and Grid Transaction at Marine Corps Air Station Miramar in San Diego, CA

The overall technical goal of the project was to demonstrate an all-electric bi-directional non-tactical fleet at Marine Corps Air Station (MCAS) Miramar that was integrated and controlled with other distributed energy resources (DERs) (i.e., PV, stationary battery, and building loads) to provide resilience to critical electric loads in the event of grid outages, to minimize charging costs, and to provide economic energy resources to electricity markets. In this project, the specific, technical objectives were: 1. Demonstrate that bi-directional electric vehicles can provide critical complementary services to fixed storage batteries in microgrid applications while performing function as non-tactical vehicles. 2. Demonstrate participation of bi-directional (V2G) and unidirectional (V1G) PEVs for demand management and minimization of charging costs. 3. Demonstrate integration of multiple DERs for grid service participation. US Marine Corps Air Station (MCAS) Miramar in San Diego was the site of this electric vehicle-to-microgrid-utility grid test and demonstration project. Existing microgrid assets in this study included (1) a public works building; (2) a 30-kW rooftop photovoltaic (PV) system and (3) a separate 250 kW carport PV system. In this project, six bi-directional V2G vans were located at the MCAS Miramar’s showcase building-scale microgrid to develop and test technical capabilities that V2G can provide in microgrid applications (e.g., cost reduction and resiliency). These resources provided aggregated demand management and simulated participation in current retail DR programs. The vehicles used in this demonstration were selected because they provided functionality that MCAS Miramar needed, 15 passenger transport and facilities work cargo carrying capacity, and bi-directional charging capability that the research project required. All vehicles in this study were manufactured and distributed by VIA Motors, Inc. There were six vehicles total and each was VIA’s VTRUX eREV V2G model, a modified General Motors Chevrolet 2500 2WD van. Three of the vans were configured as passenger vans and the other three were configured as cargo vans. Each van had an on-board bi-direcrtional inverter/charger, Bel Power Solutions model 350INVCHGT150-120-240-8G nominally rated at +/-15 kW. The VIA van’s charging connector follows the J1772 charging protocol. The bi-directional EVSEs demonstrated in this study were manufactured by Coritech, Inc. Each VGI-80-AC charging station enabled enhanced V2G charging capability to a Clipper Creek CS-100 charging module. The enhanced capabilities included ethernet communication following the SEP2.0 protocol with a distributed energy resource function set and an operator screen displaying real-time SOC, voltage, and current. The VGI-80-AC charging stations are classified as level 2 with a maximum current output of 80 A or effectively 19 kW. The VIA van’s onboard charger limited the charging and discharging power to 15 kW in each direction. A control computer was installed in the EWOC and connected to an existing monitor. The V2G control communication network was a completely stand-alone closed system that did not have any connection to any other networks on the base. A cybersecure remote communication connection was created with a cellular modem, firewall hardware, and a virtual private network configuration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The computer simulation of automobile use patterns for defining battery requirements for electric cars

A Monte Carlo simulation process was used to develop the U.S. daily range requirements for an electric vehicle from probability distributions of trip lengths and frequencies and average annual mileage data. The analysis shows that a car in the U.S. with a practical daily range of 82 miles (132 km) can meet the needs of the owner on 95% of the days of the year, or at all times other than his long vacation trips. Increasing the range of the vehicle beyond this point will not make it more useful to the owner because it will still not provide intercity transportation. A daily range of 82 miles can be provided by an intermediate battery technology level characterized by an energy density of 30 to 50 watt-hours per pound (66 to 110 W-hr/kg). Candidate batteries in this class are nickel-zinc, nickel-iron, and iron-air. The implication of these results for the research goals of far-term battery systems suggests a shift in emphasis toward lower cost and greater life and away from high energy density.

Schwartz, H. J.↗

Future SDN-HPON Control Plane Architecture and Protocol for On-Demand Terabit End-to-End Extreme-Scale Science Applications

The UC Davis team conducted architecture, algorithm and experimental studies for next generation ultra-high-bandwidth optical networks in support of extreme-scale science applications. In particular, over the course of this 3-year project, the UC Davis team achieved the following main accomplishments: Designed a network architecture for automated multi-domain service provisioning: Designed information exchange schemes between autonomous systems (domains) Designed application programming interfaces to orchestrate resource reservation in data centers, high performance computation facilities, and communication networks belonging to different autonomous systems Experimentally assessed the multi-domain network architecture in a distributed field trial set-up connecting premises in three continents Designed a broker-based orchestrated multi-domain optical networking framework supporting observe-analyze-act cycle based cognitive inter-domain service provisioning: Designed an inter-domain operation mechanism, e.g., topology abstraction, for the broker plane and domain managers to collaboratively accomplish inter-domain service provisioning while respecting the autonomy of each administrative domain Designed an alien wavelength monitoring scheme and an artificial neural network based optical signal-to-noise ratio estimator for quality-of-transmission aware inter-domain service provisioning Developed a deep neural network based multi-domain traffic predictor and a cognitive routing and spectrum assignment algorithm to realize knowledge-based autonomous traffic engineering in multi-domain networks Implemented an optical signal-to-noise ratio estimator and traffic predictor with Google’s Tensor flow and assessed their performance using experimental and synthetic data Demonstrated the benefits of the proposed cognitive schemes with experiments ona two-domain elastic optical network testbed and evaluations on a six-domain simulation framework Built a two-domain software-defined networking control plane testbed using the ONOS platform and demonstrated the workflow of broker and domain manager cooperation, including hierarchical performance monitoring, topology abstraction and cognitive resource allocation. Designed self-learning cognitive service provisioning schemes using advanced machine learning technologies: Designed a self-taught anomaly detection framework for optical networks, including an unsupervised data clustering module for pattern recognition, a supervised data regression and classification module for online anomaly detection, and the system operation principle Experimentally validated the effectiveness of the self-taught anomaly detection framework with various failure/anomaly scenarios. Designed a self-learning autonomic routing, modulation and spectrum assignment (RMSA) provisioning framework for elastic optical networks with deep reinforcement learning. Designed effective modeling and training mechanisms for the self-learning RMSA framework Conducted extensive numerical simulations with various traffic patterns and topologies to verify the advantage of the self-learning RMSA framework.

42 ENGINEERING↗

Impact of Storage Dispatch Assumptions on Resource Adequacy and Capacity Credit

Representing energy-limited resources in power system probabilistic resource adequacy assessment introduces new considerations that invalidate classical modeling assumptions. In particular, such resources have multi-period operating objectives and constraints that in real systems are addressed via a sequence of rolling intertemporal optimizations. Ideally, adequacy models would develop dispatch decisions by solving a similar sequence of problems, but this approach has historically been too computationally intensive for practical use in Monte Carlo simulations, with studies making use of simplifying approximations instead. These simplifications have the potential to distort the assessed value of energy-limited resources on the system.This work describes three classes of storage dispatch assumptions in current use and discusses their theoretical differences. It then provides an empirical analysis of their differences on test systems with different levels of storage, assessing the potential for a study's modeling assumptions to influence the perceived contribution of energy-limited resources.

capacity credit↗

Aeroacoustic Computations of a Generic Low Boom Concept in Landing Configuration: Part 1 - Aerodynamic Simulations

Computational results are presented for a 15%-scale, full-span, generic low-boom concept aircraft model simulated as installed in the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel and in free-air conditions. The simulations were conducted with the lattice Boltzmann solver PowerFLOW® to capture the time-accurate characteristics of the flow. The aerodynamic behavior of the aircraft was investigated with various combinations of flap and landing gear deployments. To replicate the flow speed used during tests of the model, a Mach number of approximately 0.20 was chosen while varying the angle of attack through a limited range. Analyses were performed on local flow quantities, global forces, as well as flow distributions between configurations. Aerodynamic quantities were shown to be sensitive to mesh resolution levels, especially with flap and landing gear systems retracted. When comparing wind tunnel to free-air simulations, the aerodynamic quantities sampled were found to be in good agreement, suggesting that tunnel blockage and model support effects did not adversely impact the aerodynamic behavior of the model during the wind tunnel test. The results of this study improve our understanding of the highly complex, vortical flow generated by configurations with swept, low aspect-ratio wings at speeds encountered during landing operations.

low boom↗

A Radiative Transfer Simulator for PACE: Theory and Applications

A radiative transfer simulator was developed to compute the synthetic data of all three instruments onboard NASA’s Plankton Aerosol, Cloud, ocean Ecosystem (PACE) observatory, at the top of the atmosphere (TOA). The instrument suite includes the ocean color instrument (OCI), the HyperAngular Rainbow Polarimeter 2 (HARP2), and the Spectro-Polarimeter for Planetary Exploration 1 (SPEXone). The PACE simulator is wrapped around a monochromatic radiative transfer model based on the successive order of scattering (RTSOS), which accounts for atmosphere and ocean coupling, polarization, and gas absorption. Inelastic scattering, including Raman scattering from pure ocean water, fluorescence due to chlorophyll, and colored dissolved organic matter (CDOM), is also simulated. This PACE simulator can be used to explore the sensitivity of the hyperspectral and polarized reflectance of the Earth system with tunable atmosphere and ocean parameters, which include aerosol and cloud number concentration, refractive indices, and size distribution, ocean particle microphysical parameters, and solar and sensor-viewing geometry. The PACE simulator is used to study two important case studies. One is the impact of the significant uncertainty in pure ocean water absorption coefficient to the radiance field in the ultraviolet (UV) spectral region, which can be as much as 6%. The other is the influence of different amounts of brown carbon aerosols and CDOM on the polarized radiance field at TOA. The percentage variation of the radiance field due to CDOM is mostly for wavelengths smaller than 600 nm, while brown aerosols affect the whole spectrum from 350 to 890 nm, primarily due to covaried soot aerosols. Both case studies are important for aerosol and ocean color remote sensing and have not been previously reported in the literature.

PACE↗

PyPVRPM: Photovoltaic Reliability and Performance Model in Python

The ability to perform accurate techno-economic analysis of solar photovoltaic (PV) systems is essential for bankability and investment purposes. Most energy yield models assume an almost flawless operation (i.e., no failures); however, realistically, components fail and get repaired stochastically. This package, PyPVRPM, is a Python translation and improvement of the Language Kit (LK) based PhotoVoltaic Reliability Performance Model (PVRPM), which was first developed at Sandia National Laboratories in Goldsim software (Granata et al., 2011) (Miller et al., 2012). PyPVRPM allows the user to define a PV system at a specific location and incorporate failure, repair, and detection rates and distributions to calculate energy yield and other financial metrics such as the levelized cost of energy and net present value (Klise, Lavrova, et al., 2017). Our package is a simulation tool that uses NREL’s Python interface for System Advisor Model (SAM) (National Renewable Energy Laboratory, 2020b) (National Renewable Energy Laboratory, 2020a) to evaluate the performance of a PV plant throughout its lifetime by considering component reliability metrics. Besides the numerous benefits from migrating to Python (e.g., speed, libraries, batch analyses), it also expands on the failure and repair processes from the LK version by including the ability to vary monitoring strategies. These failures, repairs, and monitoring processes are based on user-defined distributions and values, enabling a more accurate and realistic representation of cost and availability throughout a PV system’s lifetime.

97 MATHEMATICS AND COMPUTING↗

High-Voltage DC MULTI-terminal SIMulation (HVDC MULTISIM): Technical Program Summary

Expansion of the power grid in the USA is essential to fulfilling the rising energy demand of the country. In particular, the transmission grid, a network of electrical energy corridors that enable the flow of large amounts of energy from the point of generation to the point of consumption, needs significant expansion to cater to this growth of electrification. The current infrastructure is also dated, and any new transmission corridor should be based on a vision of building a modern infrastructure that is futureproof. High voltage DC (HVDC) transmission technology falls in this category: it is the most economical way to build large transmission lines and relies on sophisticated electronics and flexible controls, rather than just passive components like switchgear and transformers. This project is aimed at establishing the technical and economic feasibility of a network of HVDC lines that are interconnected to form a multi-terminal DC network. HVDC transmission is not a new technology and United States has a number of such lines; however, these are point to point transmissions and do not form a DC grid. Modeling and analyzing DC grids is challenging since there are no established modeling tools and the traditional ways of modeling AC grids fall short of providing the fidelity required the fast dynamics of the DC grid. This project aims to build a software-in-the-loop simulator for a multi-terminal HVDC grid, called MULTISIM and, establish new control and protection algorithms to operate such a connected DC system. NLR, a key partner, established the core framework of the MULTISIM simulator and validated its functionality. The GE Vernova team, created a full-scale model of a four-terminal HVDC network using PSCAD (Power Systems Computer Aided Design) software and established the baseline performance of the system during normal and fault operation. The project was started on 10/12024 with a kick-off meeting held on 12/11/2024 and ran through two quarters till termination. All the tasks, milestones and deliverables during this period were met. Several interim reports detailing the various tasks were submitted. The following sections provide details on the completed tasks till the project pause and termination after Q2.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Protection Scheme for Unbalanced Faults in Inverter Dominated Networks: A Computationally Efficient Algorithm for Entry-Level Relays

Microgrids are now a common practice in distribution systems to increase resilience and reliability. However, microgrid protection remains a critical challenge, considering its requirement to operate in both grid connected and islanded, and the variability in fault characteristics under each mode of operation. This paper presents unbalanced power (S unb ) based fault detection algorithm, which considers local voltage and current unbalances to determine faults in the system. S unb is a computationally efficient fault detection algorithm that is suitable for implementation in the programmable logic of entry level protective relays. In addition, the difference in current and voltage unbalance (D n ) is used to determine the fault type. The proposed method demonstrates high sensitivity and selectivity for line-to-ground (LG), line-to-line (LL), and double line-to-ground (LLG) faults, representing the most common faults in distribution systems. It also allows relay coordination with upstream and downstream protection devices in both island and grid connected operation, while preserving grading margins. The same pickup and time multiplier settings of a particular relay for both modes of operation eliminates the need for adaptive settings, which rely on communication networks. Validation was performed with a hardware-in-the-loop (HIL) setup using Typhoon HIL real time simulator interfaced with three entry-level, SEL 751 relays. Results confirmed the algorithm’s ability to discriminate fault conditions, and determine the fault type under both operating modes, maintain fast detection times, and ensure proper protection coordination.

fault classification↗

Economical and Engineering Aspects of Proactive Demand Participation: Centralized versus Bilateral Control Structure

The electric grid of the U.S. is evolving from a system characterized by large and centralized fossil-fueled power plants and passive customers to a network with high penetration of distributed energy resources and proactive customers. This project facilitated the evolution of the U.S. electric power grid by enabling proactive participation of demands in electricity market at the power distribution system level. This project has three major achievements. First, we designed a centralized distribution system operator managed electricity market and developed a three-phase alternating current optimal power flow algorithm to coordinate the operation of large-scale flexible loads and distributed energy resources. Second, we designed a decentralized bilateral coordinate framework for retail electricity market, where each participating customer is capable of making decisions regarding energy production and consumption based on information received from transactive neighbors. Third, the impacts of centralized and decentralized demand-side participation scheme on power system operations were evaluated with both large-scale simulations and hardware-in-the-loop demonstrations. The major activities and specific accomplishments of the technical tasks are summarized in Section II. The detailed design of centralized/hierarchical and decentralized/bilateral retail electricity markets and the comparison between the two markets are described in Section III. The accomplishments and conclusions of the project are presented in Section IV. The major findings of the project falls into three areas, hierarchical distribution system operator managed electricity market, bilateral electricity market and decentralized market coordination, and comparison of centralized and decentralized market coordination mechanisms. In the area of hierarchical distribution system operator managed electricity market design, an integrated wholesale and retail electricity market was shown to be highly effective in extracting the operational flexibility from distributed energy resources to provide services to the wholesale market. A chordal conversion based convex iteration algorithm is not only computationally efficiency but also achieves global optimal solution in coordinating the operations of a large number of heterogeneous distributed energy resources.In the area of decentralized market coordination approach, we showed that bilateral transactions among proactive customers and decentralized transaction clearing mechanism based on simultaneous second-price sealed-bid auction can encourage truthful bidding strategies from the market participations. In addition, the individual customers can rely on a portfolio optimization approach to maximize their returns while minimizing risks. In the area of comparison of centralized and decentralized market coordination mechanisms, we found that the centralized market design results in higher social welfare and lower wholesale market clearing price for electricity. In general, centralized market design favors distributed energy resources and fixed loads. The decentralized market design mostly benefits flexible loads and conventional generators.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Conjugate Heat Transfer Modeling of Salt-Filled Fuel Pins for Stable Salt Reactor Safety Analysis

The Stable Salt Reactor (SSR) combines the proven structural design of light water reactor fuel assemblies with the inherent safety and fuel-cycle advantages of molten salt technology. In its fast reactor configuration, the SSR utilizes recycled nuclear waste as fuel, sealed within narrow salt-filled fuel pins and cooled by a surrounding liquid salt coolant. Reliable transfer of heat from the molten fuel salt through the cladding to the external coolant is essential for both reactor safety and performance. This work investigates conjugate heat transfer (CHT) in the SSR’s salt-filled fuel pins using NekRS, a high-fidelity spectral element computational fluid dynamics (CFD) solver. The analyses capture internal natural convection within the molten fuel salt and external forced convection in the coolant, under steady-state and transient operating conditions. Parametric studies evaluate how variations in reactor power and coolant flow rate influence heat transfer distributions and system response. The high-fidelity CFD results are time-averaged and post-processed for direct comparison with moderate-fidelity Reynolds-averaged Navier–Stokes (RANS) models, and for the development of reduced-order models within the SAM system code. These validated models support fast-running safety analyses of normal and off-normal transients, improving predictive capability for key safety margins. By integrating advanced CFD with system-level safety tools, this study strengthens the modeling framework for SSR design, reduces uncertainty in molten salt CHT simulations, and accelerates the engineering and licensing of next-generation nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Systematic comparison of local approaches for isotopically nonstationary metabolic flux analysis

Quantification of reaction fluxes of metabolic networks can help us understand how the integration of different metabolic pathways determine cellular functions. Yet, intracellular fluxes cannot be measured directly but are estimated with metabolic flux analysis (MFA) that relies on the patterns of isotope labeling of metabolites in the network. For metabolic systems, typical for plants, where all potentially labeled atoms effectively have only one source atom pool, only isotopically nonstationary MFA can provide information about intracellular fluxes. There are several global approaches that implement MFA for an entire metabolic network and estimate, at once, a steady-state flux distribution for all reactions with identifiable fluxes in the network. In contrast, local approaches deal with estimation of fluxes for a subset of reactions, with smaller data demand for flux estimation. Here we present a systematic comparative review and benchmarking of the existing local approaches for isotopically nonstationary MFA. The comparison is conducted with respect to the required data and underlying computational problems solved on a synthetic network example. Furthermore, we benchmark the performance of these approaches in estimating fluxes for a subset of reactions using data obtained from the simulation of nitrogen fluxes in the Arabidopsis thaliana core metabolism. The findings pinpoint practical aspects that need to be considered when applying local approaches for flux estimation in large-scale plant metabolic networks.

59 BASIC BIOLOGICAL SCIENCES↗