Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A Superconducting Micro-Magnetometer for Quantum Vortex in Superconducting Nanoflakes

Superconducting quantum interferometer device (SQUID) plays a key role in understanding electromagnetic properties and emergent phenomena in quantum materials. The technological appeal of SQUID is that its detection accuracy for the electromagnetic signal can precisely reach the quantum level of a single magnetic flux. However, conventional SQUID techniques normally can only be applied to a bulky sample and do not have the capability to probe the magnetic properties of micro-scale samples with small magnetic signals. Here, in this paper, it is demonstrated that, based on a specially designed superconducting nano-hole array, the contactless detection of magnetic properties and quantized vortices in micro-sized superconducting nanoflakes is realized. An anomalous hysteresis loop and a suppression of Little–Parks oscillation are observed in the detected magnetoresistance signal, which originates from the disordered distribution of the pinned vortices in Bi 2 Sr 2 CaCu 2 O 8+δ . Therefore, the density of pinning centers of the quantized vortices on such micro-sized superconducting samples can be quantitatively evaluated, which is technically inaccessible for conventional SQUID detection. The superconducting micro-magnetometer provides a new approach to exploring mesoscopic electromagnetic phenomena of quantum materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Icy Moon Project (Final Report)

For this Icy Moon project, we designed, procured, built, tested and used a compact ICI instrument. This instrument has several technical advances, including a compact form factor that uses fiber arrays to relay light to six APDs. This enables a single data acquisition to measure eleven unique baselines simultaneously. The DAQ is well-synchronized and provides a path forward to even more channels. The combination of a bright LED, a sinusoidal target and cylindrical optics enables high-SNR measurements based on a known formula: a 25-ms measurement should have an SNR of 188 on the baseline zero signal. This rapid measurement time should enable two-dimensional operation and obviate the impact of temperature drifts. However, the experiment did not detect a coherence signal on any baseline (see Section Single-shot measurement results).

47 OTHER INSTRUMENTATION↗

On the precision of automated activation time estimation

We examined how the assignment of local activation times in epicardial and endocardial electrograms is affected by sampling rate, ambient signal-to-noise ratio, and sinx/x waveform interpolation. Algorithms used for the estimation of fiducial point locations included dV/dtmax, and a matched filter detection algorithm. Test signals included epicardial and endocardial electrograms overlying both normal and infarcted regions of dog myocardium. Signal-to-noise levels were adjusted by combining known data sets with white noise "colored" to match the spectral characteristics of experimentally recorded noise. For typical signal-to-noise ratios and sampling rates, the template-matching algorithm provided the greatest precision in reproducibly estimating fiducial point location, and sinx/x interpolation allowed for an additional significant improvement. With few restrictions, combining these two techniques may allow for use of digitization rates below the Nyquist rate without significant loss of precision.

NASA Discipline Cardiopulmonary↗

System and method for in situ volumetric sensing of 3D cure state of resin being used in an additive manufacturing system

An in situ cure monitoring control system for use with a volumetric three dimensional (3D) printing system, wherein the volumetric 3D system includes a container defining a build volume, the container includes a photocurable resist used for making a 3D part, and the resist is responsive to an optical curing beam from a light source, which is controlled by a controller, and which is passed through the resist. The cure monitoring control system includes an optical signal source which generates optical signals having a wavelength selected in relation to a characteristic of the resist, and directed to pass through the build volume. A detector detects the optical signals and generates output signals in accordance therewith. Software monitors the output signals and uses the output signals to modify the curing beam to help optimize curing of the resist.

Panas, Robert Matthew↗

Constraints on the Maximum Densities of Neutron Stars from Postmerger Gravitational Waves with Third-Generation Observations

Using data from 289 numerical relativity simulations of binary neutron star mergers, we identify, for the first time, a robust quasiuniversal relation connecting the postmerger peak gravitational-wave frequency and the value of the density at the center of the maximum mass nonrotating neutron star. This relation offers a new possibility for precision equation-of-state constraints with next-generation ground-based gravitational-wave interferometers. Mock Einstein Telescope observations of fiducial events indicate that Bayesian inferences can constrain the maximum density to ~15% (90% credibility level) for a single signal at the minimum sensitivity threshold for a detection. If the postmerger signal is included in a full-spectrum (inspiral-merger-postmerger) analysis of such a signal, the pressure-density function can be tightly constrained up to the maximum density, and the maximum neutron star mass can be measured with an accuracy better than 12% (90% credibility level).

79 ASTRONOMY AND ASTROPHYSICS↗

Hexagonal multiple phase-and-amplitude-shift-keyed signal sets

Selection of a particular signal set array for a bandwidth-constrained multiple phase-and-amplitude-shift-keyed (MPASK) communication system for a linear additive Gaussian noise channel requires consideration of factors such as average and/or peak power vs symbol error probability, signal amplitude dynamic range, simplicity of generation and detection, and number of bit errors per symbol error (Gray code properties). A simple technique is presented for generating and optimally detecting the honeycomb (hexagonal) signal set, i.e., the signal set that has the tightest sphere-packing properties. The symbol and bit error probability performance of this set is compared to other two-dimensional signal sets that have been investigated in the literature, and is shown to be slightly superior from an average power standpoint. The paper concludes with a comparison of all of these signal sets from the standpoint of the factors listed above.

Simon, M. K.↗

Infrared Pulse-laser Long-path Absorption Measurement of Carbon Dioxide Using a Raman-shifted Dye Laser

A pulsed laser source is effective in infrared laser long-path absorption measurements when the optical path length is very long or the reflection from a hard target is utilized, because higher signal-to-noise ratio is obtained in the detection of weak return signals. We have investigated the performance of a pulse-laser long-path absorption system using a hydrogen Raman shifter and a tunable dye laser pumped by a Nd:YAG laser, which generates second Stokes radiation in the 2-micron region.

Minato, Atsushi↗

Microwave Power Detection With Voltage-Gated Graphene

Commercially available, chemical vapor deposition grown, graphene has been used to realizevoltage-gate tunable, microwave power detectors. Corbino disc structures with chrome/gold contacts havebeen fabricated on top of graphene deposited on P-type silicon substrates with silicon dioxide gate oxides.Devices of varying sizes were used to detect a 433.92 MHz signal. These test structures exhibited a peak power detection sensitivity of 3.25 mV/mW at 292 K and 5.43 mV/mW at 80 K. The improved graphene detectors exceed the sensitivity of previously reported graphene detectors, 0.86 mV/mW, as well as previously explored carbon nanotube bolometers, 0.36 mV/mW

Michael R. Gasper↗

Evidence for lightning on Venus

Evidence for lightning on Venus obtained by the Pioneer Venus 1 Orbiter is presented. The first indications of lightning were detected by the electric field detector on board the Orbiter when the spacecraft periapsis, which is well within the ionosphere, moved into the night side of the planet. Impulsive wave signals were primarily detected at altitudes less than 25 km, and were found to be strongest at frequencies corresponding to propagation in the whistler mode, occurring at an average rate of about 0.5/sec. The signals were often observed during intervals of low and variable electron densities. It is tentatively concluded on the basis of the above observations that the impulsive events were caused by Venusian lightning.

Taylor, W. W. L.↗

Waveform Based Acoustic Emission Detection and Location of Matrix Cracking in Composites

The operation of damage mechanisms in a material or structure under load produces transient acoustic waves. These acoustic waves are known as acoustic emission (AE). In composites they can be caused by a variety of sources including matrix cracking, fiber breakage, and delamination. AE signals can be detected and analyzed to determine the location of the acoustic source by triangulation. Attempts are also made to analyze the signals to determine the type and severity of the damage mechanism. AE monitoring has been widely used for both laboratory studies of materials, and for testing the integrity of structures in the field. In this work, an advanced, waveform based AE system was used in a study of transverse matrix cracking in cross-ply graphite/epoxy laminates. This AE system featured broad band, high fidelity sensors, and high capture rate digital acquisition and storage of acoustic signals. In addition, analysis techniques based on plate wave propagation models were employed. These features provided superior source location and noise rejection capabilities.

Prosser, W. H.↗

On the competition between mixing rate and uniformity in a coaxial hydrodynamic focusing mixer

Fast microfluidic mixers for use with line-of-sight integrating detection schemes pose unique challenges. Such detectors typically cannot discriminate signal from slow moving (e.g. near internal walls) and fast-moving portions of the fluid stream. This convolves reaction rate dynamics with fluid flow residence time dynamics. Further, the small cross sections of typical three-dimensional hydrodynamic focusing devices lead to lower detection signals. The current study focuses on achieving both small time scales of mixing and homogenous residence times. This is achieved by injecting sample through a center capillary and hydrodynamically focusing using a sheath flow within a tapered second capillary. The current design also features a third, larger coaxial capillary. The mixed stream flows into the large cross-section of this third capillary to decelerate and expand the stream by up to 14-fold to improve line-of-sight signal strength of reaction products. Hydrodynamic focusing, mixing, and expansion are studied using analytical and numerical models and also studied experimentally using a fluorescein-iodide quenching reaction. The experimentally validated models are used to explore trade-offs between mixing rate and uniformity. For the first time, this work presents detailed analysis of the Lagrangian time history of species transport during mixing inside coaxial capillaries to measure mixing nonuniformity. The mixing region enables order 100 μs mixing times and residence time widths of the same order (140 μs).

42 ENGINEERING↗

Efficient Generalized Boundary Detection Using a Sliding Information Distance

In this work, we present a general machine learning algorithm for boundary detection within general signals based on an efficient, accurate, and robust approximation of the universal normalized information distance. Our approach uses an adaptive sliding information distance (SLID) combined with a wavelet-based approach for peak identification to locate the boundaries. Special emphasis is placed on developing an adaptive formulation of SLID to handle general signals with multiple unknown and/or drifting section lengths. Although specialized algorithms may outperform SLID when domain knowledge is available, these algorithms are limited to specific applications and do not generalize. SLID excels in these cases. We demonstrate the versatility and efficacy of SLID on a variety of signal types, including synthetically generated sequences of tokens, binary executables for reverse engineering applications, and time series of seismic events.

42 ENGINEERING↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Study of acoustic emission during mechanical tests of large flight weight tank structure

A polyphenylane oxide insulated, flight weight, subscale, aluminum tank was monitored for acoustic emissions during a proof test and during 100 cycles of environmental test simulating space flights. The use of a combination of frequency filtering and appropriate spatial filtering to reduce background noise was found to be sufficient to detect acoustic emission signals of relatively small intensity expected from subcritical crack growth in the structure. Several emission source locations were identified, including the one where a flaw was detected by post-test X-ray inspections. For most source locations, however, post-test inspections did not detect flaws; this was partially attributed to the higher sensitivity of the acoustic emission technique than any other currently available NDT method for detecting flaws.

Nakamura, Y.↗

Impulse Response Measurements Over Space-Earth Paths Using the GPS Coarse/Acquisition Codes

The impulse responses of radio transmission channels over space-earth paths were measured using the course/acquisition code signals from the Global Positioning System of satellites. The data acquisition system and signal processing techniques used to develop the impulse responses are described. Examples of impulse response measurements are presented. The results indicate that this measurement approach enables detection of multipath signals that are 20 dB or more below the power of the direct arrival. Channel characteristics that could be investigated with additional measurements and analyses are discussed.

SIGNAL PROCESSING↗

Fabry-Perot Interferometer for Column CO2

Global atmospheric CO2 measurements are essential to resolving significant discrepancies in our understanding of the global carbon budget and, hence, humankind's role in global climate change. The science measurement requirements for CO2 are extremely demanding (precision approx. 0.3%). No atmospheric chemical species has ever been measured from space with this precision. We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere. Preliminary design studies indicate that the method will be able to achieve the sensitivity and signal-to-noise detection required to measure column CO2 at the target specification. The objective of this program is to construct a prototype instrument for deployment on an aircraft to test the instrument performance and our ability to retrieve the data in the real atmosphere. To date we have assembled a laboratory bench system to begin testing the optical and electronic components. We are also measuring signal and noise levels in actual sunlight to evaluate component performance.

Heaps, William S.↗

Fabry-Perot Interferometer for Column CO2

Global atmospheric CO2 measurements are essential to resolving significant discrepancies in our understanding of the global carbon budget and, hence, humankind's role in global climate change. The science measurement requirements for CO2 are extremely demanding (precision is less than .3%). No atmospheric chemical species has ever been measured from space with this precision. We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere. Preliminary design studies indicate that the method will be able to achieve the sensitivity and signal-to-noise detection required to measure column CO2 at the target specification. The objective of this program is to construct a prototype instrument for deployment on an aircraft to test the instrument performance and our ability to retrieve the data in the real atmosphere. To date we have assembled a laboratory bench system to begin testing the optical and electronic components. We are also undertaking some measurements of signal and noise levels for actual sunlight reflecting from the ground in order to evaluate the potential of some components to meet the exacting requirements of this measurement.

Heaps, William S.↗

Constraining self-interacting dark matter with the full dataset of PandaX-II

Self-interacting dark matter (SIDM) is a leading candidate proposed to solve discrepancies between predictions of the prevailing cold dark matter theory and observations of galaxies. Many SIDM models predict the existence of a light force carrier that mediates strong dark matter self-interactions. If the mediator couples to the standard model particles, it could produce characteristic signals in dark matter direct detection experiments. We report searches for signals of SIDM models with a light mediator using the full dataset of the PandaX-II experiment, basing on a total exposure of 132 tonne-days. No significant excess over background is found, and our likelihood analysis leads to a strong upper limit on the dark matter-nucleon coupling strength. We further combine the PandaX-II constraints and those from observations of the light element abundances in the early universe, and show that direct detection and cosmological probes can provide complementary constraints on dark matter models with a light mediator.

79 ASTRONOMY AND ASTROPHYSICS↗