Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

STATISTICAL ANALYSIS OF IN-SERVICE ULTRASONIC INSPECTION DATA OF WASTE TANKS AT THE SAVANNAH RIVER Site-25021

Liquid radioactive waste has been stored in large, underground carbon steel tanks of 4.92-million-liter capacity at the United States Department of Energy's Savannah River Site (SRS) in Aiken, South Carolina since the 1950s. The In-service inspection of the Savannah River Site High Level Waste tanks will be reviewed as well as Ultrasonic testing (UT) for detecting for general wall thinning, pitting and interface attack through accessible regions of the tanks. In-service inspection [1] of the Savannah River Site (SRS) High Level Waste (HLW) tanks is an essential element of a comprehensive structural integrity program. Inspection confirmed the effectiveness of chemistry and temperature controls used to preclude localized and general corrosion of the tanks. Ultrasonic testing is used to detect general wall thinning, pitting and interface attack, as well as vertically oriented cracks through inspection of a 21.59 cm (8.5-in.) wide strip extending over the accessible height of the primary tank wall.

Harris, Stephen P.↗

Data Processing Unit Services Module

The Data Processing Services Module (DPUSM) provides the ability to perform pluggable compression, erasure coding, checksuming and other important file system operations within the Linux kernel. The pluggable provider interface allows for the use of hardware acceleration of those services. In-kernel file systems are then able to use these functions to use these accelerators to perform operations that are normally run on the processor, resulting in improved file system performance. Third parties will register "providers" with the DPUSM to communicate with their respective accelerators. Providers will implement functions with DPUSM API signatures so that the DPUSM can translate the data inputted by users of the DPUSM into data that providers recognize.

Lee, Jason↗

Factories-in-Space for Servicing, Assembly, & Manufacturing

Space 2.0 is a promising frontier for scientific exploration and the advancement of commerce, security, and technology. To effectively harness this potential, it is imperative to establish a multifunctional, resilient, and sustainable infrastructure that enables the maintenance and production of space-based systems. This capability is a driver for mission success on-orbit and for interplanetary travel to other celestial bodies. Central to this infrastructure is the establishment of orbital manufacturing facilities, referred to as 'factories-in-space' (FiS), which serve as critical nodes in the supply chain for the servicing, assembly, and production of systems essential for space-based operations. This paper presents a framework for understanding the key principles and design considerations underpinning FiS.

Technology↗

Large-Scale Adoption of Self-Synchronized Universal Droop Controller-Based Inverters to Enable Ancillary Services for Different Modes of Distribution System Operations

This work proposes the large-scale adoption of self-synchronized universal droop controller (SUDC)-based inverters to enable ancillary services for different modes of distribution system operations. The IEEE 123 bus system was modeled on a real-time simulator to study the performance of large-scale adoption of SUDC inverters in a distribution system. The resulting data collected shows that the voltage and the frequency were regulated within ranges, such as less than 5% for voltage and less than 0.5% for frequency, under different load variations and grid operations. Also, the black start was achieved within 0.4 s without any voltage overshoot. Through the simulation and validation on a small microgrid and the IEEE 123 bus distribution system, it can be concluded that the SUDC was successfully adopted to regulate the voltage and the frequency within the given ranges, and black start achieved within 1 s without voltage overshoot for different modes of distribution system operations.

14 SOLAR ENERGY↗

Overlooked trade-offs of environmentally protective hydropower operation: Impacts to ancillary services and greenhouse gas emissions

The relicensing of large hydropower projects in the United States often enforces environmental constraints such as minimum instream flows. These requirements can reduce hydropower's negative environmental impacts but may come at a cost of reduced electric generation and revenue. During the federal hydropower relicensing process, participants negotiate these environmental and economic trade-offs based on coarse models, often conflating impacts on generation and revenue, overlooking ancillary services (AS) markets, and ignoring potential greenhouse gas (GHG) implications. Using a case study of a 362-MW hydropower project in California, this research conducts higher resolution modelling to compare energy generation, AS provision, revenue, and GHG impacts of two hydropower operating regimes. The environmentally protective regime reduces average generation by 6% but increases AS provision by 2%. Total average revenue decreases by 3.5% under environmental constraints using current electricity prices (and by only 1.1% when modelled with projected 2030 electricity prices), indicating that generation impacts should not be equated with revenue impacts during relicensing. In the California electricity market, this reduced hydropower generation is replaced primarily by natural gas, resulting in an estimated 30,000 additional tons of CO 2 emitted annually. Furthermore, these positive and negative externalities are not adequately examined in the hydropower relicensing process.

13 HYDRO ENERGY↗

Residual service life of carbonated structures based on site non-destructive tests

Assessing the residual service life of carbonated reinforced concrete structures is typically conducted by measuring cover depths and carbonation of drilled cores, assuming the ''square root law'' for the progress of the carbonation front. Given the large spatial variability of carbonation depths, the required number of cores becomes prohibitive. A model is presented, based on numerous experimental data, by which the carbonation rate can be estimated by means of non-destructive site measurements of the air-permeability kT. A Weibull distribution of the carbonation rate K{sub c} is fitted to the results, which is a function of kT. Hence, for each kT value measured on site coupled with the cover depth x{sub d}, expected, optimistic and pessimistic values of the corrosion initiation time can be obtained without the need of drilling cores. The method is validated on 111 paired results of kT and x{sub d}, obtained on the emblematic Tokyo's Museum of Western Art.

36 MATERIALS SCIENCE↗

A multi-objective optimization model for cropland design considering profit, biodiversity, and ecosystem services

More sustainable agricultural methods are needed to alleviate the decreases in biodiversity and ecosystem services that have occurred because of industrial agriculture. One such method is the inclusion of alternative crops into croplands that can support biodiversity, reduce erosion and chemical runoff, and sequester carbon in the soil. However, the question of where such crops should be planted to balance competing economic and environmental objectives remains open. To this end, we develop a mixed-integer quadratically constrained program to optimize the layout of a cropland considering economic, biodiversity, greenhouse gas emissions, and water quality objectives. We include spatially varying fertilization as a decision variable in addition to crop establishment location. We further include the effect of core area and edges between different crops on biodiversity. To demonstrate the applicability of the model, we apply it to an example field, showing how the optimal cropland design changes as a decision-maker prioritizes different objectives and as edges have different impacts on biodiversity.

54 ENVIRONMENTAL SCIENCES↗

Grid ancillary services using electrolyzer-Based power-to-Gas systems with increasing renewable penetration

Increasing penetrations of renewable-based generation have led to a decrease in the bulk power system inertia and an increase in intermittency and uncertainty in generation. Energy storage is considered to be an important factor to help manage renewable energy generation at greater penetrations. Hydrogen is a viable long-term storage alternative. This paper analyzes and presents use cases for leveraging electrolyzer-based power-to-gas systems for electric grid support. The paper also discusses some grid services that may favor the use of hydrogen-based storage over other forms such as battery energy storage. Real-time controls are developed, implemented and demonstrated using a power-hardware-in-the-loop(PHIL) setup with a 225-kW proton-exchange-membrane electrolyzer stack. These controls demonstrate frequency and voltage support for the grid for different levels of renewable penetration (0%, 25%, and 50%). A comparison of the results shows the changes in respective frequencies and voltages as seen as different buses as a result of support from the electrolyzers and notes the impact on hydrogen production as a result of grid support. Finally, the paper discusses the practical nuances of implementing the tests with physical hardware, such as inverter/electrolyzer efficiency, as well as the related constraints and opportunities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilising demand response for distribution service restoration to achieve grid resiliency against natural disasters

The increased frequency of power outages due to natural disasters in recent years has highlighted the urgency of enhancing distribution grid resilience. The effective distribution service restoration (DSR) is an important measure for a resilient distribution grid. In this work, the authors demonstrate that DSR can be significantly improved by leveraging the flexibility provided by the inclusion of demand response (DR). The authors propose a framework for this by considering integrated control of household-level flexible appliances to vary the load demand at the distribution-grid level to improve DSR. The overall framework of the proposed system is modelled as a three-step method considering three optimization problems to (i) calculate feasible controllable aggregated load range for each bus, (ii) determine candidate buses to perform DR and their target load demand, and (iii) maintain the load level in each house through home energy management during the DSR, considering uncertainties in load and solar generation sequentially. The optimization problems are formulated as linear programming, mixed-integer linear programming, and multistage stochastic programming (solved using the stochastic dual dynamic programming) models. Finally, case studies performed in the IEEE 123-node test feeder show improvements in resilience in terms of energy restored compared to the restoration process without DR.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Multiport DC Transformer to Enable Flexible Scalable DC as a Service

The rapid adoption of new DC loads and sources, including photovoltaic arrays, DC fast charging of electric vehicle, battery energy storage and data centers, requires a large amount of DC power conversion. A majority of new deployments also necessitate the integration of multiple DC loads and sources at one site. The traditional approach to serve these new applications relies on multiple standard power converters, each dedicated to a source or load, and results in highly customized systems, with challenging control coordination, complex protection strategies, and poor scalability. Instead, this paper proposes the concept of a multiport DC transformer (MDCT) as a modular building block for realizing a flexible, scalable DC as a Service system and address this rapidly growing need. The MDCT uses the S4T to achieve very tight control of cycle-by-cycle energy exchange between multiple ports, with high efficiency. A single multiport converter replaces 4-6 distinct converters, integrates all energy flows and manages protection. As a result, a new layered control architecture is introduced to ensure stability and scalability of the MDCT, with multiple S4T power converter building blocks connected in parallel to realize a fully modular system and reach the target power levels.

30 DIRECT ENERGY CONVERSION↗

Steady-State Analysis of Microgrid Distributed Control Under Denial of Service Attacks

Distributed control is an effective method to coordinate multiple components in a microgrid. It usually has mandatory requirements for communication graph topology; changing the topology unexpectedly could disrupt the operation of a distributed controller. A denial of service (DoS) attack blocks communication channels to cause variations in communication graph. Unforeseen topology changes render a controller to receive incomplete system information. Control decisions made based on incorrect information can lead to significantly reduced grid supporting capability. As a result, the vital power balance between generation and load may be challenged. Determining power balance requires steady-state power flow analysis; however, the cyber-induced steady-state analysis is not well studied in the literature. Here, in this article, we show that a cyber–physical microgrid with unknown DoS attacks has augmented uncertain power flow equations, whose special structure creates new computational issue to determining power balance. To deal with the issue, we develop a novel cyber-induced microgrid model: the cyber–physical system is transformed into a pure physical model, where the disruption effects of DoS in the cyber layer are shown to be equivalent to the variations of the physical model parameters. With the transformed system, we develop a sufficient condition to ascertain the system power balance under unknown DoS attacks. In addition, practical insights for resilient distributed control design are shown as well.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Transactive Approach for Service Restoration Utilizing Customer Load Flexibility and Grid-Edge Resources

This paper develops a transactive energy system model to restore electricity to customers in an isolated distribution system after an outage. The model is developed to engage a variety of customer types - prosumers, flexible loads, critical/noncritical customers, and distributed generators - as active participants in the restoration process. Unlike many existing transactive approaches, the proposed model is developed for service restoration and accounts for various customer types and their autonomy and privacy through an iterative approach to determine the optimal market price, while maintaining systemlevel power flow and voltage constraints. The advantages of the proposed approach are numerically validated on a modified IEEE 123-bus test system.

distributed energy resources↗

Hybrid Imitation Learning for Real-Time Service Restoration in Resilient Distribution Systems

Self-healing capability is a critical factor for a resilient distribution system, which requires intelligent agents to automatically perform service restoration online, including network reconfiguration and reactive power dispatch. Here, the article proposes the imitation learning framework for training such an agent, where the agent will interact with an expert built based on the mixed-integer program to learn its optimal policy, and therefore significantly improve the training efficiency compared with exploration-dominant reinforcement learning (RL) methods. This significantly improved training efficiency makes the training problem under N-k scenarios tractable. A hybrid policy network is proposed to handle tie-line operations and reactive power dispatch simultaneously to further improve the restoration performance. The 33-bus and 119-bus systems with N-k disturbances are employed to conduct the training. The results indicate that the proposed method outperforms traditional RL algorithms such as the deep-Q network.

42 ENGINEERING↗

Ocelot: An Interactive, Efficient Distributed Compression-As-a-Service Platform With Optimized Data Compression Techniques

Large volumes of data generated by scientific simulations, genome sequencing, and other applications need to be moved among clusters for data collection/analysis. Data compression techniques have effectively reduced data storage and transfer costs. However, users' requirements on interactively controlling both data quality and compression ratios are non-trivial to fulfill. Here, we propose a novel Compression-as-a-Service (CaaS) platform called Ocelot with four important contributions: (1) It offers real-time visualization, interactive compression, and transfer of scientific datasets. (2) It incorporates new strategies for compressing diverse types of datasets more effectively than traditional methods. (3) It provides an effective method for estimating the compression ratio and execution time of compression tasks. (4) Experiments on multiple real-world datasets on geographically distributed computers show that Ocelot can significantly improve data transfer efficiency with a performance gain of more than 10x in computing clusters with relatively slow networks.

compression as a service (CaaS)↗

Resilience Analysis of DC Microgrids under Denial of Service Threats

This paper develops a resilience analysis framework to study the fault ride-through capability of direct current (DC) microgrids in unknown denial of service (DoS) cyber incidents. DoS can be a frequent threat to DC microgrids with advanced controllers that hinge on active information exchanges: it can paralyze data communications and cause control ineptness or even system instability. Furthermore, we show that temporal DoS incidents render the DC microgrid cyber-physical topology and parameters time-varying and cause them to jump between faulty conditions. As existing DC microgrid stability analysis results are primarily developed from time-invariant systems, they might not be valid for the DoS interrupted systems. In this paper, we seek to study whether a DC microgrid is resilient against time-varying unknown DoS incidents. The problem is formulated as a stability analysis problem for a system with randomly switching dynamics. Scalable conditions are developed to provide provable resilience guarantees. In addition, we exploit the special structure of the conditions to yield quantified resilience measure by convex optimization techniques. As a result, the measure can be used for the evaluation of the resilience of different DC microgrid design against DoS incidents. We demonstrate the effectiveness of the proposed work using simulation case studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mitigating Inter-Job Interference via Process-Level Quality-of-Service

Jobs on most high-performance computing (HPC) systems share the network with other concurrently executing jobs. Network sharing leads to contention that can severely degrade performance. Here we investigate the use of Quality of Service (QoS) mechanisms to reduce the negative impacts of network contention. QoS allows users to manage resource sharing between network flows and to provide bandwidth guarantees to specific flows. Our results show that careful use of QoS reduces the impact of network contention for specific jobs, resulting in up to a 40% performance improvement. In some cases, it completely eliminates the impact of contention. It achieves these improvements with limited negative impact to other jobs; any job that experiences performance loss typically degrades less than 5%, and often much less. Our approach can help ensure that HPC machines maintain high levels of throughput as per-node compute power continues to increase faster than network bandwidth.

97 MATHEMATICS AND COMPUTING↗

Opportunities for Energy, Water, and Waste Reduction at U.S. Forest Service Fire Camps

This report summarizes the results from energy efficiency, water efficiency, waste reduction and renewable energy site assessments conducted at fire camps located in the United States. A team led by the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) conducted the assessments with U.S. Forest Service (USFS) personnel during the summers of 2016 and 2017 as part of ongoing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Best Practices for Electric Vehicle Supply Equipment Installations in the National Parks: Challenges, Lessons Learned, Installation Best Practices, and Recommendations for the National Park Service

In recent years, the National Renewable Energy Laboratory (NREL) and the National Park Service (NPS) have partnered to undertake a variety of projects intended to provide electric vehicle supply equipment (EVSE) to park visitors. Efforts to install charging infrastructure in the national parks have been underway for almost a decade, with installation projects as part of NPS partnerships with several organizations. These projects have been initiated through a variety of funding sources, such as coordinated donations and agreements with other governmental agencies including the U.S. Department of Energy (DOE). This report captures challenges, lessons learned, and best practices from recent NPS EVSE projects based on interviews with NPS employees and stakeholders involved in the projects. The report summarizes notable takeaways and makes recommendations to help ensure the success of future charging installation projects. Preserving this information will be valuable for informing and ensuring the success of future charging installation efforts at national parks, as well as for organizations outside of NPS. Note that this report focuses on light-duty plug-in electric vehicle (EV) projects, though NPS is also pursuing medium- and heavy-duty EV efforts.

33 ADVANCED PROPULSION SYSTEMS↗