Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Repeat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Process Development of the Vaporizing Foil Actuator Welding Technique

The industrial focus on continuous improvement for products is leading design engineers to consider multi-material design concepts more frequently. The design concepts use the advantages of each material while simultaneously minimizing the drawbacks. It also allows for the overall weight of the products to be reduced. Some traditional joining methods, though, struggle to join dissimilar material combinations. A technique known as vaporizing foil actuator welding, which was developed around ten years ago, is a solid-state joining method that has the potential to overcome the barriers to dissimilar material joining. The biggest drawbacks of vaporizing foil actuator welding are that it is still exclusively used in laboratory settings and early in the technology development process. As such, there is not enough confidence in the process for it to be transitioned to manufacturing environments yet. This work begins by analyzing the current state of the technology and identifying a roadmap to achieve a transition to manufacturing. The analysis found that increased confidence in the technology requires sample to sample repeatability to be improved. Beyond that, the process also needs to be fully automated before it can be considered as a viable technique for mass production. In order to further develop the technique, a fully automated work cell was constructed. By removing the human element from the process, this cell helped identify iii the aspects which contribute to process variability. The positioning of the vaporizing foil actuator was identified as the most important factor in process stability. A small set of samples were made in the automated cell with the addition of one component epoxy adhesive around the perimeter of the weld. These samples showed improved process repeatability compared with the samples made without adhesive. This indicates that small amounts of adhesive may be critical in using the process in industrial settings. Additionally, work was performed with manual positioning and adhesive dispensing. This work found that a hybrid joint behaves like traditional weld bonding, where the addition of adhesive makes the joint stronger than if either of the two joining methods were used on their own. To realize this performance with vaporizing foil actuator welding, though, the adhesive needs to be protected from burning during the rapid compression of air during the impact process.

36 MATERIALS SCIENCE↗

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Evaluating Heat Extraction Performance of Closed-Loop Geothermal Systems with Thermally Conductive Enhancements in Conduction-Only Reservoirs: Preprint

We investigated the impact of disc-shaped and linear thermal enhancements on performance of closed-loop geothermal systems using steady-state and transient COMSOL numerical simulations. Thermal enhancements refer to thermally conductive material introduced in the rocks surrounding a wellbore to compensate for the relatively low rock thermal conductivity and increase heat extraction. Materials proposed include composite cements with thermally conductive additives such as metals or graphite to obtain overall cement thermal conductivities of 10 to 100x the rock thermal conductivity. Our simulation approach was modeling a subsegment (e.g., 100 m long) of a wellbore with idealized (e.g., perfect disc-shaped) thermal enhancements, and we report results as relative increase in heat extraction with respect to systems without thermal enhancements. We did not evaluate technical feasibility or cost of installing thermal enhancements. Simulations indicate that for 5-mm thick disc-shaped thermal enhancements with 5-m radius, repeated every 1 m along the wellbore and with thermal conductivity of 100x the rock thermal conductivity, the thermal output increases roughly 20% with respect to a closed-loop system without thermal enhancements. For fishbone structure thermal enhancements, we estimate a roughly 7% increase in thermal output for 5-m long radially outward pipes with half the radius of the main wellbore, repeated every 2.5 m, with thermal conductivity of 100x the rock thermal conductivity.

advanced geothermal systems↗

Effects of Coatings on Water Intrusion and Strain Gauge Durability in Submerged Fatigue Conditions: Preprint

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand the combined effects of moisture intrusion and mechanical fatigue on marine energy structures, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Measuring strain is critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions was not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure, strains, and strain gauge failure modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite fatigue testing↗

Effects of Strain Gauge Coatings on Water Intrusion in Submerged Composite Coupon Testing

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand their combined effects, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Strain measurements are critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions is not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure (SGF), strains, and SGF modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The coatings did not have significant effects on composite fatigue life or strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Assessment of Flow-Enhanced Sensors for Actinide Quantification in MSRs

This report serves as the deliverable for Milestone M2RS-22AN0401062 that is part of Work Package RS-22AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone is to assess the capabilities of flow-enhanced electrochemical sensors (FEES) to quantify actinides in molten salt reactors. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits in order to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. To support this work, Argonne constructed a molten salt flow system to serve as a testbed for the development of safeguards and process monitoring-relevant sensors in challenging molten salt flow conditions. Through extensive flow testing using UCl3-bearing salts, Argonne has been able to show that the FEES are able to make good measurements of salt composition. Concentration measurements with a mean absolute error of 0.09 wt% have been achieved for representative fuel salt mixtures across a range of UCl3 loadings. Repeatability was also good, with the relative standard deviation from repeated measurements being less than 1.0%. These sensors have also been shown to be able to measure the flow rate of the salt within the flow system’s transfer line. Although the accuracy of the sensors has been good, the sensors have thus far not been able to achieve performance good enough to satisfy the nuclear material accountancy requirements in 10 CFR 74. To do so, accuracy levels of 0.1% must be achieved; the FEES when operated in Argonne’s flow system have so far only been able to achieve relative errors of approximately 5.0%. Much of the error that has been observed at this stage is due to challenges in maintaining a stable salt composition in the molten salt flow system, and it is not believed that there are any inherent flaws in the sensor design. Nonetheless, the high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will likely be needed to push the measurement accuracy to the needed level.

Moore, Colin E.↗

Molecular determinants of cross-reactivity and potency by VH3-33 antibodies against the Plasmodium falciparum circumsporozoite protein

IGHV3-33 -encoded antibodies are prevalent in the human humoral response against the Plasmodium falciparum circumsporozoite protein (PfCSP). Among VH3-33 antibodies, cross-reactivity between PfCSP major repeat (NANP), minor (NVDP), and junctional (NPDP) motifs is associated with high affinity and potent parasite inhibition. However, the molecular basis of antibody cross-reactivity and the relationship with efficacy remain unresolved. Here, we perform an extensive structure-function characterization of 12 VH3-33 anti-PfCSP monoclonal antibodies (mAbs) with varying degrees of cross-reactivity induced by immunization of mice expressing a human immunoglobulin gene repertoire. We identify residues in the antibody paratope that mediate cross-reactive binding and delineate four distinct epitope conformations induced by antibody binding, with one consistently associated with high protective efficacy and another that confers comparably potent inhibition of parasite liver invasion. Our data show a link between molecular features of cross-reactive VH3-33 mAb binding to PfCSP and mAb potency, relevant for the development of antibody-based interventions against malaria.

59 BASIC BIOLOGICAL SCIENCES↗

An automated system for continuous monitoring of CO 2 geosequestration using multi-well offset VSP with permanent seismic sources and receivers: Stage 3 of the CO2CRC Otway Project

Time-lapse seismic is an essential tool for monitoring CO 2 injection into the subsurface but suffers from high cost and long intervals between surveys. An alternative approach is continuous monitoring using permanent sources and receivers capable of mapping CO 2 plume evolution on an almost daily basis and drastically reduce human effort, cost and survey turnaround. As part of the CO2CRC Otway project, a continuous monitoring system is employed to monitor a small (15,000 tonnes) CO 2 injection within the CO2CRC Otway Project. The permanent monitoring system employs distributed acoustic sensors (DAS) installed in boreholes as seismic receivers and seismic orbital vibrators (SOV) as seismic sources. The monitoring approach is based on vertical seismic profiling using five wells equipped with DAS cemented behind the casing and nine SOVs and is acquiring the data continuously in an autonomous manner. The data is then automatically processed on-site producing a seismic image every 2.5 days, which is then transmitted to a remote office. The data has good repeatability with NRMS of about ~10-15%.

58 GEOSCIENCES↗

High allelic diversity in Arabidopsis NLRs is associated with distinct genomic features

Plants rely on Nucleotide-binding, Leucine-rich repeat Receptors (NLRs) for pathogen recognition. Highly variable NLRs (hvNLRs) show remarkable intraspecies diversity, while their low-variability paralogs (non-hvNLRs) are conserved between ecotypes. At a population level, hvNLRs provide new pathogen-recognition specificities, but the association between allelic diversity and genomic and epigenomic features has not been established. Our investigation of NLRs in Arabidopsis Col-0 has revealed that hvNLRs show higher expression, less gene body cytosine methylation, and closer proximity to transposable elements than non-hvNLRs. hvNLRs show elevated synonymous and nonsynonymous nucleotide diversity and are in chromatin states associated with an increased probability of mutation. Diversifying selection maintains variability at a subset of codons of hvNLRs, while purifying selection maintains conservation at non-hvNLRs. How these features are established and maintained, and whether they contribute to the observed diversity of hvNLRs is key to understanding the evolution of plant innate immune receptors.

59 BASIC BIOLOGICAL SCIENCES↗

Structure-function analysis of microRNA 3'-end trimming by Nibbler

Nibbler (Nbr) is a 3'-to-5' exoribonuclease whose catalytic 3'-end trimming activity impacts microRNA (miRNA) and PIWI-interacting RNA (piRNA) biogenesis. Here, we report on structural and functional studies to decipher the contributions of Nbr’s N-terminal domain (NTD) and exonucleolytic domain (EXO) in miRNA 3'-end trimming. We have solved the crystal structures of the NTD core and EXO domains of Nbr, both in the apo-state. The NTD-core domain of Aedes aegypti Nbr adopts a HEAT-like repeat scaffold with basic patches constituting an RNA-binding surface exhibiting a preference for binding double-strand RNA (dsRNA) over single-strand RNA (ssRNA). Structure-guided functional assays in Drosophila S2 cells confirmed a principal role of the NTD in exonucleolytic miRNA trimming, which depends on basic surface patches. Gain-of-function experiments revealed a potential role of the NTD in recruiting Nbr to Argonaute-bound small RNA substrates. The EXO domain of A. aegypti and Drosophila melanogaster Nbr adopt a mixed α/β-scaffold with a deep pocket lined by a DEDDy catalytic cleavage motif. We demonstrate that Nbr’s EXO domain exhibits Mn2+-dependent ssRNA-specific 3'-to-5' exoribonuclease activity. Modeling of a 3' terminal Uridine into the catalytic pocket of Nbr EXO indicates that 2'-O-methylation of the 3'-U would result in a steric clash with a tryptophan side chain, suggesting that 2'-O-methylation protects small RNAs from Nbr-mediated trimming. Overall, our data establish that Nbr requires its NTD as a substrate recruitment platform to execute exonucleolytic miRNA maturation, catalyzed by the ribonuclease EXO domain.

59 BASIC BIOLOGICAL SCIENCES↗

De novo design of protein homodimers containing tunable symmetric protein pockets

Function follows form in biology, and the binding of small molecules requires proteins with pockets that match the shape of the ligand. For design of binding to symmetric ligands, protein homo-oligomers with matching symmetry are advantageous as each protein subunit can make identical interactions with the ligand. Here, we describe a general approach to designing hyperstable C2 symmetric proteins with pockets of diverse size and shape. We first designed repeat proteins that sample a continuum of curvatures but have low helical rise, then docked these into C2 symmetric homodimers to generate an extensive range of C2 symmetric cavities. We used this approach to design thousands of C2 symmetric homodimers, and characterized 101 of them experimentally. Of these, the geometry of 31 were confirmed by small angle X-ray scattering and 2 were shown by crystallographic analyses to be in close agreement with the computational design models. These scaffolds provide a rich set of starting points for binding a wide range of C2 symmetric compounds.

59 BASIC BIOLOGICAL SCIENCES↗

A case study: Comparing testers for means and variances in a balanced incomplete block design

In this article, we present a gauge R & R study that is different from the standard setup in several ways. A balanced incomplete block design (BIBD) was used to collect the data because the measurement is destructive. Besides addressing reproducibility, differences in repeatability (i.e., tester variances) were also of interest. Here we use Bayesian methods to analyze the study data to address whether the three tester means and variances are similar. We also consider what happens if the BIBD structure of the data and possibly different tester variances are ignored in analyzing the study data.

42 ENGINEERING↗

Constant Overhead Entanglement Distillation via Scrambling

High-fidelity quantum entanglement enables key quantum networking capabilities such as secure communication and distributed quantum computing, but long-distance entanglement distribution is limited by noise and loss. Entanglement distillation protocols address this problem by extracting high-fidelity Bell pairs from multiple noisy ones. The primary objective is minimizing the resource overhead: the number of noisy input pairs needed to distill each high-fidelity output pair. While protocols achieving optimal overhead are known in theory, they often require complex decoding operations that make practical implementation challenging. We circumvent this challenge by introducing protocols that use quantum scrambling—the spreading of quantum information under chaotic dynamics—through random Clifford operations. Based on this scrambling mechanism, our protocol maintains asymptotically constant overhead, independent of the desired output error rate $\bar{𝜖}$ , and can be implemented with shallow quantum circuits of depth 𝑂⁡(poly log log⁡ $\bar{𝜖}$ −1 ) and memory 𝑂⁡(poly log⁡ $\bar{𝜖}$ −1 ). Our protocol remains effective even with noisy quantum gates. By incorporating error correction, our protocol achieves state-of-the-art performance: starting with pairs of 10% initial infidelity, we require only seven noisy inputs per output pair to distill a single Bell pair with infidelity $\bar{𝜖}$ =10 −12 , substantially outperforming existing schemes. We demonstrate the utility of our protocols for quantum repeater networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the solubility of SARS-CoV-2 inhibitors to increase future prospects for clinical development

SARS-CoV-2 poses an ongoing threat to human health as variants continue to emerge. Several effective vaccines are available, but a diminishing number of Americans receive the updated vaccines (only 22% received the 2023 update). Public hesitancy towards vaccines and common occurrence of “breakthrough” infections (i.e., infections of vaccinated individuals) highlight the need for alternative methods to reduce viral transmission. SARS-CoV-2 enters cells by fusing its envelope with the target cell membrane in a process mediated by the viral spike protein, S. The S protein operates via a Class I fusion mechanism in which fusion between the viral envelope and host cell membrane is mediated by structural rearrangements of the S trimer. We previously reported lipopeptides derived from the C-terminal heptad repeat (HRC) domain of SARS-CoV-2 S that potently inhibit fusion by SARS-CoV-2, both in vitro and in vivo. These lipopeptides bear an attached cholesterol unit to anchor them in the membrane. Here, to improve prospects for experimental development and future clinical utility, we employed structure-guided design to incorporate charged residues at specific sites in the peptide to enhance aqueous solubility. This effort resulted in two new, potent lipopeptide inhibitors.

36 MATERIALS SCIENCE↗

LANL MPCL Measurement System Analysis: AMPTEC 630ES Igniter Tester / Ohmmeter

This comprehensive analysis aimed to evaluate the measurement capability of the AMPTEC 630ES Explosive Safety Igniter Tester, a critical tool for organizations engaged in the measurement of High Explosive components and related Electro-Explosive devices. With a history of notable calibration issues involving specific model numbers, the Metrology Program and Calibration Laboratory (MPCL) initiated an extensive Measurement System Analysis. The analysis's primary focus was to thoroughly quantify the various sources of measurement variability intrinsic to the calibration process. It centered on two pivotal aspects: repeatability (the variation observed when the same operator uses the same instrument) and reproducibility (the variation seen when different operators perform measurements). A secondary objective was to determine whether equipment usage and age had any impact on the instrument's performance.

47 OTHER INSTRUMENTATION↗