Decomposition of diverse solid inorganic matrices with molten ammonium bifluoride salt for constituent elemental analysis
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
There is a current trend in automation of leaching tests for trace elements in solid matrixes by use of flow injection based column approaches. However, as a result of the downscaled dimensions of the analytical manifold and execution of a single extraction at a time, miniaturized flow-through column approaches have merely found applications for periodic investigations of trace element mobility in highly homogeneous environmental solids. A novel flow-based configuration capitalized on stirred-flow cell extraction is proposed in this work for simultaneous fractionation of trace elements in three solid wastes with no limitation of sample amount up to 1.0 g. A two-step sequential extraction scheme involving water and acetic acid (or acetic acid/acetate buffer) is utilized for accurate assessment of readily mobilizable fractions of trace elements in fly ash samples. The W automated extraction system features high tolerance to flow rates ({<=} 6 mL min{sup -1}) and, as opposed to operationally defined batchwise methods, the solid to liquid ratio is not a critical parameter for, determination of overall readily leachable trace elements provided that exhaustive extraction is ensured. Analytical performance of the dynamic extractor is evaluated for fractionation analysis of a real coal fly ash and BCR-176R fly ash certified reference material. No significant differences were found at the 0.05 significance level between summation of leached concentrations in each fraction plus residue and concentration values of BCR-176R, thus revealing the accuracy of the automated method. Overall extractable pools of trace metals in three samples are separated in less than 115 min, even for highly contaminated ashes, versus 18-24 h per fraction in equilibrium leaching tests. The multiple stirred-flow cell assembly is thus suitable for routine risk assessment studies of industrial solid byproduct.
X-ray photoelectron spectroscopy was utilized to determine the valence band offset ({Delta}E{sub V}) of the InGaZnO{sub 4} (IGZO)/Si heterojunction. The IGZO films were grown on Si (100) using radio frequency magnetron sputtering. A value of {Delta}E{sub V} = 2.53 eV was obtained by using In 3d{sub 5/2}, Ga 2p{sub 3/2} core energy levels as references. Taking into consideration the experimental band gap of 3.20 eV of the IGZO, this would result in a conduction band offset {Delta}E{sub C} = 0.45 eV in this heterostructure.
Ba{sub 5}RTi{sub 3}Nb{sub 7}O{sub 30} (R = La, Nd, Sm) tungsten bronze ceramics were prepared, and the dielectric and ferroelectric properties were investigated over a broad temperature range. The relaxor nature was determined for all compositions in their permittivity curves, and a second anomaly of the dielectric loss (tan {delta}) was observed around 250 K in Ba{sub 5}NdTi{sub 3}Nb{sub 7}O{sub 30} and around 275 K in Ba{sub 5}SmTi{sub 3}Nb{sub 7}O{sub 30}. Both the maximum and remanent polarization tended to decrease and vanish at low temperatures in the ferroelectric phase for all compositions, which was referred to as the low temperature re-entrant relaxor behavior. The remanent polarization increased with decreasing temperature first and then reached the maximum value at the re-entrant temperature (T{sub r}). For Ba{sub 5}RTi{sub 3}Nb{sub 7}O{sub 30} (R = La, Nd, Sm), T{sub r} decreased with the radius of R{sup 3+} cations and the applied field amplitude.
A semiconductor bridge (SCB) is a silicon device, used in explosive systems as the electrical initiator element. In recent years, SCB plasma has been extensively studied, both electrically and using fast photography and spectroscopic imaging. However, the value of the pressure buildup at the bridge remains unknown. In this study, we operated SCB devices in water and, using shadow imaging and reference beam interferometry, obtained the velocity of the shock wave propagation and distribution of the density of water. These results, together with a self-similar hydrodynamic model, were used to calculate the pressure generated by the exploding SCB. In addition, the results obtained showed that the energy of the water flow exceeds significantly the energy deposited into the exploded SCB. The latter can be explained by the combustion of the aluminum and silicon atoms released in water, which acts as an oxidizing medium.
We present a method to obtain numerically accurate values of configurational free energies of semiflexible macromolecular systems, based on the technique of thermodynamic integration combined with normal-mode analysis of a reference system subject to harmonic constraints. Compared with previous free-energy calculations that depend on a reference state, our approach introduces two innovations, namely, the use of internal coordinates to constrain the reference states and the ability to freely select these reference states. As a consequence, it is possible to explore systems that undergo substantially larger fluctuations than those considered in previous calculations, including semiflexible biopolymers having arbitrary ratios of contour length L to persistence length P. To validate the method, high accuracy is demonstrated for free energies of prime DNA knots with L/P = 20 and L/P = 40, corresponding to DNA lengths of 3000 and 6000 base pairs, respectively. We then apply the method to study the free-energy landscape for a model of a synaptic nucleoprotein complex containing a pair of looped domains, revealing a bifurcation in the location of optimal synapse (crossover) sites. This transition is relevant to target-site selection by DNA-binding proteins that occupy multiple DNA sites separated by large linear distances along the genome, a problem that arises naturally in gene regulation, DNA recombination, and the action of type-II topoisomerases.
We describe a method for simultaneous measurements of the real and imaginary parts of the field scattered by single nanoparticles illuminated by a laser beam, exploiting a self-reference interferometric scheme relying on the fundamentals of the Optical Theorem. Results obtained with calibrated spheres of different materials are compared to the expected values obtained through a simplified analytical model without any free parameters, and the method is applied to a highly polydisperse water suspension of Poly(D,L-lactide-co-glycolide) nanoparticles. Advantages with respect to existing methods and possible applications are discussed.
The precision obtainable in phenomenological applications of chiral perturbation theory is currently limited by our lack of knowledge on the low-energy constants (LECs). The assumption that the most important contributions to the LECs come from the dynamics of the low-lying resonances, often referred to as the resonance saturation hypothesis, has stimulated the use of large-N{sub C} resonance Lagrangians in order to obtain explicit values for the LECs. We study the validity of the resonance saturation assumption at the next-to-leading order in the 1/N{sub C} expansion within the framework of resonance chiral theory. We find that, by imposing QCD short-distance constraints, the chiral couplings can be written in terms of the resonance masses and couplings and do not depend explicitly on the coefficients of the chiral operators in the Goldstone boson sector of resonance chiral theory. As we argue, this is the counterpart formulation of the resonance saturation statement in the context of the resonance Lagrangian. Going beyond leading order in the 1/N{sub C} counting allows us to keep full control of the renormalization scale dependence of the LEC estimates.
Abstract Automated water level measurements collected using vented pressure transducers in deep wells screened across the water table may exhibit a greater response to barometric pressure changes than the true water level. The cause was hypothesized to be disequilibrium in barometric pressure between the wellbores and land surface due to air exchange with the deep vadose zone. In this study, vented and nonvented pressure transducers were installed and operated simultaneously in two deep wells screened across the water table. A vent tube open to the atmosphere at land surface allowed for barometric compensation of the vented transducers. Two nonvented transducers were installed in each well, one submerged in the water and one above the water surface. The difference in readings allowed for barometric compensation. Manual measurements were also collected. It was confirmed that measurements from the vented transducers exhibited greater variability in response to barometric pressure changes than the nonvented transducers and manual measurements. Comparison of the downhole barometric pressure measurements to values from a nearby meteorology station showed the response in the wells to changes in barometric pressure was time‐lagged and attenuated. Thus, the reference pressure from land surface supplied to the vented transducers was not representative of the air pressure within the wells. This caused fluctuations of the transducer readings in response to barometric pressure changes to be greater than the true water level change. This issue can be resolved by the use of nonvented pressure transducers.
Optical properties of near-surface kidney tissue were monitored in order to assess response during reperfusion to long (20 minutes) versus prolonged (150 minutes) ischemia in an in vivo rat model. Specifically, autofluorescence images of the exposed surfaces of both the normal and the ischemic kidneys were acquired during both injury and reperfusion alternately under 355 nm and 266 nm excitations. The temporal profile of the emission of the injured kidney during the reperfusion phase under 355 nm excitation was normalized to that under 266 nm as a means to account for changes in tissue optical properties independent of ischemia as well as changes in the illumination/collection geometrical parameters in future clinical implementation of this technique using a hand-held probe. The scattered excitation light signal was also evaluated as a reference signal and found to be inadequate. Characteristic time constants were extracted using fit to a relaxation model and found to have larger mean values following 150 minutes of injury. The mean values were then compared with the outcome of a chronic survival study where the control kidney had been removed. Rat kidneys exhibiting longer time constants were much more likely to fail. This may lead to a method to assess kidney viability and predict its ability to recover in the initial period following transplantation or resuscitation.
Explicit Runge–Kutta (RK) methods are susceptible to a reduction in the observed order of convergence when applied to an initial boundary value problem with time-dependent boundary conditions. We study conditions on explicit RK methods that guarantee high order convergence for linear problems; we refer to these conditions as weak stage order conditions. We prove a general relationship between the method’s order, weak stage order, and number of stages. Furthermore, we derive explicit RK methods with high weak stage order and demonstrate, through numerical tests, that they avoid the order reduction phenomenon up to any order for linear problems and up to order three for nonlinear problems.
This is code to reproduce and build on OOD detection from the paper "Out of Distribution Detection with Neural Network Anchoring". Our goal here is to exploit heteroscedastic temperature scaling as a calibration strategy for out of distribution (OOD) detection. Heteroscedasticity here refers to the fact that the optimal temperature parameter for each sample can be different, as opposed to conventional approaches that use the same value for the entire distribution. To enable this, we propose a new training strategy called anchoring that can estimate appropriate temperature values for each sample, leading to state-of-the-art OOD detection performance across several benchmarks. Using NTK theory, we show that this temperature function estimate is closely linked to the epistemic uncertainty of the classifier, which explains its behavior. In contrast to some of the best-performing OOD detection approaches, our method does not require exposure to additional outlier datasets, custom calibration objectives, or model ensembling. Through empirical studies with different OOD detection settings - far OOD, near OOD, and semantically coherent OOD - we establish a highly effective OOD detection approach.
A general drop size distribution (DSD) normalization method is formulated in terms of generalized power series relating any DSD moment to any number and combination of reference moments. This provides a consistent framework for comparing the variability of normalized DSD moments using different sets of reference moments, with no explicit assumptions about the DSD functional form (e.g., gamma). It also provides a method to derive any unknown moment plus an estimate of its uncertainty from one or more known moments, which is relevant to remote sensing retrievals and bulk microphysics schemes in weather and climate models. Herein, the approach is applied to a large dataset of disdrometer-observed and bin microphysics-modeled DSDs. As expected, the spread of normalized moments decreases as the number of reference moments is increased, quantified by the logarithmic standard deviation of the normalized moments, σ. Averaging σ for all combinations of reference moments and normalized moments of integer order 0–10, 42.9%, 81.3%, 93.7%, and 96.9% of spread are accounted for applying one-, two-, three-, and four-moment normalizations, respectively. Thus, DSDs can be well characterized overall using three reference moments, whereas adding a fourth reference moment contributes little independent information. The spread of disdrometer-observed DSD moments from uncertainty associated with drop count statistics generally lies between values of σ using two- and three-moment normalizations. However, this uncertainty has little impact on the derived DSD scaling relationships or σ when considered.
This report documents conceptual design development for the Deep Borehole Field Test (DBFT), mainly the test packages (not containing waste) and the system for demonstrating emplacement and retrieval of those packages in the Field Test Borehole (FTB). For the DBFT to have demonstration value, it must be based on conceptualization of a deep borehole disposal (DBD) system for specific waste forms. This document therefore describes a current reference DBD concept, and analyzes key design options for disposal, to guide selection of options for the DBFT. The most important of these options is the emplacement mode, i.e. whether packages are emplaced using a wireline or a string of drill pipe (with a drill rig). This choice is analyzed using cost and risk models, in Sections 5 and 6. Other emplacement mode options are also identified and discussed. The reference DBD concept and the analysis of waste packaging and emplacement options, are used to develop requirements and assumptions for the DBFT and to recommend DBFT specifications. Design issues are identified, and priorities are developed for further conceptual design development and additional engineering analysis, anticipating future design activities. Conceptual design development is part of a process that proceeds in three stages: 1) conceptual design including feasibility studies; 2) preliminary design that includes technical and cost information necessary for final design; and 3) final design sufficient for fabrication or construction. The DBFT engineering demonstration will follow such an evolution. Whereas design evolution typically begins with bench-scale and pilot-scale investigations proceeding to conceptual, preliminary, and final designs, the DBFT can proceed directly to design because of extensive previous work and published literature on scientific drilling, characterization methods, waste packaging and handling, industrial deep-hole drilling and construction, and downhole operations. Hence it is anticipated that this report will lead to completion of conceptual design, then preliminary and final design, fabrication and testing, and demonstration of waste emplacement in a deep borehole.
This handbook is an update of the 1993 version of the Data Collection Handbook and the Radionuclide Transfer Factors Report to support modeling the impact of radioactive material in soil. Many new parameters have been added to the RESRAD Family of Codes, and new measurement methodologies are available. A detailed review of available parameter databases was conducted in preparation of this new handbook. This handbook is a companion document to the user manuals when using the RESRAD (onsite) and RESRAD-OFFSITE code. It can also be used for RESRAD-BUILD code because some of the building-related parameters are included in this handbook. The RESRAD (onsite) has been developed for implementing U.S. Department of Energy Residual Radioactive Material Guidelines. Hydrogeological, meteorological, geochemical, geometrical (size, area, depth), crops and livestock, human intake, source characteristic, and building characteristic parameters are used in the RESRAD (onsite) code. The RESRAD-OFFSITE code is an extension of the RESRAD (onsite) code and can also model the transport of radionuclides to locations outside the footprint of the primary contamination. This handbook discusses parameter definitions, typical ranges, variations, and measurement methodologies. It also provides references for sources of additional information. Although this handbook was developed primarily to support the application of RESRAD Family of Codes, the discussions and values are valid for use of other pathway analysis models and codes.
Data are not inherently information. Without context, data are just numbers, figures, names, or points on a line. By assigning context to data, we can validate ideas, form opinions, and generate knowledge. This is an important distinction to information scientists, as we recognize that the context in which we keep our data plays a big part in generating its value. The mechanisms used to assign this context often include their own data, supplemental to the data being described and defining semantic relationships, commonly referred to as metadata. This paper provides the status of the DOE Geothermal Data Repository (DOE GDR), including recent efforts to tether data submissions to information, discusses the important distinction between data and information, outlines a path to generate useful knowledge from raw data, and details the steps taken in order to become a node on the National Geothermal Data System (NGDS).
Purpose: To investigate the glandular dose magnitudes and characteristics resulting from image acquisition using a dedicated breast computed tomography (BCT) clinical prototype imaging system. Methods: The x-ray spectrum and output characteristics of a BCT clinical prototype (Koning Corporation, West Henrietta, NY) were determined using empirical measurements, breast phantoms, and an established spectrum model. The geometry of the BCT system was replicated in a Monte Carlo-based computer simulation using the GEANT4 toolkit and was validated by comparing the simulated results for exposure distribution in a standard 16 cm CT head phantom with those empirically determined using a 10 cm CT pencil ionization chamber and dosimeter. The computer simulation was further validated by replicating the results of a previous BCT dosimetry study. Upon validation, the computer simulation was modified to include breasts of varying sizes and homogeneous compositions spanning those encountered clinically, and the normalized mean glandular dose resulting from BCT was determined. Using the system's measured exposure output determined automatically for breasts of different size and density, the mean glandular dose for these breasts was computed and compared to the glandular dose resulting from mammography. Finally, additional Monte Carlo simulations were performed to study how the glandular dose values vary within the breast tissue during acquisition with both this BCT prototype and a typical craniocaudal (CC) mammographic acquisition. Results: This BCT prototype uses an x-ray spectrum with a first half-value layer of 1.39 mm Al and a mean x-ray energy of 30.3 keV. The normalized mean glandular dose for breasts of varying size and composition during BCT acquisition with this system ranges from 0.278 to 0.582 mGy/mGy air kerma with the reference air kerma measured in air at the center of rotation. Using the measured exposure outputs for the tube currents automatically selected by the system for the breasts of different sizes and densities, the mean glandular dose for a BCT acquisition with this prototype system varies from 5.6 to 17.5 mGy, with the value for a breast of mean size and composition being 17.06 mGy. The glandular dose throughout the breast tissue of this mean breast varies by up to {+-}50% of the mean value. During a typical CC view mammographic acquisition of an equivalent mean breast, which typically results in a mean glandular dose of 2.0-2.5 mGy, the glandular dose throughout the breast tissue varies from {approx}15% to {approx}400% of the mean value. Conclusions: Acquisition of a BCT image with the automated tube output settings for a mean breast with the Koning Corp. clinical prototype results in mean glandular dose values approximately equivalent to three to five two-view mammographic examinations for a similar breast. For all breast sizes and compositions studied, this glandular dose ratio between acquisition with this BCT prototype and two-view mammography ranges from 1.4 to 7.2. In mammography, portions of the mean-sized breast receive a considerably higher dose than the mean value for the whole breast. However, only a small portion of a breast undergoing mammography would receive a glandular dose similar to that from BCT.
Purpose: The purpose of this study was to evaluate the inverse planning simulated annealing (IPSA) software for the optimization of dose distribution in patients with cervix carcinoma treated with MRI-based pulsed-dose rate intracavitary brachytherapy. Methods and Materials: Thirty patients treated with a technique using a customized vaginal mold were selected. Dose-volume parameters obtained using the IPSA method were compared with the classic manual optimization method (MOM). Target volumes and organs at risk were delineated according to the Gynecological Brachytherapy Group/European Society for Therapeutic Radiology and Oncology recommendations. Because the pulsed dose rate program was based on clinical experience with low dose rate, dwell time values were required to be as homogeneous as possible. To achieve this goal, different modifications of the IPSA program were applied. Results: The first dose distribution calculated by the IPSA algorithm proposed a heterogeneous distribution of dwell time positions. The mean D90, D100, and V100 calculated with both methods did not differ significantly when the constraints were applied. For the bladder, doses calculated at the ICRU reference point derived from the MOM differed significantly from the doses calculated by the IPSA method (mean, 58.4 vs. 55 Gy respectively; p = 0.0001). For the rectum, the doses calculated at the ICRU reference point were also significantly lower with the IPSA method. Conclusions: The inverse planning method provided fast and automatic solutions for the optimization of dose distribution. However, the straightforward use of IPSA generated significant heterogeneity in dwell time values. Caution is therefore recommended in the use of inverse optimization tools with clinical relevance study of new dosimetric rules.