Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reference Values”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

An Optimal Power Control Strategy for Grid-Following Inverters in a Synchronous Frame

This work proposes a power control strategy based on the linear quadratic regulator with optimal reference tracking (LQR-ORT) for a three-phase inverter-based generator (IBG) using an LCL filter. The use of an LQR-ORT controller increases robustness margins and reduces the quadratic value of the power error and control inputs during transient response. A model in a synchronous reference frame that integrates power sharing and voltage–current (V–I) dynamics is also proposed. This model allows for analyzing closed-loop eigenvalue location and robustness margins. The proposed controller was compared against a classical droop approach using proportional-resonant controllers for the inner loops. Mathematical analysis and hardware-in-the-loop (HIL) experiments under variations in the LCL filter components demonstrate fulfillment of robustness and performance bounds of the LQR-ORT controller. Experimental results demonstrate accuracy of the proposed model and the effectiveness of the LQR-ORT controller in improving transient response, robustness, and power decoupling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Image Correlation Pattern Optimization for Micro-Scale In-Situ Strain Measurements

The accuracy and precision of digital image correlation (DIC) is a function of three primary ingredients: image acquisition, image analysis, and the subject of the image. Development of the first two (i.e. image acquisition techniques and image correlation algorithms) has led to widespread use of DIC; however, fewer developments have been focused on the third ingredient. Typically, subjects of DIC images are mechanical specimens with either a natural surface pattern or a pattern applied to the surface. Research in the area of DIC patterns has primarily been aimed at identifying which surface patterns are best suited for DIC, by comparing patterns to each other. Because the easiest and most widespread methods of applying patterns have a high degree of randomness associated with them (e.g., airbrush, spray paint, particle decoration, etc.), less effort has been spent on exact construction of ideal patterns. With the development of patterning techniques such as microstamping and lithography, patterns can be applied to a specimen pixel by pixel from a patterned image. In these cases, especially because the patterns are reused many times, an optimal pattern is sought such that error introduced into DIC from the pattern is minimized. DIC consists of tracking the motion of an array of nodes from a reference image to a deformed image. Every pixel in the images has an associated intensity (grayscale) value, with discretization depending on the bit depth of the image. Because individual pixel matching by intensity value yields a non-unique scale-dependent problem, subsets around each node are used for identification. A correlation criteria is used to find the best match of a particular subset of a reference image within a deformed image. The reader is referred to references for enumerations of typical correlation criteria. As illustrated by Schreier and Sutton and Lu and Cary systematic errors can be introduced by representing the underlying deformation with under-matched shape functions. An important implication, as discussed by Sutton et al., is that in the presence of highly localized deformations (e.g., crack fronts), error can be reduced by minimizing the subset size. In other words, smaller subsets allow the more accurate resolution of localized deformations. Contrarily, the choice of optimal subset size has been widely studied and a general consensus is that larger subsets with more information content are less prone to random error. Thus, an optimal subset size balances the systematic error from under matched deformations with random error from measurement noise. The alternative approach pursued in the current work is to choose a small subset size and optimize the information content within (i.e., optimizing an applied DIC pattern), rather than finding an optimal subset size. In the literature, many pattern quality metrics have been proposed, e.g., sum of square intensity gradient (SSSIG), mean subset fluctuation, gray level co-occurrence, autocorrelation-based metrics, and speckle-based metrics. The majority of these metrics were developed to quantify the quality of common pseudo-random patterns after they have been applied, and were not created with the intent of pattern generation. As such, it is found that none of the metrics examined in this study are fit to be the objective function of a pattern generation optimization. In some cases, such as with speckle-based metrics, application to pixel by pixel patterns is ill-conditioned and requires somewhat arbitrary extensions. In other cases, such as with the SSSIG, it is shown that trivial solutions exist for the optimum of the metric which are ill-suited for DIC (such as a checkerboard pattern). In the current work, a multi-metric optimization method is proposed whereby quality is viewed as a combination of individual quality metrics. Specifically, SSSIG and two auto-correlation metrics are used which have generally competitive objectives. Thus, each metric could be viewed as a constraint imposed upon the others, thereby precluding the achievement of their trivial solutions. In this way, optimization produces a pattern which balances the benefits of multiple quality metrics. The resulting pattern, along with randomly generated patterns, is subjected to numerical deformations and analyzed with DIC software. The optimal pattern is shown to outperform randomly generated patterns.

Bomarito, G. F.↗

Monte Carlo study of correction factors for the use of plastic phantoms in clinical electron dosimetry

In some recent dosimetry protocols, plastic is allowed as a phantom material for the determination of an absorbed dose to water in electron beams, especially for low energy with beam qualities R{sub 50}<4 g/cm{sup 2}. In electron dosimetry with plastic, a depth-scaling factor, c{sub pl}, and a chamber-dependent fluence correction factor, h{sub pl}, are needed to convert the dose measured at a water-equivalent reference depth in plastic to a dose at a reference depth in water. The purpose of this study is to calculate correction factors for the use of plastic phantoms for clinical electron dosimetry using the EGSnrc Monte Carlo code system. RMI-457 and WE-211 were investigated as phantom materials. First the c{sub pl} values for plastic materials were calculated as a function of a half-value depth of maximum ionization, I{sub 50}, in plastic. The c{sub pl} values for RMI-457 and WE-211 varied from 0.992 to 1.002 and from 0.971 to 0.979, respectively, in a range of nominal energies from 4 MeV to 18 MeV, and varied slightly as a function of I{sub 50} in plastic. Since h{sub pl} values depend on the wall correction factor, P{sub wall}, of the chamber used, they are evaluated using a pure electron fluence correction factor, {phi}{sub pl}{sup w}, and P{sub wall}{sup w} and P{sub wall}{sup pl} for a combination of water or plastic phantoms and plane-parallel ionization chambers (NACP-02, Markus and Roos). The {phi}{sub pl}{sup w} and P{sub wall} (P{sub wall}{sup w} and P{sub wall}{sup pl}) values were calculated as a function of the water-equivalent depth in plastic materials and at a reference depth as a function of R{sub 50} in water, respectively. The {phi}{sub pl}{sup w} values varied from 1.024 at 4 MeV to 1.013 at 18 MeV for RMI-457, and from 1.025 to 1.016 for WE-211. P{sub wall}{sup w} values for plane-parallel chambers showed values in the order of 1.5% to 2% larger than unity at 4 MeV, consistent with earlier results. The P{sub wall}{sup pl} values of RMI-457 and WE-211 were close to unity for all the energy beams. Finally, calculated h{sub pl} values of RMI-457 ranged from 1.009 to 1.005, from 1.010 to 1.003 and from 1.011 to 1.007 for NACP-02, Markus and Roos chambers, respectively, in the range of 4 MeV to 18 MeV, and the values of WE-211 were 1.010 to 1.004, 1.010 to 1.004 and 1.012 to 1.008, respectively. The calculated h{sub pl} values for the Markus chamber agreed within their combined uncertainty with the measured data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Meteorological accuracy requirements for aerobraking orbital transfer vehicles

Accuracy requirements for the prediction of atmospheric density for a transfer mission from geosynchronous orbit to low earth orbit using an aerobraking orbital transfer vehicle are presented. Uniform density variations such as would occur seasonally and diurnally were considered as well as density 'pockets' similar to what may have been observed on some of the Space Shuttle Orbiter entry flights. Variations in the lift-to-drag ratio from 0.3 to 1.5 were evaluated, with the values of the ratio of the vehicle weight to the product of the aerodynamic lift coefficient and the aerodynamic reference area ranging from 20 to 100 lb/sq ft. The results of the study indicated no problems for the range of lift-to-drag ratio values considered for uniform density variations of at least + or - 50 percent. However, density 'pockets' created problems if variations of + or - 30 percent from nominal occurred over altitude ranges of 1,000 to 10,000 ft.

Skalecki, L. M.↗

Comparative accuracy of qualitative and quantitative 18F-FDG PET/CT analysis in detection of lymph node metastasis from anal cancer

Purpose: To compare the diagnostic performance of qualitative and quantitative 18F-FDG PET/CT in detection of regional and distant lymph node metastasis in patients with anal cancer. Methods: Between 2004 and 2017, 28 patients with anal cancer who had staging PET/CT and pathological assessment of suspicious lymph nodes were included. For qualitative analysis, positive lymph nodes were defined as uptake visually higher than the liver reference uptake. For quantitative study, lymph nodes were contoured to determine maximum standard uptake value (SUV{sub max}) and metabolic tumor volume (MTV). Receiver operating characteristic (ROC) curves were plotted to extract the optimal cut-offs and area under the curve (AUC) of SUV{sub max}, lesion to background (L/B) ratio, short axis diameter (SAD), and MTV of lymph nodes. Histopathologic analysis was a reference standard. Results: A total of 28 lymph nodes (24 inguinal, 2 external iliac, 1 internal iliac, and 1 paraaortic nodes) in 28 patients on PET/CT were included. With the qualitative visual analysis, 19 patients were categorized as positive for nodal metastasis with sensitivity, specificity, and accuracy of 85%, 75%, and 82%. The optimal SUV{sub max} and L/B ratio cut-offs were 2.6 and 1.0 with both sensitivity and specificity of 95% and 75% (AUC of SUV{sub max} = 0.893, AUC of L/B ratio = 0.912). Using the best cut-off of 1.6 cm for SAD and 3.65 cm{sup 3} for MTV, both sensitivity and specificity were 80% and 100% (AUC of SAD = 0.950, AUC of MTV = 0.931). Conclusions: SUV{sub max} optimization may be helpful in enhancing the diagnostic accuracy of 18F-FDG PET/CT in nodal staging patients with anal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

Primary and post-chemoradiotherapy staging using MRI in rectal cancer: the role of diffusion imaging in the assessment of perirectal infiltration

Purpose: To analyze changes in MRI diagnostic accuracy in main rectal tumor (T) evaluation resulting from the use of diffusion-weighted imaging (DWI), according to the degree of experience of the radiologist. Methods: This is a cross-sectional study of a database including one hundred 1.5 T MRI records (2011–2016) from patients with biopsy-proven rectal cancer, including primary staging and post-chemoradiotherapy follow-up. All cases were individually blindedly reviewed by ten radiologists: three experienced in rectal cancer, three specialized in other areas, and four residents. Each case was assessed twice to detect perirectal infiltration: first, evaluating just high-resolution T2-weighted sequences (HRT2w); second, evaluation of DWI plus HRT2w sequences. Results were pooled by experience, calculating accuracy (area under ROC curve), sensitivity and specificity, predictive values, likelihood ratios, and overstaging/understaging. Histology of surgical specimens provided the reference standard. Results: DWI significantly improved specificity by experienced radiologists in primary staging (63.2% to 75.9%) and, to a lesser extent, positive likelihood ratio (2.06 to 2.87); minimal changes were observed post-chemoradiotherapy, with a slight decrease of accuracy (0.657 to 0.626). Inexperienced radiologists showed a similar pattern, but with slight enhancement post-chemoradiotherapy (accuracy 0.604 to 0.621). Residents experienced small changes, with increased sensitivity/decreased specificity in both primary (69% to 72%/67.2% to 64.7%) and post-chemoradiotherapy (68.1% to 73.6%/47.3% to 44.6%) staging. Conclusions: Adding DWI to HRT2w significantly improved specificity for the detection of perirectal infiltration at primary staging by experienced radiologists and also by inexperienced ones, although to a lesser extent. In the post-neoadjuvant treatment subgroup, only minimal changes were observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determining P, S, Br, and I content in uranium by triple quadrupole inductively coupled plasma mass spectrometry

The trace impurities of a uranium ore concentrate (UOC) can be examined to determine mine source, methods of production, and quality. This study presents a method to determine the concentration of halides and main group elements, specifically P, S, Br and I, utilizing triple quadrupole inductively coupled plasma–mass spectrometry. These analytes were measured in a uranium matrix to simulate a UOC sample. The concentrations determined with this method showed agreement with known values. Solutions with and without uranium were compared. A UOC certified reference material, CUP-2, was analyzed to further demonstrate the effectiveness of the method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Sample screening of uranium ore concentrates using portable spectrophotometers: investigating the correlation between visible colors and chemical signatures

A research collaboration between the Japan Atomic Energy Agency and the Department of Energy’s National Nuclear Security Administration examined nuclear forensic signatures and analytical methods for tracing the origins of uranium ore concentrates (UOCs). Here, this study focuses on utilizing portable spectrophotometers capable of reflectance measurements in the visible light spectrum as a potential rapid screening tool for nuclear forensics analysis. Unlike laboratory-based near-infrared spectroscopy or digital image analysis, this research investigated the potential to correlate visible color measurements with key nuclear forensics signatures using seven types of UOC samples with known origins and three UOC certified reference materials. Results demonstrated that distinct color groups, quantified using CIELAB values, correlated with major uranium compounds. Furthermore, the findings indicated that trace elements can influence the UOC colors, providing additional insights into material characteristics. Although this approach requires further validation across a broader range of UOC species, this study demonstrated that simple colorimetric analysis using visible spectrophotometry, which does not require complex sample preparation or data processing, can serve as a practical and novel rapid tool for preliminary screening and attribution in nuclear forensics investigations.

and nuclear chemistry↗

A new comprehensive method for detection of livestock-related pathogenic viruses using a target enrichment system

Highlights: • Development of a comprehensive method to detect viruses using SureSelect system. • A method by which almost the full length of the viral genome can be determined without virus isolation. • Widely available methods for comprehensive analysis of virus genomic information. We tested usefulness of a target enrichment system SureSelect, a comprehensive viral nucleic acid detection method, for rapid identification of viral pathogens in feces samples of cattle, pigs and goats. This system enriches nucleic acids of target viruses in clinical/field samples by using a library of biotinylated RNAs with sequences complementary to the target viruses. The enriched nucleic acids are amplified by PCR and subjected to next generation sequencing to identify the target viruses. In many samples, SureSelect target enrichment method increased efficiencies for detection of the viruses listed in the biotinylated RNA library. Furthermore, this method enabled us to determine nearly full-length genome sequence of porcine parainfluenza virus 1 and greatly increased Breadth, a value indicating the ratio of the mapping consensus length in the reference genome, in pig samples. Our data showed usefulness of SureSelect target enrichment system for comprehensive analysis of genomic information of various viruses in field samples.

60 APPLIED LIFE SCIENCES↗

Crystal structure and non-stoichiometry of cerium brannerite: Ce{sub 0.975}Ti{sub 2}O{sub 5.95}

The crystal structure of cerium brannerite, Ce{sub 0.975}Ti{sub 2}O{sub 5.95}, was determined from Rietveld analysis of high resolution neutron powder diffraction data (space group C2/m, a=9.8320(1) A, b=3.75287(6) A, c=6.8852(1) A, {beta}=119.230(1) Degree-Sign ). The presence of both cerium and oxygen vacancies was confirmed from Rietveld analysis and defect energy calculations, combined with careful investigation of the phase diagram. Formation of oxygen vacancies at the O1 site, charge compensated by Ce vacancies, relieves considerable Coulombic repulsion and hence structural strain associated with short O1-O1 contacts forming the shared edge of neighbouring TiO{sub 6} polyhedra. Consideration of the bond valence sum of Ce{sup 4+} in Ce{sub 0.975}Ti{sub 2}O{sub 5.95} afforded a revised value of the r{sub 0}=2.098{+-}0.039 A for the reference bond length, based on analysis of 21 crystal structures mined from the ICSD. - Graphical abstract: Neutron diffraction and atomistic defect energy calculations reveal the mechanism of nonstochiometry in cerium brannerite, Ce{sub 0.975}Ti{sub 2}O{sub 5.95}. Highlights: Black-Right-Pointing-Pointer The defect brannerite Ce{sub 0.975}Ti{sub 2}O{sub 5.95} was prepared by solid state synthesis. Black-Right-Pointing-Pointer Neutron diffraction confirmed the presence of Ce vacancies charge compensated by O vacancies. Black-Right-Pointing-Pointer Defect energy calculations show oxygen vacancies relieve structural strain associated with short O-O contact distances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray diffraction characterization of magnetostriction in Terfenol-D

The magnetostrictive response of a Terfenol-D pellet was measured via a laboratory-based X-ray diffractometer. X-ray diffraction patterns were collected from the pellet sample with and without the presence of an applied magnetic field (~30 mT) generated by placing a large magnet under the pellet. A standard reference material, Silicon 640c, was employed as an internal standard. Magnetostriction values of 323 and 227 ppm Δl/l were determined for the (104) and (110) indexed peaks, respectively, assuming a rhombohedral structure for Terfenol-D. A threshold noise level value of ~20 to 30 ppm Δl/l was suggested based on before/after measurements in the absence of the applied field. No clear evidence of domain wall rotation was detected via changes in relative intensities of diffraction peaks in the presence of the applied magnetic field.

Magnetostriction↗

Macroscale and Nanoscale Photoelectrochemical Behavior of p-Type Si(111) Covered by a Single Layer of Graphene or Hexagonal Boron Nitride

Two-dimensional (2D) materials may enable a general approach to the introduction of a dipole at a semiconductor surface as well as control over other properties of the double layer at a semiconductor/liquid interface. Vastly different properties can be found in the 2D materials currently studied due in part to the range of the distribution of density-of-states. In this work, the open-circuit voltage (V oc ) of p-Si–H, p-Si/Gr (graphene), and p-Si/h-BN (hexagonal boron nitride) in contact with a series of one-electron outer-sphere redox couples was investigated by macroscale measurements as well as by scanning electrochemical cell microscopy (SECCM). The band gaps of Gr and h-BN (0–5.97 eV) encompass the wide range of band gaps for 2D materials, so these interfaces (p-Si/Gr and p-Si/h-BN) serve as useful references to understand the behavior of 2D materials more generally. The value of Voc shifted with respect to the effective potential of the contacting solution, with slopes (ΔV oc /ΔE Eff ) of -0.27 and -0.38 for p-Si/Gr and p-Si/h-BN, respectively, indicating that band bending at the p-Si/h-BN and p-Si/Gr interfaces responds at least partially to changes in the electrochemical potential of the contacting liquid electrolyte. Additionally, SECCM is shown to be an effective method to interrogate the nanoscale photoelectrochemical behavior of an interface, showing little spatial variance over scales exceeding the grain size of the CVD-grown 2D materials in this work. The measurements demonstrated that the polycrystalline nature of the 2D materials had little effect on the results and confirmed that the macroscale measurements reflected the junction behavior at the nanoscale.

2D material↗

Contact value relations and density functional theory for the electrical double layer

The recently developed contact-corrected density functional theory is applied to an electric double layer containing a valence and size symmetric electrolyte. The restricted primitive model is used to describe the electrolyte, and a non-polarisable, smooth, planar, uniformly charged hard surface is used to model the electrode. Comparison with Monte Carlo simulation results for this system shows that the theory satisfies the first contact value relation in line with the premise of the approach. Additionally, the theory is found to satisfy the semi-empirical second contact value relation quite closely. This is a welcome result, since no reference is made to this second relation nor is the relation used in the theoretical development. The second contact relation is closely related to the anomalous positive temperature derivative of the double layer capacitance at low temperature, low ion concentration, and low electrode charge, and indeed, the contact-corrected density functional theory predicts this effect.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

COMPOSITION OF THE SOLAR CORONA, SOLAR WIND, AND SOLAR ENERGETIC PARTICLES

Along with temperature and density, the elemental abundance is a basic parameter required by astronomers to understand and model any physical system. The abundances of the solar corona are known to differ from those of the solar photosphere via a mechanism related to the first ionization potential of the element, but the normalization of these values with respect to hydrogen is challenging. Here, we show that the values used by solar physicists for over a decade and currently referred to as the 'coronal abundances' do not agree with the data themselves. As a result, recent analysis and interpretation of solar data involving coronal abundances may need to be revised. We use observations from coronal spectroscopy, the solar wind, and solar energetic particles as well as the latest abundances of the solar photosphere to establish a new set of abundances that reflect our current understanding of the coronal plasma.

79 ASTRONOMY AND ASTROPHYSICS↗

A long-lasting quiescence phase of the eruptive variable V1118 ORI

V1118 Ori is an eruptive variable belonging to the EXor class of pre-main-sequence stars whose episodic outbursts are attributed to disk accretion events. Since 2006, V1118 Ori has been in the longest quiescence stage ever observed between two subsequent outbursts in its recent history. We present near-infrared photometry of V1118 Ori carried out over the last eight years, along with complete spectroscopic coverage from 0.35 to 2.5 μm. Long term sampling of V1118 Ori in quiescence has never been performed, and hence we can benefit from the current circumstance by determining the lowest values (i.e., the zeroes) of the parameters to be used as reference for evaluating the physical changes typical of more active phases. A quiescence mass accretion rate of 1–3 × 10{sup −9} M yr{sup −1} can be derived and the difference from previous determinations is discussed. Based on line emission and IR color analysis, a visual extinction of 1–2 mag is consistently derived, confirming that V1118 Ori (at least in quiescence) is a low-extinction T Tauri star with a bolometric luminosity of about 2.1 L. An anti-correlation exists between the equivalent width of the emission lines and the underlying continuum. We searched the literature to evaluate whether or not such behavior is a common feature for the whole class. The anti-correlation is clearly recognizable for all of the available EXors in the optical range (Hβ and Hα lines); however, this is not as evident in the infrared (Paβ and Brγ lines). The observed anti-correlation supports the accretion-driven mechanism as the most likely to account for continuum variations.

79 ASTRONOMY AND ASTROPHYSICS↗

Representations of relativistic particles of arbitrary spin in Poincaré, Lorentz, and Euclidean covariant formulations of relativistic quantum mechanics

Background: Relativistic treatments of quantum mechanical systems are important for understanding hadronic structure and dynamics at subnucleon scales. Relativistic invariance of a quantum system means that there is an underlying unitary representation of the Poincaré group. This is equivalent to the requirement that the quantum observables (probabilities, expectation values, and ensemble averages) for equivalent measurements performed in different inertial reference frames are identical. Different representations are used in practice, including Poincaré covariant forms of dynamics, representations based on Lorentz covariant wave functions, Euclidean covariant representations, and representations generated by Lorentz covariant fields. Purpose: The purpose of this work is to illustrate the relation between the different equivalent representations of states in relativistic quantum mechanics. Method: The starting point is a description of a particle of mass m and spin j using irreducible representations of the Poincaré group. Since any unitary representation of the Poincaré group can be decomposed into a direct integral of irreducible representations, these are the basic building blocks of any relativistically invariant quantum theory. The equivalence is established by constructing equivalent Lorentz covariant irreducible representations from Poincaré covariant irreducible representations and constructing equivalent Euclidean covariant irreducible representations from Lorentz covariant irreducible representations. Results: Equivalent descriptions for positive mass representations of arbitrary spin are presented in each of these frameworks. Dynamical realizations of the different representations are briefly discussed. Conclusion: Poincaré covariant, Lorentz covariant, and Euclidean covariant realizations of relativistic dynamics are shown to be equivalent by explicitly relating the positive-mass positive-energy irreducible representations of the Poincaré group that appear in the direct integral.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ionization-induced thermally activated defect-annealing process in SiC

Ionizing events can lead to panoply of irradiation effects, and in silicon carbide (SiC), they drastically modify the defect production rate or the initial density. To better comprehend this phenomenon, 6H-SiC single crystals were first predamaged using low-velocity 100-keV Fe + ions at three fluences in the range of 10 14 cm -2 to induce three different initial disorder levels peaking at values between ~0.8 and 1 (1 corresponding to full amorphization). Crystals were then submitted to swift heavy ion irradiation in the 10 13 cm -2 fluence range at both low (~100 K) and high (~770 K) temperature. Rutherford backscattering spectrometry in channeling conditions revealed that swift ions allow annealing part of the initial damage, the recovery efficiency increasing with the irradiation temperature and reaching 75% in initially severely disordered crystals. This temperature effect has been qualitatively predicted by molecular dynamics simulations. Transmission electron microscopy allowed imaging both the recovery and the difference in the microstructure of the layers irradiated at low or high temperature. Recovery cross sections are discovered to lie in the range of a few square nanometers, consistent with previously reported values. A scenario for a general, two-step annealing mechanism referred to as an ionization-activated, thermally assisted defect-annealing (IATADA) process is proposed. This mechanism rationalizes the diverse descriptions reported so far in the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗