Temporal Convolutional Network Using Empirical Mode Decomposition to Detect Faults in Grid Connected Systems

Grid-connected power electronic systems require timely and reliable fault detection to prevent equipment damage and reduce downtime. This paper presents a forecasting-based anomaly detection pipeline that decomposes voltage and current measurements into intrinsic mode functions (IMFs) using empirical mode decomposition (EMD), then trains a causal temporal convolutional network (TCN) on normal-operation IMF data to predict short-horizon future dynamics. Deviations between forecasts and observations are summarized as reliability-weighted residual scores and thresholded per sensor using robust statistics with temporal persistence constraints to suppress false positives. To reduce runtime, EMD is performed on downsampled signals for detection, while raw-rate EMD is applied only within a short region of interest for high-frequency interpretability near detected events. Results on a simulated grid-connected converter system demonstrate that IMF-domain forecasting improves anomaly separability relative to raw-signal forecasting and provides interpretable evidence of faults across decomposition channels.

Sutton, Elizabeth [ORNL] (ORCID:0009000078885935)↗

Autonomous Wireless Technology Detection in Seamless IoT Applications

The ever-increasing use of Internet of Things (IoT) devices results in the implementation of multiple wireless technologies that would not only cater their data rate requirements but also support various applications. To optimize the energy efficiency and security of the wireless transmission, it is imperative to identify the wireless technologies in various IoT implementations. Many of the existing approaches are based on measuring only the receiving signal strength indicator (RSSI). However, such approaches may not work well because of transmit power control and complex channel variations among different wireless technologies. In this article, we propose an autonomous wireless detection scheme that considers multiple distinguishable physical (PHY)-layer settings for real-time identification of wireless technologies for real-time applications. Specifically, the proposed scheme relies on the PHY-layer measurements of the targeted spectrum. Transmission settings, such as bandwidth, carrier frequency, and RSSI are estimated from the raw in-phase and quadrature-phase (I/Q) measurements. In addition, a symbol-level extraction scheme is implemented to extract unique features of modulation settings. These aforementioned features are applied to a machine learning process to identify the received wireless technologies. Compared with raw I/Q measurements, the extracted features are much simplified and, thus, the machine learning classifier can be designed with a simple structure for fast processing on IoT nodes. Finally, the proposed schemes are primarily evaluated theoretically, followed by implementing them on a USRP software-defined radio (SDR)-based hardware testbed. The evaluation results demonstrate high accuracy in the real-time detection of different wireless technologies for seamless IoT applications.

42 ENGINEERING↗

GPU-based Image Compression for Efficient Compositing in Distributed Rendering Applications

Visualizations of large-scale data sets are often created on graphics clusters that distribute the rendering task amongst many processes. When using real-time GPU-based graphics algorithms, the most time-consuming aspect of distributed rendering is typically the com-positing phase - combining all partial images from each rendering process into the final visualization. Compo siting requires image data to be copied off the GPU and sent over a network to other processes. While compression has been utilized in existing distributed rendering compositors to reduce the data being sent over the network, this compression tends to occur after the raw images are transferred from the GPU to main memory. In this paper, we present work that leverages OpenGL / CUDA interoperability to compress raw images on the GPU prior to transferring the data to main memory. This approach can significantly reduce the device-to-host data transfer time, thus enabling more efficient compositing of images generated by distributed rendering applications.

Lipinksi, Riley↗

Data-driven predictive probability density function control of fiber length stochastic distribution shaping in refining process

Pulp is the most important raw material in paper in paper industries, whose Fiber Length Stochastic Distribution (FLSD) shaping directly determines the energy consumption and paper quality of the subsequent papermaking processes. However, the mean and variance are insufficient to describe the output FLSD shaping, which display non-Gaussian distribution properties. Therefore, the traditional control, method based on the mean and variance of fiber length is difficult to control the FLSD shaping effectively. In this paper, a novel data-driven predictive probability density function (PDF) control method is proposed for output FLSD shaping in refining process. Primarily, in order to improve the approximation accuracy of the PDF employing RBF neural network, the parameters (center value and width) of each RBF basis functions are tuned via utilizing iterative learning control (ILC) law, and the corresponding estimations of weights law can be obtained. Secondly, considering that the conventional linear model of weights vector has drawbacks of low accuracy and weak generalization ability, random vector functional link networks (RVFLNs) based data driven nonlinear modelling method is employed to characterize the prediction model between the input variables and weights vector. Finally, in order to reduce the randomness of the output FLSD, a minimum entropy control method under mean constraint is employed to design the predictive PDF controller for the output FLSD shaping with the help of the established nonlinear stochastic distribution model. Both simulations and experiments are given to illustrate the effectiveness and practicability of the proposed method.

Probability debsity function, Fiber length distrib↗

Normalized Solar-Induced Fluorescence Responds Earlier Than Vegetation Indices to the 2019 North China Plain Drought

Recently, solar-induced chlorophyll fluorescence (SIF) from satellites has shown potential for evaluating vegetation status and stress responses. Fluorescence quantum yield ($Φ_F$) is essentially linked to vegetation stress. However, the complex physiological and structural responses of SIF and $Φ_F$ to drought need further study. This study normalized SIF as SIFn to account for angular variations and fluctuations in photosynthetically active radiation (PAR), aiming for more accurate drought monitoring. SIFn anomalies were compared to historical baselines (2019–2021 averages) of vegetation indices (VIs), raw SIF, and $Φ_F$ during a 2019 drought in the North China Plain (NCP). Here, the results show SIFn provides an effective method for drought monitoring, showing the earliest decline compared to raw SIF, VIs, and $Φ_F$. In the first two weeks of drought, SIFn decreased by 8.2%, 7.0%, 12.5%, and 8.2% across the four NCP subdivisions. SIFn outperformed other indicators, proving sensitive to early drought detection. SIFn was also examined for tracking drought alleviation by rainfall. The uncertainty under different viewing geometries was quantified. SIFn anomalies showed a strong correlation with rainfall anomalies (R: 0.45 ~ 0.52) and meteorological factors like PAR (R: 0.80 ~ 0.84) and relative humidity (R:0.52 ~ 0.54). The correlation of near-infrared reflectance (NIRv) and $Φ_F$ anomalies with SIF was weak during drought onset (R: 0.16 ~ 0.32) but strong at the end (R: 0.83 ~ 0.87). These suggest both canopy structure (mainly characterized by NIRv) and vegetation chlorophyll ($Φ_F$) are impacted by drought and influence SIF at different stages.

54 ENVIRONMENTAL SCIENCES↗

A Method to Estimate the Atomic Number and Mass Thickness of Intervening Materials in Uranium and Plutonium Gamma-Ray Spectroscopy Measurements

To accurately characterize shielded special nuclear materials (SNM) using passive gamma-ray spectroscopy measurement techniques, the effective atomic number and the thickness of shielding materials must be measured. Intervening materials between the source and detector may affect the estimated source isotopics (uranium enrichment and plutonium grade) for techniques which rely on raw count rates or photopeak ratios of gamma-ray lines separated in energy. Furthermore, knowledge of the surrounding materials can provide insight regarding the configuration of a device containing SNM. The described method was developed using spectra recorded using high energy resolution CdZnTe detectors, but can be expanded to any gamma-ray spectrometers with energy resolution of better than 1% FWHM at 662 keV. The effective atomic number, Z, and mass thickness of the intervening shielding material are identified by comparing the relative attenuation of different gamma-ray lines and estimating the proportion of Compton scattering interactions to photoelectric absorptions within the shield. While characteristic Kα x-rays can be used to identify shielding materials made of high Z elements, this method can be applied to all shielding materials. This algorithm has adequately estimated the effective atomic number for shields made of iron, aluminum, and polyethylene surrounding uranium samples using experimental data. The mass thicknesses of shielding materials have been estimated with a standard error of less than 1.3 g/cm2 for iron shields up to 2.5 cm thick. The effective atomic number was accurately estimated to 26 ± 5 for all iron thicknesses.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Probabilistic Solar Power Forecasting Using Bayesian Model Averaging

There is rising interest in probabilistic forecasting to mitigate risks from solar power uncertainty, but the numerical weather prediction (NWP) ensembles readily available to system operators are often biased and underdispersed. We propose a Bayesian model averaging (BMA) post-processing method suitable for forecasting power from utility-scale photovoltaic (PV) plants at multiple time horizons up to at least the day-ahead timescale. BMA is a kernel dressing technique for NWP ensembles in which the forecast is a weighted sum of member-specific probability density functions. We tailor BMA for utility-scale PV forecasting by modeling power clipping at the AC inverter rating and advance the theory of BMA with a new beta kernel parameterization that accommodates theoretical constraints not previously addressed. BMA is demonstrated for a case study of 11 utility-scale PV plants in Texas, forecasting at hourly resolution for the complete year 2018. BMA's mixture-model approach mitigates underdispersion of the raw ensemble to significantly improve forecast calibration, while consistently outperforming an ensemble model output statistics (EMOS) parametric approach from the literature. At 4-hour lead time, the BMA post-processing achieves continuous ranked probability skill scores of 2--36% over the raw ensemble, with consistent performance at multiple lead times suitable for power system operations.

14 SOLAR ENERGY↗

SIMS Data Correction Procedure for Quasi‐Simultaneous Arrival ( QSA ) Under‐counting and Ramifications of Misapplication

Isotope geochemistry requires isotope ratios measured using secondary ion mass spectrometry (SIMS) to be made with optimal precision and accuracy. Under some analytical conditions when using electron multiplier detectors, secondary ions may be under‐counted because of quasi‐simultaneous arrival (QSA) at the first dynode. The relative magnitude of the associated QSA correction to raw measured isotopic ratios can be up to seventy permil or more. Therefore, not applying the correction, or misapplication of it could lead to significant inaccuracies in published isotope ratio data. Examples and ramifications of the latter are described in addition to a straightforward procedure for QSA under‐counting correction.

Geochemistry & Geophysics↗

Effects of particle size and briquetting of soda-lime-silicate glass batch on viscosity during batch-to-melt conversion

To assess the effects of grain size and briquetting on glass-batch melting, we measured the viscosity (?b) of an industrial glass batch during its conversion to molten simulated architectural glass within the temperature interval of 1050 °C to 1300 °C and at a shear rate of 0.02 s-1. On the basis of the mass fraction of undissolved sand (xs), which was determined using X-ray diffraction analysis on quenched batch samples, and the gas-phase fraction (p), which was obtained from volumetric measurements, we established the relationship ln(?b/?m) = a0 + bsxs + app, where ?m is the transition melt viscosity, a0 is the melt homogeneity coefficient, bs is the coefficient for undissolved sand, and ap is the coefficient for bubbles. The obtained values, bs = 8.756 and ap = 0.658, indicate that undissolved silica sand strongly influences batch viscosity. Consequently, compared with coarse-grained batches, fine raw materials and briquetting resulted in lower batch viscosity during conversion. Owing to their lower viscosities and higher heat conductivities, batches from finer raw materials or batches shaped into briquettes are expected to enhance the melting rate of batch blankets in industrial glass-melting furnaces.

Doi, Yoji↗

Hydrogen evolution promotion of Au‐nanoparticles‐decorated TiO 2 nanotube arrays prepared by dip‐loading approach

Abstract Au nanoparticle (NPs)@TiO 2 nanotube arrays (NTAs) heterostructured films with enhanced H 2 generation rate under full spectrum were synthesized, by using a controllable and facile dip‐loading approach. Size of the Au NPs was well‐distributed around 7 nm, and the TiO 2 NTAs were found vertically aligned. Due to LSPR effect and Schottky contact, the as‐prepared Au NPs@TiO 2 NTAs heterostructured films exhibited improved H 2 generation abilities as well as photocatalytic degradation abilities. H 2 evolution rate of the obtained samples (effective area: 5.25 cm 2 ) reached 74.56 μmol/h, which was 38 times higher than that of the raw TiO 2 NTAs. And the Au NPs@TiO 2 NTAs samples also showed an obvious advantage over the raw TiO 2 NTAs, in methyl orange degradation under UV illumination. Repetition experiments were further carried out to ensure the dip‐loading method was a reliable fabrication process, and the amount of Au particles attached on TiO 2 tube walls could be manipulated by changing the dip‐loading cycle times.

Zhang, Dainan↗

Regional analysis of aluminum and steel flows into the American automotive industry

Aluminum and steel represent the two most dominant metals in light duty vehicles, yet the flows of these materials into the American automotive industry have not been well characterized. This study proposes and implements a method for analyzing the flow of these metals into the automotive industry. We create a framework for performing regionally linked, sector specific material flow analyses and use this framework to trace flows of aluminum and steel entering the American automotive industry, focusing on flows downstream from raw material production. We show that automotive aluminum sheet and extrusions are sourced primarily from the NPCC (23%), SERC (20%), MRO (18%), and RFC (13%) NERC regions and a spatially unresolved Local region within the U.S. and Canada (18%). We determine that primary aluminum is largely from Canada (70%), nearly all from Quebec (69%). Further upstream, alumina and bauxite originate mostly from Brazil, Australia, and Jamaica. We also show that finished automotive steel is sourced primarily from the RFC (63%) and SERC (20%) regions. The crude steel supply similarly originates mainly from the RFC (69%) and SERC (7%) regions. Upstream raw materials including coke, coking coal, iron ore, lime, and steel scrap are primarily sourced from the U.S. with only direct reduced iron and pig iron used in electric arc furnace steel production coming mostly from outside the U.S. The framework developed here allows for increased spatial resolution of material flows, which can be used to develop more specific life cycle impact factors for life cycle assessments.

aluminum↗

Capacity mapping for optimum utilization of pulverizers for coal fired boilers - article no. 032201

Capacity mapping is a process of comparison of standard inputs with actual fired inputs to assess the available standard output capacity of a pulverizer. The base capacity is a function of grindability; fineness requirement may vary depending on the volatile matter (VM) content of the coal and the input coal size. The quantity and the inlet will change depending on the quality of raw coal and output requirement. It should be sufficient to dry pulverized coal (PC). Drying capacity is also limited by utmost PA fan power to supply air. The PA temperature is limited by air preheater (APH) inlet flue gas temperature; an increase in this will result in efficiency loss of the boiler. The higher PA inlet temperature can be attained through the economizer gas bypass, the steam coiled APH, and the partial flue gas recirculation. The PS/coal ratioincreases with a decrease in grindability or pulverizer output and decreases with a decrease in VM. The flammability of mixture has to be monitored on explosion limit. Through calibration, the PA flow and efficiency of conveyance can be verified. The velocities of coal/air mixture to prevent fallout or to avoid erosion in the coal carrier pipe are dependent on the PC particle size distribution. Metal loss of grinding elements inversely depends on the YGP index of coal. Variations of dynamic loading and wearing of grinding elements affect the available milling capacity and percentage rejects. Therefore, capacity mapping in necessary to ensure the available pulverizer capacity to avoid overcapacity or undercapacity running of the pulverizing system, optimizing auxiliary power consumption. This will provide a guideline on the distribution of raw coal feeding in different pulverizers of a boiler to maximize system efficiency and control, resulting in a more cost effective heat rate.

01 COAL, LIGNITE, AND PEAT↗

Local-Scale Simulations of Nucleate Boiling on Micrometer Featured Surfaces: Preprint

A high-fidelity computational fluid dynamics (CFD)-based model for bubble nucleation of the refrigerant HFE7100 on micrometer-featured surfaces is presented in this work. The single-fluid incompressible Navier-Stokes equations, along with energy transport and natural convection effects are solved on a featured surface resolved grid. An a priori cavity detection method is employed to convert raw profilometer data of a surface into well-defined cavities. The cavity information and surface morphology are represented in the CFD model by geometric mesh deformations. Surface morphology is observed to initiate buoyancy-driven convection in the liquid phase, which in turn results in faster nucleation of cavities. Simulations pertaining to a generic rough surface show a trend where smaller size cavities nucleate with higher wall superheat. This local-scale model will serve as a self-consistent connection to larger device scale continuum models where local feature representation is not possible.

97 MATHEMATICS AND COMPUTING↗

Phantom study to evaluate contrast-medium-enhanced digital subtraction mammography with a full-field indirect-detection system

This phantom study simulates contrast-medium-enhanced digital subtraction mammography (CEDM) and compares subtracted image quality and total mean glandular dose for two alternative spectral combinations available in a GE Senographe DS mammography unit. The first choice takes advantage of large iodine attenuation at low photon energies and uses traditionally available spectra (anode/filter combinations Mo/Mo at 25 kV and Rh/Rh at 40 kV, ''Mo25-Rh40''). The second choice, selected from a previous analytical optimization, includes harder spectra obtained by adding external filtration to traditional beams (Rh/Rh at 34 kV and Rh/Rh+5 mm of Al at 45 kV, ''Rh34-Rh45H''). Individual images of a custom-made phantom containing tubes of various diameters filled with water- or iodine-based contrast agent were acquired with both spectral combinations. The total breast entrance air kerma, considering subtraction of two images, was limited to 8.76 mGy (1 R). The results were compared to predictions obtained through an analytical formalism that assumes noise of stochastic origin. Individual images were evaluated and subtracted under five combinations of temporal and dual-energy modalities. Signal variance analysis in individual raw images showed important contributions of nonstochastic origin, associated with the software applied to raw images, the curved geometry, and strong attenuation of the phantom cylindrical iodine-filled tubes, causing experimental SNR to vary from 2.2 to 0.8 times the predictions from low to high values of SNR. Iodine contrast in the subtracted images was found to be mainly defined by the spectra, independent of exposure, and linearly dependent on the iodine mass thickness. The highest contrast was obtained with the combined dual-energy temporal subtraction with Rh34-Rh45H, its value was 7% larger than the highest value measured with Mo25-Rh40. As expected, temporal modalities (single and dual energy, any spectral choice) led to higher contrast-over-noise ratio (CNR) than nontemporal dual-energy subtraction, the latter being negligibly small with Mo25-Rh40. CNR for 4 mg iodine/cm{sup 2} imaged temporally in a dual-energy fashion with Rh34-Rh45H (iodine imaged at high energy) is about 1.7 times the optimum for Mo25-Rh40 (iodine imaged at low energy). Iodine thicknesses needed to fulfill Rose's criterion were 0.78{+-}0.02 mg iodine/cm{sup 2} for Mo25-Rh40 and 0.54{+-}0.17 mg iodine/cm{sup 2} for Rh34-Rh45H, both lower than the proposed biological concentration of iodine in breast tumors after contrast medium administration. Although similar dose levels were obtained with both spectral choices under dual-energy (temporal and nontemporal) subtraction, the dose obtained in single-energy temporal subtraction with the Mo25 spectrum was 1.2 mGy lower than the dose from the modality offering the highest CNR. In all results considered, the spectral choice Mo25-Rh40 was found to represent an interesting alternative to the use of high-energy hardened spectra for CEDM, particularly when performing dynamic studies of the contrast-agent uptake in breast lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images

Purpose: Applications of cone-beam CT (CBCT) to image-guided radiation therapy (IGRT) are hampered by shading artifacts in the reconstructed images. These artifacts are mainly due to scatter contamination in the projections but also can result from uncorrected beam hardening effects as well as nonlinearities in responses of the amorphous silicon flat panel detectors. While currently, CBCT is mainly used to provide patient geometry information for treatment setup, more demanding applications requiring high-quality CBCT images are under investigation. To tackle these challenges, many CBCT correction algorithms have been proposed; yet, a standard approach still remains unclear. In this work, we propose a shading correction method for CBCT that addresses artifacts from low-frequency projection errors. The method is consistent with the current workflow of radiation therapy. Methods: With much smaller inherent scatter signals and more accurate detectors, diagnostic multidetector CT (MDCT) provides high quality CT images that are routinely used for radiation treatment planning. Using the MDCT image as ''free'' prior information, we first estimate the primary projections in the CBCT scan via forward projection of the spatially registered MDCT data. Since most of the CBCT shading artifacts stem from low-frequency errors in the projections such as scatter, these errors can be accurately estimated by low-pass filtering the difference between the estimated and raw CBCT projections. The error estimates are then subtracted from the raw CBCT projections. Our method is distinct from other published correction methods that use the MDCT image as a prior because it is projection-based and uses limited patient anatomical information from the MDCT image. The merit of CBCT-based treatment monitoring is therefore retained. Results: The proposed method is evaluated using two phantom studies on tabletop systems. On the Catphan(c)600 phantom, our approach reduces the reconstruction error from 348 Hounsfield unit (HU) without correction to 4 HU around the object center after correction, and from 375 HU to 17 HU in the high-contrast regions. In the selected regions of interest (ROIs), the average image contrast is increased by a factor of 3.3. When noise suppression is implemented, the proposed correction substantially improves the contrast-to-noise ratio (CNR) and therefore the visibility of low-contrast objects, as seen in a more challenging pelvis phantom study. Besides a significant improvement in image uniformity, a low-contrast object of {approx}25 HU, which is otherwise buried in the shading artifacts, can be clearly identified after the proposed correction due to a CNR increase of 3.1. Compared to a kernel-based scatter correction method coupled with an analytical beam hardening correction, our approach also shows an overall improved performance with some residual artifacts. Conclusions: By providing effective shading correction, our approach has the potential to improve the accuracy of more advanced CBCT-based clinical applications for IGRT, such as tumor delineation and dose calculation.

60 APPLIED LIFE SCIENCES↗

Comparative performance of multiview stereoscopic and mammographic display modalities for breast lesion detection

Purpose: Mammography is known to be one of the most difficult radiographic exams to interpret. Mammography has important limitations, including the superposition of normal tissue that can obscure a mass, chance alignment of normal tissue to mimic a true lesion and the inability to derive volumetric information. It has been shown that stereomammography can overcome these deficiencies by showing that layers of normal tissue lay at different depths. If standard stereomammography (i.e., a single stereoscopic pair consisting of two projection images) can significantly improve lesion detection, how will multiview stereoscopy (MVS), where many projection images are used, compare to mammography? The aim of this study was to assess the relative performance of MVS compared to mammography for breast mass detection. Methods: The MVS image sets consisted of the 25 raw projection images acquired over an arc of approximately 45 deg. using a Siemens prototype breast tomosynthesis system. The mammograms were acquired using a commercial Siemens FFDM system. The raw data were taken from both of these systems for 27 cases and realistic simulated mass lesions were added to duplicates of the 27 images at the same local contrast. The images with lesions (27 mammography and 27 MVS) and the images without lesions (27 mammography and 27 MVS) were then postprocessed to provide comparable and representative image appearance across the two modalities. All 108 image sets were shown to five full-time breast imaging radiologists in random order on a state-of-the-art stereoscopic display. The observers were asked to give a confidence rating for each image (0 for lesion definitely not present, 100 for lesion definitely present). The ratings were then compiled and processed using ROC and variance analysis. Results: The mean AUC for the five observers was 0.614{+-}0.055 for mammography and 0.778{+-}0.052 for multiview stereoscopy. The difference of 0.164{+-}0.065 was statistically significant with a p-value of 0.0148. Conclusions: The differences in the AUCs and the p-value suggest that multiview stereoscopy has a statistically significant advantage over mammography in the detection of simulated breast masses. This highlights the dominance of anatomical noise compared to quantum noise for breast mass detection. It also shows that significant lesion detection can be achieved with MVS without any of the artifacts associated with tomosynthesis.

60 APPLIED LIFE SCIENCES↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual trial framework for quantifying the detectability of masses in breast tomosynthesis projection data

Purpose: Digital breast tomosynthesis (DBT) is a promising breast cancer screening tool that has already begun making inroads into clinical practice. However, there is ongoing debate over how to quantitatively evaluate and optimize these systems, because different definitions of image quality can lead to different optimal design strategies. Powerful and accurate tools are desired to extend our understanding of DBT system optimization and validate published design principles. Methods: The authors developed a virtual trial framework for task-specific DBT assessment that uses digital phantoms, open-source x-ray transport codes, and a projection-space, spatial-domain observer model for quantitative system evaluation. The authors considered evaluation of reconstruction algorithms as a separate problem and focused on the information content in the raw, unfiltered projection images. Specifically, the authors investigated the effects of scan angle and number of angular projections on detectability of a small (3 mm diameter) signal embedded in randomly-varying anatomical backgrounds. Detectability was measured by the area under the receiver-operating characteristic curve (AUC). Experiments were repeated for three test cases where the detectability-limiting factor was anatomical variability, quantum noise, or electronic noise. The authors also juxtaposed the virtual trial framework with other published studies to illustrate its advantages and disadvantages. Results: The large number of variables in a virtual DBT study make it difficult to directly compare different authors' results, so each result must be interpreted within the context of the specific virtual trial framework. The following results apply to 25% density phantoms with 5.15 cm compressed thickness and 500 {mu}m{sup 3} voxels (larger 500 {mu}m{sup 2} detector pixels were used to avoid voxel-edge artifacts): 1. For raw, unfiltered projection images in the anatomical-variability-limited regime, AUC appeared to remain constant or increase slightly with scan angle. 2. In the same regime, when the authors fixed the scan angle, AUC increased asymptotically with the number of projections. The threshold number of projections for asymptotic AUC performance depended on the scan angle. In the quantum- and electronic-noise dominant regimes, AUC behaviors as a function of scan angle and number of projections sometimes differed from the anatomy-limited regime. For example, with a fixed scan angle, AUC generally decreased with the number of projections in the electronic-noise dominant regime. These results are intended to demonstrate the capabilities of the virtual trial framework, not to be used as optimization rules for DBT. Conclusions: The authors have demonstrated a novel simulation framework and tools for evaluating DBT systems in an objective, task-specific manner. This framework facilitates further investigation of image quality tradeoffs in DBT.

60 APPLIED LIFE SCIENCES↗