Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Definitions for Testing Whether Evaluated Nuclear Data Relative Uncertainties are Realistic in Size

This document describes various tests that can be used to check whether evaluated relative uncertainties stored in nuclear-data covariances are realistic. To be more specific, these tests check whether nuclear-data uncertainties could be either over- or under-estimated given the input that usually enters the evaluation of nuclear-data mean values and covariances. Warning and error messages on the reliability of nuclear-data uncertainties will result from these tests. If uncertainties of one specific nuclear-data observable trigger warning messages from multiple tests, an evaluator should counter-check the reliability of the relative uncertainties of this particular nuclear-data covariance matrix.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Collaborative Research Towards a tonne-scale bolometer-based neutrinoless double beta decay experiment (Final Report)

Cryogenic bolometers are an excellent technology for neutrinoless double beta decay searches owing to their very high energy resolution and potential for high radiopurity. The current most advanced large-scale experiment using these detectors is the Cryogenic Underground Observatory for Rare Events (CUORE). The largest source of background in CUORE is degraded alpha particles, emitted from shallow depths of the detector holders, which can deposit a thermal energy signature similar to neutrinoless double beta decay. To mitigate this background, the CUPID concept (CUORE Upgrade with Particle IDentification) proposes to use scintillating cryogenic detectors. Detecting both the scintillation light and the thermal signal allows discrimination between alpha particle events and beta/gamma events. We report on the design and execution of R&D tests to optimize the design of the single detector module, in particular the scintillation light collection efficiency at cryogenic temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

HARD: A performance portable radiation hydrodynamics code based on FleCSI framework

Hydrodynamics And Radiation Diffusion (HARD) is an open-source application for high-performance simulations of compressible hydrodynamics with radiation-diffusion coupling. Built on the FleCSI (Bergen et al., 2021 [1]) (Flexible Computational Science Infrastructure) framework, HARD expresses its computational units as tasks whose execution can be orchestrated by multiple back-end runtimes, including Legion (Bauer et al., 2012 [2]), MPI (Forum, 1994 [3]), and HPX (Kaiser et al., 2020 [4]). Node-level parallelism is handled through Kokkos (Edwards et al., 2014 [5]), providing a single-source, portable code base that runs efficiently on laptops, small homogeneous clusters, and the largest heterogeneous supercomputers currently available. To ensure scientific reliability, HARD includes a regression test suite that automatically reproduces canonical verification problems such as the Sod and LeBlanc shock tubes, and the Sedov blast wave, comparing numerical solutions against known analytical results. The project is distributed under an OSI-approved license, hosted on GitHub, and accompanied by reproducible build scripts and continuous integration workflows. This combination of performance portability, verification infrastructure, and community-focused development makes HARD a sustainable platform for advancing radiation hydrodynamics research across multiple domains.

97 MATHEMATICS AND COMPUTING↗

Report on ISR-1 High-Altitude Balloon Flight

To test small technologies at lower cost for space science applications, LANL has developed a small high altitude balloon payload that could, in the future, be regularly and inexpensively launched from LANL. A neutron detector, NEMO, was integrated to evaluate its performance in a space-like mixed-radiation environment and collect neutron data in the atmosphere. In collaboration with EES-14, a high-altitude balloon payload was launched from LANL Technical Area 51 on February 27, 2023 and April 17, 2023. For real-time geolocation, a SAM-M8Q M8 GNSS module was used to get position and time, and an Iridium RockBLOCK 9603 was used to communicate with the ground using the Iridium satellite fleet. These modules were all controlled using an Iteaduino Mega microcontroller board. Finally, a High Altitude Science Eagle Flight Computer with a temperature pressure sensor ran independently, writing data to an SD card. All of these modules were powered by a 5 mAh lithium polymer battery. The battery was attached to the bottom of the payload while the remaining electronics were embedded in the underside of the top of the payload. These modules were wired as seen in Figure 1-2. The Iteaduino Mega microcontroller board was programmed to use the RockBLOCK to send a message once every 10 minutes containing neutron and GPS data read off the NEMO and SAM M8Q, respectively. Once the message send attempt finished, the RockBLOCK would be slept for the rest of the 10 minute interval. The Eagle Flight Computer ran continuously throughout the flight, taking data every 6 seconds. The RockBLOCK message data was set up to be delivered from the Iridium satellite fleet to a website, where it was stored and parsed to create live maps and plots for analysis and balloon retrieval. The RockBLOCK message data was additionally configured to be sent to an email as a fail-safe. The payload was ground-tested successfully for over 50 hours, with multiple revisions occurring to best prepare for conditions at altitude and improve the software and firmware to fix any issues that cropped up with the data pipeline. Additional to the balloon payload, the flight had an attached iMet-4 radiosonde and Garmin T5 GPS Dog Collar. The radiosonde provided GPS and meteorological data. The T5 dog collar is used along with a Garmin Astro 430 to track the balloon at a range of up to 9 miles for retrieval. The balloon itself was initially a 1600 g meteorological balloon with an attached High Altitude Science parachute, both of which can be seen in Figure 1-3. After the first flight, the EES team swapped to a Rocketman parachute.

42 ENGINEERING↗

Millicharged relics reveal massless dark photons

The detection of massless kinetically-mixed dark photons is notoriously difficult, as the effect of this mixing can be removed by a field redefinition in vacuum. In this work, we study the prospect of detecting massless dark photons in the presence of a cosmic relic directly charged under this dark electromagnetism. Such millicharged particles, in the form of dark matter or dark radiation, generate an effective dark photon mass that drives photon-to-dark photon oscillations in the early universe. We also study the prospect for such models to alleviate existing cosmological constraints on massive dark photons, enlarging the motivation for direct tests of this parameter space using precision terrestrial probes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics of the implosion up until the time of ignition in a revolver (triple-shell) capsule

Here, a revolver is designed to have two dynamical fuel implosion stages to reach ignition: a shock phase in which the fuel is pre-heated up until the shock collapses at the capsule center, followed by an adiabatic compression phase to ignition. This picture assumes ideal hydrodynamics. Employing the state-of-the-art, hybrid (kinetic-ion/fluid electron), multi-ion Vlasov-Fokker-Planck code, iFP, along with semi-analytic predictions from ideal hydrodynamics in spherical geometry, we confirm this two phase picture—resolving some outstanding questions in Revolver design along the way. Although we find that shock kinetic effects and non-ideality are present in the course of the implosion, these effects do not change the overall dynamics (which is well described by ideal hydrodynamics theory). Additionally, we put the assumption of adiabaticity, for the post-collapse phase, to the test. Finally, we verify the ideal hydro-conjecture that the shock collapse (fuel) convergence is ~2.12 given a single shock, and we confirm that the convergence is about 2.5 in the case of two shocks—in agreement with previous radiation-hydrodynamics simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proof-of-concept of a neutron time-of-flight ellipsoidal detector

The time-resolved measurement of neutrons emitted from nuclear implosions at inertial confinement fusion facilities is used to characterize the fusing plasma. Several significant quantities are routinely measured by neutron time-of-flight (nToF) detectors in these experiments. Current nToF detectors use scintillators as well as solid-state Cherenkov radiators. The latter has an inherently faster time response and can provide a co-registered γ-ray measurement as well as improved precision in the bulk hot-spot velocity. This work discusses a nToF ellipsoidal detector that also utilizes a solid-state Cherenkov radiator. The detector has the potential to achieve a fast instrument response function allowing for characterization of the γ-ray burn history as well as the ability to field the detector closer to the fusion source. Proof-of-concept testing of the nToF ellipsoidal detector has been conducted at the National Ignition Facility using commercial optics. A time-resolved neutron signal has been measured from the diagnostic. Preliminary simulations corroborate the results.

Jeet, J. (ORCID:0000000291091563)↗

Setups for eliminating static charge of the ATLAS18 strip sensors

Abstract Construction of the new all-silicon Inner Tracker (ITk), developed by the ATLAS collaboration to beable to track charged particles produced at the High-Luminosity LHC, started in 2020 and is expected tocontinue till 2028. The ITk detector will include 18,000 highly segmented and radiation hard n+-in-psilicon strip sensors (ATLAS18), which are being manufactured by Hamamatsu Photonics. Mechanical and electrical characteristics of produced sensors are measured upon their delivery at several institutes participating in a complex Quality Control (QC) program. The QC tests performed on each individual sensor check the overall integrity and quality of the sensor.During the QC testing of ATLAS18 strip sensors, an increased number of sensors thatfailed the electrical tests was observed. In particular, IV measurements indicated an early breakdown,while large areas containing several tens or hundreds of neighbouring strips with low interstrip isolationwere identified by the Full strip tests, and leakage current instabilities were measured in a long-term leakage current stability setup. Moreover, a high surface electrostatic charge reaching a level of several hundreds of volts per inch was measured on a large number of sensors and on the plastic sheets, whichmechanically protect these sensors in their paper envelopes. Accumulated data indicates a clearcorrelation between observed electrical failures and the sensor charge-up.To mitigate the above-described issues, the QC testing sites significantly modified the sensor handlingprocedures and introduced sensor recovery techniques based on irradiation of the sensor surface with UVlight or application of intensive flows of ionized gas. In this presentation, we will describe the setupsimplemented by the QC testing sites to treat silicon strip sensors affected by static charge andevaluate the effectiveness of these setups in terms of improvement of the sensor performance.

Instruments & Instrumentation↗

Post Irradiation Examination of Pressurized Water Reactor Stainless Steel Internal Components

Internal structural components of pressurized water reactors (PWR), such as baffle former bolts, are subjected to significant neutron irradiation and mechanical stresses at elevated temperatures during plant operation. Over the long operation of the power plant, these conditions lead to potential degradation and reduced load-carrying capacity of these bolts. To understand property degradation more fully, to confirm the results of experimental irradiation programs, and to predict operational lifetime performance of structural materials in internal components, post irradiation examination of harvested materials from operating nuclear reactors is required. In this work, two high fluence 316 stainless steel baffle former bolts were retrieved from a commercial Westinghouse two-loop downflow type PWR and then sectioned for analysis via mechanical testing and microstructural characterization. The irradiation damage fluctuated along the bolt length with damage levels from 15 to 41 displacements per atom with the bolt head receiving approximately twice the neutron damage levels as that of the bolt thread section. Mechanical testing evaluations showed extensive irradiation hardening and a sharp decrease in fracture toughness in all parts of the bolt, though with limited variation along the bolt length. Microstructural characterization using analytical scanning transmission electron microscopy and atom probe tomography showed significant radiation induced precipitation, segregation, and dislocation loop and cavity formation. However, unlike the mechanical behavior, there was considerable variation along the bolt length but opposite of what may be expected, with more precipitation and cavity formation in the bolt thread where the neutron radiation dose is less than in the bolt head where the neutron radiation dose is higher. The cause of this variation is likely due to gradients in temperature, neutron energy spectra, and gamma irradiation.

Lach, Tim↗

Experimental Evaluation of Deformation and Fracture Mechanisms in Highly Irradiated Austenitic Steels

The present report documents recent experimental results of analysis using scanning electron microscopy/electron backscatter diffraction (SEM-EBSD) of plastic deformation mechanisms and strain localization phenomena in austenitic steels irradiated by neutrons. Experiments were performed with specimens irradiated to 125 dpa and, additionally, with specimens that experienced radiation-induced swelling up to 3%. Section 1 briefly analyzes the deformation localization in irradiated steels and its consequences on the material performance. The section describes the advantages and importance of the SEM-EBSD approach combined with in situ mechanical testing capability. Section 2 briefly introduces the experimental tools and methods (i.e., SEM/EBSD in situ tensile frame, electric discharge machine to manufacture irradiated specimens) and describes the investigated materials (i.e., element composition, irradiation conditions, and general microstructure). Section 3 describes the key experimental results and provides a brief analysis and comparison with the datasets obtained earlier within the same task (i.e., low-dose specimens). The discussion focuses on EBSD microstructure maps with strain localization features, misorientation evolution as a function of strain, and observed deformation mechanisms. Section 4 evaluates data collected in recent years on highly irradiated steel and estimates the possible misorientation evolution under irradiation. The section introduces and discusses the concept of in-service-induced damage as an irradiation-assisted stress-corrosion cracking precursor. Section 5 summarizes the work performed. As expected, the present work results are beneficial for exploring and understanding degradation mechanisms in highly irradiated in-core materials found in light water reactors after long-term in-service life.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavour violating conversion of negative muons into electrons in the coulomb field of an Al nucleus, planning to reach a single event sensitivity of about $3\cdot10^{−17}$, four orders of magnitude beyond the current best limit.The conversion electron has a clear monoenergetic signature at 104.967 MeV, slightly below the muon rest mass, and will be identified by a complementary measurement carried out by a high-resolution tracker and an electromagnetic calorimeter (EMC). The calorimeter is composed of 1348 pure CsI crystals, each read by two custom UV-extended SiPMs, that are arranged in two annular disks. The EMC should achieve better than 10% energy resolution and 500 ps timing resolution for 100 MeV electrons and maintain extremely high levels of reliability and stability and in a harsh operating environment with high vacuum, 1 T B-field and radiation exposures up to 100 krad and $10^{12} \rm{n}_\rm{1MeVeq}/\rm{cm}^{2}$.The calorimeter technological choice, along with the design of the custom front-end electronics, cooling and mechanical systems were validated through an electron beam test on a large-scale 51-crystals prototype (Module-0) and extensive test campaigns that characterised and verified the performance of crystals, photodetectors, analogue and digital electronics. This included hardware stress tests and irradiation campaigns with neutrons, protons, and photons.The production and QC phases of all calorimeter components is completed apart for the digital electronics that has been revised for improving its resilience to SEU and SEL. A series of vertical slice tests with the final electronics is being carried out on the Module-0 at LNF along with the implementation and validation of the calibration procedures. The first disk has been assembled in 2022 while the second disk is under assembly at the moment of writing. Status of construction will be summarised, along with plans for commissioning and first calibration of the fully assembled disks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sandia National Laboratories FY20 Progress Report

The Energetic Neutrons campaign led by Sandia National Laboratories (SNL) had a successful year testing electronic devices and printed circuit boards (PCBs) under 14 MeV neutron irradiation at OMEGA. During FY20 the Energetic Neutrons campaign increased the number and complexity of experiments, continued collaborations with external organizations, and generated knowledge that supports SNL’s National Security mission. In FY20 the Energetic Neutrons campaign was executed by an early career team led by a new PI. The SNL team members were trained to take over new responsibilities during the shot day to increase the number and complexity of experiments in the campaigns. Also, in FY20 for the first time the Energetic Neutrons campaign had a graduate student contributing with pre and post-irradiation characterizations at SNL of the semiconductor devices irradiated at OMEGA. In FY20 SNL collaborated with the Air Force Nuclear Weapons Center (AFNWC) and supported experiments related to radiation effects in semiconductor devices. SNL also gave the opportunity to ride along to Los Alamos National Laboratory and multiple scientists from MIT and LLE. SNL continued using the last two generations of the Neutron Effects Diagnostics (NEDs) to field active and passive experiments but also redesigned the latest generation of the NEDs to accommodate larger components and improve the vacuum sealing as shown in figure 1a. The redesigned NEDs allowed SNL to perform active tests of a high voltage (HV) PCB for the first time at OMEGA; where signals before, during and after the irradiation were recorded. The HV PCB installed in one of the SNL NEDs is shown in figure 1b where a 3D-printed nosecone was used to check for mechanical and electrical interference. Passive irradiations of multiple components were followed up with leakage current, gain measurements and radiation-induced defect characterization.

42 ENGINEERING↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

DRiFT - Release 1.0.0 Organic Scintillators

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that postprocesses output from the extensively validated radiation transport code, MCNP [1], and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. Although DRiFT development has included scintillator [2], gas [3], and semiconductor features [4], the focus of this release is on organic scintillator and associated capabilities. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts [5, 6]. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation-Induced Effects on the Extraction Properties of Hexa-n-octylnitrilo-triacetamide (HONTA) Complexes of Americium and Europium

The candidate An(III)/Ln(III) separation ligand hexa-n-octylnitrilo-triacetamide (HONTA) was irradiated under envisioned SELECT (Solvent Extraction from Liquid waste using Extractants of CHON-type for Transmutation) process conditions (n-dodecane/0.1 M HNO 3 ) using a solvent test loop in conjunction with cobalt-60 gamma irradiation. The extent of HONTA radiolysis and complimentary degradation product formation was quantified by HPLC-ESI-MS/MS. Further, the impact of HONTA radiolysis on process performance was evaluated by measuring the change in 243 Am and 154 Eu distribution ratios as a function of absorbed gamma dose. HONTA was found to decay exponentially with increasing dose, affording a dose coefficient of d = (4.48 ± 0.19) × 10 –3 kGy –1 . Multiple degradation products were detected by HPLC-ESI-MS/MS with dioctylamine being the dominant quantifiable species. Both 243 Am and 154 Eu distribution ratios exhibited an induction period of ~70 kGy for extraction (0.1 M HNO 3 ) and back-extraction (4.0 M HNO 3 ) conditions, after which both values decreased with absorbed dose. The decrease in distribution ratios was attributed to a combination of the destruction of HONTA and ingrowth of dioctylamine, which is capable of interfering in metal ion complexation. Furthermore, the loss of HONTA with absorbed gamma dose was predominantly attributed to its reaction with the n-dodecane radical cation (R˙ + ). These R˙ + reaction kinetics were measured for HONTA and its 241 Am and 154 Eu complexes using picosecond pulsed electron radiolysis techniques. All three second-order rate coefficients (k) were essentially diffusion limited in n-dodecane indicating a significant reaction pathway: k(HONTA + R˙ + ) = (7.6 ± 0.8) × 10 9 M –1 s –1 , k(Am(HONTA) 2 + R˙ + ) = (7.1 ± 0.7) × 10 10 M –1 s –1 , and k(Eu(HONTA) 2 + R˙ + ) = (9.5 ± 0.5) × 10 10 M –1 s –1 . HONTA-metal ion complexation afforded an order-of-magnitude increase in rate coefficient. Additional nanosecond time-resolved measurements showed that both direct and indirect HONTA radiolysis yielded the short-lived (< 100 ns) HONTA radical cation and a second long-lived (µs) species identified as the HONTA triplet excited state. The latter was confirmed by a series of oxygen quenching picosecond pulsed electron measurements, affording a quenching rate coefficient of k( 3 [HONTA]* + O 2 ) = 2.2 × 10 8 M –1 s –1 . Overall, both the HONTA radical cation and triplet excited state are important precursors to the suite of measured HONTA degradation products.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Cable Condition Monitoring Strategy for Safe and Reliable Plant Operation

Electrical cables provide essential functions, such as delivery of power or instrumentation signals for monitoring systems. Most cables installed in industrial applications are constructed with organic polymer insulations that can become brittle, crack, or degrade over time from exposure to harsh environmental conditions, such as elevated temperatures, moisture, vibration, mechanical shock, and radiation. This paper describes an overall strategy for assessing the health and managing the aging of cables during the operating life of an industrial facility. This strategy involves performing condition assessments and monitoring of electrical cables using both in situ and laboratory testing techniques. It includes in situ testing to identify anomalies in the circuits, such as degraded terminations, splices, connections, and degraded sections of cable insulation, as well as as-found evaluations to determine the current condition of installed cables. Furthermore, these cable condition evaluations provide important information about the current state of the cable circuits. Moreover, the test results can be used to trend/monitor age-related degradation and estimate the remaining useful life of installed cables.

36 MATERIALS SCIENCE↗

Interpretive modelling of boron transport in the boundary plasma of WEST experiments with the impurity powder dropper

Abstract Boron (B) powder injection is a potential alternative to glow discharge boronization as a wall conditioning method for tokamaks. This technique is currently being studied in WEST experiments, during which B powder is injected by an Impurity Powder Dropper developed by PPPL. In order to interpret and analyse experimental trends, and to help develop future experiments, a modelling workflow using a boundary plasma simulation (SOLEDGE-EIRENE) and powder ablation simulation (Dust Injection Simulator) was developed and tested. The effect of adding a B neutral source to simulated deuterium + oxygen (D + O) plasmas was compared to experimental data from the WEST C5 campaign, where B powder was injected in a dedicated experiment. While the impact of B injection on radiated power P rad measurements at the upper divertor was similar, there were significant differences in measurements of P rad , outer strike point electron temperature T e OSP and O-II line intensity at the lower divertor between experiment and simulation. This discrepancy suggests that those parameters were affected by phenomena not present in the simulations, with the most likely candidates being reduced D recycling and a reduced O sourcing from the divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗