Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

CMOS imager for pointing and tracking applications

Systems and techniques to realize pointing and tracking applications with CMOS imaging devices. In general, in one implementation, the technique includes: sampling multiple rows and multiple columns of an active pixel sensor array into a memory array (e.g., an on-chip memory array), and reading out the multiple rows and multiple columns sampled in the memory array to provide image data with reduced motion artifact. Various operation modes may be provided, including TDS, CDS, CQS, a tracking mode to read out multiple windows, and/or a mode employing a sample-first-read-later readout scheme. The tracking mode can take advantage of a diagonal switch array. The diagonal switch array, the active pixel sensor array and the memory array can be integrated onto a single imager chip with a controller. This imager device can be part of a larger imaging system for both space-based applications and terrestrial applications.

Pain, Bedabrata↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗

Deployment and performance of a Low-Energy-Threshold Skipper-CCD inside a nuclear reactor

Charge Coupled Devices (CCD) are being used for reactor neutrino experiments and have already demonstrated their potential in constraining new physics models. The prospect of a Skipper-CCD experiment looking for standard and beyond standard model (BSM) physics in a nuclear reactor has been evaluated for different benchmark scenarios. Here, we report the first installation of a 2-g Skipper-CCD inside the containment building of a 2 GW th nuclear power plant and analyze its performance throughout its first 18 months of operation. The sensor was successfully deployed at Atucha II, in Argentina, 12 meters away from the center of the reactor core. We discuss the challenges involved in the commissioning of the detector and present data acquired during reactor ON and reactor OFF periods, with the sensor functioning with a sub-electron readout noise of 0.17 e - . Based on an exposure of 56.8 g day reactor ON and two reactor OFF data sets with a total exposure of 118.1 g day we characterize the system and evaluate the sensitivity to CEvNS. We achieved a background rate of 33 kdru and a low threshold of 45 eV ee . The ongoing efforts to improve sensitivities to CEvNS and BSM interaction are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The use of workflows in the design and implementation of complex experiments in macromolecular crystallography

A powerful and easy-to-use workflow environment has been developed at the ESRF for combining experiment control with online data analysis on synchrotron beamlines. This tool provides the possibility of automating complex experiments without the need for expertise in instrumentation control and programming, but rather by accessing defined beamline services. The automation of beam delivery, sample handling and data analysis, together with increasing photon flux, diminishing focal spot size and the appearance of fast-readout detectors on synchrotron beamlines, have changed the way that many macromolecular crystallography experiments are planned and executed. Screening for the best diffracting crystal, or even the best diffracting part of a selected crystal, has been enabled by the development of microfocus beams, precise goniometers and fast-readout detectors that all require rapid feedback from the initial processing of images in order to be effective. All of these advances require the coupling of data feedback to the experimental control system and depend on immediate online data-analysis results during the experiment. To facilitate this, a Data Analysis WorkBench (DAWB) for the flexible creation of complex automated protocols has been developed. Here, example workflows designed and implemented using DAWB are presented for enhanced multi-step crystal characterizations, experiments involving crystal reorientation with kappa goniometers, crystal-burning experiments for empirically determining the radiation sensitivity of a crystal system and the application of mesh scans to find the best location of a crystal to obtain the highest diffraction quality. Beamline users interact with the prepared workflows through a specific brick within the beamline-control GUI MXCuBE.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Precision Timing in CMS at the HL-LHC: Current Progress on Validation and Production

During the High Luminosity phase of LHC, up to 200 proton-proton collisions per bunch crossing will bring severe challenges for event reconstruction. To mitigate pileup effects, an extended upgrade program of the CMS experiment is expected. Among which, a new timing layer, the MIP Timing Detector (MTD), will be integrated between the tracker and the calorimeters. With a time resolution of 30-60 ps, the MTD will enable 4D vertexing, bringing significant improvements in track-to-vertex association and object identification. The MTD is composed of two subsystems based on different technologies: the Barrel Timing Layer (BTL) consists of LYSO:Ce scintillating crystals readout by SiPMs, and the Endcap Timing Layer (ETL) is made of Low-Gain Avalanche Diodes. The BTL is currently under production, while ETL sensor prototyping and validation are ongoing. Recent system tests have confirmed the performance of the full acquisition chain. This talk will provide an overview of the MTD design, along with the physics motivation, and the current status of BTL construction and ETL development.

Safdari, Murtaza [Fermilab] (ORCID:000000018323731↗

Engineered Cell Line Imaging Assay Differentiates Pathogenic from Non-Pathogenic Bacteria

Cell culture systems have greatly expanded our understanding of how bacterial pathogens target signaling pathways to manipulate the host and cause infection. Advances in genetic engineering have allowed for the creation of fluorescent protein readouts within signaling pathways, but these techniques have been underutilized in pathogen biology. Here, we genetically engineered a lung cell line with fluorescent reporters for extracellular signal-related kinase (ERK) and the downstream transcription factor FOS-related antigen 1 (Fra1) and evaluated signaling after inoculation with pathogenic and non-pathogenic bacteria. Cells were inoculated with 100 colony-forming units of Acinetobacter baylyi, Klebsiella pneumoniae, Pseudomonas aeruginosa, Streptococcus agalactiae, or Staphylococcus epidermidis and imaged in a multi-mode reader. The alamarBlue cell viability assay was used as a reference test and showed that pathogenic P. aeruginosa induced significant (p < 0.05) cell death after 8 h in both wild-type and engineered cell lines compared to non-pathogenic S. epidermidis. In engineered cells, we found that Fra1 signaling was disrupted in as little as 4 h after inoculation with bacterial pathogens compared to delayed disruption in signaling by non-pathogenic S. epidermidis. Overall, we demonstrate that low levels of pathogenic versus non-pathogenic bacteria can be rapidly and sensitively screened based on ERK-Fra1 signaling

59 BASIC BIOLOGICAL SCIENCES↗

Microparticle Flow Sensor

The microparticle flow sensor (MFS) is a system for identifying and counting microscopic particles entrained in a flowing liquid. The MFS includes a transparent, optoelectronically instrumented laminar-flow chamber (see figure) and a computer for processing instrument-readout data. The MFS could be used to count microparticles (including micro-organisms) in diverse applications -- for example, production of microcapsules, treatment of wastewater, pumping of industrial chemicals, and identification of ownership of liquid products.

Morrison, Dennis R.↗

Optimization of the light detection system of the ICARUS detector

The ICARUS detector, a key component of the Short Baseline Neutrino (SBN) Program at Fermi National Acelerator Laboratory (FNAL), is a 600-ton Liquid Argon Time Projection Chamber (LArTPC) equipped with a Light Detection System (LDS) that uses 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), specifically designed to operate under cryogenic conditions ($\sim 87 \ K$). These PMTs feed the trigger signal to the readout, improve the spatial and timing resolution of the events, and contribute to cosmic rays mitigation. During operation at FNAL, a progressive degradation in the PMT gain was observed. We developed an experimental setup to investigate the temperature dependence of PMT performance. Gain measurements were carried out from room temperature to $-70 ^\circ C$ using an environmental chamber. The results show that, while the PMTs exhibit stable performance at room temperature, a significant and irreversible reduction in gain emerges at lower temperatures. Al though $-70 ^\circ C$ remains above the liquid argon temperatures, the trend clearly reveals a gain-sensitive degradation mechanism. A simplified physical model was developed to reproduce and interpret the observed behavior. Based on these findings, a series of mitigation strategies were implemented in the ICARUS detector to preserve PMT performance and ensure reliable operation under cryogenic conditions.

Saia, C. [Catania Astrophys. Observ.]↗

Low-cost tape system measures velocity of acceleration

By affixing perforated magnetic recording tape to the falling end of a body, acceleration and velocity were measured. The measurement was made by allowing the tape to pass between a light source and a photoelectric sensor. Data was obtained from a readout device.

Hartenstein, R.↗

Improved Protein Arrays for Quantitative Systems Analysis of the Dynamics of Signaling Pathway Interactions

Astronauts and workers in nuclear plants who repeatedly exposed to low doses of ionizing radiation (IR, <10 cGy) are likely to incur specific changes in signal transduction and gene expression in various tissues of their body. Remarkable advances in high throughput genomics and proteomics technologies enable researchers to broaden their focus from examining single gene/protein kinetics to better understanding global gene/protein expression profiling and biological pathway analyses, namely Systems Biology. An ultimate goal of systems biology is to develop dynamic mathematical models of interacting biological systems capable of simulating living systems in a computer. This Glue Grant is to complement Dr. Boothman’s existing DOE grant (No. DE-FG02-06ER64186) entitled “The IGF1/IGF-1R-MAPK-Secretory Clusterin (sCLU) Pathway: Mediator of a Low Dose IR-Inducible Bystander Effect” to develop sensitive and quantitative proteomic technology that suitable for low dose radiobiology researches. An improved version of quantitative protein array platform utilizing linear Quantum dot signaling for systematically measuring protein levels and phosphorylation states for systems biology modeling is presented. The signals are amplified by a confocal laser Quantum dot scanner resulting in ~1000-fold more sensitivity than traditional Western blots and show the good linearity that is impossible for the signals of HRP-amplification. Therefore this improved protein array technology is suitable to detect weak responses of low dose radiation. Software is developed to facilitate the quantitative readout of signaling network activities. Kinetics of EGFRvIII mutant signaling was analyzed to quantify cross-talks between EGFR and other signaling pathways.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrated system tests of the LSST raft tower modules

The science focal plane of the LSST camera is made up of 21 fully autonomous 144 Mpixel imager units designated raft tower modules (RTM). These imagers incorporate nine 4K x 4K fully-depleted CCDs and 144 channels of readout electronics, including a dedicated CMOS video processing ASIC and components that provide CCD biasing and clocking, video digitization, thermal stabilization, and a high degree of monitoring and telemetry. Here, the RTM achieves its performance goals for readout speed, read noise, linearity, and crosstalk with a power budget of less than 400mW/channel. Series production is underway on the first units and the production will run until 2018. We present the RTM final design, tests of the integrated signal chain, and performance results for the fully-integrated module with pre-production CCDs.

42 ENGINEERING↗

SCEMA: a high channel density electronics module for fast waveform capture

The development of fast, highly pixelated photodetectors with single-photon sensitivity has the potential to enable a variety of new radiation detection concepts. Systems that desire to employ these detectors without loss of information demand waveform digitization with high sampling rates. Switched capacitor arrays provide a low-cost, low-power, compact solution to fast readout with high channel density. The Sandia Laboratories Compact Electronics for Modular Acquisition (SCEMA) was developed to meet these demands. A single module employs two domino ring sampling switched capacitor arrays (DRS4) [1] to provide 16 channels of up to 5 GS/s waveform digitization. This paper presents an overview of the board design and function. Calibration procedures for the module are discussed. Lastly, temporal resolution tests are presented demonstrating the module's viability as readout for high fidelity temporal measurements of single photons in suitable photodetectors.

47 OTHER INSTRUMENTATION↗

Backaction-evading receivers with magnetomechanical and electromechanical sensors

Today's mechanical sensors are capable of detecting extremely weak perturbations while operating near the standard quantum limit. However, further improvements can be made in both sensitivity and bandwidth when we reduce the noise originating from the process of measurement itself—the quantum-mechanical backaction of measurement—and go below this ‘standard’ limit, possibly approaching the Heisenberg limit. One of the ways to eliminate this noise is by measuring a quantum nondemolition variable such as the momentum in a free-particle system. Here, we propose and characterize theoretical models for direct velocity measurement that utilize traditional electric and magnetic transducer designs to generate a signal while enabling this backaction evasion. We consider the general readout of this signal via electric or magnetic field sensing by creating toy models analogous to the standard optomechanical position-sensing problem, thereby facilitating the assessment of measurement-added noise. Using simple models that characterize a wide range of transducers, we find that the choice of readout scheme—voltage or current—for each mechanical detector configuration implies access to either the position or velocity of the mechanical subsystem. This in turn suggests a path forward for key fundamental physics experiments such as the direct detection of dark matter particles. Published by the American Physical Society 2024

74 ATOMIC AND MOLECULAR PHYSICS↗

Implementing machine learning methods on QICK hardware for qubit readout & control

Quantum readout and control is a fundamental aspect of quantum computing that requires accurate measurement of qubit states. Errors emerge in all stages, from initialization to readout, and identifying errors in post-processing necessitates resource-intensive statistical analysis. In our work, we use a lightweight fully-connected neural network (NN) to classify states of a transmon system with no prior processing. Our NN accelerator yields higher fidelities (92%) than the classical matched filter method (84%). By exploiting the natural parallelism of NNs and their placement near the source of data on field-programmable gate arrays (FPGAs), we can achieve ultra-low latency on the Quantum Instrumentation Control Kit (QICK). Integrating machine learning methods on QICK opens several pathways for efficient real-time processing of quantum circuits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time delay and integration detectors using charge transfer devices

An imaging system comprises a multi-channel matrix array of CCD devices wherein a number of sensor cells (pixels) in each channel are subdivided and operated in discrete intercoupled groups of subarrays with a readout CCD shift register terminating each end of the channels. Clock voltages, applied to the subarrays, selectively cause charge signal flow in each subarray in either direction independent of the other subarrays. By selective application of four phase clock voltages, either one, two or all three of the sections subarray sections cause charge signal flow in one direction, while the remainder cause charge signal flow in the opposite direction. This creates a form of selective electronic exposure control which provides an effective variable time delay and integration of three, six or nine sensor cells or integration stages. The device is constructed on a semiconductor sustrate with a buried channel and is adapted for front surface imaging through transparent doped tin oxide gates.

Mccann, D. H.↗

The QWIP Focal Plane Assembly for NASA's Landsat Data Continuity Mission

The Thermal Infrared Sensor (TIRS) is a QWIP based instrument intended to supplement the Operational Land Imager (OLI) for the Landsat Data Continuity Mission (LDCM). The TIRS instrument is a dual channel far infrared imager with the two bands centered at 10.8 m and 12.0 m. The focal plane assembly (FPA) consists of three 640x512 GaAs Quantum Well Infrared Photodetector (QWIP) arrays precisely mounted to a silicon carrier substrate that is mounted on an invar baseplate. The two spectral bands are defined by bandpass filters mounted in close proximity to the detector surfaces. The focal plane operating temperature is 43K. The QWIP arrays are hybridized to Indigo ISC9803 readout integrated circuits (ROICs). Two varieties of QWIP detector arrays are being developed for this project, a corrugated surface structure QWIP and a grating surface structure QWIP. This paper will describe the TIRS system noise equivalent temperature difference sensitivity as it affects the QWIP focal plane performance requirements: spectral response, dark current, conversion efficiency, read noise, temperature stability, pixel uniformity, optical crosstalk and pixel yield. Additional mechanical constraints as well as qualification through Technology Readiness Level 6 (TRL 6) will also be discussed.

Jhabvala, M.↗