Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power system stability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization

The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Fine Gradient Electrode and Micro Porous Layer Structures for Improved Heavy Duty Fuel Cells (Final Report)

The commercial deployment of Heavy Duty Fuel Cells(HDFC) for applications such as large trucks (for example, Class 8 capable of carrying 50,000 lb. loads) depends vitally on achieving high efficiency and durability at reasonable costs. Furthermore, the HDFC must operate under practical conditions such as with fuel and air impurities, multiple stop-start cycles, and under the extremes of climate our planet offers – from hot and cold to dry and wet. These conditions place a premium on the stability and utilization of the materials comprising the membrane electrode assemblies (MEAs) powering the fuel cell. and the current catalysts, MicroPorous Layers, and Electrode structures and additives are insufficient for these needs. In Phase I Pajarito and Advent will develop durable electrocatalysts, MicroPorous Layer and electrode additives, and electrode structures for heavy duty fuel cells designed for zero-emission long-haul trucking. The electrocatalyst products are designed to solve the challenging durability and performance needs of fuel cells designed for long life and high efficiency through a combination of uniquely structured designed catalysts as well as new MicroPorous Layers (MPLs) and electrode structure additives. These improved materials will provide Pajarito both an expanded commercial opportunity in electrocatalysts, as well as new markets for MPL and electrode additives. The resulting public benefits include improved economics of fuel cells, a leading zero-emission technology for mobility, as well as reduced reliance on the critical minerals and metals used in the heavy-duty trucks industry. Possible follow-up Phase II and III projects would add full MEA products based on the Phase I efforts catalysts and additives, with full system validation by leading Fuel Cell Truck developers.

08 HYDROGEN↗

Voltage Optimization

Voltage optimization refers to a volt-var optimization technique which was originally designed to minimize energy consumption and improve end-use efficiency on the distribution system. This reduces source voltage at a substation, which lowers generation demand, reduces system losses, and improves system stability. This has been the conventional implementation of voltage optimization: focusing on regulation of voltages throughout the distribution system via coordinated adjustments of load tap changers, line-voltage regulators, switched shunt compensation, and the targeted placement of new shunt compensation. These methods have received increased focus following a growth in distributed-energy resources (DERs) interconnecting at the distribution level, given their developing capability to participate in voltage regulation. This is paired with the intermittency challenges they pose, load imbalances, and voltage fluctuations. Voltage optimization has long been an area of extensive research within the distribution system, with various strategies and philosophies demonstrating a range of effects. The conventional focus on the distribution system owes to the typical operation of transmission systems, which assumes firm local resources and flows strictly from generation resources to loads. The strategies employed in distribution have also been optimized for this typically radial configuration and operation of the distribution system.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Stability of Polyethylene Glycol-Coated Copper Nanoparticles and Their Optical Properties

Oxidation is a corrosion reaction where the corroded metal forms an oxide. Prevention of oxidation at the nanoscale is critically important to retain the physicochemical properties of metal nanoparticles. In this work, we studied the stability of polyethylene glycol (PEG) coated copper nanoparticles (PEGylated CuNPs) against oxidation. The freshly-prepared PEGylated CuNPs mainly consist of metallic Cu which are quite stable in air although their surfaces are typically covered with a few monolayers of cuprous oxide. However, they are quickly oxidized in water due to the presence of protons that facilitate oxidation of the cuprous oxide to cupric oxide. PEG with carboxylic acid terminus could slightly delay the oxidation process compared to that with thiol terminus. It was found that a solvent with reducing power such as ethanol could greatly enhance the stability of PEGylated CuNPs by preventing further oxidation of the cuprous oxide to cupric oxide and thus retain the optical properties of CuNPs. The reducing environment also assists the galvanic replacement of these PEGylated CuNPs to form hollow nanoshells; however, they consist of ultra-small particle assemblies due to the co-reduction of gold precursor during the replacement reaction. As a result, these nanoshells do not exhibit strong optical properties in the near-infrared region. This study highlights the importance of solvent effects on PEGylated nonprecious metal nanoparticles against oxidation corrosion and its applications in preserving physicochemical properties of metallic nanostructures.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

T&D LIBRA: Simulation Framework for Transmission and Distribution Load and IBR Assessment

This paper introduces T&D LIBRA, a HELICS-based dynamic co-simulation framework designed for transmission and distribution (T&D) load and inverter-based resource assessment. This framework is designed to model interactions between single-phase induction motors (i.e., Motor-D), distributed energy resources (DERs) and the transmission network, emphasizing system stability during fault conditions. The primary objective of this research is to study the fault-induced delayed voltage recovery (FIDVR) behavior of the T&D networks using the co-simulation framework and to compare the results with conventional PSS/E only simulations. Simulations are validated using T&D co-simulations with a single distribution node and the IEEE 123-bus distribution test case. The co-simulation results demonstrate the value of using T&D co-simulations to capture motor stalling, DER tripping and other sources of voltage diversity on distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bayesian batch optimization for molybdenum versus tungsten inertial confinement fusion double shell target design

Access to reliable, clean energy sources is a major concern for national security. Much research is focused on the “grand challenge” of producing energy via controlled fusion reactions in a laboratory setting. For fusion experiments, specifically inertial confinement fusion (ICF), to produce sufficient energy, the fusion reactions in the ICF fuel need to become self-sustaining and burn deuterium-tritium (DT) fuel efficiently. The recent record-breaking NIF ignition shot was able to achieve this goal as well as produce more energy than used to drive the experiment. This achievement brings self-sustaining fusion-based power systems closer than ever before, capable of providing humans with access to secure, renewable energy. In order to further progress toward the actualization of such power systems, more ICF experiments need to be conducted at large laser facilities such as the United States's National Ignition Facility (NIF) or France's Laser Mega-Joule. The high cost per shot and limited number of shots that are possible per year make it prohibitive to perform large numbers of experiments. As such, experimental design relies heavily on complex predictive physics simulations for high-fidelity “preshot” analysis. These multidimensional, multi-physics, high-fidelity simulations have to account for a variety of input parameters as well as modeling the extreme conditions (pressures and densities) present at ignition. Such simulations (especially in 3D) can become computationally prohibitive to turn around for each ICF experiment. In this work, we explore using Bayesian optimization with Gaussian processes (GPs) to find optimal designs for ICF double shell targets, while keeping computational costs to manageable levels. These double shell targets have an inner shell that grades from beryllium on the outer surface to the higher Z material molybdenum, as opposed to the nominally used tungsten, on the inside in order to trade off between the high performance associated with high density inner shells and capsule stability. We describe our results for “capsule-only” xRAGE simulations to study the physics between different capsule designs, inner shell materials, and potential for future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dielectric constant engineering of nonfullerene acceptors enables a record fill factor of 83.58% and a high efficiency of 20.80% in organic solar cells

Organic solar cells (OSCs) have achieved power conversion efficiencies (PCEs) surpassing 20%, but their development remains hindered by the inherently low dielectric constant (εr) of organic semiconductors, which limits charge transport and contributes to serious recombination losses. Herein, we present a comprehensive strategy to overcome the challenge by engineering the dielectric properties of nonfullerene acceptors (NFAs). Two Y-series NFAs of BTP-N3F and BTP-C3F have been synthesized featuring trifluoromethyl (CF 3 ) end-capped alkyl side chains. This molecular design significantly enhances the dipole moment and ε r (up to ∼5.9) when compared to the reference acceptor Y6 (∼3), reducing the exciton binding energy (E b ) and improving charge transport. Furthermore, the incorporation of a high-εr polymer additive, poly(pentafluorostyrene) (PPFS), synergistically improves the active layer morphology and dielectric properties, enabling efficient charge extraction and reduced recombination losses. Devices based on the optimized D18-Cl/BTP-C3F system have achieved a record-high fill factor (FF) of 83.58% and an impressive PCE of 20.80%, setting a new benchmark for OSCs. Finally, our results underscore the pivotal role of ε r in enhancing device performance and establish a versatile pathway for advancing OSC efficiency and stability through molecular and morphological optimization.

36 MATERIALS SCIENCE↗

Overview and Commentary on Applying the Coordinated Vulnerability Disclosure Process to Photovoltaic System Devices

The rapid expansion of photovoltaic (PV) systems, particularly inverters, has introduced new cybersecurity challenges that threaten both local operations as well as the broader electrical grid’s stability. PV inverters, integrated into critical energy infrastructure are potential targets for cyber attacks due to vulnerabilities in firmware, remote access systems, and communication protocols. The Coordinated Vulnerability Disclosure (CVD) process, as defined by the Cybersecurity and Infrastructure Security Agency (CISA), provides a framework for identifying, reporting, and addressing these vulnerabilities in a transparent and collaborative manner. This report outlines the CVD process as it applies to PV systems, detailing the roles of key stakeholders, such as manufacturers, grid operators, and security researchers. The report also highlights specific challenges in managing vulnerabilities for new and legacy PV systems, which includes those introduced by insecure communications and third-party supply chain components. By adhering to the CVD process, the PV industry can mitigate cybersecurity risks, ensure regulatory compliance, and maintain consumer trust, while safeguarding the operational resilience of the energy grid. Ultimately, the effective coordination of vulnerability management is crucial for securing the future of PV systems within the critical electric grid infrastructure landscape.

14 SOLAR ENERGY↗

All Solid State Batteries Enabled by Multifunctional Electrolyte Materials

Solid Power has teamed with University of California San Diego to develop a high energy, long life, low cost, and safe all-solid-state-battery (ASSB). The battery is enabled by a multifunctional solid state electrolyte (SSE). The project enables scalable production of large format solid state batteries required by the vehicle market and building domestic battery manufacturers as leaders in the global vehicle ASSB production. In the project, the multifunctional SSE materials have been developed and optimized with ionic conductivity ≥ 5 mS/cm and electrochemical stability 0 – 4.5V. SSE separator films have been coated by using a roll-to-roll process with thickness ≤ 40 µm. All-solid-state NMC-Li pouch cells containing the developed SSE have been assembled. A cycle life of > 750 at 100% DOD and 45 °C has been demonstrated in a full pouch cell.

25 ENERGY STORAGE↗

Organic superbases in Lewis pair catalyzed hydrogenations of imines

Organic superbases have recently emerged as powerful components in metal-free catalytic systems, yet their role in frustrated Lewis pair (FLP) catalyzed hydrogenation reactions remain underexplored. In this article, we investigate the diphosphazene superbases P 2 - t Bu (1) and P 2 -Et (2) as base components combined with electronically tunable boranes of formula 9-(X n -C 6 H 5-n )BBN, where X n = 4-NMe₂, 4-OMe, 4-Me, 4-H, 4-F, 4-OCF 3 , 4-CF 3 , 3,5-(CF3), in FLP-catalyzed hydrogenations of imines. While the more sterically encumbered base 1 forms persistent FLPs whose activity correlates with the hydride affinity of the borane, less hindered base 2 generates Lewis acid–base adducts and displays superior catalytic performance, especially with boranes of lower hydride affinity. A systematic screening identified the adduct 2/9-(4-MeO-C 6 H 4 )BBN as the most active catalytic system, achieving quantitative hydrogenation of N-benzylidene aniline at 80 °C and H 2 pressures as low as 40 bar in THF. Multinuclear NMR spectroscopic studies and DFT calculations support a mechanistic scenario in which reversible adduct formation and subsequent dissociation to the free acid–base pair precede heterolytic H₂ cleavage, with adduct stability and borane electrophilicity concurrently dictating catalytic activity. Under optimized conditions, the most active catalyst system, 2/9-(4-MeO-C 6 H 4 )BBN, hydrogenates a broad range of aldimines, including electron-rich 4-NMe₂ and push-pull substrates, mono- and bis-ortho-substituted imines, and selected heteroaryl imines, with excellent yields and selectivity. Collectively, these findings establish design principles for tuning BBN-derived FLP systems and expand the scope of metal-free hydrogenation catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data for "Land-based Resources for Engineered Carbon Dioxide Removal in the United States Exceed the Expected Needs"

Gigatonne-scale atmospheric carbon dioxide removal (CDR), alongside deep emission cuts, is critical to stabilizing the climate. However, some of the most scalable CDR technologies are also the most land intensive. Here, we examine whether adequate land resources exist in the contiguous United States to meet CDR targets when prioritizing grid emissions reduction, food production, and the protection of sensitive ecosystems. We focus on biomass carbon removal and storage (BiCRS) and direct air capture and storage (DACS) and show that suitable lands exceed the expected needs: 37.6 million hectares of land are available for BiCRS, resulting in 0.26 GtCO2 of CDR/year, and 34 million hectares are suitable for wind- and solar-powered DACS, resulting in 4.8 GtCO2 of CDR/year if facilities are co-located with geologic CO2 storage. We identify biomass and energy supply hotspots to meet CDR targets while ensuring land protection and minimizing land competition.

carbon↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

The Role of Nuclear-Conventional Intermingling on State Decision-making and the Risk of Inadvertent Escalation

The questions answered by this report are: What are the implications of nuclear and conventional intermingling on crisis stability and the potential risk of miscalculation?, and Specifically, how might entanglement influence US and competitor decision making during crisis and conflict? In practice, there are three main forms of nuclear-conventional intermingling. First, intermingling between nuclear and non-nuclear weapon systems can occur via the fielding of dual capable delivery systems like missiles or aircraft. Second, intermingling can happen due to the co-location of nuclear and non-nuclear forces and their support structures—for example, the co-location of strategic bombers and general-purpose aircraft, or the co-location of strategic submarines and general-purpose vessels. Third, intermingling can occur via convolving nuclear and conventional military command and control systems, to include ballistic missile early warning and potentially space surveillance systems as well. All three forms of nuclear-conventional intermingling have significantly increased since the end of the Cold War, driven by both technological and doctrinal changes. However, there are important differences in the rationale behind, and also the risks associated with these three different forms of intermingling. The mere existence of dual capable systems is not new— deploying such systems can increase the effectiveness of forces, and it can also provide more flexibility. The major powers have both employed and threatened with dual capable systems for decades, and they have done so without nuclear escalation. Similarly, the major powers co-located nuclear and conventional systems in the Cold War, and they did so for variety of reasons that had nothing to do with complicating the adversary’s risk calculus. The Soviet Union, for example, decided to co-locate its nuclear and conventional forces for economic and administrative reasons. Although today it might be recognized as a useful deterrent tool, it was not their primary intention. Major powers want to convince rivals that the co-location of forces creates a high bar for targeting and raises the risk of nuclear escalation, but they also want to have the flexibility of this not being true in an actual crisis or conflict.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modular Staged Pressurized Oxy-Combustion (SPOC) Power Plant for Coal and Biomass – Integration of Combustor Boiler and DCC

Utilities and grid operators worldwide are under significant pressure to incorporate intermittent renewable sources while strategizing on how to maintain the necessary stability and reliability of the grid. The development of a power plant which will be capable of flexible operation to meet the needs of the grid as more intermittent sources like wind and solar energy are incorporated is key to maintain the reliability of the grid. Through the use of innovative and cutting-edge technologies that improve efficiency and reduce carbon emissions, and being small compared to today's conventional utility-scale power plants, the modular Staged, Pressurized Oxy-Combustion (SPOC) process envisioned by and under development at Washington University in St. Louis (WUSTL) has the potential to achieve these goals. Specifically, the process offers: 1) a modular plant design that allows for better operational flexibility; 2) the utilization of fuel-staging and pressurized oxy-combustion, resulting in smaller plant size, improved plant efficiency, and reduced costs for pollutant and CO2 removal compared to traditional power plants with post-combustion capture technology; and 3) the use of small modular boilers and pollutant removal units that can be constructed off-site leading to reduced capital costs for the plant. WUSTL is advancing the development of the critical components for the SPOC power plant, including the integrated combustor-boiler system and the direct contact cooler. To demonstrate the boiler convective section and to obtain critical data for commercial-scale pressurized boiler design, a simulated convective heat transfer boiler test section was designed and integrated with the combustor (radiant section). A direct contact cooler (DCC) was integrated with the combustor-boiler to demonstrate the dynamic operation of the integrated system and the performance of the DCC, including the efficiency for simultaneous removal of NOx and SOx. This talk will present an update on the evaluation of the critical components for system integration, including heat transfer data from the simulated boiler, scrubbing efficiency for the DCC under different operating conditions, and CFD modeling and validation for burner and boiler development.

Magalhaes, Duarte↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Initial Results on a New Light-Duty 2.7-L Opposed-Piston Gasoline Compression Ignition Multi-Cylinder Engine

Abstract Gasoline compression ignition (GCI) is a cost-effective approach to achieving diesel-like efficiencies with low emissions. The fundamental architecture of the two-stroke Achates Power Opposed-Piston (OP) Engine enables GCI by decoupling piston motion from cylinder scavenging, allowing for flexible and independent control of cylinder residual fraction and temperature leading to improved low-load combustion. In addition, the high peak cylinder pressure and noise challenges at high-load operation are mitigated by the lower brake mean effective pressure (BMEP) operation and faster heat release for the same pressure rise rate of the OP Engine. These advantages further solidify the performance benefits of the OP Engine and demonstrate the near-term feasibility of advanced combustion technologies, enabled by the opposed-piston architecture. This paper presents initial results from steady-state testing on a brand new 2.7-L OP GCI multi-cylinder engine (MCE) designed for light-duty truck applications. Successful GCI operation calls for a high compression ratio (CR), leading to higher combustion stability at low loads, higher efficiencies, and lower cycle HC + NOX emissions. Initial results show a cycle average brake thermal efficiency (BTE) of 31.7%, which is already greater than 11% conventional engines, after only ten weeks of testing. Emissions results suggest that Tier 3 Bin 160 levels can be achieved using a traditional diesel after-treatment system. Combustion noise was well controlled at or below the United States Council for Automotive Research limits. In addition, initial results on catalyst light-off mode with GCI are also presented.

Energy & Fuels↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗