Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs), which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This study presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

43 PARTICLE ACCELERATORS↗

A Crystal Structure of a Dimer of the Antibiotic Ramoplanin Illustrates Membrane Positioning and a Potential Lipid II Docking Interface

The glycodepsipeptide antibiotic ramoplanin A2 is in late stage clinical development for the treatment of infections from Gram-positive pathogens, especially those that are resistant to first line antibiotics such as vancomycin. Ramoplanin A2 achieves its antibacterial effects by interfering with production of the bacterial cell wall; it indirectly inhibits the transglycosylases responsible for peptidoglycan biosynthesis by sequestering their Lipid II substrate. Lipid II recognition and sequestration occur at the interface between the extracellular environment and the bacterial membrane. Therefore, we determined the structure of ramoplanin A2 in an amphipathic environment, using detergents as membrane mimetics, to provide the most physiologically relevant structural context for mechanistic and pharmacological studies. We report here the X-ray crystal structure of ramoplanin A2 at a resolution of 1.4 {angstrom}. This structure reveals that ramoplanin A2 forms an intimate and highly amphipathic dimer and illustrates the potential means by which it interacts with bacterial target membranes. The structure also suggests a mechanism by which ramoplanin A2 recognizes its Lipid II ligand.

36 MATERIALS SCIENCE↗

Stretched and Filtered Multigroup Pn Transport for Improved Positivity and Accuracy

One of the common methods for solving the radiation transport equation is to use a polynomial expansion for the angle variable(s). Recent research that reduces the oscillations and improves the positivity of the gray transport equation solutions is here applied to the multigroup transport equations. Constant scale factors that stretch the time axis and constant scattering opacities that filter the solution greatly increase the accuracy of the solution with no added nonlinearities. No new solution techniques are required. Test problems are presented in one and two dimensions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Architecture of a Silicon Strip Beam Position Monitor

A collaboration between Fermilab and the Institute for High Energy Physics (IHEP), Beijing, has developed a beam position monitor for the IHEP test beam facility. This telescope is based on 5 stations of silicon strip detectors having a pitch of 60 microns. The total active area of each layer of the detector is about 12 x 10 cm{sup 2}. Readout of the strips is provided through the use of VA1 ASICs mounted on custom hybrid printed circuit boards and interfaced to Adapter Cards via copper-over-kapton flexible circuits. The Adapter Cards amplify and level-shift the signal for input to the Fermilab CAPTAN data acquisition nodes for data readout and channel configuration. These nodes deliver readout and temperature data from triggered events to an analysis computer over gigabit Ethernet links.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Osteocalcin binds to a GPRC6A Venus fly trap allosteric site to positively modulate GPRC6A signaling

GPRC6A, a member of the Family C G-protein coupled receptors, regulates energy metabolism and sex hormone production and is activated by diverse ligands, including cations, L-amino acids, the osteocalcin (Ocn) peptide and the steroid hormone testosterone. We sought a structural framework for the ability of multiple distinct classes of ligands to active GPRC6A. We created a structural model of GPRC6A using Alphafold2. Using this model we explored a putative orthosteric ligand binding site in the bilobed Venus fly trap (VFT) domain of GPRC6A and two positive allosteric modulator (PAM) sites, one in the VFT and the other in the 7 transmembrane (7TM) domain. We provide evidence that Ocn peptides act as a PAM for GPRC6A by binding to a site in the VFT that is distinct from the orthosteric site for calcium and L-amino acids. In agreement with this prediction, alternatively spliced GPRC6A isoforms 2 and 3, which lack regions of the VFT, and mutations in the computationally predicted Ocn binding site, K352E and H355P, prevent Ocn activation of GPRC6A. These observations explain how dissimilar ligands activate GPRC6A and set the stage to develop novel molecules to activate and inhibit this previously poorly understood receptor.

59 BASIC BIOLOGICAL SCIENCES↗

Towards a deep characterization of a 64-fold-pixelated position sensitive detector for a new {gamma}-scanning system of HPGe segmented detectors

Characterization of the electrical response of the HPGe segmented detectors is one of the current goals for the Nuclear Physics community in order to perform {gamma}-ray tracking or even imaging with these detectors. For this purpose, scanning devices have to be developed to achieve the signal-position association with the highest precision. In this laboratory, a new scanning system, SALSA (Salamanca Lyso-based Scanning Array), consisting on a high spatial resolution {gamma} camera, is a under development. In this work the whole scanning system is presented and first results for the characterization of the {gamma} camera are shown. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic design of the RF cavity beam position monitor for the LCLS.

A high-resolution X-band cavity BPM has been developed for the LCLS. A dipole mode cavity and a monopole mode reference cavity have been designed in order to achieve micron-level accuracy of the beam position. The rf properties of the BPM as well as beam interaction with the cavities will be discussed including output power and tuning. In addition, methods will be presented for improving the isolation of the output ports to differentiate between horizontal/vertical beam motion and to reject extraneous modes from affecting the output signal. The predicted simulation results will be compared to data collected from low-power experimental tests.

43 PARTICLE ACCELERATORS↗

Performance Analysis of Positive-feedback-based Active Anti-islanding Schemes for Inverter-Based Distributed Generators

Recently proposed positive-feedback-based anti-islanding schemes (AI) are highly effective in preventing islanding without causing any degradation in power quality. This paper aims to analyze the performance of these schemes quantitatively in the context of the dynamic models of inverter-based distributed generators (DG). In this study, the characteristics of these active anti-islanding methods are discussed and design guidelines are derived.

24 POWER TRANSMISSION AND DISTRIBUTION↗

AMAROK: A Radio Frequency Development Platform for High-Power, Full-Scale Positive Ion Sources for DIII-D Neutral Beam Injectors

Next-generation neutral beam injection (NBI) systems demand RF ion sources capable of efficiently coupling >120 kW at 2–4-MHz frequencies, yet existing designs face voltage standoff and impedance-matching challenges. To address this, the advanced multicoil antenna for RF operations at kilowatts (AMAROK) was developed as a high-power RF inductively coupled plasma (ICP) source delivering up to 200 kW in the 2–4-MHz range via four phase-controlled generators for flexible power sharing. Two antenna designs—a single-strap multiturn (MT) and a multistrap single-turn (ST) design—were evaluated to optimize resonance, impedance matching, and power coupling across plasma loads. Here, a semi-analytical self-resonant frequency (SRF) model, validated experimentally, predicts resonance trends for arbitrary turn counts and tubing diameters, enabling rapid antenna optimization. Strap-to-strap mutual inductance in the ST configuration showed strong spatial dependence, guiding generator operation and total load inductance. These insights informed a custom π -topology matching network, achieving stable impedance matching over a wide range of plasma-driven loads. Collectively, these results position AMAROK as a versatile testbed for advancing high-power RF source technology in fusion NBI applications.

DIII-D↗

The Effect of Positioning on Ureteral Stone Retropulsion: “Gravity Works”

To evaluate the potential impact of alterations in “patient” position on laser-induced ureteral stone retropulsion in an in vitro model. In this paper, a ceramic (phantom) stone was placed in a water-filled clear polymer tube and subjected to continuous laser energy until the stone had retropulsed a distance of 10cm. The trial was stopped after 60 seconds if the stone had not reached 10cm. The time and total energy needed to cause 10cm of retropulsion were recorded at an incline angle of 0°, 10°, 20°, and 40°; ten trials at each angle were completed. The study was then repeated with pure calcium phosphate brushite stones. Retropulsion decreased with increasing incline angle of the saline-filled clear polymer tube. At 0° of incline the phantom stone reached a distance of 10cm after 7.4 seconds. At 10°, 20°, and 40° the phantom stone migrated a mean maximum distance of 3.1 cm, 1.2 cm, and 0.7 cm, respectively, and the trial was stopped after 60 seconds. For the calcium phosphate stone, at 0° and 10° of incline, the stone reached 10cm after 6.9 seconds and 42.8 seconds respectively (p<0.05). At 20° and 40°, the calcium phosphate stone moved a mean maximum distance of 2.4cm and 1cm, and the trial was stopped after 60 seconds. Alterations in the angle of inclination reduced stone retropulsion during ureteroscopic lithotripsy in an in vitro model to <1cm. Finally, increasing the incline angle of a patient may effectively preclude retropulsion when performing laser lithotripsy of ureteral stones.

60 APPLIED LIFE SCIENCES↗

Evaluation of similarity measures for use in the intensity-based rigid 2D-3D registration for patient positioning in radiotherapy

Purpose: Rigid 2D-3D registration is an alternative to 3D-3D registration for cases where largely bony anatomy can be used for patient positioning in external beam radiation therapy. In this article, the authors evaluated seven similarity measures for use in the intensity-based rigid 2D-3D registration using a variation in Skerl's similarity measure evaluation protocol. Methods: The seven similarity measures are partitioned intensity uniformity, normalized mutual information (NMI), normalized cross correlation (NCC), entropy of the difference image, pattern intensity (PI), gradient correlation (GC), and gradient difference (GD). In contrast to traditional evaluation methods that rely on visual inspection or registration outcomes, the similarity measure evaluation protocol probes the transform parameter space and computes a number of similarity measure properties, which is objective and optimization method independent. The variation in protocol offers an improved property in the quantification of the capture range. The authors used this protocol to investigate the effects of the downsampling ratio, the region of interest, and the method of the digitally reconstructed radiograph (DRR) calculation [i.e., the incremental ray-tracing method implemented on a central processing unit (CPU) or the 3D texture rendering method implemented on a graphics processing unit (GPU)] on the performance of the similarity measures. The studies were carried out using both the kilovoltage (kV) and the megavoltage (MV) images of an anthropomorphic cranial phantom and the MV images of a head-and-neck cancer patient. Results: Both the phantom and the patient studies showed the 2D-3D registration using the GPU-based DRR calculation yielded better robustness, while providing similar accuracy compared to the CPU-based calculation. The phantom study using kV imaging suggested that NCC has the best accuracy and robustness, but its slow function value change near the global maximum requires a stricter termination condition for an optimization method. The phantom study using MV imaging indicated that PI, GD, and GC have the best accuracy, while NCC and NMI have the best robustness. The clinical study using MV imaging showed that NCC and NMI have the best robustness. Conclusions: The authors evaluated the performance of seven similarity measures for use in 2D-3D image registration using the variation in Skerl's similarity measure evaluation protocol. The generalized methodology can be used to select the best similarity measures, determine the optimal or near optimal choice of parameter, and choose the appropriate registration strategy for the end user in his specific registration applications in medical imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of insertion speed and trocar stiffness on the accuracy of needle position for brachytherapy

Purpose: In prostate brachytherapy, accurate positioning of the needle tip to place radioactive seeds at its target site is critical for successful radiation treatment. During the procedure, needle deflection leads to seed misplacement and suboptimal radiation dose to cancerous cells. In practice, radiation oncologists commonly use high-speed hand needle insertion to minimize displacement of the prostate as well as the needle deflection. Effects of speed during needle insertion and stiffness of trocar (a solid rod inside the hollow cannula) on needle deflection are studied. Methods: Needle insertion experiments into phantom were performed using a 2{sup 2} factorial design (2 parameters at 2 levels), with each condition having replicates. Analysis of the deflection data included calculating the average, standard deviation, and analysis of variance (ANOVA) to find significant single and two-way interaction factors. Results: The stiffer tungsten carbide trocar is effective in reducing the average and standard deviation of needle deflection. The fast insertion speed together with the stiffer trocar generated the smallest average and standard deviation for needle deflection for almost all cases. Conclusions: The combination of stiff tungsten carbide trocar and fast needle insertion speed are important to decreasing needle deflection. The knowledge gained from this study can be used to improve the accuracy of needle insertion during brachytherapy procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interplay effects between dose distribution quality and positioning accuracy in total marrow irradiation with volumetric modulated arc therapy

Purpose: To evaluate the dosimetric consequences of inaccurate isocenter positioning during treatment of total marrow (lymph-node) irradiation (TMI-TMLI) using volumetric modulated arc therapy (VMAT).Methods: Four patients treated with TMI and TMLI were randomly selected from the internal database. Plans were optimized with VMAT technique. Planning target volume (PTV) included all the body bones; for TMLI, lymph nodes and spleen were considered into the target, too. Dose prescription to PTV was 12 Gy in six fractions, two times per day for TMI, and 2 Gy in single fraction for TMLI. Ten arcs on five isocenters (two arcs for isocenter) were used to cover the upper part of PTV (i.e., from cranium to middle femurs). For each plan, three series of random shifts with values between −3 and +3 mm and three between −5 and +5 mm were applied to the five isocenters simulating involuntary patient motion during treatment. The shifts were applied separately in the three directions: left–right (L-R), anterior–posterior (A-P), and cranial–caudal (C-C). The worst case scenario with simultaneous random shifts in all directions simultaneously was considered too. Doses were recalculated for the 96 shifted plans (24 for each patient).Results: For all shifts, differences <0.5% were found for mean doses to PTV, body, and organs at risk with volumes >100 cm{sup 3}. Maximum doses increased up to 15% for C-C shifted plans. PTV covered by the 95% isodose decreased of 2%–8% revealing target underdosage with the highest values in C-C direction.Conclusions: The correct isocenter repositioning of TMI-TMLI patients is fundamental, in particular in C-C direction, in order to avoid over- and underdosages especially in the overlap regions. For this reason, a dedicated immobilization system was developed in the authors' center to best immobilize the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-613: Dosimetric Consequences of Systematic MLC Leaf Positioning Errors

Purpose: The purpose of this study is to determine the dosimetric consequences of systematic MLC leaf positioning errors for clinical IMRT patient plans so as to establish detection tolerances for quality assurance programs. Materials and Methods: Dosimetric consequences were simulated by extracting mlc delivery instructions from the TPS, altering the file by the specified error, reloading the delivery instructions into the TPS, recomputing dose, and extracting dose-volume metrics for one head-andneck and one prostate patient. Machine error was simulated by offsetting MLC leaves in Pinnacle in a systematic way. Three different algorithms were followed for these systematic offsets, and are as follows: a systematic sequential one-leaf offset (one leaf offset in one segment per beam), a systematic uniform one-leaf offset (same one leaf offset per segment per beam) and a systematic offset of a given number of leaves picked uniformly at random from a given number of segments (5 out of 10 total). Dose to the PTV and normal tissue was simulated. Results: A systematic 5 mm offset of 1 leaf for all delivery segments of all beams resulted in a maximum PTV D98 deviation of 1%. Results showed very low dose error in all reasonably possible machine configurations, rare or otherwise, which could be simulated. Very low error in dose to PTV and OARs was shown in all possible cases of one leaf per beam per segment being offset (<1%), or that of only one leaf per beam being offset (<.2%). The errors resulting from a high number of adjacent leaves (maximum of 5 out of 60 total leaf-pairs) being simultaneously offset in many (5) of the control points (total 10–18 in all beams) per beam, in both the PTV and the OARs analyzed, were similarly low (<2–3%). Conclusions: The above results show that patient shifts and anatomical changes are the main source of errors in dose delivered, not machine delivery. These two sources of error are “visually complementary” and uncorrelated (albeit not additive in the final error) and one can easily incorporate error resulting from machine delivery in an error model based purely on tumor motion.

60 APPLIED LIFE SCIENCES↗

Kinetic theory of the positive column of a low-pressure discharge in a transverse magnetic field

The influence of a transverse magnetic field on the characteristics of the positive column of a planar low-pressure discharge is studied theoretically. The motion of magnetized electrons is described in the framework of a continuous-medium model, while the ion motion in the ambipolar electric field is described by means of a kinetic equation. Using mathematical transformations, the problem is reduced to a secondorder ordinary differential equation, from which the spatial distribution of the potential is found in an analytic form. The spatial distributions of the plasma density, mean plasma velocity, and electric potential are calculated, the ion velocity distribution function at the plasma boundary is found, and the electron energy as a function of the magnetic field is determined. It is shown that, as the magnetic field rises, the electron energy increases, the distributions of the plasma density and mean plasma velocity become asymmetric, the maximum of the plasma density is displaced in the direction of the Ampere force, and the ion flux in this direction becomes substantially larger than the counter-directed ion flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Positive column of a glow discharge in neon with charged dust grains (a review)

The effect of charged micron-size dust grains (microparticles) on the electric parameters of the positive column of a low-pressure dc glow discharge in neon has been studied experimentally and numerically. Numerical analysis is carried out in the diffusion-drift approximation with allowance for the interaction of dust grains with metastable neon atoms. In a discharge with a dust grain cloud, the longitudinal electric field increases. As the number density of dust grains in an axisymmetric cylindrical dust cloud rises, the growth of the electric field saturates. It is shown that the contribution of metastable atoms to ionization is higher in a discharge with dust grains, in spite of the quenching of metastable atoms on dust grains. The processes of charging of dust grains and the dust cloud are considered. As the number density of dust grains rises, their charge decreases, while the space charge of the dust cloud increases. The results obtained can be used in plasma technologies involving microparticles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Designing Li 4 Ti 5 O 12 /LiMn 2 O 4 Cells: Negative-to-Positive Ratio and Electrolyte

Li 4 Ti 5 O12/LiMn2O 4 (LTO/LMO) system is a promising candidate for behind-the-meter storage (BTMS) applications due to its critical-material-free chemistry exhibiting good safety and long lifetime. In this paper we design LTO/LMO cells to mitigate their major degradation mechanism, loss of Li inventory, and improve their long-term cyclability. First, LMO electrodes with different loadings (2.61, 3.29, and 4.26 mAh cm -2 ) are paired with an LTO electrode (3.35 mAh cm -2 ) to create varying negative-to-positive ratios (N/P>1, =1, and <1). Additionally, conventional ethylene carbonate (EC)/ethyl methyl carbonate (EMC) mixture electrolyte and safety enhanced EC-only electrolyte are examined. We show that storing additional Li inventory in the cathode (i.e., using a thicker electrode and having N/P<1) is a convenient method to enhance the capacity retention of LTO/LMO cells, but only if the electrode utilization is not limited by the Li + ion transport. For systems that suffer from limited transport properties, prelithiating the anode will be more effective since LTO (~165 mAh g -1 LTO ) can store the same amount of capacity using less material compared to LMO (~100 mAh g -1 LMO ). In this work, we demonstrate how the electrolyte properties and the electrode thickness of LTO/LMO cells can be designed to enhance their performance.

25 ENERGY STORAGE↗

Plastome evolution in annual Brachypodium species reveals widespread heteroplasmy and chloroplast capture, lineage-specific codon usage bias, and low positive selection

Comparative genomics and plastome phylogenomics have advanced significantly in recent years, highlighting the diversity, possible admixture, and non-neutral evolution of the predominantly considered non-recombinant chloroplast genomes in angiosperms. The grass genus Brachypodium serves as a powerful model for studying evolutionary processes in monocots. We analyzed 287 plastomes across the native circum-Mediterranean range of the three annual Brachypodium species ( B. distachyon, B. stacei, B. hybridum ), focusing on their structural variation, selection patterns and phylogenomic relationships. Our analyses confirmed the differentiation of the S and D plastomes, inherited respectively from the diploid progenitor species B. stacei and B. distachyon . We identified novel structural rearrangements and indels, and unique repeat motifs, along with widespread heteroplasmy, particularly in ancestral B. hybridum -D plastotypes. SNP diversity varied among plastotypes, reflecting population dynamics and evolutionary histories, with B. hybridum -D plastotypes showing the highest normalized diversity and B. hybridum -S the lowest. Positive selection was detected in 29 plastid genes by Tajima’s neutrality test, and in nine genes by site and branch-site evolutionary models, including matK, ndhF, rbcL, and rpoC2. Phylogenomic analyses revealed well-supported clades corresponding to the S and D plastome lineages, with frequent chloroplast capture events and long-distance dispersals shaping their evolutionary trajectories.

allopolyploidy↗