Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

New Soft X-ray Beamline (BL10) at the SAGA Light Source

A new soft X-ray beamline (BL10) at the SAGA Light Source (SAGA-LS) was constructed at the end of 2008. Commissioning of this new beamline started at the beginning of 2009. Synchrotron radiation from a variably polarizing undulator (APPLE-II) can be used in this beamline. The obtained light is monochromatized by a varied-line-spacing plane grating monochromator with the variable included angle mechanism. Its designed resolving power and photon flux are 3,000-10,000 and 10{sup 12}-10{sup 9} photons/s at 300 mA, respectively. The performance test results were generally satisfactory. An overview of the optical design of the beamline and the current status of commissioning are reported.

43 PARTICLE ACCELERATORS↗

Adaptation of UVSOR-Type Plane-Grating Monochromator in Saga

The plane grating monochromator (PGM) is one of the most useful monochromators in the world. The design concept of the PGM originates from the characteristics of synchrotron radiation itself, namely parallel rays and small source size. Since the performance of the PGM depends on the beam emittance of the storage ring, it is expected that even the used PGM may be utilized in recent facility. Therefore, the UVSOR-type PGM that had been used for more than twenty years in UVSOR was adapted to the university's branch beamline in Saga-LS with several modifications. The performance tests were carried out with a photoelectron spectrometer, and the observed values were compared with the ray-tracing calculation. The results show that the adaptation of the UVSOR-type PGM is good enough to study new functional materials.

43 PARTICLE ACCELERATORS↗

Identification of an advanced constitutive model of Magnesium alloy AZ31B

The main aim of this paper is to study the flow behavior of the AZ31B magnesium alloy by means of tensile tests performed in extended ranges of temperature and strain rates. The flow stress-strain curves analyzed by power law type constitutive equation can only fit well with experimental curves at the work-hardening stage. A new mathematical model is studied to describe the softening behavior of material based on tensile experiments. The relative parameters are obtained by fitting the equation with the experimental data. The genetic algorithm has been used to obtain the global optimal fitting parameters. The comparison between the fitted and experimental data proves the effectiveness of the model. The results indicate that this model leads to a better simulation of the flow stress during the softening stage than that of the power law equation. Based on this model, the deep drawing process has been simulated with the commercial finite element code FORGE registered. The punch load and thickness distribution of AZ31 sheet have been studied. The study of the results is helpful to the application of the stamping technology for the magnesium alloy sheet.

36 MATERIALS SCIENCE↗

Lithium pellet production (LiPP): A device for the production of small spheres of lithium

With lithium as a fusion material gaining popularity, a method for producing lithium pellets relatively quickly has been developed for NSTX. The Lithium Pellet Production device is based on an injector with a sub-millimeter diameter orifice and relies on a jet of liquid lithium breaking apart into small spheres via the Plateau-Rayleigh instability. A prototype device is presented in this paper and for a pressure difference of {Delta}P= 5 Torr, spheres with diameters between 0.91 < D < 1.37 mm have been produced with an average diameter of D= 1.14 mm, which agrees with the developed theory. Successive tests performed at Princeton Plasma Physics Laboratory with Wood's metal have confirmed the dependence of sphere diameter on pressure difference as predicted.

36 MATERIALS SCIENCE↗

A portable hydro-thermo-mechanical loading cell for in-situ small angle neutron scattering studies of proton exchange membranes

A portable hydro-thermo-mechanical loading cell has been designed to enable in-situ small angle neutron scattering (SANS) studies of proton exchange membranes (PEM) under immersed tensile loadings at different temperatures. The cell consists of three main parts as follows: a letter-paper-size motor-driven mechanical load frame, a SANS friendly reservoir that provides stable immersed and thermal sample conditions, and a data acquisition & control system. The ex-situ tensile tests of Nafion 212 membranes demonstrated a satisfactory thermo-mechanical testing performance of the cell for either dry or immersed conditions at elevated temperatures. The in-situ SANS tensile measurements on the Nafion 212 membranes immersed in D2O at 70oC proved the feasibility and capability of the cell for small angle scattering study on deformation behaviors of PEM and other polymer materials under hydro-thermo-mechanical loading.

hydro-thermo-mechanical.↗

Metallic beam developments for the SPIRAL 2 project

The SPIRAL 2 facility, currently under construction, will provide either stable or radioactive beams at high intensity. In addition to the high intensity of stable beams, high charge states must be produced by the ion source to fulfill the RFQ LINAC injection requirements: Q/A = 1/3 at 60 kV ion source extraction voltage. Excepting deuterons and hydrogen, most of the stable beam requests concern metallic elements. The existing 18 GHz electron cyclotron resonance ion source (ECRIS) Phoenix V2 designed at LPSC Grenoble has been used for the tests and will be the source for the SPIRAL 2 commissioning. The tests performed at LPSC for calcium ({sup 40}Ca{sup 14+} and {sup 40}Ca{sup 16+}), nickel ({sup 58}Ni{sup 19+}), and sulfur ({sup 32}S{sup 11+}) are described and discussed. Due to the very high charge states required, the oven method has been chosen. An intensity of 1 pμA has been reached for those elements. The performance and the beam stability have been studied using different buffer gases, and some ionization efficiency preliminary results are given.

43 PARTICLE ACCELERATORS↗

New experimental approaches to search for neutrino mass

In order to obtain high sensitivity in the study of the neutrino mass it is necessary to design experiments able to optimize all the sensitivity parameters. One of the most promising techniques to achieve this goal is the bolometric technique because of its intrinsic characteristics: high detection efficiency, excellent energy resolution, low intrinsic background and the possibility to study many different compounds. The bolometric technique has already obtained excellent results on the neutrino mass study with Cuoricino. The Cuoricino experiment has also shown that surface contaminations of materials facing the detectors would be the limiting factor for the sensitivity of next generation experiments with bolometers. Mainly for this reason scintillating bolometers have been developed allowing a very efficient discrimination of alpha particles thanks to their double readout. Tests performed on these crystals showed moreover the possibility to discriminate the interacting particles through a pulse shape analysis. This feature is very promising because it allows to reach the same results on the background reduction obtained with the hybrid detectors but without complicating the experimental assembly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design progress of cryogenic hydrogen system for China Spallation Neutron Source

China Spallation Neutron Source (CSNS) is a large proton accelerator research facility with 100 kW beam power. Construction started in October 2011 and is expected to last 6.5 years. The cryogenic hydrogen circulation is cooled by a helium refrigerator with cooling capacity of 2200 W at 20 K and provides supercritical hydrogen to neutron moderating system. Important progresses of CSNS cryogenic system were concluded as follows. Firstly, process design of cryogenic system has been completed including helium refrigerator, hydrogen loop, gas distribution, and safety interlock. Secondly, an accumulator prototype was designed to mitigate pressure fluctuation caused by dynamic heat load from neutron moderation. Performance test of the accumulator has been carried out at room and liquid nitrogen temperature. Results show the accumulator with welding bellows regulates hydrogen pressure well. Parameters of key equipment have been identified. The contract for the helium refrigerator has been signed. Mechanical design of the hydrogen cold box has been completed, and the hydrogen pump, ortho-para hydrogen convertor, helium-hydrogen heat exchanger, hydrogen heater, and cryogenic valves are in procurement. Finally, Hydrogen safety interlock has been finished as well, including the logic of gas distribution, vacuum, hydrogen leakage and ventilation. Generally, design and construction of CSNS cryogenic system is conducted as expected.

43 PARTICLE ACCELERATORS↗

Development of an alternating integrator for magnetic measurements for experimental advanced superconducting tokamak

A high-performance integrator is one of the key electronic devices for reliably controlling plasma in the experimental advanced superconducting tokamak for long pulse operation. We once designed an integrator system of real-time drift compensation, which has a low integration drift. However, it is not feasible for really continuous operations due to capacitive leakage error and nonlinearity error. To solve the above-mentioned problems, this paper presents a new alternating integrator. In the new integrator, the integrator system of real-time drift compensation is adopted as one integral cell while two such integral cells work alternately. To achieve the alternate function, a Field Programmable Gate Array built in the digitizer is utilized. The performance test shows that the developed integrator with the integration time constant of 20 ms has a low integration drift (<15 mV) for 1000 s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tuned range-separated hybrid functionals in the symmetry-adapted perturbation theory

The aim of this study is to present a performance test of optimally tuned long-range corrected (LRC) functionals applied to the symmetry-adapted perturbation theory (SAPT). In the present variant, the second-order energy components are evaluated at the coupled level of theory. We demonstrate that the generalized Kohn-Sham (GKS) description of monomers with optimally tuned LRC functionals may be essential for the quality of SAPT interaction energy components. This is connected to the minimization of a many-electron self-interaction error and exemplified by two model systems: polyacetylenes of increasing length and stretching of He{sub 3}{sup +}. Next we provide a comparison of SAPT approaches based on Kohn-Sham and GKS description of the monomers. We show that LRC leads to results better or comparable with the hitherto prevailing asymptotically corrected functionals. Finally, we discuss the advantages and possible limitations of SAPT based on LRC functionals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Kingdon ion trap system for trapping externally injected highly charged ions

We have developed a Kingdon ion trap system for the purpose of the laboratory observation of the x-ray forbidden transitions of highly charged ions (HCIs). Externally injected Ar{sup q+} (q = 5–7) with kinetic energies of 6q keV were successfully trapped in the ion trap. The energy distribution of trapped ions is discussed in detail on the basis of numerical simulations. The combination of the Kingdon ion trap and the time-of-flight mass spectrometer enabled us to measure precise trapping lifetimes of HCIs. As a performance test of the instrument, we measured trapping lifetimes of Ar{sup q+} (q = 5–7) under a constant number density of H₂ and determined the charge-transfer cross sections of Ar{sup q+}(q = 5, 6)-H₂ collision systems at binary collision energies of a few eV. It was confirmed that the present cross section data are consistent with previous data and the values estimated by some scaling formula.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A zero dead-time multi-particle time and position sensitive detector based on correlation between brightness and amplitude

A new multi-particle time and position sensitive detector using only a set of microchannel plates, a waveform digitizer, a phosphor screen, and a CMOS camera is described. The assignment of the timing information, as taken from the microchannel plates by fast digitizing, to the positions, as recorded by the camera, is based on the COrrelation between the BRightness of the phosphor screen spots, defined as their integrated intensity and the Amplitude of the electrical signals (COBRA). Tests performed by observing the dissociation of HeH, the fragmentation of H{sub 3} into two or three fragments, and the photo-double-ionization of Xenon atoms are presented, which illustrate the performances of the COBRA detection scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-isothermal furnace for in situ and real time X-ray radiography solidification experiments

In this paper, we present a newly developed near-isothermal X-ray transparent furnace for in situ imaging of solidification processes in thin metallic samples. We show that the furnace is ideally suited to study equiaxed microstructure evolution and grain interaction. To observe the growth dynamics of equiaxed dendritic structures, a minimal temperature gradient across the sample is required. A uniform thermal profile inside a circular sample is achieved by positioning the sample in the center of a cylindrical furnace body surrounded by a circular heater arrangement. Performance tests with the hypo-eutectic Al-15wt.%Cu and the near-eutectic Al-33wt.%Cu alloys validate the near-isothermal character of the sample environment. Controlled cooling rates of less than 0.5 K min{sup −1} up to 10 K min{sup −1} can be achieved in a temperature range of 720 K–1220 K. Integrated in our rotatable laboratory X-ray facility, X-RISE, the furnace provides a large field of view of 10.5 mm in diameter and a high spatial resolution of ∼4 μm. With the here presented furnace, equiaxed dendrite growth models can be rigorously tested against experiments on metal alloys by, e.g., enabling dendrite growth velocities to be determined as a function of undercooling or solutal fields in front of the growing dendrite to be measured.

36 MATERIALS SCIENCE↗

Crash simulation of UNS electric vehicle under frontal front impact

Sebelas Maret University has been developing an Electric Vehicle namely SmarT-EV UNS. The main structure of the car are chasis and body. The chasis is made from steel and the body is made from fiberglass composite. To ensure the safety of the car, both static and dynamic tests were carried out to these structures, including their materials, like: tensile test, bending test, and impact test. Another test needed by this vehicle is crashworthiness test. To perform the test, it is needed complex equipments and it is quite expensive. Another way to obtain vehicle crashworthiness behaviour is by simulate it. The purpose of this study was to simulate the response of the Smart-EV UNS electric vehicle main structure when crashing rigid barrier from the front. The crash simulation was done in according to the NHTSA (National Highway Traffic Safety Administration) within the speed of the vehicle of 35 mph. The UNS Electric Vehicle was modelled using SolidWorks software, and the simulation process was done by finite element method using ANSYS software. The simulation result showed that the most internal impact energy was absorbed by chassis part. It absorbed 76.2% of impact energy, then the base absorbed 11.3 %, while the front body absorbed 2.5 %, and the rest was absorbed by fender, hood, and other parts.

42 ENGINEERING↗

PLA recycling by hydrolysis at high temperature

In this work the process of PLA hydrolysis at high temperature was studied, in order to evaluate the possibility of chemical recycling of this polymer bio-based. In particular, the possibility to obtain the monomer of lactic acid from PLA degradation was investigated. The results of some preliminary tests, performed in a laboratory batch reactor at high temperature, are presented: the experimental results show that the complete degradation of PLA can be obtained in relatively low reaction times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A divertor scraper observation system for the Wendelstein 7-X stellarator

Two graphite divertor elements called scrapers have been installed on the Wendelstein 7-X stellarator in the throat of the magnetic island divertor. To diagnose one, we have designed, built, calibrated, and installed a new infrared/visible imaging endoscope system to enable detailed observations of the plasma interactions and heat loads at one of the scrapers and the nearby divertor surfaces. The new system uses a shuttered pinhole-protected pair of 90° off-axis 228 mm focal length aluminum parabolic mirrors, and two flat turning metal mirrors, to send light to a sapphire vacuum window 1.6 meters away, beyond which we have co-located telephoto lens-based infrared and visible cameras. The back-to-back off-axis parabolas serve to cancel out most aberrations, enabling the use of off-the-shelf commercial optics outside of the vessel. For the infrared, we use a 3-5 μm 1-megapixel FLIR SC8303HD camera and for the visible, a 5-megapixel CMOS PCO 5.5 edge camera. A short 1-m quartz pickoff fiber is used to send 200-1100 nm light to a compact spectrometer, also located in the same iron shield box as the cameras. The camera field of view covers the 700 mm length of the scraper, and includes locations monitored by thermocouples and Langmuir probes embedded in some of the scraper tiles. Predicted and actual optical test performances of the overall system are then compared.

47 OTHER INSTRUMENTATION↗

Development of a multi-channel capacitive probe for electric field measurements with fine spatial and high time resolution

A capacitive probe is one of a few diagnostics that is directly sensitive to the plasma potential. Using this diagnostic technique, a Multi-channel Linear Capacitive Probe (MLCP) is developed herein for turbulence measurements. The MLCP has 10 spatial channels and provides 9 points of radial electric field measurements simultaneously with a spatial step of 7 mm. A new readout circuit and a correction technique for low frequency attenuation are also developed to achieve the required spatial and time resolution. A performance test of the MLCP using a reversed field pinch plasma confirms that the MLCP resolves sub-centimeter structures of the equilibrium radial electric field profile and fluctuations up to 680 kHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of a Talbot–Lau x-ray deflectometer diagnostic platform for the OMEGA EP laser

A Talbot–Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 22 cm -3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30–100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. Finally, the necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

36 MATERIALS SCIENCE↗