Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Search for long-lived particles decaying to e± μ∓ ν

Long-lived particles decaying to e±μ∓ν, with masses between 7 and 50GeV/c 2 and lifetimes between 2 and 50 ps, are searched for by looking at displaced vertices containing electrons and muons of opposite charges. The search is performed using 5.4 fb -1 of p p collisions collected with the LHCb detector at a centre-of-mass energy of $\sqrt{s}$=13TeV. Three mechanisms of production of long-lived particles are considered: the direct pair production from quark interactions, the pair production from the decay of a Standard-Model-like Higgs boson with a mass of 125GeV/c 2 , and the charged current production from an on-shell W boson with an additional lepton. No evidence of these long-lived states is obtained and upper limits on the production cross-section times branching fraction are set on the different production modes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for massive long-lived particles decaying semileptonically at ${\sqrt{s}}=13\,\hbox {TeV}$

A search is performed for massive long-lived particles (LLPs) decaying semileptonically into a muon and two quarks. Two kinds of LLP production processes were considered. In the first, a Higgs-like boson with mass from 30 to 200\,GeV\!/c 2 is produced by gluon fusion and decays into two LLPs. The analysis covers LLP mass values from 10\,GeV\!/c 2 up to about one half the Higgs-like boson mass. The second LLP production mode is directly from quark interactions, with LLP masses from 10 to 90\,GeV\!/c 2 . The LLP lifetimes considered range from 5 to 200 ps. This study uses LHCb data collected from proton-proton collisions at $\sqrt{s}$=13\,TeV, corresponding to an integrated luminosity of 5.4\,fb -1 . No evidence of these long-lived states has been observed, and upper limits on the production cross-section times branching ratio have been set for each model considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrolyte Takeover Strategy for Performance Recovery in Polysulfide-Permanganate Flow Batteries

The abundance of active material precursors for a polysulfide-permanganate flow battery makes it a compelling chemistry for large-scale, and potentially long-duration (>10 h), grid electricity storage. Precipitation, arising from either reactant crossover or electrolyte side reactions, decrease cell efficiencies during charge/discharge cycling. Regardless of the abundance and low cost of active materials, a system without high cyclability cannot meet grid electricity storage economic targets for applications that cycle regularly. Precipitated species can be removed, and reactor efficiency performance restored, by using an electrolyte takeover process, or ETP. Two ETP methods are investigated. One ETP uses the negative electrolyte, an alkaline polysulfide (pS) solution, as takeover solution, and another uses dilute acidic peroxide (DAP) as the takeover solution. Both ETPs maintain functional cell operation within an acceptable performance range over >1000 h and >200 cycles, a duration over which cells that do not undergo ETPs clog and fail. The DAP ETP proves especially effective and limits irrecoverable voltage efficiency fade below 0.02%/cycle. These ETPs, either individually, or in combination, can enable the requisite cyclability for practical polysulfide-permanganate flow battery systems.

25 ENERGY STORAGE↗

Limiting Current Density in Single-Ion-Conducting and Conventional Block Copolymer Electrolytes

The limiting current density of a conventional polymer electrolyte (PS-PEO/LiTFSI) and a single-ion-conducting polymer electrolyte (PSLiTFSI-PEO) was measured using a new approach based on the fitted slopes of the potential obtained from lithium-polymer-lithium symmetric cells at a constant current density. The results of this method were consistent with those of an alternative framework for identifying the limiting current density taken from the literature. We found the limiting current density of the conventional electrolyte is inversely proportional to electrolyte thickness as expected from theory. The limiting current density of the single-ion-conducting electrolyte was found to be independent of thickness. There are no theories that address the dependence of the limiting current density on thickness for single-ion-conducting electrolytes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Benchmarking Solid-State Batteries Containing Sulfide Separators: Effects of Electrode Composition and Stack Pressure

Integrating sulfide separators into solid-state batteries (SSBs) containing high energy cathodes typically requires one or more materials and engineering solutions including: (i) applying interfacial coatings to mitigate electrolyte decomposition, (ii) applying high stack pressures to form robust solid-solid contacts, and (iii) using alloying anodes to avoid Li dendrite formation. Despite the promise of these approaches, a lack of standardized testing protocols makes it difficult to directly compare results among different studies. To address this problem, the present work benchmarks the performance of SSBs containing β-Li 3 PS 4 (LPS) separators and composite cathodes. By systematically varying the anode/cathode composition and stack pressure, this work demonstrates that cathode design is a major bottleneck for solid-state cells cycled at low rates (<100 µA cm -2 ). Operando stack pressure measurements show that, while mechanical confinement generally promotes higher active material utilization and cycling stability, this strategy alone does not address interfacial reactivity between LPS and high voltage cathodes. Here, these results also demonstrate that stress evolution during cycling is dominated by volume changes at the Li metal anode. Finally, we show that FeS 2 cathodes with moderate operating voltages (<3 V vs Li/Li + ) exhibit superior cycling performance compared to high voltage cathodes by facilitating formation of stable cathode/electrolyte interfaces.

25 ENERGY STORAGE↗

Adverse Effects of Trace Non-polar Binder on Ion Transport in Free-standing Sulfide Solid Electrolyte Separators

Sulfide solid-state electrolyte (SE) possesses high room-temperature ionic conductivity. However, fabrication of the free-standing, sheet-type thin sulfide SE film electrolyte to enable all-solid-state batteries to deliver high energy and power density remains challenging. Herein we show that argyrodite sulfide (Li 6 PS 5 Cl) SE can be slurry cast to form free-standing films with low (≤5 wt%) loadings of poly(isobutylene) (PIB) binder. Two factors contribute to a lower areal specific resistance (ASR) of the thin film SEs benchmarked to the pristine powder pellet SSE counterparts: i) 1–2 orders reduced thickness and ii) reasonably comparable ionic conductivity at room temperature after the isostatic pressing process. Nevertheless, an increasing polymer binder loading inevitably introduced voids in the thin film SEs, compromising anode/electrolyte interfacial ion transport. Our findings highlight that electrolyte/electrode interfacial stability, as well as the selection of slurry components, including sulfide SE, binder, and solvent, play essential roles in thin film sulfide electrolyte development.

25 ENERGY STORAGE↗

Energy Exascale Earth System Model v2.0.1

First patch release of v2.0.0 Changes since v2.0.0 [Important change] Fix ocean threading bug seen in debug cases on Chrysalis with Intel 20.0.4. Was introduced around time of v2.0.0 tag. Does not change v2.0.0 answers on Chrysalis because those didn't use threading or debugging. [EAM] Add semi-lagrangian tracer transport for theta-l (F90 and C++), add new algorithm for finding tropopause, add DSCREAM to allow v2 and SCREAM settings in same code such as adjust_ps [EAM-MMF] 60L default, allow C++ back end of RRTMGP (EAM too). [EAMxx] add nu-top functionality, fix forcing functor, add ttype9 and dcmip2012 tests 2.1, 2.2, and 3 HOMME: remove obsolete remap algs, option to specify dynamics alg indep of tracer, new sponge layer, add imex tests [ELM] Add topography-based subgrid (topounits), add FATES-ELM Nitro., Phos. and CH4 coupling, add land-use ts for NARRM, add lulc for SSP3 RCP7, Fix nutrient fertilization exp test and carbon isotope flux, Fix xactive lnd dry deposition, add lake water storage option, fix plant hydraulics 2d params, fix carbon budget calc, fix soil nutrient conc. bug, fix mosart dam bug, add test for new ELM, MOSART features, fix bug in O3 dry dep stomatal resistances, fix plant hydraulics restart BFB error, update mkmapdata. [MOSART] fix bug for reading the latitude from an unstructured input file, fix oversat in bubble test. [MPAS-ocean] Add CFC11, CFC12 tracers, add 2D spherical transport tests, fix del4 tracer mixing, add MARBL ocean tracer mixing, modify harmonic analysis options, add GPU port of vmix routines, fix calc of ML-averaged BV freq. [MPAS-seaice] Change extents of initial polar disks for oRRS18to6v3 grid, fix ice BGC with MARBL, update spherical test cases, fix DON coupling, Remove Cf from sea ice constants. [MPAS-landice] add CRYO1850-4xCO2 compset [CIME] add GCP, ANL GCE, Spock, Perlmutter, deprecate config_compilers.xml, fix and clean-up cmake macros, fix slurm bindings, refactor CIME internal testing, cleanup SCORPIO perf data, allow position independent compset naming, [also] update v2 benchmarking suite, extend e3sm_prod with throughput and memory checks

E3SM Project, DOE↗

Synergistic effects of Al, Ga, and In doping on ZnO nanorod arrays grown via citrate-assisted hydrothermal technique for highly efficient and fast scintillator screens

To be used as efficient alpha particle scintillator in the fields of nuclear security, nuclear nonproliferation and high-energy physics, scintillator screens must have high light output and fast decay properties. While there has been a great deal of progress in scintillation efficiency, achieving fast decay time properties are still a challenge. In this work, the near band edge (NBE) UV luminescence and alpha particle induced scintillation properties of vertically aligned densely packed ZnO nanorods (NRs) doped with Al, Ga, and In have been thoroughly investigated. The high crystalline hexagonal wurtzite structure with a strong orientation through the c -axis plane (002) and aspect ratios in the range 13–22 have been observed for all ZnO NRs. Electron paramagnetic resonance (EPR) analysis exhibited paramagnetic signals at g ≈ 1.96 for all ZnO NRs. A cost effective green hydrothermal synthesis technique was employed to grow well-aligned NRs. Using citrate as an additive acting as a strong reducing agent in the solution during the crystal growth, defects on the surface are significantly suppressed, thereby enhancing the NBE UV emission. Significantly higher NBE UV emission was observed from the top surface of ZnO NRs in cathodoluminescence (CL) microscopy. Results show that citrate assisted donor doping of ZnO NRs not only reduces the defect emission and NBE self-absorption, but also induces fast decay time (~ 600–700 ps), which makes ZnO NRs a good candidate for fast alpha particle scintillator screens used in associated particle imaging for time and direction tagging of individual neutrons generated in D–T and D–D neutron generators.

36 MATERIALS SCIENCE↗

Spatio-temporal focal spot characterization and modeling of the NIF ARC kilojoule picosecond laser

The advanced radiographic capability (ARC) laser system, part of theNational Ignition Facility (NIF) at Lawrence Livermore National Laboratory, is a short-pulse laser capability integrated into the NIF. The ARC is designed to provide adjustable pulse lengths of ~1–38 ps in four independent beamlets, each with energies up to 1 kJ (depending on pulse duration). A detailed model of the ARC lasers has been developed that predicts the time- and space-resolved focal spots on target for each shot. Measurements made to characterize static and dynamic wavefront characteristics of the ARC are important inputs to the code. Modeling has been validated with measurements of the time-integrated focal spot at the target chamber center (TCC) at low power, and the space-integrated pulse duration at high power, using currently available diagnostics. In this work, these simulations indicate that each of the four ARC beamlets achieves a peak intensity on target of up to a few 10 18 W=cm 2 .

47 OTHER INSTRUMENTATION↗

Optimizing hybrid rotational femtosecond/picosecond coherent anti-Stokes Raman spectroscopy in nitrogen at high pressures and temperatures

We demonstrate the use of hybrid rotational femtosecond/picosecond (fs/ps) coherent anti-Stokes Raman spectroscopy (HR-CARS) as a technique for temperature measurements in nitrogen gas at high pressures and temperatures. A broadband pulse shaper-adjusted 42 fs pulse interacts with a narrow-bandwidth, frequency-upconverted 5.5 ps pulse in a cell containing N 2 at pressures of 1–70 atm and temperatures of 300–1000 K. A computational code is used to model spectra and fit experimental results to obtain best-fit temperatures. We demonstrate good qualitative fits as well as good accuracy and precision between thermocouple measured and best-fit temperatures over the explored pressure and temperature regimes. The overall average percentage temperature difference between thermocouple measurements and best-fit temperatures is − <#comment/> 0 . 3 % <#comment/> with a standard deviation of 7.1%, showing the suitability of HR-CARS for characterizing high-pressure and -temperature environments.

Torge Mecker, Nils (ORCID:0000000238977170)↗

Spatially-resolved measurements of spin valley polarization in MOCVD-grown monolayer WSe 2

Time-resolved Kerr rotation microscopy is used to generate and measure spin valley polarization in MOCVD-grown monolayer tungsten diselenide (WSe 2 ). The Kerr signal reveals bi-exponential decay with time constants of 100 ps and 3 ns. Measurements are performed on several triangular flakes from the same growth cycle and reveal larger spin valley polarization near the edges of the flakes. This spatial dependence is observed across multiple WSe 2 flakes in the Kerr rotation measurements but not in the spatially resolved reflectivity or microphotoluminescence data. Time-resolved pump-probe overlap measurements further reveal that the Kerr signal’s spatial dependence is not due to spin diffusion on the nanosecond timescale.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Post-compression of long-wave infrared 2 picosecond sub-terawatt pulses in bulk materials

We have experimentally demonstrated the post-compression of a long-wave infrared (9.2 μm) 150 GW peak power pulse from 2 ps to less than 500 fs using a sequence of two bulk materials with negative group velocity dispersion (GVD). The compression resulted in up to 1.6-fold increase of the peak power and up to 2.8-fold increase of the intensity in the center of a quasi-Gaussian beam. The partial decoupling of the self-phase modulation and chirp compensation stages by using two materials with significantly different ratios of nonlinear refractive index to GVD provides accurate optimization of the compression mechanism and promises a viable path to scaling peak powers to supra-terawatt levels. During the preparatory study, we measured, for the first time to our knowledge, the nonlinear refractive indices of NaCl, KCl, and BaF 2 for picosecond pulses in the long-wave infrared region.

43 PARTICLE ACCELERATORS↗

Simultaneous contrast improvement and temporal compression using divided-pulse nonlinear compression

We experimentally demonstrate how divided-pulse nonlinear compression can be used to improve the temporal contrast of a laser pulse train while simultaneously temporally compressing the pulses. We measure a contrast improvement of almost four orders of magnitude on a nanosecond time scale and temporally compress the pulses from 1.2 ps to 187 fs. The efficiency of our method is also competitive with other contrast improvement methods, with 72% efficiency measured for the main pulse. We expect the method will be useful in the continuing development of high-power, Yb regenerative amplifiers, which suffer from both significant prepulses and relatively long pulse durations.

47 OTHER INSTRUMENTATION↗

Fluorescence lifetime measurements using photon pair correlations generated via spontaneous parametric down conversion (SPDC)

We have used photon pair correlations generated via spontaneous parametric downconversion (SPDC) to measure the fluorescence lifetime of the organic dye rhodamine 6 G, demonstrating that fluorescence lifetime measurements can be achieved using a continuous wave (CW) laser, without pulsed or modulated lasers. Our entangled photon method, quantum fluorescence lifetime (Q-FL) measurements, uses one photon to excite fluorescence and the resulting fluorescence photon is timed and referenced to the arrival time of the other entangled photon. Thus, we can exploit the short timescale of photon pair correlations to conduct experiments that are typically carried out with pulsed lasers and we show that the inherent timing of the photons is fast enough to resolve the nanosecond scale fluorescence lifetime of the sample. This measurement paves the way towards using the time correlations of entangled photons for fluorescence imaging; capitalizing on the presence of fast, sub-100 ps correlations that have not been demonstrated classically.

Eshun, Audrey (ORCID:0000000167697082)↗

Hyperspectral acquisition with ScanImage at the single pixel level: application to time domain coherent Raman imaging

We present a comprehensive strategy and its practical implementation using the commercial ScanImage software platform to perform hyperspectral point scanning microscopy when a fast time-dependent signal varies at each pixel level. In the proposed acquisition scheme, the scan along the X-axis is slowed down while the data acquisition is maintained at a high pace to enable the rapid acquisition of the time-dependent signal at each pixel level. The ScanImage generated raw 2D images have a very asymmetric aspect ratio between X and Y, the X axis encoding both for space and time acquisition. The results are X-axis macro-pixel where the associated time-dependent signal is sampled to provide hyperspectral information. We exemplified the proposed hyperspectral scheme in the context of time-domain coherent Raman imaging, where a pump pulse impulsively excites molecular vibrations that are subsequently probed by a time-delayed probe pulse. In this case, the time-dependent signal is a fast acousto-optics delay line that can scan a delay of 4.5ps in 25 μ s at each pixel level. With this acquisition scheme, we demonstrate ultra-fast hyperspectral vibrational imaging in the low frequency range [10 cm −1 , 150 cm −1 ] over a 500 μm field of view (64 x 64 pixels) in 130ms (∼ 7.5 frames/s). The proposed acquisition scheme can be readily extended to other applications requiring the acquisition of a fast-evolving signal at each pixel level.

Metais, Samuel↗

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectral broadening and compression of picosecond pulses in air using a multi-pass cell

We report the spectral broadening and post-compression of picosecond pulses using a multi-pass cell (MPC) operating in air. A 2 m-long bi-concave cavity with 41 reflections and 96.4% transmission was designed and implemented, optimized for the compression of 5.5 ps, 4.5 mJ pulses from a Yb:YAG laser operating at 1030 nm. A 19.3-fold spectral broadening was obtained, increasing the bandwidth from 0.3 nm to 5.8 nm, which enabled pulse compression down to 547 fs with a symmetric temporal profile close to the transform limit. These results demonstrate the feasibility of using open-air MPCs for high-energy picosecond pulse post-compression, without the need for sealed chambers, while preserving high mode quality and transmission. Scaling to pulse higher energy is discussed.

Zaldivar Escola, F. [Univ. of Buenos Aires (Argent↗