Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Nuclear science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Livermore tomography tools: Accurate, fast, and flexible software for tomographic science

Livermore Tomography Tools (LTT) is a customizable scientific software package that enables a broad range of research and development efforts into computed tomography (CT). Here, it was developed to process x-ray and neutron CT data accurately and rapidly from raw detector counts to reconstructed volumes with the flexibility to handle many special cases. LTT fulfills long-term CT software goals to provide quantitatively accurate results reported in physical units (e.g., mm -1 or cm -1 ) while exploiting all available computational advantages to maximize speed. Written in C/C++ with support for multiple CPUs and GPUs, LTT runs on many computing platforms (Linux/Unix, Windows, and Mac; laptops to supercomputers). As a result, LTT can:process data acquired from various custom-built and commercially available CT scanners, model and simulate x-ray and neutron interactions to encourage algorithm prototyping, and allow for rapid insertion of the latest algorithms.We describe LTT’s software architecture, user interfaces, and its 88 algorithms (as of this writing) for pre-processing, reconstruction, post-processing, and simulation that support many scanner geometries (parallel-, fan-, cone-beam, and custom). Several applications are presented that illustrate LTT’s accuracy, speed, and flexibility relative to other solutions.

36 MATERIALS SCIENCE↗

Validation of the two-region Rossi-alpha model for reflected assemblies

Nuclear criticality safety, nonproliferation and safeguards, emergency response, and stockpile stewardship utilize estimates of the k eff multiplication factor. The value of k eff cannot be directly measured, but it can be inferred from the prompt neutron period. One modality of measuring the prompt neutron period is the Rossi-alpha method, which is predicated on fitting a histogram of detection time differences due to the nonrandom temporal distribution of same-fission-chain neutrons. Recent works have developed the motivation and theory to expand traditional one-region point kinetic models resulting in one-exponential histogram fits to two-region models that result in two-exponential fits. This paper validates the new two-region model using organic scintillator measurements of copper-reflected weapons-grade plutonium (0:83 ≤ k eff ≤ 0:94) and high-density- polyethylene-reflected highly enriched uranium (0:73 ≤ k eff ≤ 0:95). Furthermore, the results show that more thermal systems have shorter prompt neutron periods in the core region due to increased induced-fission probabilities for moderated neutrons. Here, a new parameter introduced by the two- region model is also shown to be correlated to the amount of reflection, and may be used to infer assembly properties such as type and amount of reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a rapid-transit system for precision nuclear physics measurements

A Rapid Belt-driven Irradiated Target Transfer System, named RABITTS, was developed for use at the Triangle Universities Nuclear Laboratory. This system allows for cyclic activation with neutron or photon beams, and measurement of reaction products using γ-ray spectroscopy. Both a 1 meter and 10 meter transfer system have been developed with transit times as low as 0.4 and 1.0 seconds, respectively. The systems are deployed at the tandem accelerator laboratory for use with monoenergetic neutron beams, and at the High-Intensity γ-ray Source facility for activation using photon beams. A detailed characterization of the systems’ performance and sensitivity is presented. In order to produce the highest accuracy cross-section data, a model for calculating corrections to cyclic activation with variable beam flux is developed and presented. We have commissioned these systems by measuring 197m Au, where we report a measured half-life of 7.73 ± 0.05 s and a 197 Au(n, n') 197m Au isomer production cross of 628 ± 28 mb at neutron energy E n = 2.0 MeV. In addition, we measured 90m Zr, where we report a measured half-life of 799.7 ± 8.0 ms and a 90 Zr(n, n') 90m Zr isomer production cross of 180 ± 12 mb at E n = 4.6 MeV. Furthermore, these measured half-lives are in excellent agreement with the evaluated values and the cross-section measurements are performed at previously unmeasured incident neutron energies.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Semi-empirical simulation of in-motion radiation detection systems

The Replicative Assessment of Spectroscopic Equipment (RASE) is an open-source software that uses experimental data as the basis to simulate the response of commercial radiation detectors to sources in various situations, particularly in the context of nuclear security and safeguards applications. Dynamic RASE introduces the capability to simulate scenarios where sources and detector are in relative motion. Position-dependent experimentally acquired gamma spectra are ingested by Dynamic RASE to build maps that describe the detector response over all space. These response maps are used to replicate the time-dependent energy spectra collected as sources move on a path near the detector. Here, a Gaussian process is used to build each map, incorporating a novel kernel adapted to the special case of radiation detection. The approach has been validated against experimental data acquired using a NaI-based detector for 137 Cs and 54 Mn sources. The capability to create accurate simulations using either long-dwell static measurements or dynamic pass-by measurements as source data has been demonstrated. Quantitative relative performance, benefits, and shortcomings are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of target lifetime for production of 14 MeV neutrons

Two methods are examined for extending the life of tritium targets for production of 14 MeV neutrons by the 3 H( 2 H,n) 4 He nuclear reaction. With thick film targets the neutron production rate decreases with time due to isotope exchange of tritium in the film with implanted deuterium. Here, the target life is maximized by operating the target at elevated temperature where the implanted deuterium mixes by thermal diffusion throughout the entire thickness of the film. The number of neutrons obtained from a target is then proportional to the initial tritium content of the film. A novel thin-film target design was also developed and tested. With these thin-film targets, the incident deuterium is implanted through the tritide into the underlying substrate material. A thin permeation barrier layer between the tritide film and substrate, reduces the rate of tritium loss from the tritide film. Good thin-film target performance was achieved using W and Fe for the barrier and substrate materials respectively. Thin-film targets were fabricated and tested and shown to produce similar number of neutrons as thick-film targets while using only a small fraction of the amount of tritium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent Advances in Nuclear Forensic Chemistry

Nuclear forensics is a rapidly growing field with a widespread impact on global nonproliferation. From the beginning, nuclear forensic capabilities have been inextricably bound to existing limitations within chemistry and materials science. As nuclear forensics has continued to develop as a unique field of research, new advances in chemistry have revolutionized our ability to rapidly and quantitatively analyze radioactive materials for attribution. In particular, microanalytical techniques originally developed for nanoscience, such as micro-XRF, SIMS, and SEM-EDX, have enabled spatially resolved chemical analyses to be performed with only nanograms of material. Such techniques have redefined the paradigm for pre- and postdetonation nuclear forensics, as large quantities of material are no longer necessary for full characterization and attribution. This Review explains how modern nuclear forensic techniques have developed from their origins in chemistry and provides real-world examples of how these techniques have been used to characterize radioactive materials, including fallout from nuclear detonations such as the 1945 Trinity test.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Device response principles and the impact on energy resolution of epitaxial quantum dot scintillators with monolithic photodetector integration

Abstract Epitaxial quantum dot (QD) scintillator crystals with picosecond-scale timing and high light yield have been created for medical imaging, high energy physics and national security applications. Monolithic photodetector (PD) integration enables the sensing of photons generated within the waveguiding crystal and allows a wide range of scintillator-photodetector coupling geometries. Until recently, these doubly novel devices have suffered from complex, high variance responses to monoenergetic sources which significantly reduces their precision and accuracy. The principles governing the overall device response have now been discerned and embodied by an expression derived within a geometrical optics framework which considers optical properties, surface roughness and photodetector coupling geometry. Response variation due to these factors was sufficiently reduced to obtain material-related energy resolution values of 2.4% with alpha particles. These findings place energy resolution alongside luminescence timescale, photon yield, and radiation hardness as outstanding properties of these engineered materials.

36 MATERIALS SCIENCE↗

A novel integrated time-resolved array avalanche photodiode detection system for nuclear resonant scattering measurements

Here, the nuclear resonant scattering (NRS) experiment requires photon-counting detectors with high time resolution, short dead time, large dynamic range, low noise, and large detection area. An 8-channel avalanche photodiode (APD) array detector system with high integrity, flexibility, and reliability has been developed to adapt to the demands of NRS experiments. The detector system mainly consists of four key parts: (i) an array-APD sensor, (ii) 8-channel integrated fast preamplifiers, (iii) the time-to-digital converter readout electronics, and (iv) a data acquisition system and EPICS support software. Remarkably, the system exhibits a time resolution of better than 500 ps and has a sufficiently low noise level, allowing for the lowest detection energy threshold of 4 keV. The performance of the new array-APD system as well as its real application in nuclear forward scattering (NFS) and nuclear resonant inelastic x-ray scattering (NRIXS) experiments was tested in two synchrotron facilities. With the new system, the NFS signal very close to the prompt electronic scattering signal can be extracted. Thanks to the customized EPICS-areaDetector-based control software, NRIXS spectra can be readily measured with time and energy information of the NRIXS signal stored in the raw data, which is promising for developing NRIXS data analysis in the time domain. The array-APD detector can be deployed for nuclear resonant scattering experiments at various synchrotron radiation facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency comb generation in WGM microsphere based generators for telecommunication applications

We review the frequency comb generation process, main microresonator parameters such as free spectral range (FSR) and Q-factor, previously used optical frequency comb (OFC) generator parameters and resulting frequency combs, as well as the implementation of OFC for optical data transmission. An optical frequency comb is produced in a setup based on a tapered fibre and a SiO{sub 2} microsphere. The generated frequency comb has a frequency spacing of 2 nm or 257 GHz. During the fabrication of a tapered fibre from SMF28, use is made of the transmission signal to control the taper pulling process. The final measured tapered fibre transmission is ∼96%. A microsphere whispering gallery-mode resonator (WGMR), exhibiting a Q-factor of at least 2 × 10{sup 7}, is fabricated from an optical fibre with a thicker core than SSMF. Moreover, for future experiments, a frequency comb generator based on a free-space setup consisting of lenses, a prism, and a microsphere is developed, and the Q-factor dependence on different distances between the prism and the microsphere is investigated. (optical components of fibre-optic communication lines)

36 MATERIALS SCIENCE↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of 7.2× 6.1× 7.0 m3. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV/c to 7 GeV/c. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, dE/dx calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

ADC Nonlinearity Correction for the Majorana Demonstrator

Imperfections in analog-to-digital conversion cannot be ignored when signal digitization requirements demand both wide dynamic range and high resolution, as is the case for the MAJORANA DEMONSTRATOR 76 Ge neutrinoless double beta decay search. Enabling the experiment's high-resolution spectral analysis and efficient pulse shape discrimination required careful measurement and correction of ADC nonlinearites. Here, a simple measurement protocol was developed that did not require sophisticated equipment or lengthy data taking campaigns. A slope-dependent hysteresis was observed and characterized. A correction applied to digitized waveforms prior to signal processing reduced the differential and integral nonlinearites by an order of magnitude, eliminating these as dominant contributions to the systematic energy uncertainty at the double-beta decay Q value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Suppression of Penning discharges between the KATRIN spectrometers

Abstract The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)-neutrino mass with a sensitivity of 0.2eV/c $$^2$$ 2 by precisely measuring the endpoint region of the tritium $$\beta $$ β -decay spectrum. It uses a tandem of electrostatic spectrometers working as magnetic adiabatic collimation combined with an electrostatic (MAC-E) filters. In the space between the pre-spectrometer and the main spectrometer, creating a Penning trap is unavoidable when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, “electron catchers” were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomaly Detection and Identification Using a Leave-One-Variable-Out Method

At nuclear power plants (NPPs), anomaly detection and identification (i.e., determining the causes of anomalies) are important tasks for ensuring the safe and efficient operation of NPPs. These tasks are currently labor-intensive and costly, and are made more difficult by the size and complexity of NPP systems. An alternative approach to conducting these tasks is to automate them, such as via the reconstruction-based contribution method, which is a well-researched unsupervised machine learning method that uses a data-driven model of anomaly-free behavior to detect events and then identify each variable’s contributions to those events. The present effort developed a novel contribution approach that utilized a leave-one-variable-out (LOVO) model, with which each variable is predicted using all the other variables. The novelty lay in transforming this model into a reconstruction model and modifying the identification algorithm to work with the new reconstruction model. To evaluate this method in a controlled environment, a synthetic dataset based on spring-mass-damper (SMD) systems (commonly found in mechanical engineering references) was used, with known anomalies introduced into the system. The proposed method successfully detected the anomalies and afforded insights into their causes, thus enabling the appropriate identifications to be made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Further Support of the Development of Advanced Multilayer Optics Coatings for X-Ray Imaging

SAO is working with LLNL to develop Wolter-I optics for x-ray imaging applications at energies of 15-50 keV and above at NNSA facilities. Our work includes R&D on advanced multilayer coatings as well as fabrication and testing of Wolter-I multilayer coated optics. It also includes delivery of custom 3.05-meter focal length Wolter optics with response at energies of interest to Sandia National Laboratories and LLNL. The mandrels for the custom optics are fabricated at MSFC. In previous contracts, SAO delivered several optics to LLNL with response at various energies. During this present contract period two tasks were carried out. Task1: the coating, replication and characterization of a custom optic with peak response at 22.8 keV, using the custom-designed SANZ mandrels. Task2: carrying out modifications to the coating chamber at SAO to accommodate new, longer, custom-designed mandrels (SANZlong) that will be fabricated at NASA MSFC in FY2020. The longer mandrels are necessary to mitigate end effects observed in the replication process for the small optics currently being fabricated.

36 MATERIALS SCIENCE↗

Microstructural Effects of PETN on Detonator Performance

The strategic motivation of the project is guided by the Need to understand: material characteristics important to performance; how to most appropriately measure/monitor these characteristics; and, evolution of these characteristics through lifetime and storage conditions.

36 MATERIALS SCIENCE↗

Extending Data-Driven Anomaly Detection Methods to Transient Power Conditions in Nuclear Power Plants

Historically, nuclear power plants have operated predominantly at or near full power, meaning that data driven anomaly detection methods can likely perform well at full power operations. This presents a challenge when the power drops (referred to as a transient) and may result in false alarms due to the lack of historical data at those new power levels. The current approach to handling this challenge is to turn detectors off during transients, which makes it impossible to use the algorithms to detect anomalies during these periods, i.e., causing missed detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗