Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NREL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Clean Energy Transformation in Bangladesh

Since 2011, the United States Agency for International Development (USAID) and the U.S. Department of Energy’s National Renewable Energy Laboratory (NREL) have partnered to support Bangladesh’s energy transition by enabling the deployment of advanced energy systems. The USAID-NREL Partnership launched the Reinforcing Advanced Energy Systems (RAES) program in May 2021 as a mechanism for providing a broader array of technical assistance to the Government of Bangladesh in support of their goal to promote renewable energy development to stimulate private sector investment, rural economic development, and to meet growing energy demand through domestic energy resources. This fact sheet reviews how USAID and NREL collaborate in Bangladesh to improve energy access and security and stimulate economic growth through the deployment of advanced energy systems.

Bangladesh↗

Cambium 2024 Scenario Descriptions and Documentation

The National Renewable Energy Laboratory's (NREL's) Cambium data sets are annually released sets of simulated hourly data for a range of modeled futures of the U.S. electric sector with metrics designed to be useful for long-term decision- making. The 2024 Cambium data set is the fifth annual release. The data sets are a companion product to NREL's Standard Scenarios, which are likewise released annually and are a set of projections of how the U.S. electric sector could evolve across a suite of different potential futures, but covering more scenarios with less temporal granularity. Information about Cambium and related publications can be found at https://www.nrel.gov/analysis/cambium.html, and the Cambium data sets can be viewed and downloaded at https://scenarioviewer.nrel.gov/. In this documentation, we describe Cambium 2024's scenarios, define the metrics, and document the Cambium-specific methods for calculating those metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Master Services Agreement - Flexible Feeder/Distribution System Support: Cooperative Research and Development (Final Report)

PGE will engage NREL on a broad range of projects related to the integration of distributed energy resources (DERs) into the utility's operations. This portfolio of work could include projects focused on DER adoption models, advanced distribution management system (ADMS) and distributed energy management system (DERMS) design, DER dispatch strategy development, and DER valuation framework development. Additional topics could include long-term energy planning, renewable energy, energy efficiency and demand-side management. As well as technology evaluations and design guidance for building retrofits and new construction projects, energy and energy infrastructure planning, policies, and markets (and their analysis), energy storage, energy security and resilience (including energy system-related cybersecurity), transportation and mobility, technology integration analysis. Additionally, other assistance as requested by PGE consistent with NREL’s expertise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Route Energy Prediction (RouteE) Powertrain Validation Report

The National Renewable Energy Laboratory's flagship package in the RouteE suite, RouteE-Powertrain, is a mesoscopic energy model that predicts vehicle energy consumption given discrete attributes that describe each segment or link in a vehicle's path on a road network. High-frequency, physics-based, powertrain simulators, such as NREL's FASTSim, are well-suited to model vehicle energy consumption when real driving data and a detailed understanding of the vehicle powertrain specifications are available. However, there are a variety of situations in the past, present (real-time), and future where high-frequency driving data and/or vehicle information may not be available, but reliable energy consumption is still desired, such as energy-aware vehicle routing. These are the ideal applications for RouteE-Powertrain. The suite of RouteE tools also includes RouteE-Compass, which is an eco-routing software that incorporates energy consumption into network routing algorithms, and RouteE-Mobile, which is a prototype smartphone navigation app to demonstrate the integrated capabilities of the RouteE suite for real-world eco-routing. The focus of this validation report is to share key metrics about the data sets and models behind RouteE-Powertrain. The set of RouteE-Powertrain models discussed in this report are made available through the RouteE web API through the NREL Developer Network.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of High Throughput Screening Methods in Picking up Differences between Cultivars of Lignocellulosic Biomass for Ethanol Production

Here, we present a unique evaluation of three advanced high throughput pretreatment and enzymatic hydrolysis systems (HTPH-systems) for screening of lignocellulosic biomass for enzymatic saccharification. Straw from 20 cultivars of winter wheat from two sites in Denmark was hydrothermally pretreated and enzymatically processed in each of the separately engineered HTPH-systems at 1) University of California, Riverside, 2) National Renewable Energy Laboratory (NREL), Colorado, and 3) University of Copenhagen (CPH). All three systems were able to detect significant differences between the cultivars in the release of fermentable sugars, with average cellulose conversions of 57%, 64%, and 71% from Riverside, NREL and CPH, respectively. We found the best correlation of glucose yields between the Riverside and NREL systems (R2 = 0.2139), and the best correlation for xylose yields was found between Riverside and CPH (R2 = 0.4269). The three systems identified Flair as the highest yielding cultivar and Dinosor, Glasgow, and Robigus as low yielding cultivars. Despite different conditions in the three HTPH-systems, the approach of microscale screening for phenotypically less recalcitrant feedstock seems sufficiently robust to be used as a generic analytical platform.

09 BIOMASS FUELS↗

Variations in the Chemical and Electronic Impact of Post-Deposition Treatments on Cu(In,Ga)(S,Se) 2 Absorbers

We present a comparative study that focuses on the variability of post-deposition treatments (NaF-PDT and KF-PDT) and their impact on the chemical and electronic structure of chalcopyrite thin film solar cell absorbers. For this purpose, two 'extreme' chalcopyrite absorber systems are studied: Cu(In,Ga)(S,Se)2 with industrial relevance (STION), and Cu(In,Ga)Se2 with 'research grade' properties (NREL). Samples were subjected to NaF-PDT and KF-PDT, and investigated using x-ray and ultra-violet photoelectron spectroscopy, Auger electron spectroscopy, as well as synchrotron-based soft x-ray emission spectroscopy. Considerably different alkali-induced effects are found for the two systems. In particular, we only detect a PDT-related Cu depletion on the NREL absorber surfaces (and only on those leading to high-efficiency devices). We also observe a reduction in the surface S/Se ratio for all alkali-treated STION absorbers, in addition to the presence of sulfates after the KF-PDT. After processing the PDT absorbers to fully operating cells, we find that the PDT temperature has a significant impact on the resulting device efficiencies - both the NREL and STION absorbers can result in high-efficiency and low-efficiency devices, depending on KF-PDT processing parameters. The absorbers of low-efficiency KF-PDT devices show the largest Cu surface content after PDT, causing the valence band maximum to be closer to the Fermi energy, thus possibly leading to less efficient charge-carrier separation and/or enhanced recombination at the interface. Finally, we find varying degrees of Na, K, and/or F residuals on the different absorber surfaces after PDT, indicating a potential 'hidden' parameter in employing PDTs for improved solar cell performance.

14 SOLAR ENERGY↗

Analysis of Automated Transit Network Systems with Battery-Electric Vehicles in Automated Mobility Districts: Preprint

The paper provides an overview of the insights and findings of the National Renewable Energy Laboratory's (NREL) ongoing research on the implementation of automated mobility districts (AMDs). AMD is a term coined by NREL to describe a geographically defined district or major activity center located in a dense urban setting with mobility applications provided by automated/autonomous vehicle (AV) systems spanning internal circulation and first-mile/last-mile connections to regional transportation hubs. Research over the past five years has focused on understanding the evolution of AMDs, beginning with demonstrations of automated shuttles prior to the pandemic, to more integrated on-demand mobility systems currently in initial stages of deployment. Initial insights and findings from earlier studies include the need for designation of a "jurisdiction having authority," a clear vision of a complete system to provide end-to-end mobility services, and the requisite intelligent infrastructure to complement AV technology. NREL's most recent Phase III research investigates station boarding/alighting (curb) issues, the full electrification of fleets, and the need for a systems engineering methodology (SEM) to properly analyze the complexities resulting from the convergence of automation, on-demand mobility, and electrification of the transit systems within the AMD. The paper reviews the findings of AMD research conducted during Phase I, II, and III, with special emphasis on Phase III results with respect to a descriptive example of the proposed SEM when a "digital twin" analytical model is used to simulate the transport fleet's battery-electric vehicle miles of travel and associated duty cycles through a rigorous analytical assessment with a comprehensive modeling process.

ADVANCED PROPULSION SYSTEMS↗

Long-Term Heating to Improve Receiver Performance

The buildup of hydrogen in the heat transfer fluid (HTF) that circulates through components of parabolic trough power plants decreases receiver thermal efficiency, and ultimately, it decreases plant performance and electricity output. The generation and occurrence of hydrogen in the HTF provides the driving force for hydrogen to permeate from the HTF through the absorber tube wall and into the receiver annulus. Getters adsorb hydrogen from the annulus volume until they saturate and are no longer able to maintain low hydrogen pressure. The increase in hydrogen pressure within the annulus significantly degrades thermal performance of the receiver and decreases overall power-plant efficiency. NREL and Acciona Energy North America (Acciona) are developing a method to control the levels of dissolved hydrogen in the circulating HTF. The basic approach is to remove hydrogen from the expansion tanks of the HTF subsystem at a rate that maintains hydrogen in the circulating HTF to a target level. Full-plant steady-state models developed by the National Renewable Energy Laboratory (NREL) predict that if hydrogen is removed from the HTF within the expansion tanks, the HTF that circulates through the collector field remains essentially free of hydrogen until the HTF returns to the power block in the hot headers. One of the key findings of our modeling is the prediction that hydrogen will reverse-permeate out of the receiver annulus if dissolved hydrogen in the HTF is kept sufficiently low. To test this prediction, we performed extended heating of an in-service receiver that initially had high levels of hydrogen in its annulus. The heating was performed using NREL's receiver test stand. Results of our testing showed that receiver heat loss steadily decreased with daily heating, resulting in a corresponding improvement in receiver thermal efficiency.

14 SOLAR ENERGY↗

Hydrogen Mitigation Process Testing at Nevada Solar One

The National Renewable Energy Laboratory (NREL) and Acciona Solar Power (ASP) developed and installed a process that addresses the issue of hydrogen buildup in Acciona's Nevada Solar One power plant. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). During previous work, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. We demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 10 mbar down to 0.003 mbar. More recently, we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Laboratory testing at NREL showed that the sensor function had an accuracy of +/-7%, and the hydrogen extraction rate for separator function was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. Most recently, NREL and ASP completed installation and initial testing of a mitigation process at ASP's Nevada Solar One power plant in Boulder City, Nevada. In this paper, we report on the completed installation, initial testing, and plans to bring the process to full automation, so that it can be operated unattended on a daily schedule.

chemical elements↗

A convective wind resource model for Solar Vortex power generation

Climate change has increased the need for clean, nonpolluting energy sources to decrease dependence on fossil fuels. Alternative energy sources, mainly solar and horizontal wind, have been the primary focus for producing clean energy. New technologies are being developed, such as the Solar Vortex (SoV), which was developed at the Georgia Institute of Technology, and relies on a vertical wind resource to generate power. The National Renewable Energy Lab (NREL) has resource models representing solar and horizontal wind resources across the 48 United States. This research developed a vertical wind resource model that is comparable in resolution to NREL’s solar and horizontal wind resource models and uses the model for estimating power output for the SoV. This model complements NREL’s existing resource models and supports the deployment of an additional clean energy generation technology. The model was applied to Mesa, Arizona to find feasible sites for a small-scale vertical wind farm.

14 SOLAR ENERGY↗

Thermal Management and Reliability of Power Electronics and Electric Machines

Increasing the number of electric-drive vehicles (EDVs) on America's roads has been identified as a strategy with near-term potential for dramatically decreasing the nation's dependence on oil - by the U.S. Department of Energy, the federal cross-agency EV-Everywhere Challenge, and the automotive industry. Mass-market deployment will rely on meeting aggressive technical targets, including improved efficiency and reduced size, weight, and cost. Many of these advances will depend on optimization of thermal management. Effective thermal management is critical to improving the performance and ensuring the reliability of EDVs. Efficient heat removal makes higher power densities and lower operating temperatures possible, and in turn enables cost and size reductions. The National Renewable Energy Laboratory (NREL), along with DOE and industry partners is working to develop cost-effective thermal management solutions to increase device and component power densities. In this presentation, the activities in recent years related to thermal management and reliability of automotive power electronics and electric machines are presented.

30 DIRECT ENERGY CONVERSION↗

Charge Management for an Inductively Charged On-Demand Battery-Electric Shuttle Service with High Penetration of Renewable Energy

This paper presents a charge management control strategy for an on-demand battery-electric shuttle van operating at the National Renewable Energy Laboratory (NREL) campus and supported by day-time inductive charging at the vehicle's waiting spot. A new control algorithm has been proposed for reducing the demand charge costs incurred from wireless charging of the on-demand shuttle. A custom controller has been developed to monitor the shuttle, wireless charger, renewable energy generation, and various loads at NREL's campus, and regulate charging behavior for demand response. The intermittent renewable generation and sporadic operation of the on-demand shuttle service contribute to a high level of uncertainty in expected campus load profile, which must be carefully managed. The control algorithm predicts energy profile to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller has been designed and optimized using a Simulink model for the entire system. Next, it has been implemented and tested in real-time on the NREL campus. Two primary vehicle-use cases, charge sustaining and charge depletion operation, are tested under different load profiles and drive cycles to assess the controller's effectiveness at reducing peak demand and therefore demand charges. The proposed controller showed robust performance under different driving scenarios with high correlation between simulated and experimental data. The results showed that proper demand response can be achieved with an average of 94% reduction of charging loads during peak demand events.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Asynchronous and Distributed Tracking of Time-Varying Fixed Points

NREL researcher Andrey Bernstein discusses asynchronous and distributed tracking of time-varying fixed points as part of the Innovative Optimization and Control Methods for Highly Distributed Autonomous Systems workshop. NREL hosted the workshop to exchange ideas on state-of-the-art control and optimization strategies as well as get feedback on work being done at NREL.

97 MATHEMATICS AND COMPUTING↗

Integrating Energy-Efficient Computing with Computational Research to Accelerate Energy Technology

NREL's computational sciences center hosts the largest high performance computing (HPC) capabilities dedicated to energy research while functioning as a living laboratory for energy-efficient computing. NREL's HPC capabilities support the research needs of the Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). In ten years of operation, HPC use in EERE-sponsored research has grown by a factor of 30, including work in electricity generation, energy efficiency, transportation, and energy system modeling. This paper analyzes this research portfolio, providing examples of individual use cases. The paper documents NREL's history of operating one of the world's most energy-efficient data centers while examining pathways to reduce economic and environmental impact beyond reduction of Power Usage Efficiency (PUE). This paper concludes by examining the unique opportunities created for accelerating improvements in data center efficiency created by combining an HPC system dedicated to energy research and a research program in energy-efficient computing.

97 MATHEMATICS AND COMPUTING↗

Using Measured Plane-of-Array Data Directly in Photovoltaic Modeling: Methodology and Validation

Measured plane-of-array (POA) irradiance may provide a lower-cost alternative to standard irradiance component data for photovoltaic (PV) system performance modeling without loss of accuracy. Previous work has shown that transposition models typically used by PV models to calculate POA irradiance from horizontal data introduce error into the POA irradiance estimates, and that measured POA data can correlate better to measured performance data. However, popular PV modeling tools historically have not directly used input POA data. This paper introduces a new capability in NREL's System Advisor Model (SAM) to directly use POA data in PV modeling, and compares SAM results from both POA irradiance and irradiance components inputs against measured performance data for eight operating PV systems.

14 SOLAR ENERGY↗

Net Zero Energy Analysis Approach for Military Installations

Net zero energy is a concept of energy self-sufficiency based on minimized demand and use of local renewable energy resources. A net zero energy military installation is defined as: 'A military installation that produces as much energy on-site from renewable energy generation or through the on-site use of renewable fuels, as it consumes in its buildings, facilities, and fleet vehicles.' [1] TheNational Renewable Energy Laboratory (NREL) developed a comprehensive, first-of-its-kind strategy for evaluating a military installation's potential to achieve net zero energy status, including an assessment of baseline energy use, energy use reduction opportunities from efficiency or behavior changes, renewable energy generation opportunities, electrical systems analysis of renewableinterconnection, microgrid potential, and transportation energy savings. This paper describes NREL's net zero energy assessment strategy and provides a planning guide for other organizations interested in evaluating net zero potential. We also present case studies and describe lessons learned from NREL's net zero energy assessments at seven installations, including the importance of enforcing and funding mandates, providing leadership support, collecting accurate data, and selecting appropriate technologies. Finally, we evaluate whether the net zero concept is a useful framework for analyzing an energy strategy and a reasonable goal.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Load Mitigation on Floating Offshore Wind Turbines with Advanced Controls and Tuned Mass Dampers

General Electric, the National Renewable Energy Laboratory (NREL), the University of Massachusetts Amherst (UMass), and Glosten have recently completed a US Department of Energy (DOE)-funded research program to study technologies for mitigating loads on floating offshore wind turbines through the use of advanced turbine controls and tuned mass dampers (TMDs). The analysis was based upon the Glosten PelaStar tension leg platform (TLP) with GE Haliade 150 turbine, a system developed in a previous front end engineering design (FEED) study funded by the Energy Technology Institute (ETI) in the UK. The platform was designed for the WaveHub wave energy research site, with a mean water depth of 59-m. Loads were analyzed by running time-domain simulations in four 50-year return period (50-YRP) ultimate load state (ULS) conditions and 77 fatigue load state (FLS) environmental conditions. In 50-YRP conditions advanced controls are not active. The influence of TMDs on ULS loads have been reported previously (Park et al. [2]). In FLS conditions advanced controls and TMDs afford dramatic reductions in fatigue damage, offering the potential of significant savings in tower structural requirements. Simulations in turbine idling conditions were run in OrcaFlex, and simulations in operating conditions were run in FAST. Simulations were run with a baseline turbine controller, representative of the current state of the art, and an advanced controller developed by NREL to use collective and individual blade pitch control to maintain rotor speed and reduce tower loads. UMass developed a number of TMD types, with varying system configurations, including passive nonlinear dampers and semi-actively controlled dampers with an inverse velocity groundhook control algorithm. Loads and accelerations in FLS conditions were evaluated on the basis of damage equivalent loads (DELs), and fatigue damage was computed by Miner's summations of stress cycles at the tower base. To study sensitivity to water depth, loads were analyzed at both the 59-m WaveHub depth and a more commercially realistic depth of 100 m. TMDs reduce fatigue damage at the tower-column interface flange by up to 52% in 59-m water depth and up to 28% in 100 m water depth. Advanced controls reduce fatigue damage at the tower-column flange by up to 22% in 59-m water depth and up to 40% in 100 m water depth. The most effective load-mitigation strategy is combining advanced controls with TMDs. This strategy affords a 71% reduction in fatigue damage in both 59-m and 100-m water depths.

17 WIND ENERGY↗

Framework for Unified Systems Engineering and Design of Wind Plants (FUSED-Wind) cost models and case analyzer [SWR-14-25]

Framework for Unified Systems Engineering and Design of Wind Plants ( FUSED-Wind) is an open-source framework for multi-disciplinary optimisation and analysis (MDAO) of wind energy systems, developed jointly by DTU and NREL. The framework is designed as an extension to the NASA developed OpenMDAO, and defines key I/O elements and methods necessary for wiring together different simulation codes in order to achieve a system level analysis capability of wind turbine plants with multiple levels of fidelity. NREL and DTU have developed independent interfaces to their respective simulation codes and cost models (e.g. FAST/CCBlade, HAWC2/BECAS) with the aim of offering an environment where these codes can be used interchangeably. The open source nature of the framework enables third parties to develop interfaces to their own tools, either replacing or extending those offered by DTU and NREL.

Dykes, Katherine↗