Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “N2”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Fifty Years of Exploring Pluto: from Telescopes to the New Horizons Mission

Pluto was discovered in 1930 at Lowell Observatory in the belated resumption of a wide-field photographic search originally be-gun at Percival Lowell’s direction prior to his death in 1916. Photometry in the 1950s established the rotation period of 6.4 hours and a color redder than the Sun, but the mass, density, size and albedo were unknown. Near-infrared photometry in 1976 indicated the presence of CH4 frost, suggestive of a relatively high surface albedo and a diameter comparable to the Moon. The large satellite Charon was discovered in 1978, followed by an epoch of mutual transits and occultations of Pluto and Charon from 1985 to 1990, as viewed from Earth. These events resulted in reliable sizes and masses of the two bodies, as well as the orbit of Charon. The mutual events also demonstrated that Pluto and Charon are in locked synchronous rotation and revolution, a configuration unique among the planets. The atmosphere of Pluto was discovered in 1988 from a stellar occultation observed from the Kuiper Airborne Observatory and ground stations, with indications of a haze layer (or a temperature inversion) in the lower atmosphere. Sub-sequent stellar occultations showed that the extent of the atmosphere is variable on a timescale of a few years. The spectroscopic detection of N2 and CO ice in 1993 demonstrated that the atmosphere must be primarily composed of N2, with CH4 and CO as minor components; the spectroscopic detection of gaseous CH4 was reported in 1994.

Cruikshank, D. P.↗

Long Term Biological Treatment of Space Habitation Waste Waters in a One Stage MABR: Comparison of Operation for N and C Oxidation With and Without Simultaneous Denitrification

Aerobic biological stabilization has been previously demonstrated for full size MABR?s (CoMANDR 1.0, CoMANDR 2.0, and R-CoMANDR) over operating periods of ~1 year. These systems have successfully treated a variety of possible habitation waste streams including an ISS (urine + flush and humidity condensate) and Early Planetary Base (EPB) wastewater (urine, flush water, hygiene wastewater, and laundry). Biological stabilization has a number of advantages including: 1) elimination of hazardous pre-treat chemicals; 2) production of NOx species (that can be easily rejected by evaporative or membrane systems); 3) elimination of volatile organic constituents; 4) a low pH effluent that facilitates membrane and distillation processes; and 5) a effluent that produces a better quality and less hazardous brine for water recovery. Previous work has primarily evaluated aerobic operation in which organic carbon and nitrogen is converted to CO2 and NOx-, respectively. An alternative to aerobic operation would be to include anoxic operation to promote denitrification and production of N2 gas. This allows for production of make-up gas as well as reduces the O2 demand and can increase ammonia oxidation efficiency. We evaluated the operation of a full scale (2 crew/day) MABR operated to perform oxidation of organic carbon and nitrogen with and without simultaneous reduction of oxidized N to N2 gas, simultaneous nitrification denitrification (SNDN). The system was challenged with a variety of space habitation wastewaters ranging from an ISS composition to a possible EPB waste stream under both continuous and on-production feeding modes. The system has been operated for over 2.5 years. We report on an overall comparison of aerobic oxidation and SNDN operational regimes to evaluate the system with the best overall attributes to support recycling of space habitation waste streams.

Biological water processing↗

The Peculiar Volatile Composition of CO-Dominated Comet C/2016 R2 (PanSTARRS)

Comet C/2016 R2 (PanSTARRS) has a peculiar volatile composition, with CO being the dominant volatile, as opposed to H2O, and one of the largest N2/CO ratios ever observed in a comet. Using observations obtained with the Spitzer Space Telescope, NASA’s Infrared Telescope Facility, the 3.5 m Astrophysical Research Consortium telescope at Apache Point Observatory, the Discovery Channel Telescope at Lowell Observatory, and the Arizona Radio Observatory 10 m Submillimeter Telescope, we quantified the abundances of 12 different species in the coma of R2 PanSTARRS: CO, CO2, H2O, CH4, C2H6, HCN, CH3OH, H2CO, OCS, C2H2, NH3, and N2. We confirm the high abundances of CO and N2 and heavy depletions of H2O, HCN, CH3OH, and H2CO compared to CO reported by previous studies. We provide the first measurements (or most sensitive measurements/constraints) on H2O, CO2, CH4, C2H6, OCS, C2H2, and NH3, all of which are depleted relative to CO by at least 1–2 orders of magnitude compared to values commonly observed in comets. The observed species also show strong enhancements relative to H2O, and, even when compared to other species like CH4 or CH3OH, most species show deviations from typical comets by at least a factor of 2–3. The only mixing ratios found to be close to typical are CH3OH/CO2 and CH3OH/CH4. The CO2/CO ratio is within a factor of 2 of those observed for C/1995 O1 (Hale- Bopp) and C/2006 W3 (Christensen) at a similar heliocentric distance, though it is at least an order of magnitude lower than many other comets observed with AKARI. While R2 PanSTARRS was located at a heliocentric distance of 2.8 au at the time of our observations in 2018 January/February, we argue, using sublimation models and comparison to other comets observed at similar heliocentric distance, that this alone cannot account for the peculiar observed composition of this comet and therefore must reflect its intrinsic composition. We discuss possible implications for this clear outlier in compositional studies of comets obtained to date and encourage future dynamical and chemical modeling in order to better understand what the composition of R2 PanSTARRS tells us about the early solar system.

McKay, Adam J.↗

Characterization of CO 4th Positive Radiation in CO2-Ar Mixtures

This paper presents measurements and simulations of CO 4th Positive spectra obtained in NASA Ames Research Center's Electric Arc Shock Tube (EAST) and CentraleSupelec's Plasma Torch. The experiments were aimed at measuring optically thin emission for the main band features of CO 4th Positive by using test gas mixtures of CO2 and Ar. By using mixtures of CO2 and Ar, the temperature of the flow (and consequently black-body curve) is increased compared to using pure CO2 (or CO2 / N2 mixtures). This temperature increase allows for emission spectroscopy of features that would nominally be black-body limited for conditions relevant to Mars entry. The CO 4th Positive system is the focus of this study as it accounts for a large percentage of the emitted radiation for Martian entry, and also due to the difficulties of obtaining experimental validation data due to the emission appearing in the Vacuum Ultraviolet (VUV) spectral range. The focus of this paper is to provide a comprehensive comparison between the EAST and plasma torch data along with various CO 4th Positive databases available in the literature. Previously reported VUV CO2 / N2 EAST data required a larger temperature than would be predicted based upon equilibrium shock relations. The need for the temperature increase implies that the EAST experiment did not fully equilibrate. Thus, it is presumed that the EAST data did not obtain an equilibrium condition. The plasma torch data, on the other hand, is very consistent with equilibrium assumptions. Thus, the equilibrium data obtained in the plasma torch is utilized to construct the CO 4th Positive emission model, which is then applied to the EAST data with a non-equilibrium interpretation.

A. M. Brandis↗

Small Particle Glovebox Experiments - Preliminary Results

A substantial portion of the asteroid samples returned by the HAYABUSA2 and OSIRIS-REx missions will consist of small (submm) components (due to the collection of those particles on the asteroid surface and due to the fragmenting of larger, friable material post-collection). In order to minimize the alteration/oxidation of asteroid regolith, the bulk collections will be stored and curated in nitrogen purged gloveboxes. The processing of small particles in an N2 glovebox will present challenges that are different from those experienced during lunar and meteorite sample processing. Particles in this size range are susceptible to unpredictable electrostatic charging that can result in sample loss during processing operations. Methods for the handling of sub-mm particles have been well developed for environments with ambient atmospheric conditions and relative humidity (RH) ranges between 40-70%. In such conditions, a number of factors can be successfully employed to minimize the effects of triboelectric charging, including the use of Po-210 sources that neutralize excess charge and the utilization of conductive manipulation tools and sample substrates. However, relative humidity levels above 40% also contribute significantly to dissipation of triboelectric effects. We had not previously investigated our charge mitigation methods in a completely dry, nitrogen-purged environment, or whether they would be sufficient in enabling the successful processing of sub-mm samples. Current glovebox configurations in use in our lunar and meteorite curation laboratories are optimized for the processing of macroscopic samples and tools; these glovebox designs are likely unsuitable for the processing of collections for which the bulk collection is comprised of sub-mm components. Small particle sample preparation requires the use of an optical magnification instrument – typically a stereo binocular microscope with at least 20x magnification. Current glovebox designs are not optimized for the utilization or integration of stereo microscopes; while many current cabinets include microscope viewports that enable the use of small, externally mounted stereo microscopes, the focusing methods (usually involving the use of a lab jack) lack the fidelity and precision required for small particle manipulation and imaging. Working distances of higher (>50x magnification) objective lenses may preclude the external use of a stereo microscope through a viewport; in order to successfully manipulate and image very small (< 20m) particles, stereo and digital microscope systems that are integrated within the glovebox should be investigated. Finally, ergonomic considerations for small particle work within a glovebox must be considered to minimize risk of injury to sample processors. In order to investigate some of the unknown parameters relating to small particle processing within an N2 glovebox, we conducted preliminary, qualitative experiments utilizing a small lunar cabinet that was originally used for film development.

C. J. Snead↗

Burning and Suppression of Solids–II (BASS-II) Summary Report

The Burning and Suppression of Solids (BASS) experiment hardware is a small flow duct that provides containment for small scale burning of solid samples within the Microgravity Science Glovebox (MSG) aboard the International Space Station (ISS). A video camera with a data overlay and a 35-mm still camera record the combustion events. The controls (ignition, fan speed, etc.) are operated by an astronaut while the principal investigator team monitors the experiment from the ground and communicates directly with the astronaut. For the first time on ISS, BASS–II utilized MSG working volume dilution with gaseous N2. We developed a perfectly stirred reactor model to determine the N2 flow time and flow rate to obtain the desired reduced O2 concentration in the working volume for each test. We calibrated the model with the Compound Specific Analyzer-Combustion Products (CSA-CP) O2 readings offset using the Major Constituents Analyzer reading of the ISS ambient atmosphere data for that day. This worked out extremely well for operations, and added a new vital variable, ambient O2 level, to our test matrices. The main variables tested in BASS–II were ambient O2 concentration, ventilation flow velocity, and fuel type, thickness, and geometry. BASS–II also utilized the onboard CSA-CP for O2 and CO readings, and the Carbon Dioxide Monitor for CO2 readings before and after each test. Readings from these sensors allow us to evaluate the completeness of the combustion. The O2 and CO2 readings before and after each test were analyzed and compared very well to stoichiometric ratios for a one-step gas-phase reaction. The CO versus CO2 followed a linear trend for some datasets, but not for all the different geometries of fuel and flow tested. We calculated the heat release rates during each test from the O2 consumption and burn times, using the constant 13.1 kJ of heat released per gram of O2 consumed. The results showed that most of the tests had heat release rates well below 100 W. Lastly, the global equivalence ratio for the tests is estimated to be fuel rich, 1.3 on average using mass loss and O2 consumption data.

Microgravity↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permanent presence on the moon and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential.[1] In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen(LO2) for not only breathable air, but also for rocket propellant. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith.[2],[3] Although there are numerous minerals within regolith and various processes to extract O2,this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2(or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide(CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28.

Mass Spectrometry↗

The Dark Side of Pluto

During its departure from Pluto, New Horizons used its LORRI camera to image a portion of Pluto's southern hemisphere that was in a decades-long seasonal winter darkness, but still very faintly illuminated by sunlight reflected by Charon. Recovery of this faint signal was technically challenging. The bright ring of sunlight forward-scattered by haze in the Plutonian atmosphere encircling the nightside hemisphere was severely overexposed, defeating the standard smeared-charge removal required for LORRI images. Reconstruction of the overexposed portions of the raw images, however, allowed adequate corrections to be accomplished. The small solar elongation of Pluto during the departure phase also generated a complex scattered-sunlight background in the images that was three orders of magnitude stronger than the estimated Charon-light flux (the Charon-light flux is similar to the flux of moonlight on Earth a few days before first quarter). A model background image was constructed for each Pluto image based on principal component analysis applied to an ensemble of scattered-sunlight images taken at identical Sun−spacecraft geometry to the Pluto images. The recovered Charon-light image revealed a high-albedo region in the southern hemisphere. We argue that this may be a regional deposit of N2 or CH4 ice. The Charon-light image also shows that the south polar region currently has markedly lower albedo than the north polar region of Pluto, which may reflect the sublimation of N2 ice or the deposition of haze particulates during the recent southern summer.

Pluto↗

Design of a Subscale, Inert Gas Test for Plume-Surface Interactions in a Reduced Pressure Environment

Rocket plume-surface interaction is a multi-phase, complex discipline characterized by plume flow physics, erosion physics, and ejecta dynamics. To provide critical data for the validation of predictive modeling capabilities, an inert-gas, subscale ground test has been designed, with one test phase focused on cratering and ejecta and another test phase focused on plume structure and behavior. Using a supersonic, heated N2 jet impinging onto six different mechanical regolith simulants, visual data on the temporal evolution of cratering and ejecta are collected in a vacuum chamber at ambient pressures ranging from 600 Pa down to approximately 7 Pa. Using the same N2 jet impinging onto an instrumented plate, NO planar laser-induced fluorescence data are obtained at lower ambient pressures for the validation of both continuum and rarefied gas-phase physics. This paper discusses the design of this test and data products, with emphasis on the cratering and ejecta experiments, along with the physical scaling, challenges, and relevance of these data to the maturation of the plume-surface interaction discipline.

Ashley M Korzun↗

Laboratory Investigation of the Effect of Venusian Weathering on Mineral Spectra

Introduction: The recent selection of two missions to Venus has renewed the importance of deter-mining weathering reactions between minerals and the Venusian atmosphere, and the spectral signatures of minerals before, during, and after these reactions. The rate at which weathering reactions progress also constrain show long unstable minerals will be present on the surface (e.g., [1]), and enables the use of mineralogy as a constraint on surface age(e.g., [2-3]).In order to gain an understanding of how mineral compositions and spectra change with weathering, we have begun conducting experiments in a 1 atm experimental setup at Wesleyan University. This setup exposes minerals to the temperature and most abundant gases of the Venus atmosphere (CO2, SO2, N2).We conducted initial experiments using biotite, calcite, and montmorillonite in order to test our methodology with minerals that may be relevant to recording the history of water on Venus. Methods: Experiments were conducted in Thermo Fisher Scientific Lindberg/Blue M Mini-Mite horizontal tube furnaces at Wesleyan University. Experiments used natural mineral chips and powders, and were conducted at 1 atmosphere and 460 °C under pre-mixed gases provided by Air Gas(Table 1). The furnaces are set up in a flow through configuration so that solid samples are exposed to a fixed gas composition, and quartz glass process tubes were used in all experiments (1/4” diameter for experiment V4, ½” diameter for all others). These conditions were maintained for the du-rations listed in Table 1, at which point the furnace was turned off with gas flowing until the sample was cool enough to extract under N2and be placed in a desiccator for storage. Run products were carbon coated and examined using a Hitachi SU5000 Field Emission Gun Scanning Electron Microscope (SEM) equipped with an EDAX Octane Pro EDS detector located at Wesley-an University. Visible-Near Infrared Spectroscopy (VNIR) analysis was performed on powdered samples under a nitrogen atmosphere using an ASD Fieldspec Proover the 350-2500 nm range. Powdered mineral samples were milled to a particle size of < 45μm and were spiked with an internal standard (Al2O3, corundum) to obtain quantitative mineralogy. Samples were analyzed using a Panalytical X’Pert pro X-ray Diffractometer (XRD), with an X’Celerator high speed detector and Co Kα radiation, with data collected at a step size of 0.02 ̊/minute step counting rate from 2 to 80 degrees 2θ at 45 mA/40kV in the X-ray Diffraction Laboratory located at NASA Johnson Space Center. Materials Data Inc (MDI) software suite, JadeTMv9 was used for Rietveld refinement to determine phase abundances and mineral identification by comparing XRD patterns to International Center for Diffraction Data (ICDD) database patterns. Table 1: Experimental matrix. Experiment Name Duration (Days)Gas Com-position (trace gas)MineralsV487SO2/N2(1.4%)Montmorillonite, biotiteV519SO2/N2(1.4%)CalciteV619CO2/SO2/N2(1.4% SO2, 2.1% N2)Montmorillonite, biotiteV828SO2/N2(1.4%)Biotite, calcite Results: Calcite. In both experiments, calcite was exposed to the SO2/N2gas mixture, and in both experimental run products, XRD analysis detected anhydrite, which is consistent with EDS measurements conducted in the SEM. The XRD analyses show greater amounts of anhydrite present after 28 days than 19, suggesting the calcite reaction progressed further given longer duration. Grain surface morphology as seen in the SEM also shows secondary mineral growth (Fig. 1). VNIR spectra show no change, as expected since anhydrite lacks spectral features in this wavelength range. Montmorillonite. Montmorillonite was exposed to two different gas mixtures, the SO2/N2mix and CO2/SO2/N2mix over different durations (87 and 19 days, respectively). VNIR analyses of both run products show a reduction in the 1441and1910 nm water features as well as a shift of the 1411 and 2011 nm features to shorter wavelengths that may indicate re-structuring in the crystal lattice and the production of amorphous phases [4]. XRD results are consistent with this, showing a shift of the 001 peak from 15Åto 10Åin both run products. The amount of X-ray amorphous material in the montmorillonite run products was greater than that present in the unreacted clay, being the greatest in the 87 day V4 experiment. No other secondary phases were detected in the run products, however sulfur was present in EDS analyses of powder samples.

A R Santos↗

Validation of Decompression Sickness Risk Mitigation Protocols for Planetary Spaceflight Missions

BACKGROUND: Apollo missions used a 100% O2 cabin atmosphere which effectively eliminated the risk of decompression sickness (DCS) during extravehicular activity (EVA) on the moon. NASA’s future missions to the moon and Mars are expected to use nitrox gas mixtures of up to 34% O2, 66% N2, which will reduce flammability risk compared with Apollo, but will necessitate Oxygen prebreathe prior to EVA to reduce DCS risk to acceptable levels. Prebreathe protocols used on the space shuttle and International Space Station are validated for microgravity EVAs, but the significantly increased risk of DCS during equivalent ambulatory EVAs make these protocols inapplicable to planetary EVA. An “exploration atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA as a compromise that balances prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. However, this atmosphere may not be used for vehicles that do not support frequent EVA, and with commercial providers and international providers expected to provide landers, pressurized rovers, habitats, and spacesuits, different combinations of vehicle and spacesuit atmospheres are possible and will each require validated prebreathe protocols. OVERVIEW: Key components of a multi-year strategic roadmap include: 1) Establish hypobaric chamber facility capable of supporting 8-person EVA prebreathe validation tests at saturation atmospheres up to 36% O2; 2) validate an EVA physical workload simulation for use during prebreathe validation testing; 3) validate the recommended “exploration atmosphere” prebreathe protocol; 4) validate prebreathe protocols for additional atmospheric combinations that bound the most likely potential operating ranges of future vehicles and spacesuits; and 5) update DCS risk estimation models based on results of prebreathe validation studies. DISCUSSION: Details and data from completion of the first two steps of the strategic roadmap will be presented; the third step is currently underway, with pilot results provided in a companion presentation. Steps four and five will require a multi-year series of chamber tests; collaborations are being pursued.

Andrew F. J. Abercromby↗

First Optical Constants from 0.4 to 1.6 µm of Titan Aerosol Analogs Produced in the NASA Ames COSmIC Facility and Their Use in a New Analysis of Cassini VIMS Observations

We have determined the real and imaginary refractive indices (n and k, respectively), from the visible to the near infrared (0.4 to 1.6 μm), of five laboratory-generated organic refractory materials produced from gas-phase chemistry with the NASA Ames COSmIC facility. The solid samples were produced using a plasma discharge in the stream of a 200-K supersonic jet-cooled expansion of different gas mixtures to study the impact of the molecular precursors on the solid sample optical properties. Three samples were produced from N2:CH4 (95:5) gas mixtures using three different high voltages (700V, 800V and 1000V) to vary the energy in the plasma discharge. One sample was produced from a N2:CH4:C2H2 (94:5:5:0.5) gas mixture, with a high voltage of 1000 V. The fifth sample was produced in an Ar:CH4 (95:5) gas mixture with a high voltage of 1000 V to produce a nitrogen-free hydrocarbon sample. The optical constants, n and k, of these five samples were determined using spectral reflectance measurements. They appear to be positively correlated with the nitrogen content in the solid sample, i.e., a sample with larger nitrogen content exhibits higher n and k values. We have used these refractive indices as input parameters in a radiative transfer model to analyze Cassini Visible Infrared Mapping Spectrometer (VIMS) observations of Titan’s atmosphere. The results show that using the tholin samples with higher n and k values (higher nitrogen content) provides a better fit to the observational data than using the samples with lower n and k values (lower nitrogen content). The Titan tholins with higher nitrogen content therefore appear to be more representative of the Titan aerosols observed by VIMS.

Titan Aerosol Analogs↗

Habitability Assessments And Lessons-learned From 3-day And 11-day Enriched Oxygen Hypobaric Chamber Tests At NASA Johnson Space Center

INTRODUCTION: Decompression sickness (DCS) is a risk to the health and performance of astronauts and high-altitude aircrew. Tolerance to flammability, hypoxia, prebreathe duration, and DCS risk varies across different organizations, vehicles, suits, and destinations, necessitating a variety of DCS risk mitigation approaches. Existing models of altitude DCS risk are often insufficient to enable accurate risk-informed decisions during hardware development, mission planning, and flight operations. METHODS: NASA completed outfitting of a dedicated facility at Johnson Space Center to support testing of up to eight human subjects for multiple days in hypobaric and enriched oxygen atmospheres. The primary purpose of the testing capability is validation of DCS risk mitigation protocols for Artemis missions to the Moon; however, it will also support development and validation of a generalizable altitude DCS risk estimation tool. A 3-day and an 11-day prebreathe validation test were completed in 2022, each with 8 human subjects living at 56.5 kPa (8.2 psia), 34% O2, 66% N2, with 5 simulated EVAs performed on masks at 29.6 kPa (4.3 psi), 85% O2, 15% N2. Facility and organizational lessons-learned and process improvements were recorded during and following the tests, and subjective habitability ratings were recorded daily during the 11-day test. Hypoxia and DCS-related physiological and cognitive outcome measures were recorded during both tests and are reported in companion presentations. RESULTS & DISCUSSION: All subjects completed each of the tests. Primary habitability issues related to mask discomfort during simulated EVAs and poor sleep quality due to thin mattresses. Polybenzimidazole (PBI) clothing was worn by all subjects due to the increased fire risk and may be required for Artemis missions; clothing was found to be acceptable overall with the worst ratings being due to poor fit and inelasticity. Chamber O2 and CO2 sensor inconsistency was observed that did not result in test termination but required post-test follow-up. Forward plans include additional hypobaric testing and integration of existing and future physiological outcome data into an open-source Aerospace Estimation Tool for Hypobaric Exposure Risk (AETHER). NASA is also working to make the testing capability available to commercial companies.

Andrew F J Abercromby↗

Plasma Activated Water for Crewed Transit and Planetary Habitation: A Study of Gas Type, Electrode Material, and Power Supply Selection and the Impact on the Final Frontier - FY21 CIF

An in-depth study of plasma activated water (PAW) generation was conducted to link changes in power supply, electrode material, input gas, and treatment time to the resulting reaction chemistry. These changes in chemistry can help tailor PAW for different space applications. An AC, DC, and nanosecond (ns) pulsed power supply were each used to generate PAW with stainless steel, copper, tungsten, or platinum (Pt) electrodes while utilizing air, nitrogen (N2), carbon dioxide (CO2), helium (He), or argon (Ar) as the feed gas. Tap or deionized (DI) water was treated for 1 to 15 minutes, and the generated PAW was tested for changes in pH, conductivity, oxidation reduction potential, nitrates (NO3-), ammonium (NH4+), and peroxide. Calculations showed that the production of reactive nitrogen species was the leading cause of pH and conductivity changes. The DC generated air plasma was able to reduce the pH of DI water and generate NO3‑. The pulsed supply, operating at 20% of the input power of the DC supply, lowered the pH generated NO3‑. When a simulated Martian gas mixture of 95% CO2 and 5% N2 was used as the feed gas, NO3‑ was generated with the DC and pulsed supplies, respectively. Mixing PAW with plasma generated ash from inedible biomass allowed pH control, thus enhancing PAW’s potential use for sanitation applications. The large shift in pH was used to study sanitation effects of Escherichia coli (E. coli) reduction and Staphylococcus aureus (S. aureus), in which log reductions were found to be negligible. Additionally, the plasma generated ash in combination with PAW was also implemented in 10-day microgreen growth trials, in which PAW and ash resulted in quicker emergence of the microgreens compared to the standard growth conditions and comparable dry masses to Hoagland’s nutrient solution treated samples.

plasma activated water (PAW)↗

Plasma Assisted Nutrient Recovery from Inedible Biomass via Ash Leaching

Sustaining a human presence on the Moon, Mars, or deep space will require closing loops on many life support systems. Some form of agriculture will be required because plants produce the vitamins, antioxidants, and essential oils in our diets that degrade over time in stored foods. In addition, they provide dietary fiber, restore air, and purify water. Growing plants will require recycling nutrients trapped in inedible vegetation. Researchers at KSC have investigated the use of a thermal plasma with various carrier gases to thermally degrade inedible plant biomass for nutrient recovery. Previous work demonstrated a thermally degrading environment such as a muffle furnace improved nutrient recovery from inedible biomass prior to an acid leaching process. However, a muffle furnace is an inefficient process. We have explored the use of a small scale, thermal plasma for degradation of pellets to enhance the breakdown of plant stems, leaves, and debris to further close the nutrient loop. Plasma carrier gases such as carbon dioxide (CO2), nitrogen (N2), and air were used to explore variations in recovery and potential chemical by-products. Plasma processed inedible biomass was added to varying concentrations of acid solution for leaching of nutrients (e.g. potassium (K) , magnesium (Mg), calcium (Ca), and phosphorus (P)) for reuse in the crop production cycle. We also examined total N2 recovery. Results are presented showing the impact of plasma processing prior to acid leaching on recovery of plant nutrients.

Kenneth Engeling↗

Nitrogen in Ancient Mud: A Biosignature?

Nitrogen is an essential nutrient for all life on Earth and possibly elsewhere. Burial of nitrogen bound to organic matter constitutes the major flux of nitrogen into sediments today, which has led to the inference that nitrogen enrichments in sedimentary rocks may be a biosignature. However, abiotic processes such as lightning or volcanism can fix atmospheric N2 and contribute to sedimentary nitrogen burial in the absence of life. It is therefore uncertain whether observed nitrogen enrichments of up to 430 ppm in Paleoarchean metasedimentary biotite grains are indeed biogenic. This study seeks to address that problem with a numerical model. The NH4(+) concentration of an abiotic ocean is modeled as a function of source fluxes, pH-dependent NH3 volatilization, and equilibrated adsorption of NH4(+) onto clay particles. The results suggest that the observed nitrogen concentrations in Paleoarchean biotite can only be reconciled with purely abiotic processes if the ocean was more acidic (pH <6) and/or if the source fluxes from lightning and volcanism were at least an order of magnitude higher (≥10(exp 12) mol/yr) than previously thought. The bulk of the nitrogen is thus most likely of biological origin. While this does not necessitate a particular metabolism such as biological N2 fixation, the data provide evidence of nitrogen utilization back to 3.8 Gyr. Nitrogen abundances could thus provide useful information in extraterrestrial missions.

Early Earth↗

Habitability Assessments And Lessons-learned From 3-day And 11-day Enriched Oxygen Hypobaric Chamber Tests At NASA Johnson Space Center

INTRODUCTION: Decompression sickness (DCS) is a risk to the health and performance of astronauts and high-altitude aircrew. Tolerance to flammability, hypoxia, prebreathe duration, and DCS risk varies across different organizations, vehicles, suits, and destinations, necessitating a variety of DCS risk mitigation approaches. Existing models of altitude DCS risk are often insufficient to enable accurate risk-informed decisions during hardware development, mission planning, and flight operations. METHODS: NASA completed outfitting of a dedicated facility at Johnson Space Center to support testing of up to eight human subjects for multiple days in hypobaric and enriched oxygen atmospheres. The primary purpose of the testing capability is validation of DCS risk mitigation protocols for Artemis missions to the Moon; however, it will also support development and validation of a generalizable altitude DCS risk estimation tool. A 3-day and an 11-day prebreathe validation test were completed in 2022, each with 8 human subjects living at 56.5 kPa (8.2 psia), 34% O2, 66% N2, with 5 simulated EVAs performed on masks at 29.6 kPa (4.3 psi), 85% O2, 15% N2. Facility and organizational lessons-learned and process improvements were recorded during and following the tests, and subjective habitability ratings were recorded daily during the 11-day test. Hypoxia and DCS-related physiological and cognitive outcome measures were recorded during both tests and are reported in companion presentations. RESULTS & DISCUSSION: All subjects completed each of the tests. Primary habitability issues related to mask discomfort during simulated EVAs and poor sleep quality due to thin mattresses. Polybenzimidazole (PBI) clothing was worn by all subjects due to the increased fire risk and may be required for Artemis missions; clothing was found to be acceptable overall with the worst ratings being due to poor fit and inelasticity. Chamber O2 and CO2 sensor inconsistency was observed that did not result in test termination but required post-test follow-up. Forward plans include additional hypobaric testing and integration of existing and future physiological outcome data into an open-source Aerospace Estimation Tool for Hypobaric Exposure Risk (AETHER). NASA is also working to make the testing capability available to commercial companies.

Andrew Abercromby↗

Investigating Commercial Off-The-Shelf (COTS) Glovebox and Support Components Compared to Custom Curatorial Laboratories

There is a need envisioned to investigate the application of commercial off-the-shelf (COTS) systems as tools that could be used within commercial preliminary curation as the expected space economy is supported and begins to take flight. NASA is involved with supporting and developing the space economy [1] and therefore it’s feasible that at some point, a commercial space company would bring back materials and either store initially, or permanently, within COTS equipment as a stand-in for custom curation laboratories. While utilizing opportunities to explore this capability at NASA-Johnson Space Center (JSC) during the establishment of other laboratories [2] it was realized that cleanliness and/or other properties could be evaluated for these COTS systems during their installation in advanced research facilities that are not ISO-class rated clean rooms. Several aspects of a COTS-Curation system were explored including various gloves for curation manipulation within a negative pressure glovebox (Fig.1), Balazs organic and inorganic contaminant levels testing prior to glovebox ever being used, mode swapping comparison of recirculation vs. single pass, constant monitoring of oxygen (O2) and moisture (H2O) levels in various conditions, etc. To acquire inorganic and organic compound loads inside the glovebox, Balazs wafer testing and gas sampling were implemented. These are standardized analytical tests provided by Balazs™ NanoAnalysis, a division of Air Liquide USA. Deployment of 8-inch silicon wafer witness plates for 24-hours in an undisturbed environment capture the organic compound load and inorganic trace metal contents which can be obtained by Vapor Phase Decomposition Inductively Coupled Plasma Mass Spectrometry (VPD ICP-MS). Balazs gas sample analysis was also performed for better measurements of volatile organic compounds (VOC) in glovebox air analyzed by Thermal Desorption Gas Chromatography Mass Spectrometry (TD GC-MS). These analytical testings were carried out in a controlled ultra high pure (UHP) gaseous nitrogen (N2)-purged environment where oxygen and moisture contents were continuously monitored at certain temperature and pressure. The preliminary outcomes of these testings are promising. The COTS systems appear to maintain the steady-state controlled environment for days, if not weeks, with uninterrupted gaseous N2-supply which was operated from a standard medium pressure LN2 250L 230L dewar, exchanged as needed. The outgassing load can be maintained by selecting the glove materials that have the least outgassing and particle shedding performances. Further experiments will be considered to validate the preliminary findings. While this project is exploratory, it is not intended as an endorsement by NASA Curation for approved materials or usage for advanced curatorial activities. NASA does not endorse nor promote any one particular product or company. References: [1] McCubbin F. M. et al. (2019) Space Science Reviews 215:A48. [2] Lewis, E.K. et. al (2024) LPSC LV, Abstract #2457.

Curation↗