Electrolysis Bubbles Make Waterflow Visible

Technique for visualization of three-dimensional flow uses tiny tracer bubbles of hydrogen and oxygen made by electrolysis of water. Strobe-light photography used to capture flow patterns, yielding permanent record that is measured to obtain velocities of particles. Used to measure simulated mixing turbulence in proposed gas-turbine combustor and also used in other water-table flow tests.

Schultz, Donald F.↗

A preliminary study on ice shape tracing with a laser light sheet

Preliminary work towards the development of an automated method of measuring the shape of ice forming on an airfoil during wind tunnel tests has been completed. A thin sheet of light illuminated the front surfaces of rime, glaze, and mixed ice shapes and a solid-state camera recorded images of each. A maximum intensity algorithm extracted the profiles of the ice shapes and the results were compared to hand tracings. Very good general agreement was found in each case.

Mercer, Carolyn R.↗

Systolic array IC for genetic computation

Measuring similarities between large sequences of genetic information is a formidable task requiring enormous amounts of computer time. Geneticists claim that nearly two months of CRAY-2 time are required to run a single comparison of the known database against the new bases that will be found this year, and more than a CRAY-2 year for next year's genetic discoveries, and so on. The DNA IC, designed at HP-ICBD in cooperation with the California Institute of Technology and the Jet Propulsion Laboratory, is being implemented in order to move the task of genetic comparison onto workstations and personal computers, while vastly improving performance. The chip is a systolic (pumped) array comprised of 16 processors, control logic, and global RAM, totaling 400,000 FETS. At 12 MHz, each chip performs 2.7 billion 16 bit operations per second. Using 35 of these chips in series on one PC board (performing nearly 100 billion operations per second), a sequence of 560 bases can be compared against the eventual total genome of 3 billion bases, in minutes--on a personal computer. While the designed purpose of the DNA chip is for genetic research, other disciplines requiring similarity measurements between strings of 7 bit encoded data could make use of this chip as well. Cryptography and speech recognition are two examples. A mix of full custom design and standard cells, in CMOS34, were used to achieve these goals. Innovative test methods were developed to enhance controllability and observability in the array. This paper describes these techniques as well as the chip's functionality. This chip was designed in the 1989-90 timeframe.

Anderson, D.↗

A Quantitative Investigation of Entrainment and Detrainment in Numerically Simulated Convective Clouds: Model Development - Pt. 1

A method is developed which uses numerical tracers to make accurate diagnoses of entraimnent and detrainment rates and of the properties of the entrained and detrained air in numerically simulated clouds. The numerical advection scheme is modified to make it nondispersive, as required by the use of the tracers. Tests of the new method are made, and an appropriate definition of clouds is selected. Distributions of mixing fractions in the model consistently show maximums at the end points, for nearly undilute environmental air or nearly undilute cloud air, with a uniform distribution between. The cumulonimbus clouds simulated here entrain air that had been substantially changed by the clouds, and detrained air that is not necessarily representative of the cloud air at the same level.

Cohen, Charles↗

Effects of Fuel Distribution on Detonation Tube Performance

A pulse detonation engine (PDE) uses a series of high frequency intermittent detonation tubes to generate thrust. The process of filling the detonation tube with fuel and air for each cycle may yield non-uniform mixtures. Lack of mixture uniformity is commonly ignored when calculating detonation tube thrust performance. In this study, detonation cycles featuring idealized non-uniform H2/air mixtures were analyzed using the SPARK two-dimensional Navier-Stokes CFD code with 7-step H2/air reaction mechanism. Mixture non-uniformities examined included axial equivalence ratio gradients, transverse equivalence ratio gradients, and partially fueled tubes. Three different average test section equivalence ratios (phi), stoichiometric (phi = 1.00), fuel lean (phi = 0.90), and fuel rich (phi = 1.10), were studied. All mixtures were detonable throughout the detonation tube. It was found that various mixtures representing the same test section equivalence ratio had specific impulses within 1 percent of each other, indicating that good fuel/air mixing is not a prerequisite for optimal detonation tube performance.

Perkins, Hugh Douglas↗

Bell-Curve Genetic Algorithm for Mixed Continuous and Discrete Optimization Problems

In this manuscript we have examined an extension of BCB that encompasses a mix of continuous and quasi-discrete, as well as truly-discrete applications. FVe began by testing two refinements to the discrete version of BCB. The testing of midpoint versus fitness (Tables 1 and 2) proved inconclusive. The testing of discrete normal tails versus standard mutation showed was conclusive and demonstrated that the discrete normal tails are better. Next, we implemented these refinements in a combined continuous and discrete BCB and compared the performance of two discrete distance on the hub problem. Here we found when "order does matter" it pays to take it into account.

Kincaid, Rex K.↗

Supersonic Inlet with Pylons Set and Star-Shaped Forebody for Mixing, Combustion and Thrust Enhancement

Two new approaches are discussed in this paper for application in the Scramjet inlet of an air-breathing propulsion system: 1) In the first approach, the pylon set is installed in the rectangular inlet near the cowl front edge. For a quasi-axisymmetric inlet, a similar set is installed along the Star-shaped forebody axis. This set contains 3 - 4 airfoil-shaped strips or cross-sectional rings depending on the type of inlet. The inlets: rectangular, axisymmetric or star-shaped, are located at different distances from the forebody. Fuel injection takes place through these pylons, which provides for uniform mixing downstream. The locations, sizes and angles of these pylons are very important for efficient application. Optimal values of geometrical parameters were determined from multi-parametric NSE-based numerical simulations of the laminar and turbulent external/internal flows. These simulations have shown significant benefits for mixing, combustion and thrust of the proposed approach by comparison with traditional well-known designs. Experimental tests will be conducted soon at the NASA LaRC and Institute of Mechanics at Moscow State University. Preliminary estimates are very promising.

Gilinsky, M.↗

The Sensitivity of Simulated Storm Structure and Intensity to the Temperature at the Lifted Condensation Level

Prior parameter space studies of simulated deep convection are extended to embrace variations in the ambient temperature at the Lifted Condensation Level (LCL). Within the context of the parameter space study design, changes in LCL temperature are roughly equivalent to changes in the ambient precipitable water. Two series of simulations are conducted, one with a warm LCL that is associated with approximately 60 mm of precipitable water, and another with LCL temperatures 8 C cooler, so that PW is reduced to roughly 30 mm. The sets of simulations include tests of the impact of changes in the buoyancy and shear profile shapes and of changes in mixed and moist layer depths, all of which have been shown to be important in prior work. Simulations discussed here feature values of bulk convective available potential energy (CAPE) of 800, 2000, or 3200 Joules per kilogram, and a single semicircular hodograph having radius of 12 meters per second, but with variable vertical shear. The simulations reveal a consistent trend toward stronger peak updraft speeds for the cooler LCL temperature (reduced PW) cases, if all other environmental parameters are held constant. Roughly comparable increases in updraft speeds are noted for all combinations of LCL and level of free convection heights. These increases in updraft strength are evidently the result of both the reduction of condensate loading aloft and the lower altitudes at which the latent heat release by freezing and deposition commences in the cooler, low-PW environments. Because the latent heat of fusion adds relatively more energy to the updrafts at low CAPE, those storms show more strengthening at low PW than do the larger CAPE storms. As expected, maximum storm precipitation rates tend to diminish as PW is decreased, but only slightly, and by amounts not proportionate to the decrease in PW. The low-PW cases thus actually feature larger environment-relative precipitation efficiency than do the high-PW cases. In addition, more hail reaches the surface in the low-PW cases because of reduced melting in the cooler environments.

McCaul, Eugene W., Jr.↗

Two Stage Supersonic Inlet (TSSI):10-inch Model Calculations

The bifurcated inlet examined in this study (which is one of several being considered in the High Speed Research (HSR) Program) was chosen based upon paper trade studies of axisymmetric, single sided, and bifurcated inlets. For a given compression ratio and mass flow a bifurcated inlet weighs less than a single sided inlet. An axisymmetric inlet has less bleed requirements than 2D inlets but has trouble matching transonic airflow requirements without going to a variable diameter centerbody. The bifurcated inlet was selected as one of the candidates because of its ability to match airflow schedules. The inlet examined in this study, the Two Stage Supersonic Inlet (TSSI), was a candidate mixed compression bifurcated inlet. It has a novel concept to aid in inlet stability. This concept was tested in the 10x10 wind tunnel at NASA Glenn. CFD tools were used to predict and interpret the experimental results.

Chapman, Dave↗

Radiation Shielding of Lunar Regolith/Polyethylene Composites and Lunar Regolith/Water Mixtures

Space radiation is a complex mixed field of ionizing radiation that can pose hazardous risks to sophisticated electronics and humans. Mission planning for lunar exploration and long duration habitat construction will face tremendous challenges of shielding against various types of space radiation in an attempt to minimize the detrimental effects it may have on materials, electronics, and humans. In late 2009, the Lunar Crater Observation and Sensing Satellite (LCROSS) discovered that water content in lunar regolith found in certain areas on the moon can be up to 5.6 +/-2.8 weight percent (wt%) [A. Colaprete, et. al., Science, Vol. 330, 463 (2010). ]. In this work, shielding studies were performed utilizing ultra high molecular weight polyethylene (UHMWPE) and aluminum, both being standard space shielding materials, simulated lunar regolith/ polyethylene composites, and simulated lunar regolith mixed with UHMWPE particles and water. Based on the LCROSS findings, radiation shielding experiments were conducted to test for shielding efficiency of regolith/UHMWPE/water mixtures with various percentages of water to compare relative shielding characteristics of these materials. One set of radiation studies were performed using the proton synchrotron at the Loma Linda Medical University where high energy protons similar to those found on the surface of the moon can be generated. A similar experimental protocol was also used at a high energy spalation neutron source at Los Alamos Neutron Science Center (LANSCE). These experiments studied the shielding efficiency against secondary neutrons, another major component of space radiation field. In both the proton and neutron studies, shielding efficiency was determined by utilizing a tissue equivalent proportional counter (TEPC) behind various thicknesses of shielding composite panels or mixture materials. Preliminary results from these studies indicated that adding 2 wt% water to regolith particles could increase shielding of the regolith materials by about 6%. The findings may be utilized to extend the possibilities of potential candidate materials for lunar habitat structures, will potentially impact the design criteria of future human bases on the moon, and provide some guidelines for future space mission planning with respect to radiation exposure and risks posed on astronauts.

Johnson, Quincy F.↗

Evaluation of Electrochemically Generated Potable Water Disinfectants for Use on the International Space Station

Microbial contamination and subsequent growth in spacecraft water systems are constant concerns for missions involving human crews. The current potable water disinfectant is iodine; however, with the end of the Space Shuttle program, there is a need to develop redundant biocide systems which are less dependent on hardware that would need to be launched on a regular basis. Three systems for electrochemical production of potable water disinfectants are being assessed for use on the International Space Station (ISS). Since there is a wide variability in the literature with regards to efficacy in both concentration and exposure time of these disinfectants, there is a need to establish baseline efficacy values. This paper describes a series of tests performed in order to establish optimal concentrations and exposure times for four disinfectants against single and mixed species planktonic and biofilm bacteria and to determine whether these electrochemical disinfection devices are able to produce a sufficient amount of chemical in both concentration and volume to act as a biocide for potable water on ISS.

Vega, Leticia↗

Subsurface Cl-bearing salts as potential contributors to recurring slope lineae (RSL) on Mars

We report laboratory experimental results that support a brine-related hypothesis for the recurring slope lineae (RSL) on Mars in which the subsurface Cl-salts, i.e., hydrous chlorides and oxychlorine salts (HyCOS) are the potential source materials. Our experiments revealed that within the observed RSL temperature window TRSL (250–300 K), the deliquescence of HyCOS could occur in relative humidity ranges (RH≥22%–46%) much lower than those for hydrous (Mg, Fe)-sulfates (RH≥75%–96%). In addition, we demonstrated that the RH values kept by common HyCOS and hydrous sulfates in enclosures have a general trend as RH(sulfates) > RH(perchlorates) > RH(chlorides) (with same type of cation) in wide T range. It means that the required RH range for a Cl-bearing salt to deliquescence can be satisfied by a co-existing salt of different type, e.g., in the subsurface layers of mixed salts on Mars. Furthermore, we found a strong temperature dependence of the deliquescence rates for all tested HyCOS, e.g., a duration of 1–5 sols for all HyCOS at the high end (300 K) of TRSL, and of 20–70 sols for all tested HyCOS (except NaClO4·H2O) at the low end (250 K) of TRSL, which is consistent with the observed seasonal behavior of RSL on Mars. From a mass-balance point of view, the currently observed evidences on Mars do not support a fully-brine-wetted track model, thus we suggest a brine-triggered granular-flow model for the most RSL. Considering the recurrence of RSL in consecutive martian years, our experimental results support the rehydration of remnant HyCOS layers during a martian cold season through H2O vapor-to-salt direct interaction. We found that the evidences of HyCOS rehydration under Mars relevant P-T-RH conditions are detectable in a few minutes by in situ Raman spectroscopy. This rehydration would facilitate the recharge of H2O back into subsurface HyCOS, which could serve as the source material to trigger RSL in a subsequent warm season. The major limiting factor for this rehydration is the H2O supply, i.e., the H2O vapor density carried by current Mars atmospheric circulation and the diffusion rate of H2O vapor into the salt-rich subsurface in a cold season. In a worst-case scenario, these H2O supplies can support a maximum increase of hydration degrees of two for totally dehydrated HyCOS, whereas the full rehydration of subsurface HyCOS layers can be easily reached during a>30° obliquity period that has H2O vapor density 10× to 20× times the value of current obliquity. Overall, our results imply the existence of a large amount of Cl-bearing salts in the subsurface at RSL sites.

Alian Wang↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design.

42 ENGINEERING↗

Qualification of ANSI/HPS N13.1-2011 Mixing Criteria by Computational Fluid Dynamics Modeling for the 3430 Building Fan Addition and Increased Ventilation Capacity

Additional ventilation capacity has been designed for the 3430 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and include new ductwork with a larger diameter to integrate the new fan into the existing stack. Stack operations will involve running various fan combinations at any given time. The air monitoring system of the existing two-fan stack previously was found to comply with the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard. Full-scale, three-dimensional computational fluid dynamics (CFD) modeling was used to evaluate the modified three-fan system for compliance with the ANSI/HPS N13.1-2011 standard, which essentially is equivalent to the ANSI/HPS N13.1-1999 standard. The four mixing criteria evaluated are 1) flow angle, 2) velocity, 3) gas tracer, and 4) particle tracer. Benchmarking of the CFD modeling methodology showed good agreement with previous testing used to qualify the stack, and modeling of the existing two-fan system showed good agreement with test data collected from the 3430 Building stack. Modeling was performed to develop a suitable three-fan design. Initial modeling of the three-fan design and basic ductwork showed that flow angles and velocity uniformity were acceptable; however, the gas tracer and particle tracer mixing results were not acceptable. To meet ANSI/HPS N13.1-2011 criteria, an air blender was added to the stack design. This revision models the individual maximum fan reduced flow capacity from 38,000 cfm to 31,200 cfm; no changes to the duct design are made.

42 ENGINEERING↗

Modeling atomically mixed graded density impactors

Graded density impactors (GDIs) are multi-material composite impactors used in gas gun experiments to tailor the drive conditions imparted to a sample test material. Previous graded density impactors generally rely on thin, but discrete, layers of different materials. The thinner and the greater number of layers will result in smoother compression. Taken to the limit of very thin layers would be pure material 1 at one surface, such as the front surface of an impactor, smoothly transitioning at the atomic scale to pure material 2 on the back surface. Such an impactor can initially shock, then smoothly compresses a material during a dynamic experiment. This type of experiment can serve to explore a larger region of thermodynamic space than a single or even multi-shock experiments. An overview of how graded density impactors are made is reviewed and sample results are given. Additionally, a strategy for modeling these kinds of impactors is presented. The length scales of constituent mixing are given from the experimental build through electrochemical-deposition. Equation of state models for pure constituents and their subsequent mixtures are presented. It is demonstrated that the time scales for pressure and temperature equilibration, for atomically mixed GDIs, are short enough to be a justifiable closure for the resulting multiphase flow. Furthermore, we present simulation results of dynamic shock followed by a ramp compression, utilizing a silver/gold graded density impactor, onto a tantalum sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RELAP5-3D Modeling of High Temperature Test Facility (HTTF) Test PG-26

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors with prismatic fuel and reflector blocks. Several tests have been completed, and more are still planned to at the HTTF, including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This report analyses test PG-26, a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC. PG-26 has been performed at the HTTF between May 30 and June 30, 2019. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heaters. The DCC transient was initiated during the 50 th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test. Version 4.4.2ie of the RELAP5-3D computer code has been used to model the HTTF PG-26 test, and results have been compared to available high-quality measured data. The model used in this study is the quality-controlled HTTF RELAP5-3D model (HTTF base 2018-04-19 QA), originally developed by P. Bayless. The report includes RELAP5-3D results of the “base calculations” as well as some sensitivities to important uncertain model inputs, such as primary helium mass flow rate, core ceramic thermal properties, as well as heat evacuation and loop friction models. Using the base RELAP5-3D model predicts a countercurrent helium flow in the hot duct observed at the beginning of the DCC, but instead of going into a molecular diffusion mode, the model predicts the onset of natural convection. Increasing friction in the core and hot duct prevents the natural convection from happening in some of the simulations. Although some temperatures are well predicted (and even overpredicted), the general tendency is to underpredict the ceramic and helium temperatures and heat removal rates during the DCC, resulting in many of the assessment findings being in minimal or insufficient agreement with the data. It is worth noting that the described discrepancies between measured data and RELAP5-3D predictions are not RELAP5-3D code limitations. More so, they reflect limitations in boundary condition and thermal property knowledge. While the RELAP5-3D calculations of the test provide some insights into what happens during the transient, and point to missing or potentially uncertain data to which the experimenters can direct their attention, the principal conclusion is that the PG-26 test data are insufficient for a system code assessment.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling of HTTF test PG-26 using RELAP5-3D and SAM

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a scaled integral effects experiment designed to investigate transient behavior in high-temperature gas-cooled nuclear reactors (HTGR) with prismatic fuel and reflector blocks [1]. Several tests have been completed at the HTTF including depressurized conduction cooldown (DCC) and pressurized conduction cooldown (PCC) transients. This summary reports on the analysis of test PG-26 using the INL system code REALP5-3D [2] as well as the ANL system code SAM [3]. Test PG-26 is a progression of the Double Ended Inlet-Outlet Crossover Duct Break transient that is referred to as a DCC [4]. Core initial conditions (i.e., before the DCC started) have been met using low power (<100 kW) and two of ten available electric heater banks. The DCC transient was initiated during the 50th hour of the test. The break valves were opened, and hot helium from the core and cold helium from the reactor cavity simulation tank (RCST) started mixing. The gases flowed in a countercurrent fashion, where the top half of the hot duct contained hot helium that flowed in one direction and cold helium that flowed in the other direction in the bottom half of the duct. After the pressure and density reached equilibrium, the event entered a diffusion mode. The onset of a reverse natural circulation was not observed during the DCC period of the test.

97 MATHEMATICS AND COMPUTING↗

Low frost-point humidity generator

A low frost-point humidity generator has been developed at NBS to provide a capability for calibration, testing, and research at very low levels of water vapor content in such gases as atmospheric air, carbon dioxide and nitrogen. The generator produces frost points from -30 to -100 C at ambient pressures from 500 to 200,000 pascals (0.005 to 2 atm.). This is equivalent to mixing ratios of 4 micrograms to 51 grams of water vapor per kilogram of dry air and to vapor pressures of .0014 to 38 pascals. The generated test gas can be fed to a test chamber with independent temperature control between +25 and -100 C. The uncertainty of the frost point in the test chamber is estimated not to exceed 0.05 deg C.

Greenspan, L.↗