Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

High contrast imaging and thickness determination of graphene with in-column secondary electron microscopy

We report a new method for quantitative estimation of graphene layer thicknesses using high contrast imaging of graphene films on insulating substrates with a scanning electron microscope. By detecting the attenuation of secondary electrons emitted from the substrate with an in-column low-energy electron detector, we have achieved very high thickness-dependent contrast that allows quantitative estimation of thickness up to several graphene layers. The nanometer scale spatial resolution of the electron micrographs also allows a simple structural characterization scheme for graphene, which has been applied to identify faults, wrinkles, voids, and patches of multilayer growth in large-area chemical vapor deposited graphene. We have discussed the factors, such as differential surface charging and electron beam induced current, that affect the contrast of graphene images in detail.

36 MATERIALS SCIENCE↗

Understanding Degradation Mechanisms in SrIrO 3 Oxygen Evolution Electrocatalysts: Chemical and Structural Microscopy at the Nanoscale

Designing acid-stable oxygen evolution reaction electrocatalysts is key to developing sustainable energy technologies such as polymer electrolyte membrane electrolyzers but has proven challenging due to the high applied anodic potentials and corrosive electrolyte. This work showcases advanced nanoscale microscopy techniques supported by complementary structural and chemical characterization to develop a fundamental understanding of stability in promising SrIrO 3 thin film electrocatalyst materials. Cross-sectional high-resolution transmission electron microscopy illustrates atomic-scale bulk and surface structure, while secondary ion mass spectrometry imaging using a helium ion microscope provides the nanoscale lateral elemental distribution at the surface. After accelerated degradation tests under anodic potential, the SrIrO 3 film thins and roughens, but the lateral distribution of Sr and Ir remains homogeneous. A layer-wise dissolution mechanism is hypothesized, wherein anodic potential causes the IrO x -rich surface to dissolve and be regenerated by Sr leaching. Finally, the characterization approaches utilized herein and mechanistic insights into SrIrO 3 are translatable to a wide range of catalyst systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental metrology to obtain thermal phonon transmission coefficients at solid interfaces

Interfaces play an essential role in phonon-mediated heat conduction in solids, impacting applications ranging from thermoelectric waste heat recovery to heat dissipation in electronics. From the microscopic perspective, interfacial phonon transport is described by transmission coefficients that link vibrational modes in the materials composing the interface. But, direct experimental determination of these coefficients is challenging because most experiments provide a mode-averaged interface conductance that obscures the microscopic detail. Here, we report a metrology to extract thermal phonon transmission coefficients at solid interfaces using ab initio phonon transport modeling and a thermal characterization technique, time-domain thermoreflectance. In combination with transmission electron microscopy characterization of the interface, our approach allows us to link the atomic structure of an interface to the spectral content of the heat crossing it. This work provides a useful perspective on the microscopic processes governing interfacial heat conduction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Molybdenum work function determined by electron emission microscopy.

A polycrystalline molybdenum sample was recrystallized and thermally stabilized. Quantitative measurements of the emission from each individual grain were obtained with an electron emission microscope. The effective work function for each grain was then calculated. The crystallographic orientation of each grain was determined by Laue back-reflection techniques. A polar plot of effective work function vs crystallographic orientation for the sample was constructed to provide a correlation between effective work function and crystallographic orientation.

Jacobson, D. L.↗

Application of quantitative microscopy to ceramics

Case studies were made of the graphite structures in cast iron. The form, size, distribution, and direction of the structures are described. Microscopic and stereoscopic techniques are discussed.

Kondo, Y.↗

Production of otoconia in the endolymphatic sac in the Japanese red-bellied newt, Cynops pyrrhogaster: light and transmission electron microscopic study

The formation of otoconia in the endolymphatic sac (ES) of the larval newt, Cynops pyrrhogaster, has been studied by light and transmission electron microscopy. Some of the epithelial cells of the ES contain an abundance of swollen vesicles, Golgi complexes, rough endoplasmic reticula and ribosomes at the late larval stages 50 and 51, approximately 26-30 days after eggs are laid. Five days later, at stage 52, crystals are present in the vacuoles between the epithelial cells. Serial sections indicate that these vacuoles actually form small canals which lie in the wall and join the lumen of the ES. Reconstruction of the ES shows that several canals are contained in the ES wall. At stage 56, about 72 days after eggs are laid, a large number of otoconia are present in the ES lumen, while the otoconia disappear from the canals. It appears that the otoconia are first produced in the canals and then released to the lumen. Some epithelial cells of the ES are thought to expel the organic and inorganic material to the canals to form the otoconia in situ. The process of formation of the otoconia in the ES is discussed.

Non-NASA Center↗

Discovery: Under the Microscope at Kennedy Space Center

The National Aeronautics & Space Administration (NASA) is known for discovery, exploration, and advancement of knowledge. Since the days of Leeuwenhoek, microscopy has been at the forefront of discovery and knowledge. No truer is that statement than today at Kennedy Space Center (KSC), where microscopy plays a major role in contamination identification and is an integral part of failure analysis. Space exploration involves flight hardware undergoing rigorous "visually clean" inspections at every step of processing. The unknown contaminants that are discovered on these inspections can directly impact the mission by decreasing performance of sensors and scientific detectors on spacecraft and satellites, acting as micrometeorites, damaging critical sealing surfaces, and causing hazards to the crew of manned missions. This talk will discuss how microscopy has played a major role in all aspects of space port operations at KSC. Case studies will highlight years of analysis at the Materials Science Division including facility and payload contamination for the Navigation Signal Timing and Ranging Global Positioning Satellites (NA VST AR GPS) missions, quality control monitoring of monomethyl hydrazine fuel procurement for launch vehicle operations, Shuttle Solids Rocket Booster (SRB) foam processing failure analysis, and Space Shuttle Main Engine Cut-off (ECO) flight sensor anomaly analysis. What I hope to share with my fellow microscopists is some of the excitement of microscopy and how its discoveries has led to hardware processing, that has helped enable the successful launch of vehicles and space flight missions here at Kennedy Space Center.

Howard, Philip M.↗

Multispecies Biofilms Transform Selenium Oxyanions into Elemental Selenium Particles: Studies Using Combined Synchrotron X-ray Fluorescence Imaging and Scanning Transmission X-ray Microscopy

Selenium (Se) is an element of growing environmental concern, because low aqueous concentrations can lead to biomagnification through the aquatic food web. Biofilms, naturally occurring microbial consortia, play numerous important roles in the environment, especially in biogeochemical cycling of toxic elements in aquatic systems. The complexity of naturally forming multispecies biofilms presents challenges for characterization because conventional microscopic techniques require chemical and physical modifications of the sample. Here, multispecies biofilms biotransforming selenium oxyanions were characterized using X-ray fluorescence imaging (XFI) and scanning transmission X-ray microscopy (STXM). These complementary synchrotron techniques required minimal sample preparation and were applied correlatively to the same biofilm areas. Sub-micrometer XFI showed distributions of Se and endogenous metals, while Se K-edge X-ray absorption spectroscopy indicated the presence of elemental Se (Se0). Nanoscale carbon K-edge STXM revealed the distributions of microbial cells, extracellular polymeric substances (EPS), and lipids using the protein, saccharide, and lipid signatures, respectively, together with highly localized Se0 using the Se LIII edge. Transmission electron microscopy showed the electron-dense particle diameter to be 50–700 nm, suggesting Se0 nanoparticles. The intimate association of Se0 particles with protein and polysaccharide biofilm components has implications for the bioavailability of selenium in the environment.

Yang, Soo In↗

Spectral imaging of single molecules by transmission grating-based epi-fluorescencs microscopy

A spectral imaging method of single protein molecules labeled with a single fluorophore is presented. The method is based on a transmission grating and a routine fluorescence microscope. The bovine serum albumin (BSA) and antiBSA molecules labeled with Alexa Fluor 488 and Alexa Fluor 594, respectively, are used as the model proteins. The fluorescence of single molecules is dispersed into zeroth-order spectrum and first-order spectrum by the transmission grating. Results show that the fluorescence emission spectrum of single molecule converted from the first-order spectral imaging is in good agreement with the bulk fluorescence spectrum. The spectral resolution of 2.4 nm/pixel is obtained, which is sufficient for identifying the molecular species in a multicomponent system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transmission electron microscopy with in-situ ion irradiation: Facilities and community

Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental understanding of the mechanisms which drive changes in materials important to nuclear fission and fusion energy, the semiconductor industry, quantum information systems, space travel, astronomy, geology and many more applications. As these areas continue to evolve and the instrumentation possibilities expand, the capacity of in-situ ion irradiation facilities must also develop hand-in-hand with the user community to deliver an ever-greater diversity of high-fidelity extreme-environment experimentation. Future directions for the field, such as miniaturization from MEMS/microfluidic devices and advanced controls with ML-based analysis, continuously emerge to advance both the hardware and software which support the coupling of TEMs with ion beams. This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities which have the potential to further unlock access to the nanoscale exploration of coupled extreme environments crucial to many of the important science and engineering challenges we face today.

In-situ irradiation↗

Real-Time and Post-Reaction Microscopic Structural Analysis of Biomass Undergoing Pyrolysis

The structural complexity of unprocessed plant tissues used for thermochemical conversion of biomass to fuels and energy impedes heat and mass transfer and may increase the occurrence of tar-forming secondary chemical reactions. At industrial scales, gas and liquid products trapped within large biomass particles may reduce net fuel yields and increase tars, impacting industrial operations and increasing overall costs. Real-time microscopic analysis of poplar (Populus sp.) wood samples undergoing anoxic, pyrolytic heat treatment has revealed a pattern of tissue and macropore expansion and collapse. Post-reaction structural analyses of biomass char (biochar) by light and transmission electron microscopy have provided direct structural evidence of pyrolysis product mass-transfer issues, including trapped pyrolysis products and cell wall compression, and have demonstrated the impact of heat-transfer problems on biomass particles. Finally, microscopic imaging has revealed that pyrolyzed/gasified biochars recovered from a fluidized bed reactor retain a similar pre-reaction basic plant tissue structure as the samples used in this study, suggesting that the phenomena observed here are representative of those that occur in larger scale reactors.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

A Roadmap for Edge Computing Enabled Automated Multidimensional Transmission Electron Microscopy

The advent of modern, high-speed electron detectors has made the collection of multidimensional hyperspectral transmission electron microscopy datasets, such as 4D-STEM, a routine. However, many microscopists find such experiments daunting since analysis, collection, long-term storage, and networking of such datasets remain challenging. Some common issues are their large and unwieldy size that often are several gigabytes, non-standardized data analysis routines, and a lack of clarity about the computing and network resources needed to utilize the electron microscope. The existing computing and networking bottlenecks introduce significant penalties in each step of these experiments, and thus, real-time analysis-driven automated experimentation for multidimensional TEM is challenging. One solution is to integrate microscopy with edge computing, where moderately powerful computational hardware performs the preliminary analysis before handing off the heavier computation to high-performance computing (HPC) systems. In this work, we trace the roots of computation in modern electron microscopy, demonstrate deep learning experiments running on an edge system, and discuss the networking requirements for tying together microscopes, edge computers, and HPC systems.

47 OTHER INSTRUMENTATION↗

Preparation and characterization of bifunctional dendrimer modified Fe{sub 3}O{sub 4}/CdTe nanoparticles with both luminescent and superparamagnetic properties

Highlights: • The fluorescent superparamagnetic dendrimeric Fe{sub 3}O{sub 4}/CdTe nanoparticles are synthesized in this paper. • The synthesized nanocomposites maintain excellent magnetic properties. • The synthesized nanocomposites maintain highly luminescent markers with narrow emission bands. - Abstract: Magnetic nanoparticles Fe{sub 3}O{sub 4} were prepared by hydrothermal coprecipitation of ferric and ferrous ions using NaOH. The surface modification of Fe{sub 3}O{sub 4} nanoparticle by dendrimers has rendered the nanoparticle surface with enriched amine groups which facilitated the adsorption and conjugation of thioglycolic acid (TGA) modified CdTe quantum dots to form a stable hybrid nanostructure. Three generations (first generation: G0F, second generation: G1F, third generation: G3F) of bifunctional dendrimeric Fe{sub 3}O{sub 4}/CdTe nanoparticles were successfully prepared using this technique and characterized by microscopy. The optical and magnetic properties of the dendrimeric Fe{sub 3}O{sub 4}/CdTe nanoparticle were also investigated. The microscopic study reveals 3 different sizes for 3 generations, 16 nm (G0F), 31 nm (G1F) and 47 nm (G3F). Among three generations of nanoparticles, the G1F has the best optical property with a luminescent quantum yield of 25.6% and the G0F has the best magnetic property with a saturation magnetization of 19.3 emμ/g.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Germination, growth rates, and electron microscope analysis of tomato seeds flown on the LDEF

The tomato seeds were flown in orbit aboard the Long Duration Exposure Facility (LDEF) for nearly six years. During this time, the tomato seeds received an abundant exposure to cosmic radiation and solar wind. Upon the return of the LDEF to earth, the seeds were distributed throughout the United States and 30 foreign countries for analysis. The purpose of the experiment was to determine the long term effect of cosmic rays on living tissue. Our university analysis included germination and growth rates as well as Scanning Electron Microscopy and X-ray analysis of the control as well as Space-exposed tomato seeds. In analyzing the seeds under the Electron Microscope, usual observations were performed on the nutritional and epidermis layer of the seed. These layers appeared to be more porous in the Space-exposed seeds than on the Earth-based control seeds. This unusual characteristic may explain the increases in the space seeds growth pattern. (Several test results show that the Space-exposed seeds germinate sooner than the Earth-Based seeds. Also, the Space-exposed seeds grew at a faster rate). The porous nutritional region may allow the seeds to receive necessary nutrients and liquids more readily, thus enabling the plant to grow at a faster rate. Roots, leaves and stems were cut into small sections and mounted. After sputter coating the specimens with Argon/Gold Palladium Plasma, they were ready to be viewed under the Electron Microscope. Many micrographs were taken. The X-ray analysis displayed possible identifications of calcium, potassium, chlorine, copper, aluminum, silicon, phosphate, carbon, and sometimes sulfur and iron. The highest concentrations were shown in potassium and calcium. The Space-exposed specimens displayed a high concentration of copper and calcium in the two specimens. There was a significantly high concentration of copper in the Earth-based specimens, whereas there was no copper in the Space-exposed specimens.

Hammond, Ernest C., Jr.↗

Electric field stimulation setup for photoemission electron microscopes

Manipulating magnetisation by the application of an electric field in magnetoelectric multiferroics represents a timely issue due to the potential applications in low power electronics and the novel physics involved. Thanks to its element sensitivity and high spatial resolution, X-ray photoemission electron microscopy is a uniquely suited technique for the investigation of magnetoelectric coupling in multiferroic materials. In this work, we present a setup that allows for the application of in situ electric and magnetic fields while the sample is analysed in the microscope. As an example of the performances of the setup, we present measurements on Ni/Pb(Mg{sub 0.66}Nb{sub 0.33})O{sub 3}-PbTiO{sub 3} and La{sub 0.7}Sr{sub 0.3}MnO{sub 3}/PMN-PT artificial multiferroic nanostructures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In-situ piezoresponse force microscopy cantilever mode shape profiling

The frequency-dependent amplitude and phase in piezoresponse force microscopy (PFM) measurements are shown to be a consequence of the Euler-Bernoulli (EB) dynamics of atomic force microscope (AFM) cantilever beams used to make the measurements. Changes in the cantilever mode shape as a function of changes in the boundary conditions determine the sensitivity of cantilevers to forces between the tip and the sample. Conventional PFM and AFM measurements are made with the motion of the cantilever measured at one optical beam detector (OBD) spot location. A single OBD spot location provides a limited picture of the total cantilever motion, and in fact, experimentally observed cantilever amplitude and phase are shown to be strongly dependent on the OBD spot position for many measurements. In this work, the commonly observed frequency dependence of PFM response is explained through experimental measurements and analytic theoretical EB modeling of the PFM response as a function of both frequency and OBD spot location on a periodically poled lithium niobate sample. One notable conclusion is that a common choice of OBD spot location—at or near the tip of the cantilever—is particularly vulnerable to frequency dependent amplitude and phase variations stemming from dynamics of the cantilever sensor rather than from the piezoresponse of the sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Understanding batteries on the micro- and nanometer scale

In order to understand performance limitations and failure mechanisms of batteries, one has to investigate processes on the micro- and nanometer scale. A typical failure mechanism in lithium metal batteries is dendritic growth. During discharge, lithium is stripped of the anode surface and migrates to the cathode. During charge, lithium is deposited back on the anode. Repeated cycling can result in stripping and re-deposition that roughens the surface. The roughening of the surface changes the electric field and draws more metal to spikes that are beginning to grow. These can grow with tremendous mechanical force, puncture the separator, and directly connect the anode with the cathode which can create an internal short circuit. This can lead to an uncontrolled discharge reaction, which heats the cell and causes additional exothermic reactions leading to what is called thermal runaway. ORNL has developed a new technology called liquid electron microscopy. In a specially designed sample holder micro-chamber with electron-transparent windows, researchers can hold a liquid and take images of structures and particles at nanometer size. It's the first microscope holder of its kind used to investigate the inside of a battery while cycled.

25 ENERGY STORAGE↗