Metrics for Evaluating the Accuracy of Solar Power Forecasting (Presentation)
This presentation proposes a suite of metrics for evaluating the performance of solar power forecasting.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This presentation proposes a suite of metrics for evaluating the performance of solar power forecasting.
Supervisory Control and Data Acquisition (SCADA) systems are distributed networks dispersed over large geographic areas that aim to monitor and control industrial processes from remote areas and/or a centralized location. They are used in the management of critical infrastructures such as electric power generation, transmission and distribution, water and sewage, manufacturing/industrial manufacturing as well as oil and gas production. The availability of SCADA systems is tantamount to assuring safety, security and profitability. SCADA systems are the backbone of the national cyber-physical critical infrastructure. Herein, we explore the definition and quantification of an econometric measure of availability, as it applies to SCADA systems; our metric is a specialization of the generic measure of mean failure cost.
As the penetration of variable generation (wind and solar) increases around the world, there is an accompanying growing interest and importance in accurately assessing the contribution that these resources can make toward planning reserve. This contribution, also known as the capacity credit or capacity value of the resource, is best quantified by using a probabilistic measure of overall resource adequacy. In recognizing the variable nature of these renewable resources, there has been interest in exploring the use of reliability metrics other than loss of load expectation. In this paper, we undertake some comparisons using data from the Western Electricity Coordinating Council in the western United States.
As the penetration of variable generation (wind and solar) increases around the world, there is an accompanying growing interest and importance in accurately assessing the contribution that these resources can make toward planning reserve. This contribution, also known as the capacity credit or capacity value of the resource, is best quantified by using a probabilistic measure of overall resource adequacy. In recognizing the variable nature of these renewable resources, there has been interest in exploring the use of reliability metrics other than loss of load expectation. In this paper, we undertake some comparisons using data from the Western Electricity Coordinating Council in the western United States.
Life cycle assessment (LCA) is a method for assessing all environmental impacts associated with provisioning a good or service. A life cycle encompasses the system which directly produces a good, as well as all systems and processes on which that system is dependent. The objective of this work is to develop a flexible, parameterized model representing a superstructure of life cycles for advanced biofuel production. Parameterizing the model allows users to define a variety of biofuel production scenarios and assess key sustainability metrics, without needing to acquire additional data or perform separate life cycle assessments. Within the model, parameters will include feedstock species and phenotype, a range of farming and harvest practices, feedstock pre-processing, and operating conditions within the biomass conversion process. The model will be used to identify major impact drivers within bioenergy life cycles and aid CBI researchers and leadership in targeting areas where additional R&D efforts will have the most beneficial impacts.
Final Metrics Report for the Sustainable Solar Education Project
This poster provides an overview of quasi-static time-series PV hosting capacity methodology and metrics.
Historic Measurement with up to 3 Metric Tons of Weapons Grade HEU Metal
North American energy codes do not typically discriminate between high-performing and poorly-performing HVAC system types, thereby perpetuating the installation of systems with high energy consumption and carbon emissions. The problem is compounded in the US by federal preemption rules, prohibiting state and local energy codes from mandating more efficient equipment than is defined in federal standards. The lack of a total system efficiency metric for HVAC effectively blocks an eventual transition to a performance-based code structure. To surmount this problem, the City of Seattle and Pacific Northwest National Laboratory have developed the Total System Performance Ratio (TSPR) as a proposed amendment to the 2018 Washington State Energy Code. The TSPR is a ratio that compares the annual space heating and cooling load of a building to the annual energy consumed by the building’s entire HVAC system. In the TSPR, target ratios for several building types are calculated in relation to those of the HVAC systems judged to be the most appropriate for each building type. Installation of the lowest-performing HVAC system types will be severely constrained, while exceptional design flexibility will still be provided. With financial support from an international nonprofit, a calculation software tool has been developed as a module of the US DOE Asset Score tool, using simplified building energy modeling. Taken together with whole-system evaluation options for lighting and building envelope systems, a whole-system HVAC performance evaluation would create a path for a transition away from prescriptive-based and towards performance-based codes.
Community and city leaders are interested in achieving sustainability goals, providing resilient energy infrastructure, and improving economic competitiveness. Community-level data acquisition and analysis can provide energy and associated benefits that are not possible at the single building level. However, there is a lack of organizational structure, common semantic data models, interoperable systems, and methods to support data-driven decision-making for community-scale energy supply and demand systems. We explored the need and opportunity for a Community Energy Operations and Planning System (Community EOPS), a potential data exchange platform. We conducted “customer discovery” interviews, and reviewed literature, public tools, and technology platforms to identify key energy data “users” and use cases in communities. The key users of the Community EOPS could be developers of mixed-use districts, corporate, defense and university campus energy managers, and city managers of cities that own their energy utility. The value could be for community planning and reporting (for energy data-integrated land use planning and community infrastructure investments in microgrids, storage, district heating and cooling), energy efficiency (leveraging optimizations for community scale energy supply and demand), flexible load management (grid-edge load management to offset, shift, and flatten loads for multiple buildings and EV fleets), cost savings and revenue generation (participating in grid services), and social benefits such as energy resilience, equity, and awareness. We developed a conceptual Community EOPS architecture with recommendations for streamlined and prioritized data acquisition, sharing, and integration driven by prioritized use cases, common metrics, and actionable visualizations that can provide value to a community’s users.
Performance evaluation methods, including hardware-in-the-loop, metrics, and additional considerations relevant to validating microgrid controller performance in the context of microgrid co-design are presented.
This fact sheet summarizes the demand, challenges, and opportunities for developing and incorporating energy risk metrics in the commercial mortgage underwriting process.
Determination of an adequate level of security and providing subsequent mechanisms to achieve it, is one of the most pressing problems regarding embedded computing devices. While there are some solutions available for resource-rich computer systems, direct application of these solutions to resource-constrained environments are often unfeasible. The fundamental problem for such resource-constrained systems is the fact that current cryptographic algorithms utilize significant energy consumption and storage overhead. Both the cryptographic algorithm and its physical implementation affect the resilience of a cryptosystem against side-channel attacks. A side-channel attack represents a process that exploits leakages in order to extract sensitive information such as the key. This paper focuses on Correlation Power Analysis (CPA) which is side-channel attack based on the power consumption leakage. In 2016 the U.S. Commerce Department’s National Institute of Standards and Technology (NIST) initiated the call for proposals of new cryptographic algorithms to strengthen the cryptographic defense of networked devices against cyberattacks and to protect the data created by those innumerable device. This work evaluates S-boxes used by NIST candidates PICCOLO, GIFT, and PRESENT, as well as several S-box variants that demonstrated sufficient weaknesses against classical cryptanalysis, for a quantitative comparison in terms of resiliency to CPA attack. Three well-known theoretical metrics are evaluated: transparency order (TO and RTO), nonlinearity, and signal-to-noise (SNR) ratio, aiming to characterize the resistance of these S-boxes against adversaries exploiting physical leakages. Experimental results from attacks on an 8- bit XMEGA were obtained via the ChipWhisperer platform and of all the S-boxes evaluated, GIFT64 with a PICCOLO S-box was found to be the most susceptible to CPA. Results showed that variations in TO and RTO were not sufficient to ensure practical CPA resistance and that among S-boxes with equal non-linearity there were no significant differences in the TO and SNR variants.
Determination of an adequate level of security and providing subsequent mechanisms to achieve it, is one of the most pressing problems regarding embedded computing devices. While there are some solutions available for resource-rich computer systems, direct application of these solutions to resource-constrained environments are often unfeasible. The fundamental problem for such resource-constrained systems is the fact that current cryptographic algorithms utilize significant energy consumption and storage overhead. Both the cryptographic algorithm and its physical implementation affect the resilience of a cryptosystem against side-channel attacks. A side-channel attack represents a process that exploits leakages in order to extract sensitive information such as the key. This paper focuses on Correlation Power Analysis (CPA) which is side-channel attack based on the power consumption leakage. In 2016 the U.S. Commerce Department’s National Institute of Standards and Technology (NIST) initiated the call for proposals of new cryptographic algorithms to strengthen the cryptographic defense of networked devices against cyberattacks and to protect the data created by those innumerable device. This work evaluates S-boxes used by NIST candidates PICCOLO, GIFT, and PRESENT, as well as several S-box variants that demonstrated sufficient weaknesses against classical cryptanalysis, for a quantitative comparison in terms of resiliency to CPA attack. Three well-known theoretical metrics are evaluated: transparency order (TO and RTO), nonlinearity, and signal-to-noise (SNR) ratio, aiming to characterize the resistance of these S-boxes against adversaries exploiting physical leakages. Experimental results from attacks on an 8- bit XMEGA were obtained via the ChipWhisperer platform and of all the S-boxes evaluated, GIFT64 with a PICCOLO S-box was found to be the most susceptible to CPA. Results showed that variations in TO and RTO were not sufficient to ensure practical CPA resistance and that among S-boxes with equal non-linearity there were no significant differences in the TO and SNR variants.
Building Energy Use Intensity (EUI) has been commonly used to facilitate policy makers and utilities to design energy efficacy programs and help building managers prioritize investment in building upgrades. Buildings with higher EUIs are usually chosen as better candidates for retrofit. Our study of nearly one hundred buildings in Seattle’s Building Tune Up Accelerator program and thousands of buildings in the Asset Score database reveals that EUI (after weather/location/use type normalization) alone is not the best indicator of a building’s potential to save energy, especially for those buildings in the mid-range (30-70 percentile EUI). In this paper, we introduce the concept of “retrofit-ability” — a building’s real potential to reduce its energy use cost-effectively — as a supplementary metric to inform energy efficiency policy and investment. Currently, such potential analyses are predicted for a building stock using prototypical building models or statistical data. However, typical buildings or general historical data may not sufficiently represent building configurations in a portfolio and predict their saving potentials. We utilized machine learning to investigate how key building characteristics (such as envelope attributes, HVAC type, location, use type, etc.) affect a building’s improvement potentials and developed a low-cost method to quantify such potentials for a portfolio of buildings. The supplementary perspective provided by “retrofit-ability” highlights which building assets correlate most with a building’s energy savings potential across region, building use type and more.
While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. One of the difficulties that wave energy systems have been struggling to overcome is the design of highly efficient energy conversion systems that can convert the mechanical power, derived from the oscillation of wave activated bodies, into another useful product. Often the power take-off (PTO) is defined as the single unit responsible for converting mechanical power into another usable form such as electricity, pressurized fluid, compressed air, and others. The PTO, and the entire power conversion chain (PCC), is of great importance as it affects not only how efficient wave power is converted into electricity, but also contributes to the mass, size, structural dynamics, and levelized cost of energy (LCOE) of the wave energy converter (WEC). Unlike wind and solar, there is no industrial standard device, or devices, for wave energy conversion and this diversity is transferred to the PTO system. The majority of current WEC PTO systems incorporate a mechanical or hydraulic drive train, power generator, and an electrical control system. The challenge of WEC PTO designs is designing a mechanical-to-electrical component that can efficiently convert irregular, bi-directional, low frequency and low alternating velocity wave motions. While gross average power levels can be predicted in advance, the variable wave elevation input has to be converted into smooth electrical output and hence usually necessitates some type of energy storage system, such as battery storage, accumulator super capacitors, etc., or other means of compensation such as an array of devices. One of the primary challenges for wave energy converter systems is the fluctuating nature of wave resources, which require WEC components to be designed to handle loads (i.e. torques, forces, and powers) that are many times greater than the average load. This approach requires a much greater PTO capacity than the average power output and indicates a higher cost. In addition, supporting mechanical coupling and or gearing can be added to the PCC to help alleviate the difficulties with transmission and control of fluctuating large loads with low frequencies (indicative of wave forcing) into smaller loads at higher frequencies (optimum for conventional electrical machine design) can quickly increase the complexity of the PCC which could result in a greater number of failure modes and increased maintenance costs. All of the previous points demonstrate how the PTO influences WEC dynamics, reliability, performance and cost which are critical design factors. This paper further explores these topics by providing a review of the state-of-the-art PTO systems currently under development, how these novel PTO systems are tested and derisked prior to precommercial deployment, and the evaluation metrics historically used to differentiate between PTO designs and how they can be improved to support control co-design focused development of wave energy systems.
The purpose of this work is to review and develop life cycle greenhouse gas (GHG) metrics for global crude oil production. The method presented here not only quantifies GHG emissions but also provides a semi-quantitative measure of the quality of data associated with each estimate.
This presentation summarizes the updates for the Mobility Energy Productivity (MEP) metric project over the past fiscal year.