Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement Science Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

3-D Gamma-ray Mapping from Unmanned Aerial Systems for Nuclear Decommissioning - 18439

Advanced gamma-ray detection technologies integrated with sophisticated robotic platforms will enable safer and more cost and time-efficient capabilities in support of nuclear decommissioning, waste management, and environmental remediation activities within the United States Department of Energy (U.S. DOE) complex and in the global nuclear power industry. In the Applied Nuclear Physics program at Lawrence Berkeley National Laboratory, we have developed the Nuclear Scene Data Fusion (SDF) capability to map gamma-ray emitting sources in large-scale, 3-D environments in real-time. This powerful capability has been successfully deployed in real-world environments, from a test-bed in Berkeley, CA to the exclusion zone in Fukushima Prefecture, Japan to support environmental remediation and contamination mapping efforts within evacuated communities, and is also currently being further developed in support of decommissioning efforts at the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) in collaboration with the Japan Atomic Energy Agency (JAEA). In this work, we will provide an overview of SDF adapted for gamma-ray mapping onboard an UAS, as well as results from measurements demonstrating point and distributed source mapping. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mineralogical transformations controlling acid mine drainage chemistry

The role of Fe(III) minerals in controlling acid mine drainage (AMD) chemistry was studied using samples from two AMD sites [Gum Boot (GB) and Fridays-2 (FR)] located in northern Pennsylvania. Chemical extractions, X-ray diffraction (XRD), scanning electron microscopy (SEM), and Fourier transform infrared spectroscopy (FTIR) were used to identify and characterize Fe(III) phases. The mineralogical analysis revealed that schwertmannite and goethite were the principal Fe(III) phases in the sediments. Schwertmannite transformation occurred at the GB site where poorly-crystallized goethite rich in surface-bound sulfate was initially formed. In contrast, no schwertmannite transformation occurred at the FR site. The goethite in GB sediments had spherical morphology due to preservation of schwertmannite structure by adsorbed sulfate. Results of chemical extractions showed that poorly-crystallized goethite was subject to further crystallization accompanied by sulfate desorption. Changes in sulfate speciation preceded its desorption, with a conversion of bidentate- to monodentate-bound sulfate surface complexes. Laboratory sediment incubation experiments were conducted to evaluate the effect of mineral transformation on water chemistry. Incubation experiments were carried out with schwertmannite-containing sediments and AMD waters with different pH and chemical composition. The pH decreased to 1.9-2.2 in all suspensions and the concentrations of dissolved Fe and S increased significantly. Regardless of differences in the initial water composition, pH, Fe and S were similar in suspensions of the same sediment. XRD measurements revealed that schwertmannite transformed into goethite in GB and FR sediments during laboratory incubation. The incubation experiment demonstrated that schwertmannite transformation controlled AMD water chemistry during “closed system” laboratory contact.

54 ENVIRONMENTAL SCIENCES↗

Kinetic Analysis of Competitive Electrocatalytic Pathways: New Insights into Hydrogen Production with Nickel Electrocatalysts

The hydrogen production electrocatalyst Ni(PPh2NPh2)22+ (1) is capable of traversing multiple electrocatalytic pathways. When using dimethylformamidium, DMF(H)+, the mechanism of formation of H2 catalyzed by 1 changes from an ECEC to an EECC mechanism as the potential approaches the Ni(I/0) couple. Two recent electrochemical methods, current-potential analysis and foot-of-the-wave analysis (FOWA), were performed on 1 to measure the detailed chemical kinetics of the competing ECEC and EECC pathways. A sensitivity analysis was performed on the electrochemical methods using digital simulations to gain a better understanding of their strengths and limitations. Notably, chemical rate constants were significantly underestimated when not accounting for electron transfer kinetics, even when electron transfer was fast enough to afford a reversible non-catalytic wave. The EECC pathway of 1 was found to be faster than the ECEC pathway under all conditions studied. Using buffered DMF: DMF(H)+ mixtures led to an increase in the catalytic rate constant (kobs) of the EECC pathway, but kobs for the ECEC pathway did not change when using buffered acid. Further kinetic analysis of the ECEC path revealed that added base increases the rate of isomerization of the exo-protonated Ni(0) isomers to the catalytically active endo-isomers, but decreases the net rate of protonation of Ni(I). FOWA on 1 did not provide accurate rate constants due to incomplete reduction of the exo-protonated Ni(I) intermediate at the foot of the wave, but FOWA could be used to estimate the reduction potential of this previously undetected intermediate. This research was supported as part of the Center for Molecular Electrocatalysis, an Energy Frontier Research Center funded by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences. Pacific Northwest National Laboratory is operated by Battelle for the U.S. Department of Energy.

electrocatalysis↗

Data-optimized source modeling with the Backwards Liouville Test–Kinetic method

In the standard practice of neutron multiplicity counting , the first three sampled factorial moments of the event triggered neutron count distribution were used to quantify the three main neutron source terms: the spontaneous fissile material effective mass, the relative (α,n) production and the induced fission source responsible for multiplication. Our study compares three methods to quantify the statistical uncertainty of the estimated mass: the bootstrap method, propagation of variance through moments, and statistical analysis of cycle data method. Each of the three methods was implemented on a set of four different NMC measurements, held at the JRC-laboratory in Ispra, Italy, sampling four different Pu samples in a standard Plutonium Scrap Multiplicity Counter (PSMC) well counter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Conductivity of G-348 Isostatic Graphite

Fundamental measurements have been obtained to deduce the temperature dependence of thermal conductivity for fine-grain G-348 isostatic graphite, which has been used in thermal experiments related to gas-cooled nuclear reactors. Measurements of thermal diffusivity, mass, volume, and thermal expansion were converted to thermal conductivity. Resulting correlations for the thermal conductivity and thermal expansion are presented as functions of temperature from laboratory temperature to 1000°C.

36 MATERIALS SCIENCE↗

High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.

INS measurements were performed using the Fine Resolution Chopper Spectrometer SEQUOIA at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a CCR was used to cool the sample down to 6 K. Data were collected using fixed incident neutron energies of 100 and 30 meV.

MATERIALS SCIENCE↗

MINER - A Mobile Imager of Neutrons for Emergency Responders

We have developed a mobile fast neutron imaging platform to enhance the capabilities of emergency responders in the localization and characterization of special nuclear material. This mobile imager of neutrons for emergency responders (MINER) is based on the Neutron Scatter Camera, a large segmented imaging system that was optimized for large-area search applications. Due to the reduced size and power requirements of a man-portable system, MINER has been engineered to fit a much smaller form factor, and to be operated from either a battery or AC power. We chose a design that enabled omnidirectional (4π) imaging, with only a ~twofold decrease in sensitivity compared to the much larger neutron scatter cameras. The system was designed to optimize its performance for neutron imaging and spectroscopy, but it does also function as a Compton camera for gamma imaging. This document outlines the project activities, broadly characterized as system development, laboratory measurements, and deployments, and presents sample results in these areas. Additional information can be found in the documents that reside in WebPMIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid-State Neutron Multiplicity Counting System Using Commercial Off-the-Shelf Semiconductor Detectors

This work iterates on the first demonstration of a solid-state neutron multiplicity counting system developed at Lawrence Livermore National Laboratory by using commercial off-the-shelf detectors. The system was demonstrated to determine the mass of a californium-252 neutron source within 20% error requiring only one-hour measurement time with 20 cm 2 of active detector area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density Measurements of Plutonium Bearing Salts via Neutron Beam Dilatometry (Final Report for Gateway for Accelerated Innovation in Nuclear (GAIN) Voucher NE-21-25117)

A novel neutron radiographic technique was developed and implemented to measure the change in volume as a function of temperature of select plutonium-containing liquid chloride mixtures from melt to 1250 K. These measurements were performed at Los Alamos National Laboratory by members of the molten salt research group under support from Gateway for Accelerated Innovation in Nuclear (GAIN) voucher NE-21-25117: “Density Measurements of Plutonium Bearing Salts via Neutron Beam Dilatometry”.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radiation detector

Alpha particle detecting devices are disclosed that have a chamber that can hold a fluid in a tensioned metastable state. The chamber is tuned with a suitable fluid and tension such that alpha emitting materials such as radon and one or more of its decay products can be detected. The devices can be portable and can be placed in areas, such as rooms in dwellings or laboratories and used to measure radon in these areas, in situ and in real time. The disclosed detectors can detect radon at and below 4 pCi/L in air; also, at and below 4,000 pCi/L or 300 pCi/L in water.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of Pulsed-DEER Measurements for Gd-Based Labels: Choice of Operational Frequencies, Pulse Durations and Positions, and Temperature

In this work, the experimental conditions and parameters necessary to optimize the long-distance (≥ 60 Å) Double Electron-Electron Resonance (DEER) measurements of biomacromolecules labeled with Gd(III) tags are analyzed. The specific parameters discussed are the temperature, microwave band, the separation between the pumping and observation frequencies, pulse train repetition rate, pulse durations and pulse positioning in the electron paramagnetic resonance spectrum. It was found that: (i) in optimized DEER measurements, the observation pulses have to be applied at the maximum of the EPR spectrum; (ii) the optimal temperature range for Ka-band measurements is 14-17 K, while in W-band the optimal temperatures are between 6-9 K; (iii) W-band is preferable to Ka-band for DEER measurements. Recent achievements and the conditions necessary for short-distance measurements (<15 Å) are also briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of Botulinum neurotoxin using high-affinity antibodies

A fluorescence sandwich immunoassay using high affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum toxin serotype A (BoNT/A). For the development of the assay, a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) has been used as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader. Detection down to 31 pM of the BoNT/Hc-fragment was demonstrated with a total incubation time of 3 hours, using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the immunochemical reactions were carried out in microcentrifuge tubes with an incubation time of 1 hour. These beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell as part of a sequential injection fluidic system. This flow cell was equipped with a fiber optic system for fluorescence measurements. In PBS buffer solution matrix, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach.

60 APPLIED LIFE SCIENCES↗

Data-driven upper bounds and event attribution for unprecedented heatwaves

The last decade has seen numerous record-shattering heatwaves in all corners of the globe. In the aftermath of these devastating events, there is interest in identifying worst-case thresholds or upper bounds that quantify just how hot temperatures can become. Generalized Extreme Value theory provides a data-driven estimate of extreme thresholds; however, upper bounds may be exceeded by future events, which undermines attribution and planning for heatwave impacts. Here, we show how the occurrence and relative probability of observed yet unprecedented events that exceed a priori upper bound estimates, so-called “impossible” temperatures, has changed over time. We find that many unprecedented events are actually within data-driven upper bounds, but only when using modern spatial statistical methods. Furthermore, there are clear connections between anthropogenic forcing and the “impossibility” of the most extreme temperatures. Robust understanding of heatwave thresholds provides critical information about future record-breaking events and how their extremity relates to historical measurements.

54 ENVIRONMENTAL SCIENCES↗

Parts-Per-Million Carbonate Mineral Quantification with Thermogravimetric Analysis–Mass Spectrometry

Mitigating the deleterious effects of climate change requires the development and implementation of carbon capture and storage technologies. To expand the monitoring, verification, and reporting (MRV) capabilities of geologic carbon mineralization projects, we developed a thermogravimetric analysis–mass spectrometry (TGA–MS) methodology to enable quantification of <100 ppm calcite (CaCO 3 ) in complex samples. We extended TGA–MS calcite calibration curves to enable a higher measurement resolution and lower limits of quantification for evolved CO 2 from a calcite–corundum mixture. We demonstrated <100 ppm carbonate mineral quantification with TGA–MS for the first time, an outcome applicable across earth, environmental, and materials science fields. We applied this carbonate quantification method to a suite of Columbia River Basalt Group (CRBG) well cuttings recovered in 2009 from Pacific Northwest National Laboratory’s Wallula #1 Well. Our execution of this new combined calcite and calcite–corundum calibration curve TGA–MS method on our CRBG sample suite indicated average carbonate contents of 0.050 wt % in flow interiors (caprocks) and 0.400 wt % in interflow zones (reservoirs) in the upper 1250 m of the Wallula #1 Well. Finally, by advancing our knowledge of continental flood basalt-hosted carbonates in the mafic subsurface and reaching new TGA–MS quantification limits for carbonate minerals, we expand MRV capabilities and support the commercial-scale deployment of carbon mineralization projects in the Pacific Northwest United States and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium in Framboidal Pyrite from a Naturally Bioreduced Alluvial Sediment

Samples of a naturally bioreduced, U contaminated aquifer sediment from Rifle, CO were characterized with various microscopic and spectroscopic techniques and wet chemical extraction methods. The objective was to investigate U association and interaction with the soil minerals of the sediment. The naturally bioreduced sediment was elevated in solid-phase U, total organic carbon and acid-volatile sulfide, and depleted in bioavailable Fe(III) indicating that sulfate and Fe(III) reduction have occurred naturally in the sediment. XRD and SEM/EDS analyses demonstrated that framboidal pyrites (FeS2) of different sizes (~10 – 20 μm in diameter), and of various microcrystal morphology, degree of surface weathering and internal porosity were abundant in the < 53 μm fraction (silt+clay) of the sediment. EMP, XRF, EXAFS, and XANES measurements confirmed that U interacted mostly with framboidal pyrite and that both U(VI) and U(IV) were associated with the framboids indicating partial reduction of surface bounded U(VI). Results demonstrated that U(VI) may be sorbed and reduced on framboidal pyrite, and both sorption and reduction were important pathways of U(VI) attenuation in this naturally bioreduced sediment. A fuller understanding of U(VI) fate in this unique system could help in developing remedial measures for other U contaminated aquifers.

54 ENVIRONMENTAL SCIENCES↗

Note: Construction of x-ray scattering and x-ray absorption fine structure beamline at the Pohang Light Source

A new hard x-ray beamline, 10B KIST-PAL beamline (BL10B), has been designed and constructed at the Pohang Light Source (PLS) in Korea. The beamline, operated by Pohang Accelerator Laboratory-Korean Institute of Science and Technology consortium, is dedicated to x-ray scattering (XRS) and x-ray absorption fine structure (XAFS) experiments. X rays with photon energies from 4.0 to 16.0 keV are delivered to the experimental station passing a collimating mirror, a fixed-exit double-crystal Si(111) monochromator, and a toroidal mirror. Basic experimental equipments for XAFS measurement, a high resolution diffractometry, an image plate detector system, and a hot stage have been prepared for the station. From our initial commissioning and performance testing of the beamline, it is observed that BL10B beamline can perform XRS and XAFS measurements successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPLAT II: An Aircraft Compatible, Ultra-Sensitive, High Precision Instrument for In-Situ Characterization of the Size and Composition of Fine and Ultrafine Particles

The properties of aerosols depend on the size and internal compositions of the individual particles. The vast majority of atmospheric aerosols are smaller than 200 nm, yet the single particle mass spectrometers, the only instruments that can characterize the size and internal compositions of individual particles, typically detect these small particles with extremely low efficiencies. In this paper we describe a new instrument called SPLAT II that provides unparalleled sensitivity to small particles, detecting 100% of particles that are larger than 125 nm and 40% of 100 nm particles. This instrument also brings an increase by a factor of 10 in temporal resolution, sizing up to 500 particles per second and characterizing the composition of up to 100 of them. SPLAT II uses a two-laser, two-step process to evaporate the particles and generate ions, producing high quality, reproducible mass spectra of the refractive and non-refractive aerosol fractions to yield the complete compositions of individual particles. The instrument control board provides for size dependent delays for lasers’ triggers to eliminate a size dependent hit rate. The mass spectra are recorded with 14-bit vertical resolution and analyzed using custom software packages. The instrument’s high sizing resolution and sensitivity makes it possible to combine it with the differential mobility analyzer(s) and measure particle size, composition, density, dynamic shape factor, hygroscopicity, and fractal dimension.

47 OTHER INSTRUMENTATION↗