Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Material Deployment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Information Analysis Methodology for Border Security Deployment Prioritization and Post Deployment Evaluation

Due to international commerce, cross-border conflicts, and corruption, a holistic, information driven, approach to border security is required to best understand how resources should be applied to affect sustainable improvements in border security. The ability to transport goods and people by land, sea, and air across international borders with relative ease for legitimate commercial purposes creates a challenging environment to detect illicit smuggling activities that destabilize national level border security. Smuggling activities operated for profit or smuggling operations driven by cross border conflicts where militant or terrorist organizations facilitate the transport of materials and or extremists to advance a cause add complexity to smuggling interdiction efforts. Border security efforts are further hampered when corruption thwarts interdiction efforts or reduces the effectiveness of technology deployed to enhance border security. These issues necessitate the implementation of a holistic approach to border security that leverages all available data. Large amounts of information found in hundreds of thousands of documents can be compiled to assess national or regional borders to identify variables that influence border security. Location data associated with border topics of interest may be extracted and plotted to better characterize the current border security environment for a given country or region. This baseline assessment enables further analysis, but also documents the initial state of border security that can be used to evaluate progress after border security improvements are made. Then, border security threats are prioritized via a systems analysis approach. Mitigation factors to address risks can be developed and evaluated against inhibiting factor such as corruption. This holistic approach to border security helps address the dynamic smuggling interdiction environment where illicit activities divert to a new location that provides less resistance to smuggling activities after training or technology is deployed at a given location. This paper will present an approach to holistic border security information analysis.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Small Column Ion Exchange Design and Safety Strategy

Small Column Ion Exchange (SCIX) is a transformational technology originally developed by the Department of Energy (DOE) Environmental Management (EM-30) office and is now being deployed at the Savannah River Site (SRS) to significantly increase overall salt processing capacity and accelerate the Liquid Waste System life-cycle. The process combines strontium and actinide removal using Monosodium Titanate (MST), Rotary Microfiltration, and cesium removal using Crystalline Silicotitanate (CST, specifically UOP IONSIV{reg_sign}IE-911 ion exchanger) to create a low level waste stream to be disposed in grout and a high level waste stream to be vitrified. The process also includes preparation of the streams for disposal, e.g., grinding of the loaded CST material. These waste processing components are technically mature and flowsheet integration studies are being performed including glass formulations studies, application specific thermal modeling, and mixing studies. The deployment program includes design and fabrication of the Rotary Microfilter (RMF) assembly, ion-exchange columns (IXCs), and grinder module, utilizing an integrated system safety design approach. The design concept is to install the process inside an existing waste tank, Tank 41H. The process consists of a feed pump with a set of four RMFs, two IXCs, a media grinder, three Submersible Mixer Pumps (SMPs), and all supporting infrastructure including media receipt and preparation facilities. The design addresses MST mixing to achieve the required strontium and actinide removal and to prevent future retrieval problems. CST achieves very high cesium loadings (up to 1,100 curies per gallon (Ci/gal) bed volume). The design addresses the hazards associated with this material including heat management (in column and in-tank), as detailed in the thermal modeling. The CST must be size reduced for compatibility with downstream processes. The design addresses material transport into and out of the grinder and includes provisions for equipment maintenance including remote handling. The design includes a robust set of nuclear safety controls compliant with DOE Standard (STD)-1189, Integration of Safety into the Design Process. The controls cover explosions, spills, boiling, aerosolization, and criticality. Natural Phenomena Hazards (NPH) including seismic event, tornado/high wind, and wildland fire are considered. In addition, the SCIX process equipment was evaluated for impact to existing facility safety equipment including the waste tank itself. SCIX is an innovative program which leverages DOE's technology development capabilities to provide a basis for a successful field deployment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Comparison of Performance Between Organic Scintillation Crystals and Moderated (3)He-Based Detectors for Fission Neutron Detection

Direct detection of fast neutrons using organic scintillators is one alternative to moderated thermal neutron detectors deployed to detect fission neutrons - a relevant question in light of dwindling {sup 3}He supplies. Recent developments in materials science have demonstrated the capability to grow larger crystals in reasonable times. In light of these developments, this study compares the relative performance of a {sup 3}He-based neutron module from a commercially available portal monitor with a theoretical organic scintillator of similar overall size. Stilbene serves as a benchmark with its performance estimated from a combination of energy deposition modeled by radiation transport calculations and an assumption of the lowest neutron energy at which pulse shape discrimination can effectively separate neutron and gamma-ray events. Before intrinsic detection efficiencies on par with moderated detector systems can be achieved, the results point to the need for further advances including significant increases in detector size, especially thickness, and/or lower pulse shape discrimination thresholds.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Efficiency Fieldable Germanium Detector Array

Historically, large germanium arrays for field applications have consisted of multiple detectors each housed in their own cryostat. In order to ruggedize the detectors for field use these cryostats have had additional support material introduced that significantly impacted cryogenic performance. This paper presents the development of a new cryostat design suitable for deployment of ~10 kg of high purity germanium detectors that achieves outstanding cryogenic performance (~5 W at 80 K) while providing the high detection efficiency required for stand-off measurements and the ruggedization required for use in a variety of field applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface plasmon driven near- and midinfrared photoconductivity in ligand-free ITO nanocrystal films

Semiconductor nanocrystals (NCs) offer exciting opportunities to deploy infrared optoelectronic technology in a variety of applications that are off-limits to conventional single-crystalline materials. However, the performance and stability of state-of-the-art NC-based devices strongly depend on the details of the NC surface and its passivating ligands. Here, the authors use indium tin oxide NC films stripped of organic ligands and conformally coated with Al 2 O 3 to show that absorption enabled by infrared localized surface plasmon resonances permit infrared photoconduction. For Au electrodes, these metallic NC films exhibit stable photoconductive performance over months in ambient and under electrical stress.

36 MATERIALS SCIENCE↗

First Results from Nanoindentation of Vapor Diffused Nb3Sn Films on Nb

The mechanical vulnerability of the Nb3Sn-coated cavities is identified as one of the significant technical hurdles toward deploying them in practical accelerator applications in the not-so-distant future. It is crucial to characterize the material's mechanical properties in ways to address such vulnerability. Nanoindentation is a widely used technique for measuring the mechanical properties of thin films that involves indenting the film with a small diamond tip and measuring the force-displacement response to calculate the film's elastic modulus, hardness, and other mechanical properties. For the first time, the nanoindentation analysis was performed on multiple vapor-diffused Nb3Sn samples coated at Jefferson Lab and Fermilab coating facilities. This contribution will discuss the first results obtained from the nanoindentation of Nb3Sn-coated Nb samples prepared via the Sn vapor diffusion technique.

Pudasaini, Uttar↗

General Operational Procedure for Pedestrian Radiation Portal Monitors

This document outlines the basic conduct of operation (CONOPS) for a pedestrian radiation portal monitor (RPM), provided that the CONOPS is not facility or RPM specific and that it is based on a general understanding of a pedestrian RPM operation. The described CONOPS for a pedestrian RPM is defined by: (1) RPM design and operational characteristics, (2) type of pedestrian traffic, and (3) goal for RPM installation. Pedestrian RPMs normally are deployed for the continuous monitoring of individuals passing through point of control to detect the unauthorized traffic of radioactive/nuclear materials. RPMs generally are designed to detect gamma- and neutron-emitting materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of Robustness in TCR Design Strategies

Advanced Manufacturing (AM) has been identified as one of key pathways in accelerating deployment of next generation of nuclear power plants. The nuclear industry continues to predominately rely on fabrication techniques and materials that their codes and standards were approved decades ago. This legacy approach in the highly regulated nuclear sector has brought uncertainty to commercial viability of nuclear energy in the U.S. The Transformational Challenge Reactor (TCR), sought to utilize AM methods for fabrication of a High Temperature Gas Reactor (HTGR). The program sought to leverage AM to construct a non-conventional geometry made up of TRISO fuel and hydride moderator in SiC matrix. This project objective was to provide independent analysis of the core configuration with separate set of tools and approaches than utilized by the TCR team in a 2-year time frame. This NEUP project also tackled a question: Can AM be a cost-effective tool in changing the commercial paradigm of nuclear. We investigated this question in-context of a micro HTGR. While respecting the inherit uncertainty in our input parameters, overall we saw that AM has potential in improving economic competitiveness of nuclear energy when employed on multiple fronts (i.e. few percentage cost improvement per component). Given realizing AM requires mass orders and large R&D investment for commercial utilization, Department of Energy should focus its support on few key enabling technologies and support their codes and standards development and qualification cost (including irradiation as applicable) rather than taking a diluted approach.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

First Results from Nanoindentation of Vapor Diffused Nb3Sn Films on Nb

The mechanical vulnerability of the Nb3Sn-coated cavities is identified as one of the significant technical hurdles toward deploying them in practical accelerator applications in the not-so-distant future. It is crucial to characterize the material's mechanical properties in ways to address such vulnerability. Nanoindentation is a widely used technique for measuring the mechanical properties of thin films that involves indenting the film with a small diamond tip and measuring the force-displacement response to calculate the film's elastic modulus, hardness, and other mechanical properties. For the first time, the nanoindentation analysis was performed on multiple vapor-diffused Nb3Sn samples coated at Jefferson Lab and Fermilab Nb3Sn coating facilities. This contribution will discuss the first results obtained from the nanoindentation of Nb3Sn-coated Nb samples prepared via the Sn vapor diffusion technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Post Access Report: Initial testing of wave energy powered UV-C LED anti-biofouling system

In the experiment entitled “Initial Testing of Wave Energy Powered UV-C LED Anti-Biofouling System,” a UV-C LED was used to treat platinum-coated titanium coupons emulating CTD electrode material. An additional control set of coupons were exposed to seawater without the LED treatment. The experimental setup was deployed in seawater tanks at PNNL-Sequim’s Marine and Coastal Research Laboratory (MCRL) for the duration of six months. Tank seawater temperature data were collected for the duration of the experimental campaign. At two-month intervals triplicate sets of coupons were removed from both treatment and control test chambers and weighed to characterize biomass accumulation. After weighing, the coupons were photographed in initial condition, with a stain applied to highlight biofouling growth, and after rinsing off excess stain. These photographs were analyzed using PNNL’s Biofouling Growth Index (BGI) software and with a calculation of percentage dark pixels after conversion to grayscale. Additionally, at the final 6-month datapoint triplicate sets of control and test coupons were sent to PNNL-Richland’s Environmental Molecular Sciences Laboratory (EMSL) for scanning electron microscopy. All data organization and collection methods are described in further detail in the document “TEAMER_3newable_Data_Guide.pdf.” Biomass accumulation increased over time on both sets of coupons, and percent area biofouled demonstrated a similar trend. Analysis of the collected data resulted in the findings that treatment method has an impact on biofouling growth, though to a much less significant extent than time does. Additionally, qualitative findings included the presence of advanced life forms such as worms in the control test chamber, but not in the treated test chamber.

16 TIDAL AND WAVE POWER↗

Shuttle Tethered Satellite System Program Overview

The first of two demonstration flights of the tethered satellite system (TSS) is planned for the STS-52 flight and is designed to study tether electromagnetic interaction. The magnetospheric-ionospheric-atmospheric coupling processes in the lower troposphere are to be directly measured on the second TSS mission. An operational overview of the TSS-to-orbiter-to-ground interface is given and the TSS deployment concept is explained. Other aspects discussed include the tethered satellite-to-orbiter interface; tether control mechanisms; tether materials, and electrical interfaces. The design of the demonstration flight satellite and its instruments is described. The capabilities of the TSS for the demonstration flight are listed.

Crouch, D.↗

Contamination measurements on experiment M0003

The contamination monitors on the M0003 experiment consisted of passive sample collectors to measure molecular and particular deposition. The collectors were placed in the leading and trailing edge trays of M0003. The objective was to quantify the contaminants and determine how contamination affected the other materials in the trays. Duplicate collectors were placed inside the vacuum canisters that provided protection from the launch, ascent, deployment, and recovery environments.

Borson, Eugene N.↗

Contamination measurements on experiment M0003

The contamination monitors on the M0003 experiment consisted of passive sample collectors to measure molecular and particulate deposition. The collectors were placed in the leading and trailing edge trays of M0003. The objective was to quantify the contaminants and determine how contamination affected the other materials in the trays. Duplicate collectors were placed inside the vacuum canisters that provided protection from the launch, ascent, deployment, and recovery environments. Analyses of the samples show small quantities of molecular deposition on both the leading and trailing edge trays. Silicone deposits are negligible. The aluminized fused silica, second surface mirrors showed small changes in solar absorptances. This is consistent with the small quantities of molecular deposits deduced from the FTIR measurements. The results of particle deposition, light scatter, and a micrometeoroid (or debris) impact are presented.

Borson, Eugene N.↗

Penetrator Coring Apparatus for Cometary Surfaces

Touch and go impact coring is an attractive technique for sampling cometary nuclei and asteroidal surface on account of the uncertain strength properties and low surface gravities of these objects. Initial coring experiments in low temperature (approx. 153K polycrystalline ice) and porous rock demonstrate that simultaneous with impact coring, measurements of both the penetration strength and constraints on the frictional properties of surface materials can be obtained upon core penetration and core sample extraction. The method of sampling an asteroid, to be deployed, on the now launched MUSES-C mission, employs a small gun device that fires into the asteroid and the resulted impact ejecta is collected for return to Earth. This technique is well suited for initial sampling in a very low gravity environment and deployment depends little on asteroid surface mechanical properties. Since both asteroids and comets are believed to have altered surface properties a simple sampling apparatus that preserves stratigraphic information, such as impact coring is an attractive alternate to impact ejecta collection.

Braun, David F.↗

Overview of CTAS Research and Development at NASA Ames Research Center

This presentation will be a standard briefing package to be given at a variety of research laboratories in Europe in conjunction with site visits. The talk will include a brief overview of the history of CTAS, a summary of the development process and facilities, and will then highlight recent accomplishments and developments. These include Free Flight Phase One deployments, Free Flight Phase Two planned deployments, and recent results from research on tools in development, such as Active FAST and Direct-To. The material for the presentation will be drawn entirely from previously published material.

Edwards, Thomas A.↗

A Surface Science Paradigm for a Post-Huygens Titan Mission

With the Cassini-Huygens atmospheric probe drop-off mission fast approaching, it is essential that scientists and engineers start scoping potential follow-on surface science missions. This paper provides a summary of the first year of a two year design study which examines in detail the desired surface science measurements and resolution, potential instrument suite, and complete payload delivery system. Also provided are design concepts for both an aerial inflatable mobility platform and deployable instrument sonde. The tethered deployable sonde provides the capability to sample nearsurface atmosphere, sub-surface liquid (if it exists), and surface solid material. Actual laboratory tests of the amphibious sonde prototype are also presented.

Cassini-Huygen↗