Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MALES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Percutaneous Transcholecystic Placement of an ePTFE/FEP-Covered Stent in the Common Bile Duct

We report the case of a 78-year-old male patient with obstructive jaundice due to a pancreatic head neoplasm. The patient's general condition did not permit an endoscopic approach and the presence of diffuse liver metastases prohibited hepatic puncture for percutaneous biliary drainage, therefore the transcolecystic transperitoneal approach was decided to be the safest decompression route. Through a gallbladder access, a Viabil-covered stent with a mesh extension was placed in the distal common bile duct, without complications. The patient died 8 months later without signs of stent dysfunction or necessity of reintervention. Transcholecystic transperitoneal access is a safe option when diffuse liver metastases prohibit the transhepatic approach, even in cases where placement of a covered stent is considered necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Traumatic Inferior Gluteal Artery Aneurysm Managed with Emergency Transcatheter Thrombin Injection

Pseudoaneurysms of the inferior gluteal artery (IGA) are rare and are often caused by trauma. Treatment options vary and include surgery, ultrasound-guided percutaneous thrombin injection, and endovascular procedures such as stent-graft placement, coil embolization, and glue injection. We report a 70-year-old male who presented to the hospital after a road accident with a posttraumatic pseudoaneurysm that was treated by endovascular thrombin embolization. To the best of our knowledge, this is the first reported case of inferior gluteal artery false aneurysm treated by this method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

OptEase and TrapEase Vena Cava Filters: A Single-Center Experience in 258 Patients

We aimed to evaluate the efficacy and safety of the OptEase and TrapEase (both from Cordis, Roden, Netherlands) vena cava filters in the prevention of pulmonary embolism (PE). Between May 2004 and December 2008, OptEase (permanent/retrievable; n = 228) or TrapEase (permanent; n = 30) vena cava filters were placed in 258 patients (160 female and 98 male; mean age 62 years [range 22 to 97]). Indications were as follows: prophylaxis for PE (n = 239), contraindication for anticoagulation in the presence of PE or DVT (n = 10), and development of PE or DVT despite anticoagulation (n = 9). Medical records were retrospectively reviewed for indications, clinical results, and procedure-related complications during placement and retrieval. Clinical PE did not develop in any of the patients. However, radiologic signs of segmental PE were seen in 6 of 66 patients with follow-up imaging data. Migration or fracture of the filter or cava perforation was not seen in any of the patients. Except for a single case of asymptomatic total cava thrombosis, no thrombotic occlusion was observed. One hundred forty-one patients were scheduled to undergo filter removal; however, 17 of them were not suitable for such based on venography evaluation. Removal was attempted in 124 patients and was successful in 115 of these (mean duration of retention 11 days [range 4 to 23]). Nine filters could not be removed. Permanent/retrievable vena cava filters are safe and effective devices for PE prophylaxis and for the management of venous thromboembolism by providing the option to be left in place.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ten-Year Follow-Up of Endovascular Aneurysm Treatment with Talent Stent-Grafts

The purpose of this study was to evaluate the clinical results, complications, and secondary interventions during long-term follow-up after endovascular aneurysm repair (EVAR) and to investigate the impact of endoleak sizes on aneurysm shrinkage. From 1997 to March 2007, 127 patients (12 female, 115 male; age, 73.0 {+-} 7.2 years) with abdominal aortic aneurysms were treated with Talent stent-grafts. Follow-up included clinical visits, contrast-enhanced MDCT, and radiographs at 3, 6, and 12 months and then annually. Results were analyzed with respect to clinical outcome, secondary interventions, endoleak rate and management, and change in aneurysm size. There was no need for primary conversion surgery. Thirty-day mortality was 1.6% (two myocardial infarctions). Procedure-related morbidity was 2.4% (paraplegia, partial infarction of one kidney, and inguinal bleeding requiring surgery). Mean follow-up was 47.7 {+-} 34.2 months (range, 0-123 months). Thirty-nine patients died during follow-up; three of the deaths were related to aneurysm (aneurysm rupture due to endoleak, n = 1; secondary surgical reintervention n = 2). During follow-up, a total of 29 secondary procedures were performed in 19 patients, including 14 percutaneous procedures (10 patients) and 15 surgical procedures (12 patients), including 4 cases with late conversion to open aortic repair (stent-graft infection, n = 1; migration, endoleak, or endotension, n = 3). Overall mean survival was 84.5 {+-} 4.7 months. Mean survival and freedom from any event was 66.7 {+-} 4.5 months. MRI depicted significantly more endoleaks compared to MDCT (23.5% vs. 14.3%; P < 0.01). Patients in whom all aneurysm side branches were occluded prior to stent-grafting showed a significantly reduced incidence of large endoleaks. Endoleaks >10% of the aneurysm area were associated with reduced aneurysm shrinkage compared to no endoleaks or <10% endoleaks ({Delta} at 3 years, -1.8% vs. -12.0%; P < 0.05). In conclusion, endovascular aneurysm treatment with Talent stent-grafts demonstrated encouraging long-term results with moderate secondary intervention rates. Primary occlusion of all aortic side branches reduced the incidence of large endoleaks. Large endoleaks significantly impaired aneurysm shrinkage, whereas small endoleaks did not.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transient Encephalopathy from Angiographic Contrast: A Rare Complication in Neurointerventional Procedures

Neurotoxicity from contrast media used in angiography is a rare complication from these procedures. The infrequency with which it is encountered makes it a diagnostic challenge. We present the case of a 51-year-old male who, 30 min after successful angiography for treatment of a right carotid-ophthalmic fusiform aneurysm with a stent, developed psychomotor agitation, disorientation, and progressive left faciobrachial hemiparesis (4/5). An emergency nonenhanced CT showed marked cortical enhancement and edema in the right cerebral hemisphere. Cortical enhancement is thought to be secondary to contrast extravasation due to disruption of the blood-brain barrier. Angiography was performed immediately, without any pathologic findings. After this procedure there was an increase in the left faciobrachial hemiparesis (3/5), right gaze deviation, Gerstmann syndrome, and left anosognosia and left homonymous hemianopsia. Endovenous dexamethasone and mannitol were initiated. Twenty-four hours later an MRI showed no signs of acute infarct, just gyriform signal increase in the right cerebral hemisphere on FLAIR and a decrease in the edema observed before. The patient had progressive improvement of his neurological deficit. A control MRI done 5 days later was normal. The patient recovered completely and was discharged. This rare entity should be kept in mind but diagnosed only when all other causes have been ruled out, because more important and frequent causes, such as acute infarct, must be excluded promptly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outcomes of Interventions Via a Transradial Approach for Dysfunctional Brescia-Cimino Fistulas

The transradial artery approach to angioplasty has rarely been reported as a method for treating dysfunctional Brescia-Cimino fistulas. This study evaluated the feasibility, safety, and 1-year efficacy of this method for treating dysfunctional Brescia-Cimino fistulas. We retrospectively evaluated 154 consecutive procedures in 131 patients (age, 58.3 {+-} 11.6 years; male, 48.1%) who underwent the transradial approach in dysfunctional Brescia-Cimino fistulas in the 1-year period after the procedure. The operator determined the use of a regular or a cutting balloon (two cases) in combination with urokinase injection (one case) or catheter thromboaspiration. Radial artery puncture was successful in all cases. Fifty-two cases (33.8%) had totally occluded fibrotic lesions. The overall anatomic success rate and clinical success rate were 61% (94/154) and 81.1% (125/154), respectively. In cases with a totally occluded fibrotic lesion, the clinical success rate was 46%. Successful intervention was associated with a significant reduction in the radial arterial systolic and diastolic pressures. There were no complications of symptomatic arterial embolization or pulmonary embolism, and one complication of venous rupture was successfully treated by compression. The primary patency rates based on intention-to-treat were 75.3% at 30 days and 39.0% at 1 year after the procedure. Excluding the cases with a totally occluded lesion, the clinical success rate was 99% (101/102) and the primary patency rates were 84.3% (86/102) and 52.0% (53/102) at 3 months and 1 year after the procedure, respectively. In conclusion, the transradial approach is a feasible, safe, and effective alternative for catheter intervention for dysfunctional Brescia-Cimino fistulas. Its success rate in cases with a totally occluded fibrotic lesion is unsatisfactory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broken Esophageal Stent Successfully Treated by Interventional Radiology Technique

Esophageal stent fractures occur quite rarely. A 61-year-old male patient was previously treated for rupture of benign stenosis, occurring after dilatation, by implanting an esophageal stent. However, a year after implantation, the patient suffered from dysphagia caused by the broken esophageal stent. He was treated with the interventional radiology technique, whereby a second implantation of the esophageal stent was carried out quite successfully.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Coarctation of the Distal Thoracic Aorta with a Supradiaphragmatic Origin of the Celiacomesenteric Trunk: An Anatomic and Etiologic Description

Stenosis of the distal thoracic aorta was found during an evaluation for incidentally detected hypertension in a 21-year-old male patient. A celiacomesenteric trunk originated from just above the coarctation site in the thorax, and the lower posterior intercostal arteries showed unusual low origins. Consideration of these anatomies suggests that the etiology of this case is congenital.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Always Contact a Vascular Interventional Specialist Before Amputating a Patient with Critical Limb Ischemia

Patients with severe critical limb ischemia (CLI) due to long tibial artery occlusions are often poor candidates for surgical revascularization and frequently end up with a lower limb amputation. Subintimal angioplasty (SA) offers a minimally invasive alternative for limb salvage in this severely compromised patient population. The objective of this study was to evaluate the results of SA in patients with CLI caused by long tibial occlusions who have no surgical options for revascularization and are facing amputation. We retrospectively reviewed all consecutive patients with CLI due to long tibial occlusions who were scheduled for amputation because they had no surgical options for revascularization and who were treated by SA. A total of 26 procedures in 25 patients (14 males; mean age, 70 {+-} 15 [SD] years) were evaluated. Technical success rate was 88% (23/26). There were four complications, which were treated conservatively. Finally, in 10 of 26 limbs, no amputation was needed. A major amputation was needed in 10 limbs (7 below-knee amputations and 3 above-knee amputations). Half of the major amputations took place within 3 months after the procedure. Cumulative freedom of major amputation after 12 months was 59% (SE = 11%). In six limbs, amputation was limited to a minor amputation. Seven patients (28%) died during follow-up. In conclusion, SA of the tibial arteries seem to be a valuable treatment option to prevent major amputation in patients with CLI who are facing amputation due to lack of surgical options.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Short-Term Effects of Transjugular Intrahepatic Shunt on Cardiac Function Assessed by Cardiac MRI: Preliminary Results

The purpose of this study was to assess short-term effects of transjugular intrahepatic shunt (TIPS) on cardiac function with cardiac magnetic resonance imaging (MRI) in patients with liver cirrhosis. Eleven patients (six males and five females) with intractable esophageal varices or refractory ascites were imaged with MRI at 1.5 T prior to, within 24 h after, and 4-6 months after TIPS creation (n = 5). Invasive pressures were registered during TIPS creation. MRI consisted of a stack of contiguous slices as well as phase contrast images at all four valve planes and perpendicular to the portal vein. Imaging data were analyzed through time-volume curves and first derivatives. The portoatrial pressure gradient decreased from 19.8 {+-} 2.3 to 6.6 {+-} 2.3, accompanied by a nearly two fold increase in central pressures and pulmonary capillary wedge pressure immediately after TIPS creation. Left and right end diastolic volumes and stroke volumes increased by 11, 13, and 24%, respectively (p < 0.001), but dropped back to baseline at follow-up. End systolic volumes remained unchanged. E/A ratios remained within normal range. During follow-up the left ventricular mass was larger than baseline values in all patients, with an average increase of 7.9 g (p < 0.001). In conclusion, the increased volume load shunted to the heart after TIPS creation transiently exceeded the preload reserve of the right and left ventricle, leading to significantly increased pulmonary wedge pressures and persistent enlargement of the left and right atria. Normalization of cardiac dimensions was observed after months together with mild left ventricular hypertrophy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Vertebral Arteriovenous Fistula Presenting as Cervical Myelopathy: A Rapid Recovery with Balloon Embolization

A 24-year-old male presented with progressive cervical myelopathy of 2 months' duration. Magnetic resonance imaging of the cervical spine and angiography revealed a large arteriovenous fistula arising from the left vertebral artery. The present case highlights the clinical features and dramatic recovery following endovascular balloon occlusion of a giant cervical arteriovenous fistula.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MDCT Versus MRI Assessment of Tumor Response After Transarterial Chemoembolization for the Treatment of Hepatocellular Carcinoma

The purpose of this study was to compare the ability of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) to evaluate treatment results after transarterial chemoembolization (TACE), with a special focus on the influence of Lipiodol on calculation of tumor necrosis according to EASL criteria. A total of 115 nodules in 20 patients (17 males, 3 females; 69.5 {+-} 9.35 years) with biopsy-proven hepatocellular carcinoma were treated with TACE. Embolization was performed using a doxorubicin-Lipiodol emulsion (group I) or DC Beads loaded with doxorubicin (group II). Follow-up included triphasic contrast-enhanced 64-row MDCT (collimation, 0.625 mm; slice, 3 mm; contrast bolus, 120 ml iomeprol; delay by bolus trigger) and contrast-enhanced MRI (T1 native, T2 native; five dynamic contrast-enhanced phases; 0.1 mmol/kg body weight gadolinium-DTPA; slice thickness, 4 mm). Residual tumor and the extent of tumor necrosis were evaluated according to EASL. Contrast enhancement within tumor lesions was suspected to represent vital tumor. In the Lipiodol-based TACE protocol, MDCT underestimated residual viable tumor compared to MRI, due to Lipiodol artifacts (23.2% vs 47.7% after first, 11.9% vs 31.2% after second, and 11.4% vs 23.7% after third TACE; p = 0.0014, p < 0.001, and p < 0.001, respectively). In contrast to MDCT, MRI was completely free of any artifacts caused by Lipiodol. In the DC Bead-based Lipiodol-free TACE protocol, MRI and CT showed similar residual tumor and rating of treatment results (46.4% vs 41.2%, 31.9 vs 26.8%, and 26.0% vs 25.6%; n.s.). In conclusion, MRI is superior to MDCT for detection of viable tumor residuals after Lipiodol-based TACE. Since viable tumor tissue is superimposed by Lipiodol artifacts in MDCT, MRI is mandatory for reliable decision-making during follow-up after Lipiodol-based TACE protocols.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endoluminal Intervention in the Salivary Duct: Clinical Outcomes at a District General Hospital

Our aim was to assess the preliminary clinical outcomes of interventional radiology for salivary duct obstruction in relation to salivary duct strictures or calculi. A retrospective analysis of consecutive patients referred for endoluminal procedures by ENT surgeons during a 4-year period were identified. The procedure was performed by a single interventional radiologist under fluoroscopic guidance using wire baskets and angioplasty balloons. Between June 2004 and October 2008, 50 sialoplasties were performed in 43 patients (30 female and 13 male). Twenty-six patients were prepared for 32 procedures for extraction of calculi (13 submandibular and 13 parotid), and 17 patients had 18 procedures for strictures (16 parotid and 1 submandibular). One patient in the group with calculi was judged unsuitable for intervention because the stone had migrated outside the salivary duct. Information was collected regarding the clinical indication; duration and type of symptoms; technical factors; follow-up; and success or failure of reintervention. Complete stone removal was achieved in 18 of the 26 patients (69%), with success on the first attempt in 14 patients (54%). Redo procedures were required in 4 patients (15%), with subsequent complete clearance of calculi. In this cohort, 20 patients were symptomatically improved (77%). Of the 6 patients (26%) with continuing symptoms, 2 patients had mild symptoms; two had moderate symptoms; and two patients opted to have surgery for unremitting symptoms. In the stricture group, 18 procedures were performed in 17 patients, with a successful outcome in 16 patients after the initial sialoplasty. Only 1 patient required repeat intervention (6%) and later opted to have surgery for continuing symptoms. In this group, 14 patients (82%) were symptomatically improved, and 3 remained symptomatic despite a good immediate result due to restenosis. Two patients experienced early complications: One had a transient facial nerve palsy, and the other had sialadenitis treated with antibiotics. Preliminary results suggest that symptom resolution at first intervention is higher in patients with acalculous strictures. Patients with calculi are more likely to require a repeat procedure for complete clearance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

One Year Clinical Outcomes of Renal Artery Stenting: The Results of ODORI Registry

The safety, efficacy and long term clinical benefits of renal artery revascularization by stenting are still a matter of debate. The aim of our study was to define the safety and efficacy of renal artery stenting with the Tsunami peripheral stent (Terumo Corporation, Tokyo, Japan). The ODORI was a prospective, multicentre registry which enrolled 251 consecutive patients, (276 renal arteries) in 36 centres across Europe. The primary endpoint was acute procedural success defined as <30% residual stenosis after stent placement. Secondary endpoints included major adverse events, blood pressure control, serum creatinine level, and target lesion revascularization (TLR) at 6 and 12 months. Patients were 70 {+-} 10 years old, 59% were male, 33% had diabetes, and 96% hypertension. The main indications for renal stent implantation were hypertension in 83% and renal salvage in 39%. Direct stent implantation was performed in 76% of the cases. Acute success rate was 100% with residual stenosis of 2.5 {+-} 5.4%. Systolic/diastolic blood pressure decreased from a mean of 171/89 at baseline to 142/78 mmHg at 6 months (p < 0.0001 vs. baseline), and 141/80 mmHg at 12 months (p < 0.0001 vs. baseline). Mean serum creatinine concentration did not change significantly in the total population. However, there was significant improvement in the highest tercile (from 283 {mu}mol/l at baseline to 205 and 209 {mu}mol/l at 6 and 12 months respectively). At 12-months, rates of restenosis and TLR were 6.6 and 0.8% respectively. The 12 month cumulative rate of all major clinical adverse events was 6.4% while the rate of device or procedure related events was 2.4%. In hypertensive patients with atherosclerotic renal artery stenosis Tsunami peripheral balloon-expandable stent provides a safe revascularization strategy, with a potential beneficial impact on hypertension control and renal function in the highest risk patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comparison of Transjugular and Plugged-Percutaneous Liver Biopsy in Patients with Contraindications to Ordinary Percutaneous Liver Biopsy and an 'In-House' Protocol for Selecting the Procedure of Choice

The purpose of this study was to evaluate the effectiveness and safety of transjugular liver biopsy (TJLB) and plugged-percutaneous liver biopsy (PB) in consecutive patients with severe liver disease associated with impaired coagulation, ascites, or both and to verify the in-house protocol used to select the appropriate procedure. In 2000-2006, 329 patients (208 male [62.8%] and 121 female [37.2%]), aged 1 month to 81 years (mean, 46.8 years), underwent 150 TJLBs (39.1%) or 233 PBs (60.9%) procedures at a major tertiary center, as determined by an in-house protocol. The groups were compared for specimen characteristics, technical success, and complications. Technical success rates were 97.4% for TJLB (146/150) and 99.1% for PB (231/233). TJLB was associated with a lower average core length (1.29 vs. 1.43 cm) and lower average number of specimens obtained (2.44 vs. 2.8), but both methods yielded sufficient tissue for a definitive diagnosis. There were no major complications in either group. TJLB and PB can be safely and effectively performed for the diagnosis of hepatic disease in patients with contraindications for standard percutaneous liver biopsy. When both are technically available, we suggest PB as the procedure of choice, especially in transplanted livers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Antenna Microwave Ablation Under Contrast-Enhanced Ultrasound Guidance for Treatment of Small Renal Cell Carcinoma: Preliminary Experience

The purpose of this study was to determine the safety, effectiveness, and feasibility of microwave ablation (MWA) of small renal cell carcinomas (RCCs) in selected patients. Institutional review board and informed consent were obtained. From December 2007 to January 2009, 12 patients (8 male, 4 female) were enrolled in a treatment group, in which percutaneous MWA of small RCCs was performed under contrast-enhanced ultrasound guidance. The tumors were 1.7-2.9 cm in diameter (mean diameter, 2.0 cm).Therapeutic effects were assessed at follow-up with computed tomography. All patients were followed up for 3-14 months (mean, 6 months) to observe the therapeutic effects and complications (according to SIR classification). Assessment was carried out with CT imaging. No severe complications or unexpected side effects were observed after the MWA procedures. In all cases technical success was achieved. Clinical effectiveness was 100%; none of the patients showed recurrence on imaging. In conclusion, our preliminary results support the use of MWA for the treatment of small renal tumors. This technology can be applied in select patients who are not candidates for surgery, as an alternative to other ablative techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Experience with the Amplatzer Vascular Plug II for Occlusive Purposes in Arteriovenous Hemodialysis Access

The Amplatzer Vascular Plug Type II (AVP II) has proven effective in the therapeutic embolization of various vascular lesions. It benefits from very rapid occlusion of the target lesion and can be deployed, retrieved, and redeployed if required. There is no literature available on use of the AVP II in the maintenance, closure, and management of complicated arteriovenous access in hemodialysis patients. In this series, we present our clinical experience with the use of the AVP II for embolization of problematic hemodialysis access. The AVP II is a self-expandable Nitinol wire-mesh device. Mounted on a delivery wire it has the capability to be deployed, recaptured, and redeployed. In total seven patients (four males: one diabetic, all nonsmokers), with ages ranging from 44 to 81 years (mean, 63 years), were treated between July 2008 and January 2009. One patient had not started dialysis. The remaining six patients had varied histories, with the time on hemodialysis ranging from 1 to 21 years. Retrospective review of clinical notes revealed patient demographics, type of access, device size, deployment site, and outcomes. Indications for embolization included steal syndrome (one patient), high-flow tributaries (two patients), and limb swelling (four patients). All patients had clinical and sonographical follow-up to 3 months. Surgical ligation had either failed, was considered a contraindication due to concerns regarding wound healing, or was considered difficult due to complex venous anatomy. Only one device was used in each patient, ranging from 6 to 16 mm in diameter. Immediate technical success was seen in 100%. All these patients were followed up clinically in the vascular access radiology clinic at 4 weeks and 3 months. Occlusion of the treated vessel and resolution of symptoms were reconfirmed in 100% of cases at 3 months. It was also noted whether patients were having successful dialysis, if required. There were no complications. Average procedural time was 19 min. We conclude that the AVP II is an efficient, safe, and technically simple occlusion device for use in arteriovenous access.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Replacement of Mushroom Cage Gastrostomy Tube Using a Modified Technique to Allow Percutaneous Replacement with an Endoscopic Tube in Patients with Amyotrophic Lateral Sclerosis

Radiologic inserted gastrostomy (RIG) is the preferred method in our institution for enteral feeding in amyotrophic lateral sclerosis (ALS). Skin-level primary-placed mushroom cage gastrostomy tubes become tight with weight gain. We describe a minimally invasive radiologic technique for replacing mushroom gastrostomy tubes with endoscopic mushroom cage tubes in ALS. All patients with ALS who underwent replacement of a RIG tube were included. Patients were selected for a modified replacement when the tube length of the primary placed RIG tube was insufficient to allow like-for-like replacement. Replacement was performed under local anesthetic and fluoroscopic guidance according to a preset technique, with modification of an endoscopic mushroom cage gastrostomy tube to allow percutaneous placement. Assessment of the success, safety, and durability of the modified technique was undertaken. Over a 60-month period, 104 primary placement mushroom cage tubes in ALS were performed. A total of 20 (19.2%) of 104 patients had a replacement tube positioned, 10 (9.6%) of 104 with the modified technique (male n = 4, female n = 6, mean age 65.5 years, range 48-85 years). All tubes were successfully replaced using this modified technique, with two minor complications (superficial wound infection and minor hemorrhage). The mean length of time of tube durability was 158.5 days (range 6-471 days), with all but one patient dying with a functional tube in place. We have devised a modification to allow percutaneous replacement of mushroom cage gastrostomy feeding tubes with minimal compromise to ALS patients. This technique allows tube replacement under local anesthetic, without the need for sedation, an important consideration in ALS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗