Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Decoupling exchange bias and coercivity enhancement in a perovskite oxide exchange spring bilayer

A wedge bilayer of epitaxial 4–8 nm La 0.7 Sr 0.3 CoO 3 (LSCO)/6-nm La 0.7 Sr 0.3 MnO 3 (LSMO), hard and soft ferromagnets (FM) respectively, was studied using soft x-ray magnetic spectroscopy to elucidate the interplay between the magnetic and electronic properties of the constituent layers. This system exhibits magnetic and electronic segregation within the LSCO layer characterized by soft FM Co 2+ ions at the interface (s-LSCO), which is biased by the underlying hard LSCO layer (h-LSCO), characterized by predominantly Co 3+ /Co 4+ FM ions. For a 5.1-nm layer, the interfacial Co 2+ ion concentration is maximized and the h-LSCO coercivity is minimized, while the opposite is true for a 7.8-nm LSCO layer. Furthermore these dual trends in Co 2+ ion concentration and h-LSCO coercivity within the LSCO serve to independently affect the exchange bias and coercivity of the soft FM layer, resulting in inverse trends between these properties that typically vary simultaneously.

36 MATERIALS SCIENCE↗

Analytical and experimental performance of a dual-mode traveling wave tube and multistage depressed collector

A computational procedure for the design of traveling-wave-tube(TWT)/refocuser/multistage depressed collector (MDC) systems was used to design a short, permanent-magnet refocusing system and a highly efficient MDC for a medium-power, dual-mode, 4.8- to 9.6-GHz TWT. The computations were carried out with advanced, multidimensional computer programs which model the electron beam and follow the trajectories of representative charges from the radiofrequency (RF) input of the TWT, through the slow-wave structure and refocusing section, to their points of impact in the depressed collector. Secondary emission losses in the MDC were treated semiquantitatively by injecting representative secondary-electron-emission current into the MDA analysis at the point of impact of each primary beam. A comparison of computed and measured TWT and MDC performance showed very good agreement. The electrodes of the MDC were fabricated from a particluar form of isptropic graphite that was selected for its low secondary electron yield, ease of machinability, and vacuum properties.

Ramins, Peter↗

The role of the non-magnetic material in spin pumping and magnetization dynamics in NiFe and CoFeB multilayer systems

We present a study of the effective magnetization M{sub eff} and the effective damping parameter α{sub eff} by means of ferromagnetic resonance spectroscopy on the ferromagnetic (FM) materials Ni{sub 81}Fe{sub 19} (NiFe) and Co{sub 40}Fe{sub 40}B{sub 20} (CoFeB) in FM/Pt, FM/NM, and FM/NM/Pt systems with the non-magnetic (NM) materials Ru, Cr, Al, and MgO. Moreover, for NiFe layer systems, the influence of interface effects is studied by way of thickness dependent measurements of M{sub eff} and α{sub eff}. Additionally, spin pumping in NiFe/NM/Pt is investigated by means of inverse spin Hall effect (ISHE) measurements. We observe a large dependence of M{sub eff} and α{sub eff} of the NiFe films on the adjacent NM layer. While Cr and Al do not induce a large change in the magnetic properties, Ru, Pt, and MgO affect M{sub eff} and α{sub eff} in different degrees. In particular, NiFe/Ru and NiFe/Ru/Pt systems show a large perpendicular surface anisotropy and a significant enhancement of the damping. In contrast, the magnetic properties of CoFeB films do not have a large influence of the NM adjacent material and only CoFeB/Pt systems present an enhancement of α{sub eff}. However, this enhancement is much more pronounced in NiFe/Pt. By the introduction of the NM spacer material, this enhancement is reduced. Furthermore, a difference in symmetry between NiFe/NM/Pt and NiFe/NM systems in the output voltage signal from the ISHE measurements reveals the presence of spin pumping into the Pt layer in all-metallic NiFe/NM/Pt and NiFe/Pt systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic particle imaging of blood coagulation

We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Interface colloidal robotic manipulator

A magnetic colloidal system confined at the interface between two immiscible liquids and energized by an alternating magnetic field dynamically self-assembles into localized asters and arrays of asters. The colloidal system exhibits locomotion and shape change. By controlling a small external magnetic field applied parallel to the interface, structures can capture, transport, and position target particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonnuclear Experimental Capabilities to Support Design, Development, and Demonstration of Microreactors

This work provides a summary of selected experimental capabilities being developed to support nonnuclear testing and demonstration of technology in support of microreactors under the U.S. Department of Energy’s (DOE’s) Microreactor Program. Major capabilities include the Single Primary Heat Extraction and Removal Emulator (SPHERE) and the Microreactor Agile Non-nuclear Experimental Test Bed (MAGNET). The SPHERE facility allows for controlled testing of the steady-state and transient heat rejection capabilities of a single heat pipe using electrical heaters that simulate nuclear heating. The facility is capable of monitoring axial temperature profiles along the heat pipe and surrounding test articles during startup, steady-state operation, and transients. Instrumentation includes noncontact infrared thermal imaging, surface thermocouples, spatially distributed fiber optic temperature and strain sensors, electrical power meters, and a water-cooled, gas-gap calorimeter for quantifying heat rejection from the heat pipe. The facility can be operated under both vacuum and inert-gas conditions. The MAGNET facility is a large-scale, 250-kW electrically heated microreactor test bed to enable nonnuclear experimental evaluation of a variety of microreactor concepts. It can be supplied to electrically heat a scaled section of a microreactor and further test the capabilities of heat rejection systems. The initial MAGNET experiments will support technology maturation and reduce uncertainty and risk associated with the design, operation, and deployment of monolithic heat pipe–based reactors. However, this test bed can broadly be applied to multiple microreactor concepts to evaluate a wide range of thermal-hydraulic and structural phenomena such as interface coupling with power conversion units and other collocated systems. MAGNET can evaluate integral thermomechanical effects during electrical heating of an array of heat pipes in a larger test article. Examples of initial testing will include thermal stresses in the monolith and the impact of debonding of a heat pipe from the core block and how that failure could impact surrounding heat pipes, i.e., understanding the potential for cascading failure. This work also discusses some modeling capabilities that can support experiment design, analysis, and interpretation, including the heat pipe code Sockeye and a comparison of thermal-structural simulations performed using ABAQUS and STAR-CCM+.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Atomistic theories and Simulations of Multiferroics

The goal of this award was to build a research program aimed at investigating puzzling complex phenomena in multiferroics, that are systems possessing electric and magnetic dipoles. We first emphasized the study of multiferroic nanostructures, that are 0D, 1D, 2D systems as well as superlattices and then also study multiferroics as a whole, i.e., bulks as well. In order to fully understand such complex systems, we also decided to study magnetic systems and ferroelectrics, both in their nanostructure and bulk forms. For that and in addition to use standard Density Functional Theory codes, we developed and used ab-initio tools that are able to model properties of large supercells (about a million atoms nowadays) at finite temperature and for any mechanical and boundary conditions. We also collaborated with experimentalists to fully understand the systems under study. The whole program resulted in 108 publications that are listed at the end of this report. In the following, I will put an emphasis on some publications before the last award period and also indicate a description of the last award period.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined alternating gradient force magnetometer and susceptometer system

We report the design, fabrication, and characterization of a new system that combines the performances of two different types of magnetic characterization systems, Alternating Gradient Force Magnetometers (AGFM) and susceptometers. The flexibility of our system is demonstrated by its capability to be used as any of them, AGFM or susceptometer, without any modification in the experimental set-up because of the electronics we have developed. Our system has a limit of sensitivity lower than 5 × 10{sup −7} emu. Moreover, its main advantage is demonstrated by the possibility of measuring small quantities of materials under DC or AC magnetic fields that cannot properly be measured with a commercial vibrating sample magnetometers or AGFM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tailored Micromagnet Sorting Gate for Simultaneous Multiple Cell Screening in Portable Magnetophoretic Cell‐On‐Chip Platforms

Abstract Conventional magnetophoresis techniques for manipulating biocarriers and cells predominantly rely on large‐scale electromagnetic systems, which is a major obstacle to the development of portable and miniaturized cell‐on‐chip platforms. Herein, a novel magnetic engineering approach by tailoring a nanoscale notch on a disk micromagnet using two‐step optical and thermal lithography is developed. Versatile manipulations are demonstrated, such as separation and trapping, of carriers and cells by mediating changes in the magnetic domain structure and discontinuous movement of magnetic energy wells around the circumferential edge of the micromagnet caused by a locally fabricated nano‐notch in a low magnetic field system. The motion of the magnetic energy well is regulated by the configuration of the nanoscale notch and the strength and frequency of the magnetic field, accompanying the jump motion of the carriers. The proposed concepts demonstrate that multiple carriers and cells can be manipulated and sorted using optimized nanoscale multi‐notch gates for a portable magnetophoretic system. This highlights the potential for developing cost‐effective point‐of‐care testing and lab‐on‐chip systems for various single‐cell‐level diagnoses and analyses.

36 MATERIALS SCIENCE↗

Control Study for Five-axis Dynamic Spin Rig Using Magnetic Bearings

The NASA Glenn Research Center (GRC) has developed a magnetic bearing system for the Dynamic Spin Rig (DSR) with a fully suspended shaft that is used to perform vibration tests of turbomachinery blades and components under spinning conditions in a vacuum. Two heteropolar radial magnetic bearings and a thrust magnetic bearing and the associated control system were integrated into the DSR to provide magnetic excitation as well as non-contact mag- netic suspension of a 15.88 kg (35 lb) vertical rotor with blades to induce turbomachinery blade vibration. For rotor levitation, a proportional-integral-derivative (PID) controller with a special feature for multidirectional radial excitation worked well to both support and shake the shaft with blades. However, more advanced controllers were developed and successfully tested to determine the optimal controller in terms of sensor and processing noise reduction, smaller rotor orbits, more blade vibration amplitude, and energy savings for the system. The test results of a variety of controllers that were demonstrated up to 10.000 rpm are shown. Furthermore, rotor excitation operation and conceptual study of active blade vibration control are addressed.

Choi, Benjamin↗

Crystallographic and magnetic properties of the spinel-type ferrites Zn{sub x}Co{sub 1-x}Fe{sub 2}O{sub 4} (0.0 ≤ x ≤ 0.75)

Ultrahigh frequencies (UHF) have applications in signal and power electronics to minimize product sizes, increase production quantity and lower manufacturing cost. In the UHF range of 300 MHz to 3 GHz, ferrimagnetic iron oxides (ferrites) are especially useful because they combine the properties of a magnetic material with that of an electrical insulator. Ferrites have much higher electrical resistivity than metallic ferromagnetic materials, resulting in minimization of the eddy current losses, and total penetration of the electromagnetic (EM) field. Hence ferrites are frequently applied as circuit elements, magnetic storage media like read/write heads, phase shifters and Faraday rotators. The electromagnetic properties of ferrites are affected by operating conditions such as field strength, temperature and frequency. The spinel system Zn{sub x}Co{sub 1-x}Fe{sub 2}O{sub 4} (x=0.0, 0.25, 0.50 and 0.75) has been prepared by the standard solid state sintering method. X-ray and neutron powder diffraction measurements were performed at room temperature. Neutron diffraction data analysis confirms the cubic symmetry corresponding to the space group Fd3m. The distribution of three cations Zn{sup 2+}, Co{sup 2+} and Fe{sup 3+} over the spinel lattice and other crystallographic parameters like lattice constant, oxygen position parameter, overall temperature factor and occupancies of different ions in different lattice sites for the samples have been determined from the analysis of neutron diffraction data. The lattice constant increases with increasing Zn content in the system. The magnetic structure was found to be ferrimagnetic for the samples with x≤0.50. Magnetization measurements show that with the increase of Zn content in the system the value of saturation magnetization first increases and then decreases. The variation of the magnetic moment with Zn substitution has been discussed in terms of the distribution of magnetic and non-magnetic ions over the A and B sub-lattices and their exchange coupling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stability of circulatory elastic systems in the presence of magnetic damping.

The effect of a type of magnetic damping on the stability of equilibrium of some circulatory elastic systems is examined. A simple system with two degrees of freedom is considered first, and a destabilization is found to be caused by the magnetic field. The nature of the destabilization, however, is not identical to that caused by internal viscous damping. The differences and similarities between the two effects are discussed, and the results are also compared with those of linear external viscous damping. A continuous cantilever bar subjected to a follower force at its free end is then examined. It is found that the critical load is independent of the strength of the magnetic field, and is considerably lower than the corresponding critical load in the absence of a magnetic field. Finally, the continuous cantilever is treated approximately by Galerkin's procedure and also by using a two-degree-of-freedom model of the cantilever; the results obtained are qualitatively the same.

Smith, T. E.↗

Features of Formation of the Magnetocaloric Phenomena in Mn{sub 1–} {sub t}Ti{sub t}As and Mn{sub 1–} {sub x}Cr{sub x}NiGe Systems

The magnetocaloric properties of the systems exhibiting magnetic (paramagnetism (PM)–ferromagnetism (FM)) and structural (hexagonal lattice–orthorhombic lattice) transitions separated (overlapped) in temperature are analyzed in terms of a model of interacting parameters of magnetic and structural orders. It is shown that the magnetocaloric characteristics of the system can increase or decrease during overlapping of the structural (P6{sub 3}/mmc–P{sub nma}) and magnetic (PM–FM) transitions in the dependence of the character of combination of the low-symmetric orthorhombic (P{sub nma}) and high-symmetric hexagonal (P6{sub 3}/mmc) phases with a ferromagnetic order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal Analysis of a Helical Superconducting Undulator Cryostat

A novel cryocooler-cooled helical superconducting undulator (HSCU) was built and installed in the Advanced Photon Source (APS) storage ring and has been in operation since January 2018. The new cryostat for the HSCU is a major improvement of the cryogenic system used for the existing APS planar superconducting undulators. In both systems, superconducting magnets are cooled independently from the beam chamber by liquid helium (LHe) passing through a channel in the magnet/mold assembly. The original planar undulator cryostat consists of three thermal circuits: the outer shield circuit to cool both the warm part of the magnet current leads and the outer shield, the beam chamber cooling circuit to cool the beam chamber and the inner shield, and the magnet cooling circuit to cool the magnets and the LHe tank. On the other hand, the new system consists of only two thermal circuits: the thermal shield circuit to cool the beam chamber, the shield, and the warm part of the magnet leads; and the magnet cooling circuit to cool the LHe tank and the magnet/mold assembly. An finite element analysis-based thermal model of the new HSCU cryostat was developed while the cryogenic performance of the HSCU was measured in a series of standalone tests as well as after installation in the storage ring. This paper presents a thermal analysis of the new HSCU cryostat and, in particular, a comparison of calculated and measured temperatures as well as the excess cooling capacity of the new cryostat in static and dynamic (beam-induced heating) modes.

cryocooler↗

High-frequency fluctuation measurements by far-infrared laser Faraday-effect polarimetry-interferometry and forward scattering system on MST

Magnetic fluctuation-induced transport driven by global tearing modes has been measured by Faraday-effect polarimetry and interferometry (phase measurements) in the MST reversed field pinch. However, the role of small-scale broadband magnetic and density turbulence in transport remains unknown. In order to investigate broadband magnetic turbulence, we plan to upgrade the existing detector system by using planar-diode fundamental waveguide mixers optimized for high sensitivity. Initial tests indicate these mixers have ×10 sensitivity improvement compared to currently employed corner-cube Schottky-diode mixers and ×5 lower noise. Compact mixer design will allow us to resolve the wavenumbers up to k ∼ 1–2 cm{sup −1} for beam width w = 1.5 cm and 15 cm{sup −1} for beam width w = 2 mm. The system can also be used to measure the scattered signal (amplitude measurement) induced by both plasma density and magnetic fluctuations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inelastic Neutron Scattering Data for Ba₃Zn(Ru₀.₁Sb₁.₉)O₉

This dataset contains inelastic neutron scattering measurements on the magnetically dilute compound Ba₃Zn(Ru₀.₁Sb₁.₉)O₉, collected at the Spallation Neutron Source using the Cold Neutron Chopper Spectrometer (CNCS) and the SEQUOIA Fine-Resolution Fermi Chopper Spectrometer. The sample consists of nominally 5% magnetic Ru⁵⁺ ions (S = 3/2) randomly substituted into a diamagnetic Sb⁵⁺ matrix. Measurements were performed at base temperature (2–5 K) and 300 K using multiple incident energies (1.00, 3.32, 12.0, and 100 meV) to resolve magnetic excitations from isolated monomers and small Ru clusters (dimers, trimers, etc.). The dataset includes raw event-mode files, momentum- and energy-resolved spectra, and supporting metadata for instrument configuration, sample environment, and reduction parameters.

36 MATERIALS SCIENCE↗

Recovering the Waste Energy from the Electron-Ion Collider Cooling Water Systems

While only a fraction of the electricity required for the EIC goes into the collision itself, most of the energy ultimately ends up being rejected to the environment via the infrastructure cooling systems. The energy utilized by the RF amplifiers, power supplies, magnets, vacuum systems, and cryogenics systems is rejected to the cooling towers that ultimately dissipate the energy to the atmosphere. Current estimates indicate approximately 50 MW of heat is dissipated at a low temperature by the cooling towers. This technical note is prepared to conceptually demonstrate that feasible options exist to recover the low temperature energy from the EIC cooling water systems.

43 PARTICLE ACCELERATORS↗