Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

A nonintrusive laser interferometer method for measurement of skin friction

A method is described for monitoring the changing thickness of a thin oil film subject to an aerodynamic shear stress using two focused laser beams. The measurement is then simply analyzed in terms of the surface skin friction of the flow. The analysis includes the effects of arbitrarily large pressure and skin friction gradients, gravity, and time varying oil temperature. It may also be applied to three dimensional flows with unknown direction. Applications are presented for a variety of flows including two dimensional flows, three dimensional swirling flows, separated flow, supersonic high Reynolds number flows, and delta wing vortical flows.

Monson, D. J.↗

Properties of AKR from an interferometer analysis of the ISEE-1 and -2 plasma wave data

Both ISEE 1 and 2 are equipped with identical wide-band analog plasma wave receivers which makes long baseline interferometry possible. A cross-correlation of the received signals from each spacecraft during periods of intense Auroral Kilometric Radiation (AKR) provides information on the source size of AKR. From the magnitude of the cross-correlation coefficient, measured over baselines from 40 Km to 8000 Km, an upper limit to the statistical source size can be determined. Thirty-five AKR events at 125 kHz are being analyzed. Preliminary results indicate that the apparent source sizes are smaller than .1 Re.

Baumback, M. M.↗

Stable and rugged etalon for the Dynamics Explorer Fabry-Perot interferometer. II - Performance

The etalon is shown to remain stable to less than 5-m/sec equivalent wind over one orbit and less than 100 m/sec over several months in orbit. The thermal stability considerations for the highly stable etalon are discussed, including the passive thermal control used in flight. The various physical processes which give rise to drifts in the peak transmission wavelength are quantified, and the kinematic mount used to isolate the etalon from large incremental forces caused by changes in the thermal environment is presented. The performance of the etalon in its flight configuration is evaluated.

Killeen, T. L.↗

A nonintrusive laser interferometer method for measurement of skin friction

A method is described for monitoring the changing thickness of a thin oil film subject to an aerodynamic shear stress using two focused laser beams. The measurement is then simply analyzed in terms of the surface skin friction of the flow. The analysis includes the effects of arbitrarily large pressure and skin friction gradients, gravity, and time varying oil temperature. It may also be applied to three dimensional flows with unknown direction. Applications are presented for a variety of flows, including two dimensional flows, three dimensional swirling flows, separated flow, supersonic high Reynolds number flows, and delta wing vortical flows. Previously announced in STAR as N83-12393

Monson, D. J.↗

Interferometer Detects Acoustic Emissions in Composites

Embedded single-mode optical fibers sample internal-stress fields directly. Statically loaded composite matrix emits pulsed ultrasonic waves which mechanically modulate embedded fiber and phase-modulate transmitted optical field. Modulation detected by optical interferometry and Fourier optical processing converted to electronic signal proportional to acoustic field amplitude integated along length of fiber embedded in specimen. Technique used for measurements of both high- and low-frequency CW acoustic fields as well as high-frequency transients.

Cantrell, J. H.↗

A study of a space-station-associated multiple spacecraft Michelson spatial interferometer

One approach to Michelson spatial interferometry at optical wavelengths involves use of an array of spacecraft in which two widely-separated telescopes collect light from a star and direct it to a third, centrally-located, device which combines the beams in order to detect and measure interference fringes. The original version of a spacecraft array for Michelson spatial interferometry (SAMSI) was modified so that the system uses the fuel resupply capability of a space station. The combination of this fuel resupply capability with a method of obtaining image Fourier transform phase information, necessary for full image reconstruction, permits SAMSI to be used to synthesize images equivalent to those produced by huge apertures in space. Synthesis of apertures in the 100 to 500 meter range is discussed. Reconstruction can be performed to a visual magnitude of at least 8 for a 100 A passband in 9 hours. Data are simultaneously collected for image generation from 0.1 micron to 18 microns. In the one-dimensional mode, measurements can be made every 90 minutes (including acquisition and repointing time) for objects as faint as 19th magnitude in the visible.

Stachnik, R. V.↗

Spatial interferometry for white light processing: The coherence interferometer

An optical systems design approach for a parallel optical processor that has an information throughput capacity in excess of one petabit per second is discussed. This system enables predetection processing of white light, passively illuminated scenes. Integrated with a programmable Van der Lugt filter, this system is an effective data compression method. A program to implement this parallel optical processing by interferometry system is discussed.

Breckinridge, J. B.↗

Ground-based observations of equatorial thermosphere dynamics with a Fabry-Perot interferometer

Fabry-Perot determinations of thermospheric temperatures from 630.0 nm nightglow line width measurements were carried out for the period April to August, 1983. The nightly variation of the thermospheric temperature measured on 53 nights is compared with MSIS model predictions and found to agree occasionally with the model but, on the average, to exceed model predictions by approximately 180 K. The largest differences, 400 to 500 K occur during strongly increasing geomagnetic activity. Significant differences occur both during high geomagnetic/low solar activity and during low geomagnetic/high solar activity.

Meriwether, J. W., Jr.↗

A real-time interferometer technique for compressible flow research

Strengths and shortcomings in the application of interferometric techniques to transonic flow fields are examined and an improved method is elaborated. Such applications have demonstrated the value of interferometry in obtaining data for compressible flow research. With holographic techniques, interferometry may be applied in large scale facilities without the use of expensive optics or elaborate vibration isolation equipment. Results obtained using holographic interferometry and other methods demonstrate that reliable qualitative and quantitative data can be acquired. Nevertheless, the conventional method can be difficult to set up and apply, and it cannot produce real-time data. A new interferometry technique is investigated that promises to be easier to apply and can provide real-time information. This single-beam technique has the necessary insensitivity to vibration for large scale wind tunnel operations. Capabilities of the method and preliminary tests on some laboratory scale flow fluids are described.

Bachalo, W. D.↗

QUASAT: An orbiting very long baseline interferometer program using large space antenna systems

QUASAT, which stands for QUASAR SATELLITE, is the name given to a new mission being studied by NASA. The QUASAT mission concept involves a free flying Earth orbiting large radio telescope, which will observe astronomical radio sources simultaneously with ground radio telescopes. The primary goal of QUASAT is to provide a system capable of collecting radio frequency data which will lead to a better understanding of extremely high energy events taking place in a variety of celestial objects including quasars, galactic nuclei, interstellar masers, radio stars and pulsars. QUASAT's unique scientific contribution will be the increased resolution in the emission brightness profile maps of the celestial objects.

Jordan, J. F.↗

Superconducting electromagnetic actuators for astronomical Fabry-Perot interferometers

Two types of superconducting electromagnetic actuators linear and angular - for precise control of Fabry-Perot spectrometer etalons at liquid helium temperature were manufactured and tested successfully. The linear displacement unit (45 Newtons/Amp) has maximum travel of + or - 44 microns with off-axis deviation of less than 1.5 arcseconds for 15 microns path. The angular unit has maximum tilt of + or - 8 arcminutes and can maintain parallelism of two etalons to better than 0.3 arcsecond of angle by compensating the differential contraction upon cooling and off-axis deviation of the linear displacement unit. These actuators are proving especially useful in low temperature infrared instrumentation where other choices, such as piezoelectric crystals, fail and where essentially zero power dissipation permits low infrared backgrounds to be maintained along with long cryogenic lifetimes.

Nishimura, T.↗

Precision geodesy using the Mark-III very-long-baseline interferometer system

Very-long-baseline interferometry (VLBI) has been used to make precise measurements of the vector separation between widely separated antennas. The system for acquiring and processing VLBI data known as Mark-III is described. Tests of the system show it to have millimeter-level accuracy on short baselines; measurements of baselines longer than a few hundred kilometers suggest that accuracy is limited by the uncertainty in the calibration of tropospheric path delay to the level of a few centimeters. VLBI experiments conducted between 1976 and 1983 have demonstrated the stability of the North American plate by showing that there is no change in the distance between eastern California and Massachusetts at the level of a few millimeters per year or greater. Experiments made from 1980 to 1984 indicate that the distance from Massachusetts to Sweden is increasing by 1.7 + or - 1 cm/year where the quoted standard deviation includes the estimated effects of systematic errors.

Clark, T. A.↗

Remote displacement measurement using a passive interferometer with a fiber-optic link

Remote displacement measurement is demonstrated using a Fabry-Perot cavity with a multimode optical fiber link. The sensing cavity modulates, as a function of its length, the spectrum of a light-emitting diode (LED). The light returns via the fiber and is analyzed by a tunable reference cavity. A closed-loop control causes the reference cavity to track the sensing cavity length within 2 x 10 to the -12th m. Displacement range is 2 x 10 to the -6th m. The reference cavity length is measured interferometrically, using a laser, to obtain the sensing cavity length. Advantages of this sensing technique include compatibility with multimode fiber-optic components, high immunity to optical losses, and large dynamic range.

Beheim, G.↗

Use of gamma ray radiation to parallel the plates of a Fabry-Perot interferometer

The use of gamma radiation to parallel the plates of a Fabry-Perot etalon is examined. The method for determining the etalon parallelism, and the procedure for irradiating the posts are described. Changes in effective gap for the etalon over the surface are utilized to measure the parallelism of the Fabry-Perot etalon. An example in which this technique is applied to an etalon of fused silica plates, which are 132 mm in diameter and coded with zinc sulfide and cryolite, with Zerodur spaces 2 cm in length. The effect of the irradiation of the posts on the thermal performance of the etalon is investigated.

Skinner, Wilbert R.↗

A Fabry-Perot interferometer for accurate measurement of temporal changes in stellar Doppler shift

The scrambling of incident light by an optical filter, and the stability obtainable through wavelength calibration by means of a tilt-tunable Fabry-Perot etalon, allow the accurate observation of Doppler shift changes in stellar absorption lines. Distinct, widely spaced monochromatic images of the entrance aperture are formed in the focal plane of the camera through a sampling of about 350 points on the profile of the stellar spectrum by successive orders of interferometric transmission through the etalon. Changes in Doppler shift modify the relative intensities of these images, in proportion to the slope of the spectral profile at each point sampled.

Mcmillan, R. S.↗