Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Polarization rotation in a ferroelectric BaTiO 3 film through low-energy He-implantation

Domain engineering in ferroelectric thin films is crucial for next-generation microelectronic and photonic technologies. Here, a method is demonstrated to precisely control domain configurations in BaTiO 3 thin films through low-energy He ion implantation. The approach transforms a mixed ferroelectric domain state with significant in-plane polarization into a uniform out-of-plane tetragonal phase by selectively modifying the strain state in the film’s top region. This structural transition significantly improves domain homogeneity and reduces polarization imprint, leading to symmetric ferroelectric switching characteristics. The demonstrated ability to manipulate ferroelectric domains post-growth enables tailored functional properties without compromising the coherently strained bottom interface. The method’s compatibility with semiconductor processing and ability to selectively modify specific regions make it particularly promising for practical implementation in integrated devices. This work establishes a versatile approach for strain-mediated domain engineering that could be extended to a wide range of ferroelectric systems, providing new opportunities for memory, sensing, and photonic applications where precise control of polarization states is essential.

36 MATERIALS SCIENCE↗

Enhanced Electrical Activation in In-Implanted Si 0.35 Ge 0.65 by C Co-Doping

In this report, we have achieved a significant increase in the electrically active dopant fraction in Indium (In)-implanted Si 0.35 Ge 0.65 , by co-doping with the isovalent element Carbon (C). Electrical measurements have been correlated with X-ray absorption spectroscopy to determine the electrical properties and the In atom lattice location. With C+In co-doping, the solid solubility of In in Si 0.35 Ge 0.65 was at least tripled from between 0.02 and 0.06 at% to between 0.2 and 0.6 at% as a result of C–In pair formation, which suppressed In metal precipitation. A dramatic improvement of electrical properties was thus attained in the co-doped samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Deterministic nanoscale quantum spin-defect implantation and diffraction strain imaging

Abstract Local crystallographic features negatively affect quantum spin defects by changing the local electrostatic environment, often resulting in degraded or varied qubit optical and coherence properties. Few tools exist that enable the deterministic synthesis and study of such intricate systems on the nano-scale, making defect-to-defect strain environment quantification difficult. In this paper, we highlight state-of-the-art capabilities from the U.S. Department of Energy’s Nanoscale Science Research Centers that directly address these shortcomings. Specifically, we demonstrate how complementary capabilities of nano-implantation and nano-diffraction can be used to demonstrate the quantum relevant, spatially deterministic creation of neutral divacancy centers in 4H silicon carbide, while investigating and characterizing these systems on the ≤ 25 nm scale with strain sensitivities on the order of 1 × 10 − 6 , relevant to defect formation dynamics. This work lays the foundation for ongoing studies into the dynamics and deterministic formation of low strain homogeneous quantum relevant spin defects in the solid state.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Multi-beam RF Accelerators for Ion Implantation

We report on the development of a radio frequency (RF) linear accelerator (linac) for multiple-ion beams that is made from stacks of low cost wafers. The accelerator lattice is comprised of RF-acceleration gaps and electrostatic quadrupole focusing elements that are fabricated on 4' wafers made from printed circuit board or silicon. We demonstrate ion acceleration with an effective gradient of about 0.5MVm-1 with an array of 3 × 3 beams. The total ion beam energies achieved to date are in the 10 keV range with total ion currents in tests with noble gases of ~0.1mA. We discuss scaling of the ion energy (by adding acceleration modules) and ion currents (with more beams) for applications of this multi-beam RF linac technology to ion implantation and surface modification of materials.

Seidl, Peter A.↗

Survival, growth and tag retention of juvenile European eel ( Anguilla anguilla L.) with implanted 12 mm passive integrated transponder tags and acoustic tags

To evaluate the efficiency of tagging juvenile European eels with implanted 12 mm passive integrated transponder (PIT) tags or Eel/Lamprey acoustic transmitters (ELATs), the authors studied tag retention, survival and growth of eels (7–25 g). Experimental eels were obtained from an eel farm, tagged and then released in a series of shallow dug-out ponds with a surface area of c. 200 m 2 . Tagged and control eels were distributed evenly, with 50 tagged and 50 control eels in each of four ponds, giving a total of 200 tagged and 200 control eels mixed. After 76 days, the ponds were drained, and eels were sampled and measured. A total of 344 eels (86%) were recaptured, indicating high survival. Tag retention was 99% as only one of the recaptured PIT-tagged eels had lost the tag and none of the ELAT tagged. The results demonstrated that tagging juvenile eels >16 cm with these small tags is indeed feasible. The growth of tagged and control fish was differentiated but generally low in length and negative in mass but did not differ between the three groups.

54 ENVIRONMENTAL SCIENCES↗

Technologies for Prolonging Cardiac Implantable Electronic Device Longevity

Prolonged longevity of cardiac implantable electronic devices (CIEDs) is needed not only as a passive response to match the prolonging life expectancy of patient recipients, but will also actively prolong their life expectancy by avoiding/deferring the risks (and costs) associated with device replacement. CIEDs are still exclusively powered by nonrechargeable primary batteries, and energy exhaustion is the dominant and an inevitable cause of device replacement. The longevity of a CIED is thus determined by the attrition rate of its finite energy reserve. The energy available from a battery depends on its capacity (total amount of electric charge), chemistry (anode, cathode, and electrolyte), and internal architecture (stacked plate, folded plate, and spiral wound). The energy uses of a CIED vary and include a background current for running electronic circuitry, periodic radiofrequency telemetry, high‐voltage capacitor reformation, constant ventricular pacing, and sporadic shocks for the cardiac resynchronization therapy defibrillators. The energy use by a CIED is primarily determined by the patient recipient's clinical needs, but the energy stored in the device battery is entirely under the manufacturer's control. A larger battery capacity generally results in a longer‐lasting device, but improved battery chemistry and architecture may allow more space‐efficient designs. Armed with the necessary technical knowledge, healthcare professionals and purchasers will be empowered to make judicious selection on device models and maximize the utilization of all their energy‐saving features, to prolong device longevity for the benefits of their patients and healthcare systems.

LAU, ERNEST W.↗

Implantable MOSFET detectors: Evaluation of a new design

The authors have studied the performance of a new version of the implantable MOSFET detector designed for clinical use. Detectors were irradiated under 6- and 18-MV beams in water at body temperature to the calibration dose of 200 cGy/fraction for 20 daily fractions to determine their response and reproducibility. Additional measurements were performed in a solid phantom under 6-MV irradiation at room temperature to daily doses of 100, 150, 200, 250, 400 and 600 cGy/fraction. Finally, the angular dependence with respect to rotation about the detector's longitudinal axis was studied. At body temperature, the detectors were found to have an average response within {+-}3% of the calibration dose with a standard deviation of 2% or less. At room temperature, doses lower than the calibration dose led to a slight overresponse while doses higher than the calibration dose led to a slight underresponse. Angular dependence was not significant, on average within 1.2% of the mean. When used as specified by the manufacturer, these detectors should provide data useful to verify the delivered dose for external beam radiation therapy within a certain tolerance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Response of an implantable MOSFET dosimeter to {sup 192}Ir HDR radiation

New in vivo dosimetry methods would be useful for clinical HDR brachytherapy. An implantable MOSFET Dose Verification System designed by Sicel Technologies, Inc. was examined for use with {sup 192}Ir HDR applications. This investigation demonstrated that varying the dose rate from 22 to 84 cGy/min did not change detector response. The detectors exhibited a higher sensitivity to {sup 192}Ir energies than {sup 60}Co energies. A nonlinear accumulated dose effect was characterized by three third-order polynomials fit to data from detectors placed at three different distances from the source. The detectors were found to have minimal rotational angular dependence. A strong longitudinal angular dependence was found when the detector's copper coil and electronics assembly were aligned between the MOSFETs and incident radiation. This orientation showed a 16% decrease in response relative to other orientations tested.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of an implantable MOSFET dosimeter designed for use with hypofractionated external beam treatments and its applications for breast and prostate treatments

Purpose: An implantable metal-oxide semiconductor field effect transistors-based dosimeter has recently been developed for the in vivo monitoring of hypofractionated radiotherapy. This DVS-HFT dosimeter is designed for fraction sizes of 340-950 cGy and can also be used for bis in die fraction monitoring. The current work reports on the testing and evaluation of this dosimeter, including both its basic characteristics as well as its performance during simulated clinical treatment plans. Methods: The authors tested the dose rate dependence of this dosimeter (300 MU/min versus 600 MU/min), the treatment time dependence (4 min per treatment versus up to 60 min per treatment), and the dose and energy dependence (6 and 18 MV irradiations of 700-900 cGy per fraction). Additionally, they irradiated the detectors in-phantom with breast and prostate hypofractionated treatments. Results: The detectors showed no significant dose rate, treatment time, energy, or dose dependence. Furthermore, the detectors were found to perform within manufacturer tolerances for all hypofractionated treatments examined, accurately reporting the measured dose (average disagreement of - 0.65%). Conclusions: These dosimeters appear well suited for in vivo monitoring of hypofractionated radiotherapy doses, and thereby, have the potential to improve patient care.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-145: Effects of Temporary Tachytherapy Inhibition Magnet On MOSFET Dose Measurements of Cardiovascular Implantable Electronic Devices (CIED) in Radiation Therapy Patients

Purpose: To determine the effects of temporary tachytherapy inhibition magnet on MOSFET dose measurements of cardiovascular implantable electronic devices (CIED) in radiation therapy patients. Methods: Infield and peripheral MOSFET dose measurements with 6MV photon beams were performed to evaluate dose to a CIED in the presence of a doughnut shaped temporary tachytherapy inhibition magnet. Infield measurements were done to quantify the effects of the magnetic field alone and shielding by the magnet. MOSFETs were placed inside a 20×20cm{sup 2} field at a depth of 3cm in the isocentre plane in the presence and absence of the magnet. Peripheral dose measurements were done to determine the impact of the magnet on dose to the CIED in a clinical setting. These measurements were performed at the centre, under the rim and half way between a 10×10cm{sup 2} field edge and the magnet with MOSFETS placed at the surface, 0.5cm and 1cm depths in the presence and absence of the magnet. Results: Infield measurements showed that effects of magnetic field on the MOSFET readings were within the 2% MOSFET dose measurement uncertainty; a 20% attenuation of dose under the magnet rim was observed. Peripheral dose measurements at the centre of the magnet show an 8% increase in surface dose and a 6% decrease in dose at 1cm depth. Dose under the magnet rim was reduced by approximately 68%, 45% and 25% for MOSFET placed at 0.0, 0.5 and 1.0cm bolus depths, respectively. Conclusions: The magnetic field has an insignificant effect on MOSFET dose measurements. Dose to the central region of CIED represented by centre of the magnet doughnut increases at the surface, and decreases at depths due to low energy scattering contributions from the magnet. Dose under the magnet rim, representing CIED edges, decreased significantly due to shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvement of registration accuracy in accelerated partial breast irradiation using the point-based rigid-body registration algorithm for patients with implanted fiducial markers

Purpose: To investigate image-registration errors when using fiducial markers with a manual method and the point-based rigid-body registration (PRBR) algorithm in accelerated partial breast irradiation (APBI) patients, with accompanying fiducial deviations. Methods: Twenty-two consecutive patients were enrolled in a prospective trial examining 10-fraction APBI. Titanium clips were implanted intraoperatively around the seroma in all patients. For image-registration, the positions of the clips in daily kV x-ray images were matched to those in the planning digitally reconstructed radiographs. Fiducial and gravity registration errors (FREs and GREs, respectively), representing resulting misalignments of the edge and center of the target, respectively, were compared between the manual and algorithm-based methods. Results: In total, 218 fractions were evaluated. Although the mean FRE/GRE values for the manual and algorithm-based methods were within 3 mm (2.3/1.7 and 1.3/0.4 mm, respectively), the percentages of fractions where FRE/GRE exceeded 3 mm using the manual and algorithm-based methods were 18.8%/7.3% and 0%/0%, respectively. Manual registration resulted in 18.6% of patients with fractions of FRE/GRE exceeding 5 mm. The patients with larger clip deviation had significantly more fractions showing large FRE/GRE using manual registration. Conclusions: For image-registration using fiducial markers in APBI, the manual registration results in more fractions with considerable registration error due to loss of fiducial objectivity resulting from their deviation. The authors recommend the PRBR algorithm as a safe and effective strategy for accurate, image-guided registration and PTV margin reduction.

60 APPLIED LIFE SCIENCES↗

High-voltage (900 V) 4 H-SiC Schottky diodes with a boron-implanted guard p-n junction

High-voltage (900 V) 4H-SiC Schottky diodes terminated with a guard p-n junction were fabricated and studied. The guard p-n junction was formed by room-temperature boron implantation with subsequent high-temperature annealing. Due to transient enhanced boron diffusion during annealing, the depth of the guard p-n junction was equal to about 1.7 {mu}m, which is larger by approximately 1 {mu}m than the projected range of 11 B ions in 4H-SiC. The maximum reverse voltage of fabricated 4H-SiC Schottky diodes is found to be limited by avalanche breakdown of the planar p-n junction; the value of the breakdown voltage (910 V) is close to theoretical estimate in the case of the impurity concentration N = 2.5 Multiplication-Sign 10{sup 15} cm{sup -3} in the n-type layer, thickness of the n-type layer d = 12.5 {mu}m, and depth of the p-n junction r{sub j} = 1.7 {mu}m. The on-state diode resistance (3.7 m{Omega} cm{sup 2}) is controlled by the resistance of the epitaxial n-type layer. The recovery charge of about 1.3 nC is equal to the charge of majority charge carriers that are swept out of an epitaxial n-type layer under the effect of a reverse voltage.

36 MATERIALS SCIENCE↗

Diffusion of implanted sodium in oxygen-containing silicon

The effect of oxygen on diffusion of sodium implanted into silicon is studied for the first time in the temperature range from 500 to 850{sup o}C. A high-resistivity p-Si ({rho} > 1 k{omega} cm) grown by the Czochralski method in a magnetic field (mCz) with the oxygen concentration {approx}3 x 10{sup 17} cm{sup -3} was used. For comparison, we used silicon grown by the crucibleless floating zone method (fz). Temperature dependences of the effective diffusion coefficient of sodium in the mCz-Si and fz-Si crystals were determined and written as D{sub mCz}[cm{sup 2}/s] = 1.12exp(-1.64 eV/kT) cm{sup 2}/s and D{sub fz}[cm{sup 2}/s] = 0.024exp(-1.29 eV/kT) cm{sup 2}/s, respectively. It is assumed that larger values of diffusion parameters in oxygen-containing silicon are caused by formation of complex aggregates that contain sodium and oxygen atoms.

36 MATERIALS SCIENCE↗

A DLTS study of 4H-SiC-based p-n junctions fabricated by boron implantation

Deep-level transient spectroscopy (DLTS) has been used to study p-n junctions fabricated by implantation of boron into epitaxial 4H-SiC films with n-type conductivity and the donor concentration (8-9) Multiplication-Sign 10{sup 14} cm{sup -3}. A DLTS signal anomalous in sign is observed; this signal is related to recharging of deep compensating boron-involved centers in the n-type region near the metallurgical boundary of the p-n junction.

36 MATERIALS SCIENCE↗

Negative annealing in silicon after the implantation of high-energy sodium ions

The implantation of sodium ions with an energy of 300 keV is carried out into high-resistivity p-Si. The annealing of defects at T{sub ann} = 350–450°C and related activation of atoms (the latter occurs at the “tail” of atom distribution) are described by a first-order reaction. At T{sub ann} = 450–525°C and irrespective of the ion dose, negative annealing is observed; this annealing is accompanied by an appreciable increase in the surface resistance ρ{sub s}. According to estimations, the activation energy of this process amounts to ~2 eV. It is our opinion that the annealing is related to the precipitation of sodium donor atoms, which occurs at a depth exceeding by two–three times the projected range R{sub p} of ions. The annealing of defects at T{sub ann} = 525–700°C, which leads to a further decrease in ρ{sub s}, features an activation energy of ~2.1 eV. The hypothesis that the “tail” in the profiles of sodium atoms measured by secondary-ion mass spectroscopy is due to the diffusion of these atoms from the walls of the crater to its center is verified. It is shown that this process is not implemented since the profiles of sodium atoms measured at room temperature do not differ from those measured at–140°C.

36 MATERIALS SCIENCE↗

Influence of measurement temperature on the luminescence properties of (113) defects in oxygen-implanted silicon

Influence of the measurement temperature in the range 5–130 K on the photoluminescence spectra of (113) defects in Si implanted with 350-keV oxygen ions at doses of 3.7 × 10{sup 14} cm{sup –2} and annealed at a temperature of 700°C for 1 h in a chlorine-containing atmosphere is studied. The temperature dependence of the line intensity is characterized by portions of intensity increase with an activation energy of 23.1 meV and intensity quenching with activation energies of 41.9 and 178.3 meV. With increasing temperature, the lines are shifted to longer wavelengths and their FWHM increases.

36 MATERIALS SCIENCE↗

Performance assessment of bi-directional knotless tissue-closure devices in juvenile Chinook salmon surgically implanted with acoustic transmitters

Acoustic transmitters used in survival and telemetry studies are often surgically implanted in fish. While this is a well-established method, it has the potential to affect health, behavior, and survival, thus affecting study results. Much research has been done to try to minimize the harmful effects caused by the transmitter and tagging process. In 2009, we first investigated the use of a bi-directional knotless (barbed) suture material in juvenile Chinook salmon (Oncorhynchus tshawytscha). We found that it resulted in higher tag retention than the simple interrupted suture pattern; however, the occurrence of ulceration and redness increased. The objective of this study was to refine the suturing patterns of the bi-directional knotless suture and retest suture performance in juvenile Chinook salmon. We tested the bi-directional suture using 3 different suture patterns and two needle types: 6-Point (12-mm needle circumference), Wide “N” (12-mm needle circumference), Wide “N” Knot 12 (12-mm needle circumference), and Wide “N” Knot 18 (18-mm needle circumference).

bio-effect↗