Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High pressure instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Long Term Measurement of the Vapor Pressure of Gold in the Au-C System

Incorporating the {Au(s,l) + graphite} reference in component activity measurements made with the multiple effusion-cell vapor source mass spectrometry (multicell KEMS) technique provides a fixed temperature defining ITS-90 (T(sub mp)(Au) = 1337.33K) and a systematic method to check accuracy. Over a 2 year period delta H sub(298)Au was determined by the 2nd and 3rd law methods in 25 separate experiments and were in the ranges 362.2 plus or minus 3.3 kJmol(sup -1) and 367.8 plus or minus 1.1 kJmol(sup -1), respectively. This 5 kJmol-1 discrepancy is transferred directly to the measured activities. This is unacceptable and the source of this discrepancy needs to be understood and corrected. Accepting the 2nd law value increases p(Au) by about 50 percent, brings the 2nd and 3rd law values into agreement and removes the T dependence in the 3rd law values. While compelling, there is no way to independently determine instrument sensitivities, S(sub Au), with T in a single experiment with KEMS. This lack of capability is stopping a deeper understanding of this problem. In addition, the Au-C phase diagram suggests a eutectic invariant reaction: L-Au(4.7at%C) = FCC-Au(0.08at%C) + C(graphite) at T(sub e) approximately 1323K. This high C concentration in Au(l) must reduce p(Au) in equilibrium with {Au(s,l) + graphite} and raises some critical questions about the Gibbs free energy functions of Au(s,l) and the Au fixed point (T(sub mp)(Au) = 1337.33K) which is always measured in graphite.

Copland, Evan H.↗

Skin Friction Extracted from Surface Pressure in Incident Shock-Wave/Boundary-Layer Interaction

High-resolution skin-friction fields are extracted from pressure-sensitive paint (PSP) data obtained in shock-wave/boundary-layer interaction (SWBLI). The method of extracting skin friction from surface pressure is described, including the fundamental relation between skin friction and surface pressure, the variational method, error analysis, and an approximate iterative method. The proposed method is based on a coupling relation between skin friction and surface pressure, where the boundary enstrophy flux is suitably modeled or approximated. This method is applied to unsteady PSP data obtained in incident SWBLIs at Mach 2.5 for different Reynolds numbers, revealing the skin-friction structures of the flows: particularly, the separation bubble induced by the incident shock wave. The extracted results are in good agreement with the data obtained by the surface-stress-sensitive film.

skin friction↗

Eye Surgery Light

During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a springloaded plexiglass "flapper." The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

Source record↗

NEA Scout and Lunar Flashlight: Two NearTerm Interplanetary CubeSat Missions

NASA is developing two small satellite missions as part of the Advanced Exploration Systems (AES) Program, both of which will use a solar sail to enable their scientific objectives. Solar sails reflect sunlight from a large, mirror‐like sail made of a lightweight, highly reflective material to provide thrust. This continuous photon pressure provides propellantless thrust, allowing for very high delta V maneuvers in space. Lunar Flashlight, managed by the NASA Jet Propulsion Laboratory, will search for and map volatiles in permanently shadowed lunar craters using a solar sail as a gigantic mirror to steer sunlight into them, then examine the reflected light with a spectrometer. The Lunar Flashlight spacecraft will also use the solar sail to maneuver into a lunar polar orbit. The mission will demonstrate a low‐cost capability to explore, locate and estimate the size and composition of ice deposits on the Moon. The Near Earth Asteroid (NEA) Scout mission, managed by the NASA Marshall Space Flight Center will survey and image a Near Earth Asteroid for possible future human exploration using a smallsat propelled by a solar sail. Detections of NEAs are expected to grow in the near future, offering increasing target opportunities. Obtaining and analyzing relevant data about these bodies via robotic precursors before committing a crew to visit them is essential. The NEA Scout spacecraft is nearly identical to the one being developed for Lunar Flashlight, with the science instrument package being the primary difference. The NEA Scout solar sail will provide the primary propulsion taking the 6U cubesat from near the Earth to its final asteroid destination and the Lunar Flashlight sail will provide the propulsion necessary for its spacecraft to enter lunar orbit. Both projects will use an 85 m2 solar sail developed by NASA MSFC. The NEA Scout and Lunar Flashlight flight systems are based on a 6U cubesat form factor, with a stowed envelope of 10 x 20 x 30 cm and a mass of less than 12 kg. The solar sail for NEA Scout and Lunar Flashlight will be based on the technology developed and flown by the NASA NanoSail‐D and The Planetary Society's Lightsail‐A. Four 7 m stainless steel booms wrapped on two spools (two overlapping booms per spool) will be motor deployed and pull the sail from its stowed volume. The sail material will be 3 micron CP1, an aluminized polyimide that was extensively tested for solar sail applications. The sail will spooled rather than Z‐folded. This paper will describe both the Lunar Flashlight and NEA Scout missions and their solar sails.

Johnson, Les↗

Overview of the 2nd Gen 3.7m HIAD Static Load Test

To support NASAs long term goal of landing humans on Mars, technologies which enable the landing of heavy payloads are being developed. Current entry, decent, and landing technologies are not practical for human class payloads due to geometric constraints dictated by current launch vehicle fairing limitations. Therefore, past and present technologies are now being explored to provide a mass and volume efficient solution to atmospheric entry, including Hypersonic Inflatable Aerodynamic Decelerators (HIADs). In October of 2014, a 3.7m HIAD inflatable structure with an integrated flexible thermal protection sys-tem (F-TPS) was subjected to a static load test series to verify the designs structural performance. The 3.7m HIAD structure was constructed in a 70 deg sphere-cone stacked-toroid configuration using eight inflatable tori, which were joined together using adhesives and high strength textile webbing to help distribute the loads throughout the inflatable structure. The inflatable structure was fabricated using 2nd generation structural materials that permit an increase in use temperature to 400 C+ as compared to the 250 C limitation of the 1st generation materials. In addition to the temperature benefit, these materials also offer a 40 reduction in structure mass. The 3.7m F-TPS was fabricated using high performance materials to protect the inflatable structure from heat loads that would be seen during atmospheric entry. The F-TPS was constructed of 2nd generation TPS materials increasing its heating capability from 35W sq cm to over 100W sq cm. This test article is the first stacked-torus HIAD to be fabricated and tested with a 70 deg sphere-cone. All previous stacked-torus HIADs have employed a 60o sphere-cone. To perform the static load test series, a custom test fixture was constructed. The fixture consisted of a structural tub rim with enough height to allow for dis-placement of the inflatable structure as loads were applied. The tub rim was attached to the floor to provide an airtight seal. The center body of the inflatable structure was attached to a pedestal mount as seen in Figure 1. Using an impermeable membrane seal draped over the test article, partial vacuum was pulled beneath the HIAD, resulting in a uniform static pressure load applied to the outer surface. During the test series an extensive amount of instrumentation was used to characterize deformed shape, shoulder deflection, strap loads, and cord loads as a function of structural configuration and applied static load. In this overview, the 3.7m HIAD static load test series will be discussed in detail, including the 3.7m HIAD inflatable structure and flexible TPS design, test setup and execution, and finally results and conclusions from the test series.

HIAD↗

An Efficient Approach to Collect Inlet Characterization Data

This report considers a novel process to acquire performance data for supersonic mixed compression inlets that is faster, and therefore less costly, than the previous one. In the previous process, measurements were recorded in discrete increments. The backpressuring actuator was advanced, there was a pause to allow for airflow fluctuations to diminish, and then the measurements were recorded. While this process was methodical, reliable and accurate, it consumed significant wind-on time. In general, high-speed wind tunnels are expensive to operate considering maintenance, energy and human resource requirements. Furthermore, many facilities, such as blowdown wind tunnels, are limited in the duration that they can maintain the desired test condition. Consequently, a quick method to collect the measurements is desired. A favored approach has the actuator moving in a continuous fashion with measurements recorded as the actuator continuously progresses through the increment points. This approach, identified as the dynamic inlet characteristic data acquisition procedure, uses in situ dynamic high-speed pressure sensors to measure pressure signals. While faster, continuous movement adds dynamic effects to the data. To better understand these dynamic effects and other potential influences, a study was undertaken to compare wind tunnel measurements taken at discrete actuator position points with data gathered during continuous actuator movement. Specially, plots of inlet pressure recovery versus mass capture ratio, or total pressure characteristic curves, were examined. The data were measured during experiments in the NASA Glenn Research Center Abe Silverstein 10- by 10-Foot Supersonic Wind Tunnel (SWT) with an inlet propulsion test article. In this report, the wind tunnel experiment and the study objectives are described. The processes to reduce the data and for analysis are explained. A discussion of the results along with features noted in the data is given. Finally, conclusions from this study that may be used to guide future wind tunnel experiment planning are presented.

Inlet↗

Non-invasive characterization of complex coronary lesions

Conventional invasive diagnostic imaging techniques do not adequately resolve complex Type B and C coronary lesions, which present unique challenges, require personalized treatment and result in worsened patient outcomes. These lesions are often excluded from large-scale non-invasive clinical trials and there does not exist a validated approach to characterize hemodynamic quantities and guide percutaneous intervention for such lesions. This work identifies key biomarkers that differentiate complex Type B and C lesions from simple Type A lesions by introducing and validating a coronary angiography-based computational fluid dynamic (CFD-CA) framework for intracoronary assessment in complex lesions at ultrahigh resolution. Among 14 patients selected in this study, 7 patients with Type B and C lesions were included in the complex lesion group including ostial, bifurcation, serial lesions and lesion where flow was supplied by collateral bed. Simple lesion group included 7 patients with lesions that were discrete, <10mm long and readily accessible. Intracoronary assessment was performed using CFD-CA framework and validated by comparing to clinically measured pressure-based index, such as FFR. Local pressure, endothelial shear stress (ESS) and velocity profiles were derived for all patients. We validates the accuracy of our CFD-CA framework and report excellent agreement with invasive measurements (n=14,R 2 =0.6,p=0.0013). Ultra-high resolution achieved by the model enable physiological assessment in complex lesions and quantify hemodynamic metrics in all vessels up to 1mm in diameter. Importantly, we demonstrate that in contrast to traditional pressure-based metrics, there is a significant difference in the intracoronary hemodynamic forces, such as ESS, in complex lesions compared to simple lesions at both resting and hyperemic physiological states [n = 14, p=0.03]. Higher ESS was observed in the complex lesion group (7.0±4.7 Pa) than in simple lesion group (4.8±3.6 Pa). Complex coronary lesions have higher ESS compared to simple lesions, such differential hemodynamic evaluation can provide much the needed insight into the increase in adverse outcomes for such patients and has incremental prognostic value over traditional pressure-based indices, such as FFR.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experiments at TA-55 have used optical pyrometry to measure temperatures of shocked plutonium on the 40mm gun

Researchers at LANL, along with collaborators from MSTS, have worked for more than a decade to develop and implement an optical pyrometry method to measure the temperature of metals shocked to the high pressures and temperatures. Because traditional shock wave measurements only provide information on the mechanical state of the material, temperature measurements are required to validate and improve equation-of-state (EOS) models for materials. The conditions sampled are complex; commenserate with those found in planetary impacts, and accressed by conventional and nuclear weapons. Optical pyrometry is currently the best available method for inferring the temperature of shocked metals, by careful measurement of the calibrated radiance emitted by a surface at finite temperature. These measurements are difficult often complicated by the short time scales associated with shock wave experiments (<1 µs) coupled with the many sources of non-thermal light (impact flash, fracture light, etc.) that pollutes the radiant light measured from the sample.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Dynamic Rupture Simulations of Caldera Collapse Earthquakes: Effects of Wave Radiation, Magma Viscosity, and Evidence of Complex Nucleation at Kilauea 2018

All instrumented basaltic caldera collapses have generated M w > 5 very long period earthquakes. However, previous studies of source dynamics have been limited to lumped models treating the caldera block as rigid, leaving open questions related to how ruptures initiate and propagate around the ring fault, and the seismic expressions of those dynamics. Here, we present the first 3D numerical model capturing the nucleation and propagation of ring fault rupture, the mechanical coupling to the underlying viscoelastic magma, and the associated seismic wavefield. We demonstrate that seismic radiation, neglected in previous models, acts as a damping mechanism reducing coseismic slip by up to half, with effects most pronounced for large magma chamber volume/ring fault radius or highly compliant crust/compressible magma. Viscosity of basaltic magma has negligible effect on collapse dynamics. In contrast, viscosity of silicic magma significantly reduces ring fault slip. We use the model to simulate the 2018 Kilauea caldera collapse. Three stages of collapse, characterized by ring fault rupture initiation and propagation, deceleration of the downward-moving caldera block and magma column, and post-collapse resonant oscillations, in addition to chamber pressurization, are identified in simulated and observed (unfiltered) near-field seismograms. A detailed comparison of simulated and observed displacement waveforms corresponding to collapse earthquakes with hypocenters at various azimuths of the ring fault reveals a complex nucleation phase for earthquakes initiated on the northwest. Our numerical simulation framework will enhance future efforts to reconcile seismic and geodetic observations of caldera collapse with conceptual models of ring fault and magma chamber dynamics.

58 GEOSCIENCES↗

Eye Surgery Light

During eye surgery, the surgeon uses an illuminating instrument called an opthalmoscope for close examination of the retina or the interior of the eye. Ordinarily, electric power for the head-mounted light is supplied through a cord from an overhead swivel arm or a floor pedestal. Within limits of cord length and swivel arm movement, the surgeon has considerable freedom of motion. But when more than one opthalmoscope is involved, tangling and interference of the power cords becomes a problem. St. Luke's Hospital, Cleveland, Ohio asked Lewis Research Center for assistance in finding a solution. Lewis responded with a battery-powered system that totally frees the surgeon of attached cords and swivels. Borrowing from space technology, Lewis used small, lightweight nickel-cadmium batteries that can deliver high intensity light for an hour and can be recharged overnight. The Opthalmoscope Powerpack consists of eight batteries in three containers affixed to a webbed belt, and a novel on-off switch equipped with a spring-loaded plexiglass 'flapper.' The belt pack is worn underneath the surgical gown and the flapper permits the doctor to activate the switch by elbow pressure. Lewis built five units and they have been in service at St. Luke's Hospital for a year. Used for routine examinations as well as for surgery, they have demonstrated excellent reliability.

Source record↗

An Efficient Approach to Collect Inlet Characterization Data

This report considers a novel process to acquire performance data for supersonic mixed compression inlets that is faster, and therefore less costly, than the previous one. In the previous process, measurements were recorded in discrete increments. The backpressuring actuator was advanced, there was a pause to allow for airflow fluctuations to diminish, and then the measurements were recorded. While this process was methodical, reliable and accurate, it consumed significant wind-on time. In general, high-speed wind tunnels are expensive to operate considering maintenance, energy and human resource requirements. Furthermore, many facilities, such as blowdown wind tunnels, are limited in the duration that they can maintain the desired test condition. Consequently, a quick method to collect the measurements is desired. A favored approach has the actuator moving in a continuous fashion with measurements recorded as the actuator continuously progresses through the increment points. This approach, identified as the dynamic inlet characteristic data acquisition procedure, uses in situ dynamic high-speed pressure sensors to measure pressure signals. While faster, continuous movement adds dynamic effects to the data. To better understand these dynamic effects and other potential influences, a study was undertaken to compare wind tunnel measurements taken at discrete actuator position points with data gathered during continuous actuator movement. Specially, plots of inlet pressure recovery versus mass capture ratio, or total pressure characteristic curves, were examined. The data were measured during experiments in the NASA Glenn Research Center Abe Silverstein 10- by 10-Foot Supersonic Wind Tunnel (SWT) with an inlet propulsion test article. In this report, the wind tunnel experiment and the study objectives are described. The processes to reduce the data and for analysis are explained. A discussion of the results along with features noted in the data is given. Finally, conclusions from this study that may be used to guide future wind tunnel experiment planning are presented.

Data Acquisition↗

Laser-driven ramp-compression experiments on the national ignition facility

This report details the analyses and related uncertainties in measuring longitudinal-stress–density paths in indirect laser-driven ramp equation-of-state (EOS) experiments. Experiments were conducted at the National Ignition Facility (NIF) located at the Lawrence Livermore National Laboratory. The NIF can deliver up to 2 MJ of laser energy over 30 ns and provide the necessary laser power and control to ramp compress materials to TPa pressures (1 TPa = 10 × 10 6 atmospheres). These data provide low-temperature solid-state EOS data relevant to the extreme conditions found in the deep interiors of giant planets. In these experiments, multi-stepped samples with thicknesses in the range of 40–120 µm experience an initial shock compression followed by a time-dependent ramp compression to peak pressure. Interface velocity measurements from each thickness combine to place a constraint on the Lagrangian sound speed as a function of particle velocity, which in turn allows for the determination of a continuous stress–density path to high levels of compressibility. In this report, we present a detailed description of the experimental techniques and measurement uncertainties and describe how these uncertainties combine to place a final uncertainty in both stress and density. Here, we address the effects of time-dependent deformation and the sensitivity of ramp EOS techniques to the onset of phase transformations.

47 OTHER INSTRUMENTATION↗

Giant Outer Transiting Exoplanet Mass (GOT ‘EM) Survey. I. Confirmation of an Eccentric, Cool Jupiter with an Interior Earth-sized Planet Orbiting Kepler-1514

Despite the severe bias of the transit method of exoplanet discovery toward short orbital periods, a modest sample of transiting exoplanets with orbital periods greater than 100 days is known. Long-term radial velocity (RV) surveys are pivotal to confirming these signals and generating a set of planetary masses and densities for planets receiving moderate to low irradiation from their host stars. Here we conduct RV observations of Kepler-1514 from the Keck I telescope using the High Resolution Echelle Spectrometer. From these data, we measure the mass of the statistically validated giant (1.108 ± 0.023 R {sub J}) exoplanet Kepler-1514 b with a 218-day orbital period as 5.28 ± 0.22 M {sub J}. The bulk density of this cool (∼390 K) giant planet is 4.82{sub −0.25}{sup +0.26}g cm{sup −3}, consistent with a core supported by electron degeneracy pressure. We also infer an orbital eccentricity of 0.401{sub −0.014}{sup +0.013} from the RV and transit observations, which is consistent with planet–planet scattering and disk cavity migration models. The Kepler-1514 system contains an Earth-size, Kepler Object of Interest on a 10.5-day orbit that we statistically validate against false-positive scenarios, including those involving a neighboring star. The combination of the brightness (V = 11.8) of the host star and the long period, low irradiation, and high density of Kepler-1514 b places this system among a rare group of known exoplanetary systems and as one that is amenable to continued study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An experimental investigation of surface pressure measurements on an advanced winged entry vehicle at Mach 10

Surface pressure measurements have been made at Mach 10 in air on an instrumented 0.006-scale model of an advanced (control configured) winged entry vehicle. The tests were conducted in the Langley Continuous Flow Hypersonic Tunnel. Data were obtained at 83 surface pressure stations, which include locations on the lower and upper surface centerlines, spanwise positions along the lower and upper surfaces of the wing, the lower surface of the body flap, and radial locations on the fuselage. Data were obtained for angles of attack ranging from zero to 40 deg, sideslip angles of -2 deg to +5 deg, Reynolds numbers of 0.5, 1.0, and 2.0 million per foot, and body-flap deflections of zero, 10, and 20 deg. Test conditions and orifice locations were chosen to correspond directly with those for the heat transfer measurements previously reported on the same configuration. Comparison of windward symmetry plane data with predictions based upon an approximate engineering method was found to yield reasonable agreement for angles of attack from 20 to 40 deg. The leeward surface pressure data were observed to be roughly an order of magnitude lower than the corresponding windward data. At low angles of attack, regions of high pressure were noted on the windward wing surface. The result is attributed to vortical action or shock impingement. High pressures were also measured on the deflected body flap, a critical region for this type of vehicle. Reynolds number effects were found to be insignificant.

Wurster, K. E.↗

Development of UV Optical Measurements of Nitric Oxide and Hydroxyl Radical at the Exit of High Pressure Gas Turbine Combustors

Measurements of nitric oxide (NO) and hydroxyl radical (OR) have been made in a laboratory flat flame at pressures up to 30 atm using line-of-sight resonant absorption. Data are reported at equivalence ratios of 0.98 and 1.3 and pressures of 1, 5, 10, 20 and 30 atm. The performance of the in-situ LTV absorption technique with assessed at these elevated pressures by comparing the measured absorption with those predicted by detailed theoretical spectroscopic models for NO and OH. Previous to this experiment the resonant models had not been verified at pressures greater than two atmospheres. Agreement within 25% was found between the measurements and predictions with only slight modification of the existing models for both NO and OH to account for line center shifting and pressure broadening. Continuum interference of hot oxygen (O2) on the NO absorption spectra was not significant in the interpretation of the data. The optical methods used in this study are distinct from laser-based diagnostics such as laser induced fluorescence and, hence, have the potential to provide independent verification of the laser-based measurements. The methodology is also of sufficient simplicity to be hardened into a portable optical measurement system that can be deployed in gas turbine engine test cells. A miniature fiber optic couple portable instrument is described.

Liscinsky, D. S.↗

Turbine Airfoil With CMC Leading-Edge Concept Tested Under Simulated Gas Turbine Conditions

Silicon-based ceramics have been proposed as component materials for gas turbine engine hot-sections. When the Navy s Harrier fighter experienced engine (Pegasus F402) failure because of leading-edge durability problems on the second-stage high-pressure turbine vane, the Office of Naval Research came to the NASA Glenn Research Center at Lewis Field for test support in evaluating a concept for eliminating the vane-edge degradation. The High Pressure Burner Rig (HPBR) was selected for testing since it could provide temperature, pressure, velocity, and combustion gas compositions that closely simulate the engine environment. The study focused on equipping the stationary metal airfoil (Pegasus F402) with a ceramic matrix composite (CMC) leading-edge insert and evaluating the feasibility and benefits of such a configuration. The test exposed the component, with and without the CMC insert, to the harsh engine environment in an unloaded condition, with cooling to provide temperature relief to the metal blade underneath. The insert was made using an AlliedSignal Composites, Inc., enhanced HiNicalon (Nippon Carbon Co. LTD., Yokohama, Japan) fiber-reinforced silicon carbide composite (SiC/SiC CMC) material fabricated via chemical vapor infiltration. This insert was 45-mils thick and occupied a recessed area in the leading edge and shroud of the vane. It was designed to be free floating with an end cap design. The HPBR tests provided a comparative evaluation of the temperature response and leading-edge durability and included cycling the airfoils between simulated idle, lift, and cruise flight conditions. In addition, the airfoils were aircooled, uniquely instrumented, and exposed to the exact set of internal and external conditions, which included gas temperatures in excess of 1370 C (2500 F). In addition to documenting the temperature response of the metal vane for comparison with the CMC, a demonstration of improved leading-edge durability was a primary goal. First, the metal vane was tested for a total of 150 cycles. Both the leading edge and trailing edge of the blade exhibited fatigue cracking and burn-through similar to the failures experienced in service by the F402 engine. Next, an airfoil, fitted with the ceramic leading edge insert, was exposed for 200 cycles. The temperature response of those HPBR cycles indicated a reduced internal metal temperature, by as much as 600 F at the midspan location for the same surface temperature (2100 F). After testing, the composite insert appeared intact, with no signs of failure on either the vane s leading or trailing edge. Only a slight oxide scale, as would be expected, was noted on the insert. Overall, the CMC insert performed similarly to a thick thermal barrier coating. With a small air gap between the metal and the SiC/SiC leading edge, heat transfer from the CMC to the metal alloy was low, effectively lowering the temperatures. The insert's performance has proven that an uncooled CMC can be engineered and designed to withstand the thermal up-shock experienced during the severe lift conditions in the Pegasus engine. The design of the leading-edge insert, which minimized thermal stresses in the SiC/SiC CMC, showed that the CMC/metal assembly can be engineered to be a functioning component.

Robinson, R. Craig↗

26th Space Simulation Conference Proceedings. Environmental Testing: The Path Forward

Topics covered include: A Multifunctional Space Environment Simulation Facility for Accelerated Spacecraft Materials Testing; Exposure of Spacecraft Surface Coatings in a Simulated GEO Radiation Environment; Gravity-Offloading System for Large-Displacement Ground Testing of Spacecraft Mechanisms; Microscopic Shutters Controlled by cRIO in Sounding Rocket; Application of a Physics-Based Stabilization Criterion to Flight System Thermal Testing; Upgrade of a Thermal Vacuum Chamber for 20 Kelvin Operations; A New Approach to Improve the Uniformity of Solar Simulator; A Perfect Space Simulation Storm; A Planetary Environmental Simulator/Test Facility; Collimation Mirror Segment Refurbishment inside ESA s Large Space; Space Simulation of the CBERS 3 and 4 Satellite Thermal Model in the New Brazilian 6x8m Thermal Vacuum Chamber; The Certification of Environmental Chambers for Testing Flight Hardware; Space Systems Environmental Test Facility Database (SSETFD), Website Development Status; Wallops Flight Facility: Current and Future Test Capabilities for Suborbital and Orbital Projects; Force Limited Vibration Testing of JWST NIRSpec Instrument Using Strain Gages; Investigation of Acoustic Field Uniformity in Direct Field Acoustic Testing; Recent Developments in Direct Field Acoustic Testing; Assembly, Integration and Test Centre in Malaysia: Integration between Building Construction Works and Equipment Installation; Complex Ground Support Equipment for Satellite Thermal Vacuum Test; Effect of Charging Electron Exposure on 1064nm Transmission through Bare Sapphire Optics and SiO2 over HfO2 AR-Coated Sapphire Optics; Environmental Testing Activities and Capabilities for Turkish Space Industry; Integrated Circuit Reliability Simulation in Space Environments; Micrometeoroid Impacts and Optical Scatter in Space Environment; Overcoming Unintended Consequences of Ambient Pressure Thermal Cycling Environmental Tests; Performance and Functionality Improvements to Next Generation Thermal Vacuum Control System; Robotic Lunar Lander Development Project: Three-Dimensional Dynamic Stability Testing and Analysis; Thermal Physical Properties of Thermal Coatings for Spacecraft in Wide Range of Environmental Conditions: Experimental and Theoretical Study; Molecular Contamination Generated in Thermal Vacuum Chambers; Preventing Cross Contamination of Hardware in Thermal Vacuum Chambers; Towards Validation of Particulate Transport Code; Updated Trends in Materials' Outgassing Technology; Electrical Power and Data Acquisition Setup for the CBER 3 and 4 Satellite TBT; Method of Obtaining High Resolution Intrinsic Wire Boom Damping Parameters for Multi-Body Dynamics Simulations; and Thermal Vacuum Testing with Scalable Software Developed In-House.

Packard, Edward A.↗

An alternative method of changing the pulse duration in a stretcher-compressor pair by changing the gas pressure in the compressor

The relatively narrow bandwidth of neodymium glass requires a much larger stretch ratio of chirped-pulse amplification (CPA) systems. This factor, together with a large incident angle on the gratings, makes glass CPA systems extremely sensitive to the refractive index of the medium in the stretcher-compressor. High sensitivity of the stretcher-compressor pair for hybrid optical parametric chirped-pulse amplification and an Nd:glass laser to the refractive index was demonstrated in air, vacuum, and carbon dioxide, and a pulse duration close to the transform limit was reached. An alternative way to change the pulse duration was proposed. The pulse duration from the best compression of 500 fs to 30 ps was smoothly varied by changing the air pressure from 10 -6 Torr to 1 atm in the compressor and up to 52 ps in carbon dioxide, while the stretcher and compressor remained untouched. Finally, excellent agreement of the measured pulse duration with theoretical calculations was demonstrated.

47 OTHER INSTRUMENTATION↗