Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Development of In-Situ Chlorine Generator for Metal Purification (End of Contract Report)

It has been demonstrated that rare-earth and actinide metals can be purified via conversion to chlorides and heating to volatilize impurities. To this end, BYU has been working towards designing, building, and testing a system that incorporates the chlorine gas generation method into the chloride volatility process. The efforts made towards the project tasks listed in the Statement of Work are addressed in the following sections. Finally, a report on information related to this project that has been published or presented is addressed. By the end of the contract period, small-scale tests using LaCl 3 -CaCl 2 to generate Cl 2 had been conducted, the produced Cl 2 was successfully reacted with Ce foil to create CeCl 3 , initial designs for the large-scale apparatus were completed, and manufacturing for the large-scale apparatus had begun.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Heat Transfer in a Trapped-Vortex Combustor Designed for High-Temperature Material Testing

Next generation gas turbines will reduce carbon emissions by improving their cycle efficiencies and implementing hydrogen as a low-carbon fuel. The combined-cycle efficiency can be improved by increasing the combustor outlet temperature and decreasing the cooling air required for hot-section parts. Ultra-high temperature ceramic matrix composites (CMC) can survive increasingly extreme environments due to their strong mechanical properties at expected conditions. The introduction of CMCs in high-hydrogen flame environments requires testing at realistic conditions that mimic the thermochemical and fluid mechanic states in gas-turbine combustors. In this work, we describe a new experiment that has been designed to test high-temperature materials in a combustor-relevant environment. Its trapped-vortex combustor chamber design allows for high levels of fuel flexibility and wide flame stability limits. Testing of monolithic silicon carbide (SiC) samples in this environment was done to characterize the heat transfer to material samples over a wide range of operating conditions, including variations in fuel composition and thermal power. Heat flux measurements were verified in non-reacting and reacting environments after which they were benchmarked with previous literature to verify the operation of the facility with heated air. Testing in combustor-relevant conditions shows high levels of heat flux to the material samples in the combustor, particularly downstream of the anchored flame.

Richins, Porter [Pennsylvania State University , ,↗

Combined Structural Analysis of Core and Image Log of TGH 76-31 South East of Mt Baker, Washington State

Despite active volcanism, few geothermal energy resources have been developed in the Cascades Range. Temperature Gradient Hole 76-31 was drilled to ~440 m measured depth to probe for zones where fractures provide fluid conduits that transport deep volcanic heat to shallow depths that could support baseload, carbon neutral electrical generation. These zones were predicted by a Play Fairway assessment (PFA) of resource potential along a zone 11 km west-southwest of the summit of Mount Baker Volcano. Rock core, temperature logs, and an acoustic image log were obtained. By comparison to outcrops, the core has been initially interpreted as the Chilliwack group comprised of partially metamorphosed basaltic to andesitic volcanics. Core mapping reveals complex, steeply dipping networks of fractures and brecciation along slickensided strike slip faults; clay alteration is common in many of these structures. The majority of fractures are thoroughly healed by layers of chlorite and calcite; preservation of pyrite indicates anoxic conditions. The majority of fracture porosity resides in very dense fractures a few centimeters or less in length. The image log provides good insights into attitude of fractures that fully transect the core, but generally underestimates fracture density. The combination of complex, non-planar fracture zones containing many short fractures and healing promote misinterpretation of natural fracture attitude and density in the image log. The healing and anoxic minerals are consistent with the conductive temperature gradient measured in the well below a shallow isothermal zone, although, several fractures are open or only partially healed and resulted in fluid entries into the well. Here, the equilibrated measured temperature gradient of 64ºC/km and calculated heat flow of 145 mW/m2 is more than twice the regional average, indicating local influence of the Mt Baker magmatic system at the Little Park Creek TGH site.

Cascades↗

The Effect of Hydrothermal Alteration and Microcracks on Hydraulic Properties and Poroelastic Deformation: A Case Study of the Blue Mountain Geothermal Field

Abstract Geothermal energy plays a vital role in decarbonizing electricity and heat supply. Effective utilization of geothermal resources hinges on identifying or generating permeable reservoir zones and understanding how effective pressure variations affect fluid circulation and reservoir properties by poroelastic deformation. Hydrothermal alteration can modify the petrophysical properties of geothermal reservoir rocks, which may increase or decrease its productivity. Understanding these alteration effects is essential to predict and optimize long‐term sustainable geothermal operations. Here, we investigate the impact of hydrothermal alteration on poroelastic and hydraulic properties of diverse lithologies in a series of deformation tests performed at several confining (0–80 MPa) and pore pressure (10–30 MPa) levels. Experimental results of hydrothermally altered dikes and phyllites obtained from the Blue Mountain geothermal field (Nevada, USA) are compared to thermally cracked La Peyratte granite (France) and correlated with petrophysical properties, mineral composition, and microstructures. Argillic alteration of dikes increases porosity and storage capacity but lowers thermal conductivity and increases pore compressibility. Conversely, silicate precipitation in phyllites increases stiffness and thermal conductivity but also reduces porosity and permeability. Experimentally determined effective pressure coefficients range from 0.1 to 0.9, differ for permeability and volumetric strain and decrease with increasing effective pressure. The presence of compliant microcracks and crack‐like pores significantly increases the stress sensitivity of La Peyratte granite and silicified phyllites. This study demonstrates how thermal and chemical alteration impacts poromechanical and petrophysical characteristics of geothermal targets, which ultimately govern reservoir stability and subsidence, induced seismicity as well as fluid and heat extraction efficiency during geothermal operations.

Schuster, Valerian [Helmholtz Centre Potsdam GFZ G↗

Method for dynamic control of light emission from phosphors with heat excitations

An optically emissive material and, in particular, materials for use in single photon generation technologies, have multiple excited energy states that have different decay rates and can emit photons with different properties. A primary excitation radiation source is configured to apply primary radiation to an optically emissive material to excite the optically emissive material into a primary excited state. A secondary excitation radiation source is configured to apply secondary radiation to a thermal contribution material to generate thermal energy in the thermal contribution material. The thermal contribution material is physically configured to transfer thermal energy to the optically emissive material and excite the optically emissive material from the primary excited state to a secondary excited state for dynamic control of the emission rate, or emitted photon properties, of the optically emissive material.

36 MATERIALS SCIENCE↗

Magnetic mesh generation and field line reconstruction for scrape-off layer and divertor modeling in stellarators

The design of divertor targets and baffles for optimal heat and particle exhaust from magnetically confined fusion plasmas requires a combination of fast, low-fidelity models (such as EMC3-Lite (Feng 2022 Plasma Phys. Control. Fusion 64 125012)) for scoping studies and high-fidelity ones (such as EMC3-EIRENE (Feng et al 2014 Contrib. Plasma Phys. 54 426–31)) for verification. Both of those approaches benefit from a magnetic flux tube mesh for fast interpolation and mapping of field line segments (Feng et al 2005 Phys. Plasmas 12 052505). A new automated mesh generator for unstructured quadrilateral flux tubes with adaptive refinement is presented and integrated into FLARE (Frerichs 2024 Nucl. Fusion 64 106034). For HSX with an extended first wall, it is found that several layers of flux tubes can span the entire half field period before splitting is required. This is an advantage over the traditional setup of the EMC3-EIRENE mesh where careful construction of several sub- domains is required already for the much tighter present first wall. In particular, there is no longer the need to manually construct a suitable outer boundary for the mesh. The divide and conquer paradigm with unstructured mesh layout offers a powerful alternative for fast head load approximation that is suitable for integration into optimization workflows. Further examples for W7-X and CTH demonstrate the versatile application range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A model to assess Zircaloy’s mechanical property changes following a transient beyond critical heat flux

Maintaining the integrity of nuclear fuel rods is essential for ensuring public health and safety in nuclear power generation. During reactor operation, this integrity is confirmed by demonstrating compliance with established regulatory acceptance criteria. For moderate-frequency events, such as limiting transients and anticipated operational occurrences (AOOs), the current fuel integrity criterion is based on preventing boiling transition. This criterion assumes that prevention of boiling transition will prevent excessive cladding heating and, thus, fuel failure during normal operations. While conservative, this approach places significant constraints on core design, fuel cycle economics, and a plant’s ability to perform major power uprates, leading to suboptimal fuel utilization and inefficient carbon-free energy production. A more efficient approach could be achieved by revising the failure criterion to a material-specific limit rather than strictly preventing the boiling transition, since boiling transition per se is not a cause of fuel cladding failure. Here, as a result, a new licensing framework based on material properties, termed time-at-temperature (t@T), is needed. This approach would allow for brief periods of post–critical heat flux operation during an AOO without compromising safety. Implementing the t@T licensing strategy requires a robust technical foundation in material properties, which must be established through comprehensive data collection on both unirradiated and irradiated fuel and cladding materials. This foundation would enable the development of a safety basis that ensures safe operation while providing greater flexibility and efficiency for reactor operation. This paper documents a thorough review of the available data to establish a baseline knowledge that can inform the development of cladding mechanical models, as well as identify experimental data gaps that need to be addressed in future research. Machine learning and data informatics were utilized to extract the importance of parameters on the t@T parameter. Industry tools were used to perform baseline analyses to define the relevant transient conditions for data analysis. The subsequent review successfully identified applicable experimental data, as well as sufficient data to evaluate changes in cladding mechanical properties following an AOO transient. Rather than developing new models, this work coupled existing irradiation annealing and recrystallization models to calculate changes in hardness, yield stress, and ultimate tensile stress following an AOO event. The findings from this review were summarized to highlight the experimental data needs required to fill remaining gaps and support the development of future t@T licensing methodologies.

Cladding performance↗

Creation and characterization of warm dense matter isochorically heated by an intense laser-driven proton beam to temperatures exceeding 100 eV

The warm dense matter (WDM) is an exotic state of matter encountered in inertial confinement implosions for fusion energy, as well as the interiors of giant planets like Jupiter, brown dwarfs, the atmospheres of white dwarfs, neutron star crusts, and newly discovered exo-planets. One efficient way to create WDM is to use protons accelerated by a high-intensity short-pulse laser to isochorically heat dense samples to WDM states. Despite its importance, direct temperature measurements within WDM targets are scarce. This study utilizes an intense proton beam generated by the kilojoule EP laser further focused and guided by a curved foil and cone structure to efficiently heat a thin copper sample. A high-resolution streaked spectrometer tuned to copper K α fluorescence lines provided bulk temperature measurements every ~2 ps, revealing temperatures exceeding 100 eV in under 50 ps. Particle-in-cell simulations of proton transport and energy deposition closely matched the observed heating dynamics, including transverse temperature gradients revealed by the broadening of K α lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermomagnetic generators for ultra-low-grade marine thermal energy harvesting

Low-grade thermal gradients in marine environments represent an underexploited energy source for autonomous sensing and monitoring. Converting such small temperature differences into usable electrical power remains a key challenge for ocean-deployed systems. We present a deployable thermomagnetic generator thoroughly characterized for marine-relevant energy harvesting. The device powers an internet-connected sensor and harvests ultra-low temperature differences akin to those at the ocean surface. It draws heat from water and rejects it to ambient air, operating optimally at a temperature difference (ΔT) of ~7.5 °C. Laboratory prototypes generated up to 6.7 mW at ΔT ~ 10 °C with gentle airflow (~1 m s -1 ). A separate controlled wave-tank demonstration validated stable operation and sensor powering under marine-like boundary conditions. Given its voltage and power margins, the generator could sustain multiple sensor nodes. Scalability and material assessments identify modular deployment and non-rare-earth alternatives as pathways toward practical marine energy harvesting and low-grade waste-heat recovery.

16 TIDAL AND WAVE POWER↗

Ultrasonic Measurements of Temperature Profile and Heat Fluxes in Coal-Fired Power Plants (Final Report)

Many industrial processes are inaccessible or inhospitable to characterization by traditional temperature measurement methods, such as thermocouples, especially over prolonged exposure to harsh environments. Ultrasound is an established characterization technology with diverse applications ranging from medical imaging to therapies to flaw detection to nondestructive evaluation. Ultrasound may characterize solid materials and components noninvasively as a nondestructive evaluation modality and obtain internal measurements of material properties. For example, the speed of ultrasound propagation changes with Young’s modulus and Poisson’s ratio, which can be found from its measurements. Traditional ultrasonic characterization assumes all material properties remain constant with the position. When this assumption holds, a property of interest may be measured by relating it to the speed of ultrasound propagation (or a speed of sound, SOS) and measuring the SOS by timing the ultrasound propagation through a known distance. However, when a property of interest is spatially distributed, the propagation time depends on the SOS changing with the position along the ultrasound propagation path. The multiple temperature distributions may lead to an identical time of flight (TOF). Temperature is one property that impacts the speed of ultrasound and often cannot be assumed to remain constant with the position. Previously, in the context of temperature, we addressed the challenge of ultrasonic characterization of spatially distributed properties by developing a method for measuring segmental temperature distributions (MSTD). This method divides the ultrasonic propagation into segments bound by echogenic features. These features provide ultrasonic interfaces where some energy is reflected toward the receiving transducer, and the rest continues through the medium. The time-of-flight between the echoes reflected from echogenic features characterizes the spatial distribution in the properties of interest in the corresponding segment of the ultrasonic propagation path. This project demonstrated the application of the MSTD method in industrial conditions of the coal-fired power plant. We implemented the MSTD using metals and alloys waveguides, which may be the existing structure for which the temperature distribution is characterized or purposefully designed waveguides added to the structure by welding or other means specifically to quantify thermal properties using the MSTD method. Previous iterations of the MSTD method used ceramic and cementitious waveguides, which significantly attenuate ultrasound. On the other hand, low attenuation in metallic waveguides creates interactions between echogenic features which compilates the signal analysis in the segmental TOF measurements. We have established the WG design principles that minimize the interferences between trailing and primary echoes and, in some cases, eliminate them. The waveguides in which echoes do not interfere improve the timing accuracy and the robustness of ultrasonic measurements of the spatial distributions in material properties. Our emphasis remained on the estimation of the temperature distributions. We have developed general recommendations for designing ultrasonically segmented waveguides with the reduced influence of trailing echoes. Two of our waveguide designs were tested in the industry. The first waveguide was designed for insertion into a combustion zone of the utility-scale coal-fired power plant boiler. The second design allows the characterization of temperature distribution in the direction normal to the boiler’s water wall, a large heat exchanger converting the chemical energy released during combustion to the steam driving the electrical power generation turbines. These waveguides were designed to operate within a restrictive space of thermally insulated water wall and incorporate densely located echogenic features while combatting the influence of trailing echoes. The project has successfully demonstrated the feasibility of using the developed method for accurate, continuous, and robust temperature measurements in extreme environments of power generation and other industrial processes. It, therefore, has achieved its overarching goal of advancing the technology readiness level of the novel Ultrasound Measurements of Segmental Temperature Distribution (US-MSTD) method for real-time measurements of the temperature distribution and heat fluxes closer to commercial availability, developing a prototype multipoint measurement system, and validating its performance on coal-fired utility boilers. The success of this project was achieved in collaboration with the power generator, Rocky Mountain Power, and set the stage for the transfer of this technology from the laboratory to the industry.

01 COAL, LIGNITE, AND PEAT↗

Impact of fusion reactor neutronics modeling for transmutation and thermal feedback *

Abstract Fusion neutronics calculations provide important metrics pertinent to fusion device operations, such as tritium breeding ratios (TBRs) and data on heat deposition, material activation, and damage. Because of the high computational burden required to generate a high-fidelity Monte Carlo simulation of a 3D fusion device, various assumptions are made to reduce computational time by simplifying the reactor model or the calculation iteration. This paper explores the impact of fusion neutronics metrics such as the TBR and decay heat of structural materials based on assumptions of material composition in the fusion reactor and temperature modeling of materials. Results show that for compact tokamaks with high power and long operational cycles, the transmutation of structural materials is significant enough to cause a substantial change in the flux spectrum and decrease the TBR by 1.68% after 2 years of full power operation. Additionally, assuming a constant temperature and material density can impact the TBR calculations up to 3%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Neural network model of neutral beam injection in the EAST tokamak to enable fast transport simulations

The neutral beam injection (NBI) system in EAST produces energetic neutral particles, which collide with electrons and ions in tokamak plasmas and heat the plasmas through Coulomb collisions. Moreover, it drives a non-inductive source of current, due to the charge-exchange collision between neutral particles and ions, and injects toroidal torque, which generates a toroidal rotation of the plasma. The effect caused by the NBI system, such as plasma heating, current drive, total neutron rate, momentum transfer, and shine-through, are modeled by a comprehensive module called NUBEAM. However, NUBEAM is computationally intensive since it relies on Monte Carlo methods. In this work, a neural network model has been developed as a surrogate model for NUBEAM in EAST. The database for neural-network model training, validation and testing is generated by running TRANSP for experimental discharges from recent EAST campaigns (after the latest NBI upgrade) while using the NUBEAM module. Simulation results illustrate that the trained neural network has the capability of replicating the predictions made by NUBEAM while demanding a significantly shorter execution time. Finally, these results indicate that surrogate models like the one proposed in this work could enable fast transport simulations for EAST after integrating them into a control-oriented predictive code such as COTSIM.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of BISON to UO 2 MiniFuel fission gas release analysis

There has been a recent push to accelerate fuel qualification by developing revolutionary capabilities to reduce irradiation periods, and thereby, reduce the time required to qualify a new fuel system. One such capability is the MiniFuel irradiation capsule designed to miniaturize fuel samples and irradiate “mini” fuel samples under isothermal temperature conditions. MiniFuel allows steady-state irradiations to decouple the traditionally coupled fission rate (i.e., power) and temperature parameters to understand and generate microstructures observed in fuel operated in a commercial reactor. Furthermore, this process offers the possibility to gather in situ data as well as postirradiation or transient data such as thermal conductivity, specific heat, fission gas diffusion and release, etc. However, accelerating fuel qualification is not solely reliant on generating large amounts of data but also on developing an informed test matrix designed to rapidly generate impactful data. Additionally, this process is reliant on fuel performance codes, such as BISON, to evaluate MiniFuel irradiations using existing material models. This process pinpoints model/data gaps, identifies desired irradiation conditions, and subsequently supports model validation and development. This work describes the use of BISON to perform a number of sensitivity studies designed to understand conditions that lead to fission gas release (FGR) under steady-state isothermal irradiation conditions and temperature transient conditions. The model is applied to a UO 2 MiniFuel example and shows an overall good qualitative agreement with experimental FGR annealing tests under different temperature conditions. It also accounts well for microstructural effects on FGR. When quantitatively compared with FGR data from previously irradiated 103 MWd/kgU UO 2 discs under thermal annealing, the model shows a less satisfactory agreement with the experimental data. Finally, a UO 2 MiniFuel test matrix is proposed to help to extend the model's operational range and validate the new FGR model capabilities to higher burnups and transient conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improvements to the Modeling of the TREAT Reactor and Experiments

This paper summarizes the latest improvements and lessons learned from the modeling and simulation of the transient test reactor at Idaho National Laboratory using the MAM- MOTH reactor physics application. MAMMOTH is a MOOSE-based, Finite Element Method application that specializes in the analysis of the spatial dynamics behavior of nuclear reactors. Since early 2018 several transient tests have been conducted at TREAT, thus providing the opportunity to apply and benchmark modern modeling and simulation tools. MAMMOTH was used to provide predictions of the power coupling factor between the core and the experiment for various experiments. Even though the power coupling factor predictions agree very well with the experimental data, within the bounds of the experimental uncertainty, one shortcoming was the underprediction of the total energy deposited in the core and in the experiment. Determination of the sources for this discrepancy are ongoing, but several key problems have been identified and resolved, thus providing valuable insights for future research. This paper discusses several of these lessons learned. First, the heat capacity data for the TREAT fuel has some significant problems due to limitations of the measurement techniques used circa 1960s. The sensitivity of the peak power and the total energy deposition to various representations of the heat capacity is approximately 5%. Second, the effects of the biological shield and thermal column on the modeling of the core are non-negligible, since they affect the mean generation time and the effective reflection of neutrons back into the core, which is suspected to be important during the core heat up. Matching the reactor period resolves the fact that the reduced spatial domain used in the MAMMOTH model underpredicts the mean generation time. The neutron reflection from these regions is marginally improved with the use of an albedo boundary condition. Third, modeling of the control rod movement with a multi-scheme method is introduced and its current limitations are exposed. Fourth, we explore the effects of using a homogenized model with Superhomogenization equivalence and how that differs from fully heterogeneous simulations. Finally, the energy condensation effects for this graphite core are significant. Solutions with 10 and 26 energy groups show the benefits of using a finer coarse group structure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FINAL TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE APPLICATION OF A HEAT INTEGRATED POST-COMBUSTION CO2 CAPTURE SYSTEM WITH HITACHI ADVANCED SOLVENT INTO EXISTING COAL-FIRED POWER PLANT

This report contains the results of a techno-economic assessment (TEA) conducted of a heat integrated post-combustion CO2 capture process with Hitachi advanced solvent for retrofit into an existing coal-fired power plant (but treated as greenfield plant on cost analysis). The process has been developed by the University of Kentucky Center for Applied Energy (UK CAER). EPRI was chiefly responsible for this analysis, with significant input from WorleyParsons, Hitachi Power Systems America (Hitachi) and UK CAER. The project also involves the design, fabrication, installation, testing, and analyses of a slipstream facility located at L&GE-KU’s E.W. Brown Generating Station to demonstrate the UK CAER carbon capture system that could utilize heat integration with the main power plant. The design, start-up, and baseline of the pilot system was performed with a generic 30 wt% MEA solvent to obtain data for direct comparison with the DOE/NETL Reference Case followed by testing Hitachi’s proprietary solvent H3-1. In this techno-economic analysis, two cases utilizing the UK CAER process are compared, using different approach temperatures and solvent, against the DOE/NETL Reference Case (Case 10). The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as CO2 partial pressure increase at the flue gas inlet, thermal integration of the process, and performance of the Hitachi H3-1 solvent. Recent UK CAER process pilot-scale testing data and process simualtion data showed that the packing heights of absorber and stripper columns were significantly oversized in the prelimanary TEA (Task 2 of this project) and thus updated in this final TEA for the H3-1 case only. In addition, the solvent make-up cost for H3-1 was updated based on lattest test results. Finally, a heat integration with the main power plant was applied in this final TEA to increase overall energy effciency for both the MEA and H3-1 cases. Additonal reductions in capital and operational costs are expected but not taken into account here. Shorter columns result in reduced pressure drops, smaller blower head and pump hydraulic head requirements. An increase in overall energy efficiency resuls in a decreased size of the power plant, the CCS and a reduced parasitic steam requirement to the CCS. The net efficiency of the UK CAER integrated PC power plant with CO2 capture changes from 26.2% for the Reference Case 10 plant in 2010 revised DOE/NETL baseline report to 27.6% for the MEA options considered, and 29.1% for the options utilizing the Hitachi advanced solvent. The UK CAER Process + Hitachi case also produces an extra 30.9 MW of generation compared to the UK CAER Process + MEA case and total 60.9 MW more than DOE Case 10. LCOE ($/MWh) values are $172.08/MWh for the MEA option and $157.65/MWh for the Hitachi H3-1 solvent cases considered in comparison to $189.59/MWh in January 2012 dollar for the Reference Case 10. The UK CAER CCS process with MEA case lowers energy consumption for CO2 capture to 1340 Btu/lb-CO2 captured as compared to 1540 Btu/lb-CO2 in the Reference Case 10. The UK CAER CCS process with H3-1 case further lowers energy consumption for CO2 capture to 973 Btu/lb-CO2 captured, for an advantage of 36.8% less energy consumption than Case 10. The study also shows 38.1% less heat rejection associated with the carbon capture system from 3398 MBtu/hr (Case 10) to 2104 MBtu/hr for the UK CAER + MEA system. Heat rejection is reduced to 2464 MBtu/hr in the UK CAER + H3-1 case, for a 27.5 % decrease compared to Case 10. Modeling outputs show that in the UK CAER process, the cooling water that is 2-5°C cooler than conventional cooling tower water can be achieved for ambient conditions common to the midwest and other regions. The results from the techno-economic assessment show that the proposed technology can be investigated further as a viable alternative to conventional CO2 capture technology. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variables being the approach temperature and CO2 partial pressure increase at the flue gas inlet. A summary of the key advantages of the UK CAER Process + H3-1 case for LCOE and other economic factors compared to the DOE Case 10 is as follows: • A lower variable operating cost by $1.56/MWh ($1.08MWh less than the UK CAER Process + MEA Case), a 11.7% reduction compared to the DOE Case 10 • A lower COE by $25.32MWh ($13.94/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower LCOE by $31.94/MWh ($17.51/MWh lower than the UK CAER Process + MEA Case), a 16.9% reduction compared to the DOE Case 10 • A lower cost of CO2 captured by $18.65/tonne CO2 ($9.44/tonne CO2 lower than the UK CAER Process + MEA Case), a 30.4% reduction compared to the DOE Case 10 • A lower cost of CO2 avoided by $34.95/tonne CO2 ($18.53 tonne CO2 lower than the UK CAER Process + MEA Case), a 38.7% reduction compared to the DOE Case 10

Bhown, Abhoyjit S.↗

Resolving Discrepancies in Spin-Torque Ferromagnetic Resonance Measurements: Lineshape versus Linewidth Analyses

When spin-orbit torques are measured using spin-torque ferromagnetic resonance, two alternative ways of analyzing the results to extract the torque efficiencies—lineshape analysis and analysis of the change in linewidth versus direct current—often give inconsistent results. We identify a source for these inconsistencies. We show that fits of spin-torque ferromagnetic resonance data to the standard analysis framework leave significant residuals that we identify as due to (i) current-induced excitations of a small volume of magnetic material with magnetic damping much larger than that of the bulk of the magnetic layer, which we speculate is associated with the heavy-metal–magnet interface and (ii) oscillations of the sample magnetization at the modulation frequency due to heating. Here, the dependence of the residual signals on direct current can interfere with an accurate extraction of spin-torque efficiencies by the linewidth method. We show that the discrepancies between the two types of analysis can be largely eliminated by extrapolation of the window of magnetic fields used in the linewidth fits to small values so as to minimize the influence of the residual signals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗