Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Advances in Multi-Physics Modeling for Parallel Finite Element Code Suite ACE3P

SLAC developed ACE3P code suite is a comprehensive set of parallel finite-element codes for multi-physics modeling of particle accelerators. Running on massively parallel computer platforms for high fidelity and high accuracy simulation, ACE3P enables rapid virtual prototyping of accelerator and RF component design, optimization and analysis. Furthermore, recent advances of ACE3P have been focused on the implementation of advanced numerical algorithms, enhancement of multi-physics capabilities, and improvement of code performance on state-of-the-art high performance computing (HPC) platforms for large-scale RF modeling in accelerator applications and beyond. In this paper, we will present a nonlinear electromagnetic (EM) eigensolver for damping calculation of resonant modes for cavities coupled with waveguides, the thermal solver for accurate evaluation of heat loads in superconducting RF (SRF) cavity power coupler, the elastic solver for investigation of SRF cavity cryomodule (CM) bowing due to thermal effect, the frequency domain mechanical solver for studying SRF cavity mechanical oscillation modes, the particle tracking code for dark current simulation in SRF CM using a hybrid MPI+OpenMP parallel programing model, the time domain solver for high fidelity modeling of EM wave propagation for medical device in human body.

97 MATHEMATICS AND COMPUTING↗

Charge Collection and Propagation in Diamond X-Ray Detectors

Diamond is a unique material for x-ray energy conversion. Its high thermal conductivity and low coefficient of thermal expansion make it ideal for high heat load environments. However, its large bandgap, while offering insensitivity to visible light, makes charge trapping more likely (thermal detrapping less likely) than in silicon; energy conversion efficiency is also 3-4 times less even under the best conditions. High material strength and x-ray transmission also are potentially useful features for certain applications in x-ray science. Limitations to charge collection efficiency such as recombination and charge trapping have been investigated quantitatively using quasi-continuous tunable synchrotron radiation under flexible biasing schemes as well using detailed Monte Carlo Simulations. In the case of charge collection efficiency, the magnitude of the applied field, initial particle energy, and probe depth are adjusted. The diffusion and drift of photo-generated charge clouds are explicitly considered for the specific energy loss behavior of diamond. While recombination loss at the entrance window of diamond diodes is qualitatively similar to a treatment for an additional 'dead' carbon window layer, the observed field and photon energy dependence implies that the more sophisticated model is more correct quantitatively. In addition, charge propagation in diamond is unique in that photoconductive gain is possible. Effectively, charge trapping of one carrier leads to screening of the applied field. In order to avoid photoconductive gain, either blocking contacts or explicit detrapping is required. Quantitative analysis of photoconductive gain as a function of applied field, x-ray power, waveform and photon energy offers insight into the fundamental limitations of state of the art single crystal diamond. Simple models are proposed to assist in extrapolating the observed behavior towards useful detector devices.

43 PARTICLE ACCELERATORS↗

Conceptual Designs of Dipole Magnet for Muon Collider Storage Ring

Conceptual designs of a superconducting dipole magnet for a storage ring of a muon collider with a 1.5 TeV center of mass (c.o.m.) energy and an average luminosity of 10 34 cm -2 s -1 are presented. In contrast to proton machines, the dipoles for the muon collider should be able to handle ~0.5 kW/m of dynamic heat load from the muon beam decays. The magnets are based on Nb 3 Sn superconductor and designed to provide an operating field of 10 T in the 20-mm aperture with the critical current margin required for reliable machine operation. The magnet cross-sections were optimized to achieve the best possible field quality in the aperture occupied by beams. The developed mechanical structures provide adequate coil prestress and support at the maximum level of Lorentz forces in the coil. Magnet parameters are reported and compared with the requirements.

43 PARTICLE ACCELERATORS↗

JLAB's Super High Momentum Spectrometer's Superconducting Q1 Magnet

Abstract- The commissioning and test results of a super ferric, superconducting, quadrupole magnet, constructed by Scientific Magnetics Inc. for Thomas Jefferson National Accelerator Facility (TJNAF also known as JLAB) will be presented. The quadrupole magnet, named Q1, is the first focusing element in the Super High Momentum Spectrometer (SHMS). The SHMS, located within JLAB's experimental Hall C, consists of all superconducting magnets in a dQQQD configuration and is part of the JLAB's 12 Gev upgrade. Here "d" refers to the small horizontal bend dipole, "Q" stands for focusing quadrupole magnets and "D" is the vertical bending, momentum-selecting dipole magnet. Characterization of the magnet's cryogenic heat loads and magnetic field quality will be presented along with descriptions of the magnet's control system, power supply, and quench detection system.

Superconductor Magnets, Detector Magnets, Cold Iro↗

Thermodynamic Analyses of the LCLS-II Cryogenic Distribution System

The Linac Coherent Light Source (LCLS) at Stanford Linear Accelerator Center (SLAC) is in the process of being upgraded to a superconducting radio frequency (SRF) accelerator and renamed LCLS-II. This upgrade requires thirty-five 1.3 GHz SRF cryomodules (CM) and two 3.9 GHz CM. A cryogenic distribution system (CDS) is in development by Fermi National Accelerator Laboratory to interconnect the CM Linac with the cryogenic plant (CP). The CDS design utilizes cryogenic helium to support the CM operations with a high temperature thermal shield around 55 K, a low temperature thermal intercepts around 5 K, and a SRF cavity liquid helium supply and sub-atmospheric vapor return both around 2 K. Additionally the design must accommodate a Linac consisting of two parallel cryogenic strings, supported by two independent CP utilizing CDS components such as distribution boxes, transfer lines, feed caps and endcaps. In this paper, we describe the overall layout of the cryogenic distribution system and the major thermodynamic factors which influence the CDS design including heat loads, pressure drops, temperature profiles, and pressure relieving requirements. In addition the paper describes how the models are created to perform the analyses.

43 PARTICLE ACCELERATORS↗

YBCO-on-Kapton: Material for High-Density Quan-tum Computer Interconnects with Ultra-Low Thermal Conductance

Development of practical quantum computers would require 1000's of qubits and equally large number of read-outs, bias and drive lines. New materials that combine low passive loss and good RF properties are needed. In this study we report performance of signal interconnects comprised of high-temperature YBCO films that are exfoliated from a metal substrate and transferred to a E-Kapton tape. The technology offers low-loss transition be-tween 60 K to sub-mK environments and interfacing with off-shelf flexible silicon electronics. We demonstrate < 1 dB/m at-tenuation at 6 GHz at 77 K. The microstrip assemblies demon-strated no degradation upon multiple cycles to liquid Nitrogen and conduction cooling down to 18 K. We discuss designs of a practical high-density signal cable with passive heat load well below 1 μW per line. The YBCO-on-Kapton technology offers a practical pathway to large error-corrected quantum computing systems.

47 OTHER INSTRUMENTATION↗

Cooling Design and Thermal Analysis for Thermal Shields of a Cryocooler-Cooled Superconducting ECR Ion Source MARS-D Magnet

Here, a demonstrative NbTi based Mixed Axial and Radial field System (MARS-D) is being developed for a next-Generation Electron Cyclotron Resonance Ion Source (ECRIS) at Lawrence Berkeley National Laboratory (LBL), which employs a novel closed-loop coil design scheme that more efficiently utilizes conductor fields and extend the application of NbTi for high frequency (up to 45 GHz) ECR operation. The NbTi MARS-D magnet consists of a single hexagonally shaped closed-loop coil and a set of auxiliary solenoids. A cryostat for cooling the MARS-D magnet is under design at LBL. The MARS-D magnet working around 4.2 K will be bath-cooled in liquid helium using multiple two-stage cryocoolers. An intermediate temperature thermal radiation shield is adopted to reduce the heat leakage imposed on 4.2 K coil cold mass from room temperature. The thermal shield is conduction-cooled by the first-stage cold heads of four two-stage cryocoolers and the cold head of a single-stage cryocooler shared with nine binary leads. The temperature in the area of the shield that warm ends of HTS leads are mounted on is expected no higher than 60 K, which is limited by maximum allowable working temperature of HTS leads. The paper presents thermal analysis on the thermal radiation shield including heat loads and effects of eddy current induced during quench on its material selection.

ECRIS↗

Testing of a 15 kA Superconducting Transformer

Here, the manufacturing of superconducting magnets for High Energy Physics (HEP) and Fusion Energy Sciences (FES) applications requires high-current conductors to generate stronger magnetic fields without increasing the inductance of the magnet. Increased inductance is undesirable due to the associated AC losses, which reduce the temperature margin; and the quench protection also becomes complicated. Testing high-current conductors with a direct current (DC) room temperature power supply is unfeasible for two primary reasons: 1) the limited capacity to supply large currents, and 2) the significant heat load losses at the current leads. A superconducting transformer offers a solution to both challenges. A 50-kA superconducting transformer is planned for manufacturing and commissioning at Brookhaven National Laboratory as part of its user facility upgrade. This transformer will facilitate the testing of superconducting cables, conductors, joints, and insert coils under high magnetic field conditions (10 T) and with currents up to 50-kA. To evaluate the manufacturing process and validate the theoretical models, the magnet division has developed and tested a 15-kA prototype transformer. A control loop has been implemented to ensure precise current delivery to the sample. This paper presents the coil design, manufacturing, and experimental results from the cold tests.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charge Collection and Propagation in Diamond X-ray Detectors

Diamond is a unique material for x-ray energy conversion. Its high thermal conductivity and low coefficient of thermal expansion make it ideal for high heat load environments. High material strength and x-ray transmission also are potentially useful features for certain applications in x-ray science. However, its large bandgap, while offering insensitivity to visible light, makes charge trapping more likely (thermal detrapping less likely) than in silicon; energy conversion efficiency is also 3-4 times less even under the best conditions. Limitations to charge collection efficiency such as recombination and charge trapping have been investigated quantitatively using quasi-continuous tunable synchrotron radiation under flexible biasing schemes as well using detailed Monte Carlo simulations. In the case of charge collection efficiency, the magnitude of the applied field, initial particle energy, and probe depth are adjusted. The diffusion and drift of photo-generated charge clouds are explicitly considered for the specific scattering behavior of diamond. While recombination loss at the entrance window of diamond diodes is qualitatively similar to a treatment for an additional 'dead' carbon window layer, the observed field and photon energy dependence implies that the more sophisticated model is more correct quantitatively. In addition, charge propagation in diamond is unique in that photoconductive gain is possible. Effectively, charge trapping of one carrier leads to screening of the applied field. In order to avoid photoconductive gain, either blocking contacts or explicit detrapping is required. Initial investigations of photoconductive gain as a function of applied field, waveform and photon energy have provided insight into the performance of state of the art single crystal diamond. Simple models are proposed to assist in extrapolating the observed behavior towards useful detector devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Test of Wendelstein 7-X Water-Cooled Divertor Scraper

Heat load calculations have indicated the possible overloading of the ends of the water-cooled divertor facing the pumping gap beyond their technological limit. The intention of the scraper is the interception of some of the plasma fluxes both upstream and downstream before they reach the divertor surface. The scraper is divided into six modules of four plasma facing components (PFCs); each module has four PFCs hydraulically connected in series by two water boxes (inlet and outlet). A full-scale prototype of one module has been manufactured. Development activities have been carried out to connect the water boxes to the cooling pipes of the PFCs by tungsten inert gas internal orbital welding. This prototype was successfully tested in the GLADIS facility with 17 MW/m2 for 500 cycles. The results of these activities have confirmed the possible technological basis for a fabrication of the water-cooled scraper.

Boscary, J.↗

Pre- and post-launch operation of the Resolve soft X-ray spectrometer onboard the XRISM satellite

Resolve is a high-resolution X-ray spectrometer onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), launched on September 6 (UT), 2023. The Resolve has performed better than its required spectral resolution (7 eV at full width at half maximum at 6 keV), both on the ground and in orbit, and has been confirmed to have comparable performance to the soft X-ray spectrometer onboard the ASTRO-H (Hitomi) satellite. The focal plane is composed of an array of microcalorimeter detectors operated at 50 mK to achieve the required energy resolution, and the cooling system is designed to satisfy the lifetime requirement of over 3 years. The focal plane and cooling system are contained in a vacuum-insulated dewar. The cooling system is equipped with a two-stage adiabatic demagnetization refrigerator (ADR) that uses superfluid liquid helium (LHe) as its heat sink. The system includes a third ADR stage that can be used to provide the heat sink when the helium is exhausted. A Joule–Thomson cooler and several two-stage Stirling coolers are used to reduce the heat load on the LHe. During pre-launch operations, we carried out a superfluid LHe top-off operation. The resultant amount of LHe onboard Resolve was over 35 L before launch, which is sufficient to meet the lifetime requirement. During post-launch operation, the LHe vent valve was opened 5 min after launch during rocket acceleration, and the cryocoolers were turned on after several orbits, as planned, which established stable cooling within the dewar. Pre- and post-launch operations for the Resolve instrument were planned around multiple constraints from launch vehicle operations; all were successfully completed, and the launch requirements were fully met.

X-Ray Imaging and Spectroscopy Mission↗

A theoretical comparison of x-ray angiographic image quality using energy-dependent and conventional subtraction methods

Purpose: X-ray digital subtraction angiography (DSA) is widely used for vascular imaging. However, the need to subtract a mask image can result in motion artifacts and compromised image quality. The current interest in energy-resolving photon-counting (EPC) detectors offers the promise of eliminating motion artifacts and other advanced applications using a single exposure. The authors describe a method of assessing the iodine signal-to-noise ratio (SNR) that may be achieved with energy-resolved angiography (ERA) to enable a direct comparison with other approaches including DSA and dual-energy angiography for the same patient exposure. Methods: A linearized noise-propagation approach, combined with linear expressions of dual-energy and energy-resolved imaging, is used to describe the iodine SNR. The results were validated by a Monte Carlo calculation for all three approaches and compared visually for dual-energy and DSA imaging using a simple angiographic phantom with a CsI-based flat-panel detector. Results: The linearized SNR calculations show excellent agreement with Monte Carlo results. While dual-energy methods require an increased tube heat load of 2x to 4x compared to DSA, and photon-counting detectors are not yet ready for angiographic imaging, the available iodine SNR for both methods as tested is within 10% of that of conventional DSA for the same patient exposure over a wide range of patient thicknesses and iodine concentrations. Conclusions: While the energy-based methods are not necessarily optimized and further improvements are likely, the linearized noise-propagation analysis provides the theoretical framework of a level playing field for optimization studies and comparison with conventional DSA. It is concluded that both dual-energy and photon-counting approaches have the potential to provide similar angiographic image quality to DSA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High resolution stationary digital breast tomosynthesis using distributed carbon nanotube x-ray source array

Purpose: The purpose of this study is to investigate the feasibility of increasing the system spatial resolution and scanning speed of Hologic Selenia Dimensions digital breast tomosynthesis (DBT) scanner by replacing the rotating mammography x-ray tube with a specially designed carbon nanotube (CNT) x-ray source array, which generates all the projection images needed for tomosynthesis reconstruction by electronically activating individual x-ray sources without any mechanical motion. The stationary digital breast tomosynthesis (s-DBT) design aims to (i) increase the system spatial resolution by eliminating image blurring due to x-ray tube motion and (ii) reduce the scanning time. Low spatial resolution and long scanning time are the two main technical limitations of current DBT technology. Methods: A CNT x-ray source array was designed and evaluated against a set of targeted system performance parameters. Simulations were performed to determine the maximum anode heat load at the desired focal spot size and to design the electron focusing optics. Field emission current from CNT cathode was measured for an extended period of time to determine the stable life time of CNT cathode for an expected clinical operation scenario. The source array was manufactured, tested, and integrated with a Selenia scanner. An electronic control unit was developed to interface the source array with the detection system and to scan and regulate x-ray beams. The performance of the s-DBT system was evaluated using physical phantoms. Results: The spatially distributed CNT x-ray source array comprised 31 individually addressable x-ray sources covering a 30 angular span with 1 pitch and an isotropic focal spot size of 0.6 mm at full width at half-maximum. Stable operation at 28 kV(peak) anode voltage and 38 mA tube current was demonstrated with extended lifetime and good source-to-source consistency. For the standard imaging protocol of 15 views over 14, 100 mAs dose, and 2 x 2 detector binning, the projection resolution along the scanning direction increased from 4.0 cycles/mm [at 10% modulation-transfer-function (MTF)] in DBT to 5.1 cycles/mm in s-DBT at magnification factor of 1.08. The improvement is more pronounced for faster scanning speeds, wider angular coverage, and smaller detector pixel sizes. The scanning speed depends on the detector, the number of views, and the imaging dose. With 240 ms detector readout time, the s-DBT system scanning time is 6.3 s for a 15-view, 100 mAs scan regardless of the angular coverage. The scanning speed can be reduced to less than 4 s when detectors become faster. Initial phantom studies showed good quality reconstructed images. Conclusions: A prototype s-DBT scanner has been developed and evaluated by retrofitting the Selenia rotating gantry DBT scanner with a spatially distributed CNT x-ray source array. Preliminary results show that it improves system spatial resolution substantially by eliminating image blur due to x-ray focal spot motion. The scanner speed of s-DBT system is independent of angular coverage and can be increased with faster detector without image degration. The accelerated lifetime measurement demonstrated the long term stability of CNT x-ray source array with typical clinical operation lifetime over 3 years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-93: Activation of Psoralen at Depth Using Kilovoltage X-Rays: Physics Considerations in Implementing a New Teletherapy Paradigm

Purpose: Psoralen is a UV-light activated anti-cancer biotherapeutic used for treating skin lesions (PUVA) and advanced cutaneous T-cell lymphoma (ECP). To date psoralen has not been used to treat deep seated tumors due to difficulty in generating UV-light at depth. We recently demonstrated psoralen activation at depth by introducing energy converting particles that absorb kV x-ray radiation and re-emit UV-light. Our in-vitro work found that 0.2–1Gy using 40–100kVp x-rays combined with psoralen and particles can induce a substantial apoptotic response beyond that expected from the sum of individual components. In preparation for a phase I clinical trial of canine companion animals, we address the physics and dosimetry considerations for applying this new teletherapy paradigm to an in-vivo setting. Methods: The kV on-board imaging (OBI) system mounted on a medical linear accelerator (Varian) was commissioned to deliver the prescribed dose (0.6Gy) using 80 and 100kVp. Dosimetric measurements included kVp, HVL, depth dose, backscatter factors, collimator and phantom scatter factors, field size factors, and blade leakage. Absolute dosimetry was performed following AAPM TG61 recommendations and verified with an independent kV dose meter. We also investigated collimated rotational delivery to minimize skin dose using simple dose calculations on homogeneous cylindrical phantoms. Results: Single beam delivery is feasible for shallow targets (<5cm) without exceeding skin tolerance, while a rotational delivery may be utilized for deeper targets; skin dose is ∼75% of target dose for 80kVp collimated rotational delivery to a 3cm target within a 20cm phantom. Heat loading was tolerable; 0.6Gy to 5cm can be delivered before the anode reaches 75% capacity. Conclusion: KV teletherapy for Psoralen activation in deep seated tissue was successfully commissioned for a Varian OBI machine for use in a phase I clinical trial in canines. Future work will use Monte Carlo dosimetry to investigate dose in presence of bone. Research funded by Immunolight LLC. H. Walder, Z. Fathi, & W. Beyer are employees of Immunolight LLC which holds a patent on the technology. Drs. Adamson and Oldham are consultants to Immunolight LLC.

60 APPLIED LIFE SCIENCES↗

Divertor Plasma Detachment Control Neural Network

DivControlNN is a state-of-the-art software tool that leverages advanced machine learning techniques to predict and control divertor plasma behavior in fusion reactors. Plasma, a highly energetic and electrically charged gas, requires meticulous management to protect reactor components and maintain optimal energy production. Conventional simulation methods, although extremely detailed, typically demand extensive computational time-making them unsuitable for real-time control scenarios. DivControlNN addresses this challenge by learning from tens of thousands of high-fidelity simulations, thereby creating a rapid surrogate model that can deliver near-instantaneous predictions. At the core of its functionality is a sophisticated technique known as latent space mapping, which condenses complex, high-dimensional plasma data into a compact, lower-dimensional representation. This streamlined representation enables the system to quickly forecast essential plasma properties and determine the precise conditions required for effective detachment. Detachment is a crucial process in which the plasma is cooled before reaching the divertor plates, thereby reducing heat loads and mitigating material erosion. In recent experiments conducted on the KSTAR tokamak in South Korea, DivControlNN successfully guided the detachment process without any fine-tuning-even when applied to a new tungsten divertor configuration. By achieving a computational speed-up of over one hundred million times compared to traditional simulation methods while maintaining low prediction errors, DivControlNN stands to significantly enhance real-time control and diagnostic capabilities in future fusion reactors. This breakthrough paves the way for safer, more reliable reactor operation and represents a major advancement toward realizing fusion energy as a practical, sustainable, and clean power source.

Xu, Xueqiao [Lawrence Livermore National Laborator↗

Dynamic Facade Dashboard v0.1.0

The dashboard is a useful tool for early-stage building design decision-making and communication, as it can help users quickly compare the energy and non-energy related performance of various automated, integrated facade systems using a library of pre-computed data. Users can explore the impacts of various design choices by selecting different facade glazing and shading systems, facade control strategies, and lighting control strategies across multiple climate zones. The dashboard instantly visualizes key metrics, including energy usage in HVAC and lighting, peak cooling and heating load, and daylight availability, allowing immediate trade-off analysis to optimize building efficiency and comfort.

Yu, Tammie [Lawrence Berkeley National Laboratory ↗

Overview of innovative PMI research on NSTX-U and associated PMI facilities at PPPL

Developing a reactor compatible divertor and managing the associated plasma material interaction (PMI) has been identified as a high priority research area for magnetic confinement fusion. Accordingly on NSTX-U, the PMI research has received a strong emphasis. Moreover, with ˜15 MW of auxiliary heating power, NSTX-U will be able to test the PMI physics with the peak divertor plasma facing component (PFC) heat loads of up to 40-60 MW/m 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray spectrometer based on a bent diamond crystal for high repetition rate free-electron laser applications

A precise spectral characterization of every single pulse is required in many x-ray free-electron laser (XFEL) experiments due to the fluctuating spectral content of self-amplified spontaneous emission (SASE) beams. Bent single-crystal spectrometers can provide sufficient spectral resolution to resolve the SASE spikes while also covering the full SASE bandwidth. To better withstand the high heat load induced by the 4.5 MHz repetition rate of pulses at the forthcoming European XFEL facility, a spectrometer based on single-crystal diamond has been developed. Here, we report a direct comparison of the diamond spectrometer with its Si counterpart in experiments performed at the Linac Coherent Light Source.

43 PARTICLE ACCELERATORS↗