Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HOMOGENEITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Dose homogeneity specification for reference dosimetry of nonstandard fields

Purpose: To investigate the sensitivity of the plan-class specific correction factor to dose distributions in composite nonstandard field dosimetry. Methods: A cylindrical water-filled PMMA phantom was constructed at the center of which reference absorbed dose could be measured. Ten different TomoTherapy-based IMRT fields were created on the CT images of the phantom. The dose distribution for each IMRT field was estimated at the position of a radiation detector or ionization chamber. The dose in each IMRT field normalized to that in a reference 10 x 10 cm{sup 2} field was measured using a PTW micro liquid ion chamber. Based on the new dosimetry formalism, a plan-class specific correction factor k{sub Q{sub p{sub c{sub s{sub r,Q}{sup f{sub p}{sub c}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}}} for each field was measured for two Farmer-type chambers, Exradin A12 and NE2571, as well as for a smaller Exradin A1SL chamber. The dependence of the measured correction factor on parameters characterizing dose distribution was analyzed. Results: Uncertainty on the plan-class specific correction factor measurement was in the range of 0.3%-0.5% and 0.3%-0.8% for the Farmer-type chambers and the Exradin A1SL, respectively. When the heterogeneity of the central region of the target volume was less than 5%, the correction factor did not differ from unity by more than 0.7% for the three air-filled ionization chambers. For more heterogeneous dose deliveries, the correction factor differed from unity by up to 2.4% for the Farmer-type chambers. For the Exradin A1SL, the correction factor was closer to unity due to the reduced effect of dose gradients, while it was highly variable in different IMRT fields because of a more significant impact of positioning uncertainties on the response of this chamber. Conclusions: The authors have shown that a plan-class specific correction factor can be specified as a function of plan evaluation parameters especially for Farmer-type chambers. This work provides a recipe based on quantifying dose distribution to accurately select air-filled ionization chamber correction factors for nonstandard fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A simplified technique for delivering total body irradiation (TBI) with improved dose homogeneity

Purpose: Total body irradiation (TBI) with megavoltage photon beams has been accepted as an important component of management for a number of hematologic malignancies, generally as part of bone marrow conditioning regimens. The purpose of this paper is to present and discuss the authors' TBI technique, which both simplifies the treatment process and improves the treatment quality. Methods: An AP/PA TBI treatment technique to produce uniform dose distributions using sequential collimator reductions during each fraction was implemented, and a sample calculation worksheet is presented. Using this methodology, the dosimetric characteristics of both 6 and 18 MV photon beams, including lung dose under cerrobend blocks was investigated. A method of estimating midplane lung doses based on measured entrance and exit doses was proposed, and the estimated results were compared with measurements. Results: Whole body midplane dose uniformity of {+-}10% was achieved with no more than two collimator-based beam modulations. The proposed model predicted midplane lung doses 5% to 10% higher than the measured doses for 6 and 18 MV beams. The estimated total midplane doses were within {+-}5% of the prescribed midplane dose on average except for the lungs where the doses were 6% to 10% lower than the prescribed dose on average. Conclusions: The proposed TBI technique can achieve dose uniformity within {+-}10%. This technique is easy to implement and does not require complicated dosimetry and/or compensators.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dose response of selected ion chambers in applied homogeneous transverse and longitudinal magnetic fields

Purpose: The magnetic fields of an integrated MR-Linac system will alter the paths of electrons that produce ions in the ionization chambers. The dose response of selected ion chambers is evaluated in the presence of varying transverse and longitudinal magnetic fields. The investigation is useful in calibration of therapeutic x-ray beams associated with MR-Linac systems. Methods: The Monte Carlo code PENELOPE was used to model the irradiation of NE2571, and PR06C ionization chambers in the presence of a transverse and longitudinal (with respect to the photon beam) magnetic fields of varying magnitude. The long axis of each chamber was simulated both parallel and perpendicular to the incident photon beam for each magnetic field case. The dose deposited in each chamber for each case was compared to the case with zero magnetic field by means of a ratio. The PR06C chamber's response was measured in the presence of a transverse magnetic field with field strengths ranging from 0.0 to 0.2 T to compare to simulated results. Results: The simulations and measured data show that in the presence of a transverse magnetic field there is a considerable dose response (maximum of 11% near 1.0 T in the ion chambers investigated, which depends on the magnitude of magnetic field, and relative orientation of the magnetic field, radiation beam, and ion chamber. Measurements made with the PR06C chamber verify these results in the region of measurement. In contrast, a longitudinal magnetic field produces only a slight increase in dose response (2% at 1.5 T) that rises slowly with increasing magnetic field and is seemingly independent of chamber orientation. Response trends were similar for the two ion chambers and relative orientations considered, but slight variations are present from chamber to chamber. Conclusions: Care must be taken when making ion chamber measurements in a transverse magnetic field. Ion chamber responses vary not only with transverse field strength, but with chamber orientation and type, and can be considerable. Longitudinal magnetic fields influence ion chamber responses relatively little (2% at 1.5 T), and only at field strengths in excess of 1.0 T.

60 APPLIED LIFE SCIENCES↗

SU-E-J-51: Dose Response of Common Solid State Detectors in Homogeneous Transverse and Longitudinal Magnetic Fields

Purpose: Solid state radiation detectors are often used for dose profiles and percent depth dose measurements. The dose response of selected solid state detectors is evaluated in varying transverse and longitudinal magnetic fields for eventual use in MR-Linac devices. Methods: A PTW 60003 and IBA PFD detector were modeled in the Monte Carlo code PENELOPE, incorporating a magnetic field which was varied in strength and oriented both transversely and longitudinally with respect to the incident photon beam. The detectors' long axis was in turn oriented either parallel or perpendicular to the photon beam. Dose to the active volume of each detector was scored, and its ratio to dose with zero magnetic field strength (dose response) was determined. Accuracy of the simulations was evaluated by measurements using both chambers taken at low field with a small electromagnet. Simulations were also performed in a water phantom to compare to the in air results. Results: Significant dose response was found in transverse field geometries, nearing 20% at 1.5T. The response is highly dependent on relative orientations to the magnetic field and photon beam, and on detector composition. Low field measurements confirm these results. In the presence of longitudinal magnetic fields, the detectors exhibit little dose response, reaching 0.5–1% at 1.5T regardless of detector orientation. Water tank simulations compared well to the in air simulations when not at the beam periphery, where in transverse magnetic fields only, the water tank simulations differed from the in air results. Conclusion: Transverse magnetic fields can cause large deviations in dose response, and are highly position orientation dependent. Comparatively, longitudinal magnetic fields exhibit little to no dose response in each detector as a function of magnetic field strength. Water tank simulations show longitudinal fields are generally easier to work with, but each detector must be evaluated separately.

07 ISOTOPE AND RADIATION SOURCES↗

Dose response of selected solid state detectors in applied homogeneous transverse and longitudinal magnetic fields

Purpose: MR-Linac devices under development worldwide will require standard calibration, commissioning, and quality assurance. Solid state radiation detectors are often used for dose profiles and percent depth dose measurements. The dose response of selected solid state detectors is therefore evaluated in varying transverse and longitudinal magnetic fields for this purpose. Methods: The Monte Carlo code PENELOPE was used to model irradiation of a PTW 60003 diamond detector and IBA PFD diode detector in the presence of a magnetic field. The field itself was varied in strength, and oriented both transversely and longitudinally with respect to the incident photon beam. The long axis of the detectors was oriented either parallel or perpendicular to the photon beam. The dose to the active volume of each detector in air was scored, and its ratio to dose with zero magnetic field strength was determined as the “dose response” in magnetic field. Measurements at low fields for both detectors in transverse magnetic fields were taken to evaluate the accuracy of the simulations. Additional simulations were performed in a water phantom to obtain few representative points for beam profile and percent depth dose measurements. Results: Simulations show significant dose response as a function of magnetic field in transverse field geometries. This response can be near 20% at 1.5 T, and it is highly dependent on the detectors’ relative orientation to the magnetic field, the energy of the photon beam, and detector composition. Measurements at low transverse magnetic fields verify the simulations for both detectors in their relative orientations to radiation beam. Longitudinal magnetic fields, in contrast, show little dose response, rising slowly with magnetic field, and reaching 0.5%–1% at 1.5 T regardless of detector orientation. Water tank and in air simulation results were the same within simulation uncertainty where lateral electronic equilibrium is present and expectedly differed at the beam edge in transverse field orientations only. Due to the difference in design, the two detectors behaved differently. Conclusions: When transverse magnetic fields are present, great care must be taken when using diamond or diode detectors. Dose response varies with relative detector orientation, magnetic field strength, and between detectors. This response can be considerable (∼20% for both detectors). Both detectors in longitudinal fields exhibit little to no dose response as a function of magnetic field. Water tank simulations seem to suggest that the diode detector is better suited to general beam commissioning, and each detector must be investigated separately.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-J-139: Amplitude of Low Frequency Fluctuation(ALFF) and Regional Homogeneity (ReHo) Study of the Respiration Motion Control Byhypnosis

Purpose: Respiration control by hypnosis is a method in reducing the detriment to the healthy organs or organizations for patients during radiotherapy, especially for lung and abdomen cancer (Fig.1). It’s hypothesized that there exists alterations neurological brain activity during the hypnosis state of respiratory motion control in comparison with resting state. Methods: Thirteen healthy volunteers were organized to participate in a hypnosis experiment that consisted of two sectional scans of functional magnetic resonance imaging (fMRI), rest state condition (RSC) scanning and hypnosis state condition (HSC) scanning. In addition, the coronal section of the lung was scanned during both conditions. During the hypnosis scan, the volunteers were under the hypnotists’ guidance to keep peace and stable respiration. To evaluate the altered physiological performance of hypnosis in the respiratory control, three conventional indicators ALFF/fALFF (0.01–0.08Hz) and ReHo, were applied to identify the difference. Results: Compared with RSC, HSC showed significant (p<0.05) higher ReHo in superior temporal gyrus, middle temporal gyrus, frontal lobe, middle occipital gyrus, parietal lobe, cerebellum anterior Lobe and lingual gyrus, and left brainstem (Fig.2). While significant lower ReHo in middle frontal gyrus, superior frontal gyrus, inferior semi-lunar lobule, sub-lobar and limbic lobe (Fig.2). As for the ALFF results, significant higher value of HSC was observed in superior temporal gyrus, middle temporal gyrus, middle occipital gyrus, middle occipital gyrus, cerebellum anterior lobe, lingual gyrus, sub-lobar, limbic lobe, and lower in cerebellum posterior lobe, inferior semi-lunar lobule, inferior parietal lobule right middle frontal gyrus, cerebellar tonsil (Fig.3). The results of fALFF were similar to ALFF (Fig.4). The above results demonstrated that most significant regions of brain were uniform between ReHo and ALFF/fALFF. Conclusion: Hypnosis is a new psychological and helpful technology for respiration control. This study provides new insights of neurological brain activity during hypnosis of respiration control. This work is supported by grants from Guangdong Innovative Research Team Program of China (Grant No. 2011S013), National 863 Programs of China (Grant Nos. 2012AA02A604 and 2015AA043203), the National High-tech R&D Program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917)

60 APPLIED LIFE SCIENCES↗

Coulomb acceleration of light ions from homogeneous and layered targets

As applied to the problem of laser-induced ion acceleration, we have developed a theory for the expansion of a completely ionized thin two-ion-species target in the regime of a Coulomb explosion typical of the interaction of relativistically intense femtosecond laser pulses with nanofoils. Based on this theory and a simple numerical model, we have studied the generation of bunches of quasi-monoenergetic light ions and found their characteristics as a function of target parameters. We have performed a comparative analysis of the acceleration of light ions uniformly distributed in the target and concentrated in the form of a thin layer. For the production of high-quality accelerated ion beams, we have found optimal conditions that were qualitatively confirmed by our three-dimensional kinetic simulations of the laser pulse-thin target interaction.

43 PARTICLE ACCELERATORS↗

Kinetics and energy states of nanoclusters in the initial stage of homogeneous condensation at high supersaturation degrees

The condensation of metal vapor in an inert gas is studied by the molecular dynamics method. Two condensation regimes are investigated: with maintenance of partial pressure of the metal vapor and with a fixed number of metal atoms in the system. The main focus is the study of the cluster energy distribution over the degrees of freedom and mechanisms of the establishment of thermal equilibrium. It is shown that the internal temperature of a cluster considerably exceeds the buffer gas temperature and the thermal balance is established for a time considerably exceeding the nucleation time. It is found that, when the metal vapor concentration exceeds 0.1 of the argon concentration, the growth of clusters with the highest possible internal energy occurs, the condensation rate being determined only by the rate of heat removal from clusters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the calculation of thermodynamic quantities in the Holstein model for homogeneous polynucleotides

The dynamics of a system for different types of polarons, i.e., in polythymine nucleotides (large-radius polaron), in polyadenine fragments (small-radius polaron), and in polyguanine DNA (intermediate case) at different thermostat temperatures are calculated using the semi-classical Holstein model. The temperature dependences of the thermodynamic equilibrium values of the total energy, the energy of an excess charge, and the electronic heat capacity have been obtained. For all polaron types, the peak of the electronic heat capacity dependence on temperature separates two modes (polaron and delocalized state). The electronic part of the energy is estimated in the high-temperature limit. In all cases, the electron heat capacity at high temperatures decreases in inverse proportion to the square of the temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Plasmon excitations in homogeneous neutron-star matter

We study the possible collective plasma modes which can affect neutron-star thermodynamics and different elementary processes in the baryonic density range between nuclear saturation {rho}{sub 0} and 3{rho}{sub 0}. In this region, the expected constituents of neutron-star matter are mainly neutrons, protons, electrons, and muons (npe{mu} matter), under the constraint of beta equilibrium. The elementary plasma excitations of the pe{mu} three-fluid medium are studied in the RPA framework. We emphasize the relevance of the Coulomb interaction among the three species, in particular, the interplay of the electron and muon screening in suppressing the possible proton plasma mode, which is converted into a sound-like mode. The Coulomb interaction alone is able to produce a variety of excitation branches and the full spectral function shows a rich structure at different energy. The genuine plasmon mode is pushed at high energy and it contains mainly an electron component with a substantial muon component, which increases with density. The plasmon is undamped for not too large momentum and is expected to be hardly affected by the nuclear interaction. All the other branches, which fall below the plasmon, are damped or over-damped.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser acceleration of light ions from a thin homogeneous foil of complex atomic composition

A model of the acceleration of light impurity particles from a plane ultrathin foil of complex ion composition by a high-power ultrashort high-contrast laser pulse is proposed. A study is made of both purely Coulomb ion acceleration, typical of extremely high electron energies, and ion acceleration under the conditions of space charge separation, determined by the finite typical electron temperature. Exact and approximate analytic approaches to describing impurity particle acceleration are developed. The spatial and spectral parameters of accelerated light particles are obtained, and their dynamics is investigated as a function of their relative charge density in a model of test impurity particles and in a model in which their own electrostatic field is taken into account. Optimum conditions for the generation of quasi-monoenergetic ions are discussed, depending on the laser radiation parameters and target composition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of the homogeneity of the current distribution in a dielectric barrier discharge in air by means of a segmented electrode

The current distribution in a dielectric barrier discharge in atmospheric-pressure air at a natural humidity of 40–60% was studied experimentally with a time resolution of 200 ps. The experimental results are interpreted by means of numerically simulating the discharge electric circuit. The obtained results indicate that the discharge operating in the volumetric mode develops simultaneously over the entire transverse cross section of the discharge gap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of Bi isovalent dopants on the formation of homogeneous coherently strained InAs quantum dots in GaAs matrices

The distribution of hydrostatic strains in Bi{sup 3+}-doped InAs quantum dots embedded in a GaAs matrix are calculated in the context of the deformation-potential model. The dependences of strains in the material of spherical InAs quantum dots with substitutional (Bi {yields} As) and interstitial (Bi) impurities on the quantum-dot size are derived. The qualitative correlation of the model with the experiment is discussed. The data on the effect of doping on the morphology of self-assembled InAs:Bi quantum dots in a GaAs matrix are obtained.

36 MATERIALS SCIENCE↗

Investigation of the Far-IR Reflection Spectra of SmS Single Crystals and Polycrystals in the Homogeneity Range

The far- and mid-IR reflection spectra of Sm{sub 1+} {sub x}S (x = 0–0.17) samples are recorded and analyzed, as well as their electrical and structural parameters at a temperature of T = 300 K. The bond ionicity in SmS is shown to fall with a decrease in the area of the X-ray coherent scattering region and an increase in the concentration of donor impurities and, consequently, conduction electron concentration. The electrical conductivity of stoichiometric SmS single crystals and polycrystals can be determined with an error of 10% from the IR reflection spectra. Due to the low structural quality of the samples, the electrical conductivity cannot be determined in the case of deviation from stoichiometry.

36 MATERIALS SCIENCE↗

Ferroelectrics of homogeneously deformed rare-earth garnet crystals, excited by elastic wave propagation

The effect of deformation on the electric properties in rare-earth garnet compounds is elucidated. It is shown that inhomogeneous deformation causes the emergence of electric polarization in garnet crystals on account of nonequivalent low-symmetry sites of rare-earth ions in the cubic structure of these crystals, whose symmetry of the environment has no inversion center. The polarization of a rare-earth ion subsystem in garnet crystals is studied upon the elastic wave propagation therein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonlinearity of Volt–Ampere Characteristics of Homogeneous Compensated Detector GaAs Structures

The results of a study of carrier transfer and recharging of deep levels in semiconductor structures for ionizing radiation detectors are presented. Resistive-type arsenide–gallium structures with Schottky barriers and uniform distribution of deep chromium acceptors and donor EL2 centers have been studied. Solving the continuity and Poisson equations using the commercial design package, the effect of the volume depletion of detector structures by electrons with an increase in the applied voltage has been observed. It is established that the nonlinearity of the volt-ampere characteristics of structures occurs due to a change in the type of conductivity upon transition from an equilibrium to a nonequilibrium state. In this case, structures with initial (equilibrium) hole-type conductivity have close to linear volt–ampere characteristics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗