Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Focused Ultrasound Surgery Control Using Local Harmonic Motion: VX2 Tumor Study

The objective of this study was to develop a real-time method for controlling focused ultrasound surgery using ultrasound imaging. The approach uses measurements of localized harmonic motion (LHM) in order to perform controlled FUS exposures by detecting changes in the elastic properties of tissues during coagulation. Methods: Nine New Zealand rabbits with VX2 tumors implanted in the thigh were used for this study. LHM was generated within the tumors by periodic induction of radiation force using a FUS transducer (80-mm focal length, 100-mm diameter, 20-mm central hole, 1.485-MHz). Tissue motion was tracked by collecting and cross-correlating RF signals during the motion using a separate diagnostic transducer (3-kHz PRF, 5-MHz). After locating the tumor in MR images, a series of sonications were performed to treat the tumors using a reduction in LHM amplitude to control the exposure. Results: LHM was successfully used to control the sonications. A LHM amplitude threshold value was determined at which changes were considered significant and then the exposure was started and stopped when the LHM amplitude dropped below the threshold. The appearance of a lesion was then verified by MRI. The feasibility of LHM measurements to control FUS exposure was validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation and coarsening of Ga droplets on focused-ion-beam irradiated GaAs surfaces

We have investigated the formation and coarsening of Ga droplets on focused-ion-beam (FIB) irradiated GaAs surfaces. To separately examine formation and coarsening, Ga droplets were fabricated by Ga{sup +} FIB irradiation of GaAs substrates with and without pre-patterned holes. We determined the droplet growth rate and size distribution as a function of FIB energy following irradiation. The data suggest a droplet formation mechanism that involves Ga precipitation from a Ga-rich layer, followed by droplet coarsening via a combination of diffusion and Ostwald ripening or coalescence via droplet migration (dynamic coalescence)

36 MATERIALS SCIENCE↗

Design and characterization of supersonic nozzles for wide focus laser-plasma interactions

In this work we optimize the contour of supersonic nozzles to produce long and stable gas jets suitable to be used in loose focus laser-plasma applications. The nozzle design method takes into account the inclusion of a boundary layer that increases the length of the usable gas jet. Two 8 mm supersonic nozzles were characterized, one with a Mach number of 3 and another with a Mach number of 6, using a Mach-Zehnder interferometer performed with a He:Ne 4 cm expanded laser beam. The experimental results confirm that the inclusion of the boundary layer produces an 8 mm constant longitudinal density profile for the nozzle with a Mach number of 6 (NM6) and a 4.5 mm constant longitudinal density profile for the nozzle with a Mach number of 3 (NM3).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct fabrication of nanopores in a metal foil using focused ion beam with in situ measurements of the penetrating ion beam current

A through hole with a diameter less than 100 nm was fabricated in an Ag foil using only a focused ion beam (FIB) system and in situ measurements of the penetrating ion beam. During the drilling of the foil by a FIB of Ga{sup +} ions, the transmitted part of the beam was measured with an electrode mounted on the back face of the foil. When the beam current penetrating through the nanopore reached a certain value, irradiation was stopped and the area of the created aperture was measured with a scanning electron microscope. The resulting area was correlated with the current of the penetrating ion beam. This suggests that we can fabricate a nanopore of the desired size by controlling the ion beam via penetrating ion beam measurements. The smallest aperture thus created was circular with diameter of 30 nm.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Periodic magnetic field as a polarized and focusing thermal neutron spectrometer and monochromator

A novel periodic magnetic field (PMF) optic is shown to act as a prism, lens, and polarizer for neutrons and particles with a magnetic dipole moment. The PMF has a two-dimensional field in the axial direction of neutron propagation. The PMF alternating magnetic field polarity provides strong gradients that cause separation of neutrons by wavelength axially and by spin state transversely. The spin-up neutrons exit the PMF with their magnetic spins aligned parallel to the PMF magnetic field, and are deflected upward and line focus at a fixed vertical height, proportional to the PMF period, at a downstream focal distance that increases with neutron energy. The PMF has no attenuation by absorption or scatter, as with material prisms or crystal monochromators. Embodiments of the PMF include neutron spectrometer or monochromator, and applications include neutron small angle scattering, crystallography, residual stress analysis, cross section measurements, and reflectometry. Presented are theory, experimental results, computer simulation, applications of the PMF, and comparison of its performance to Stern-Gerlach gradient devices and compound material and magnetic refractive prisms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ten-year Biochemical Disease-free Survival After High-intensity Focused Ultrasound (HIFU) for Localized Prostate Cancer: Comparison with Four Different Generation Devices

HIFU has been recognized as a minimally invasive treatment option for localized prostate cancer. The purpose of the study was to assess with a long-term outcome of HIFU for prostate cancer. From January 1999, a total of 657 patients who had HIFU with at least 2 year follow-up were treated with four different types of Sonablate registered (Focus Surgery, Indianapolis, USA) devices. Thirty-three patients were treated with Sonablate registered 200 (S200) from 1999 to 2001, 406 patients with Sonablate registered 500 (S500) from 2001 to 2005, 200 patients with Sonablate registered 500 version 4 (V4) from 2005-2008 and 19 patients with Sonablate registered 500 TCM (TCM) from 2007. Biochemical disease-free survival rate (bDFS) in all patients was 59% in 8 years. bDFS in 8 years in patients with S200 and S500 groups were 55% and 56%, and bDFS in 4 and 2 years in patients with V4 and TCM group were 72% and 84%, respectively. bDFS in low, intermediate, and high risk groups were 75%, 54%, and 43% in S200/S500 and 93%, 72%, and 58% in V4/TCM group. Negative prostate biopsy rate after HIFU was 97% in S200, 79% in S500, 94% in V4 and 100% in TCM group. HIFU as primary therapy for prostate cancer is indicated in patients with low- and intermediate-risk (T1-T2b N0M0 disease, a Gleason score of <=7, a PSA level of <20 ng/mL) and a prostate volume of less than 40 mL. The rate of clinical outcome has significantly improved over the years due to technical improvements in the device.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Salvage High-intensity Focused Ultrasound for the Recurrent Prostate Cancer after Radiotherapy

To investigate the use of minimally invasive high-intensity focused ultrasound (HIFU) as a salvage therapy in men with localized prostate cancer recurrence following external beam radiotherapy (EBRT), brachytherapy or proton therapy. A review of 20 cases treated using the Sonablate registered 500 HIFU device, between August 28, 2002 and September 1, 2009, was carried out. All men had presumed organ-confined, histologically confirmed recurrent prostate adenocarcinoma following radiation therapy. All men with presumed, organ-confined, recurrent disease following EBRT in 8 patients, brachytherapy in 7 patients or proton therapy in 5 patients treated with salvage HIFU were included. The patients were followed for a mean (range) of 16.0 (3-80) months. Biochemical disease-free survival (bDFS) rates in patients with low-intermediate and high risk groups were 86% and 50%, respectively. Side-effects included urethral stricture in 2 of the 16 patients (13%), urinary tract infection or dysuria syndrome in eight (26%), and urinary incontinence in one (6%). Recto-urethral fistula occurred in one patient (6%). Transrectal HIFU is an effective treatment for recurrence after radiotherapy especially in patients with low- and intermediate risk groups.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ion energy distribution near a plasma meniscus with beam extraction for multi element focused ion beams

An earlier study of the axial ion energy distribution in the extraction region (plasma meniscus) of a compact microwave plasma ion source showed that the axial ion energy spread near the meniscus is small ({approx}5 eV) and comparable to that of a liquid metal ion source, making it a promising candidate for focused ion beam (FIB) applications [J. V. Mathew and S. Bhattacharjee, J. Appl. Phys. 105, 96101 (2009)]. In the present work we have investigated the radial ion energy distribution (IED) under the influence of beam extraction. Initially a single Einzel lens system has been used for beam extraction with potentials up to -6 kV for obtaining parallel beams. In situ measurements of IED with extraction voltages upto -5 kV indicates that beam extraction has a weak influence on the energy spread ({+-}0.5 eV) which is of significance from the point of view of FIB applications. It is found that by reducing the geometrical acceptance angle at the ion energy analyzer probe, close to unidirectional distribution can be obtained with a spread that is smaller by at least 1 eV.

43 PARTICLE ACCELERATORS↗

Micron-focused ion beamlets

A multiple beam electrode system (MBES) is used to provide focused ion beamlets of elements from a compact microwave plasma. In this study, a honeycomb patterned plasma electrode with micron size apertures for extracting ion beamlets is investigated. The performance of the MBES is evaluated with the help of two widely adopted and commercially available beam simulation tools, AXCEL-INP and SIMION, where the input parameters are obtained from our experiments. A simple theoretical model based upon electrostatic ray optics is employed to compare the results of the simulations. It is found that the results for the beam focal length agree reasonably well. Different geometries are used to optimize the beam spot size and a beam spot {approx}5-10 {mu}m is obtained. The multiple ion beamlets will be used to produce microfunctional surfaces on soft matter like polymers. Additionally, the experimental set-up and plans are presented in the light of above applications.

43 PARTICLE ACCELERATORS↗

Analysis of the degradation induced by focused ion Ga{sup 3+} beam for the realization of piezoelectric nanostructures

Piezoelectric nanostructures (islands of dimensions in the lateral size range 50-500 nm) have been fabricated by focused Ga{sup 3+} ion beam (FIB) etching on PbZr{sub 0.54}Ti{sub 0.46}O{sub 3} thin films obtained by magnetron sputtering. The degradation induced by the etching process is investigated through the evolution of electromechanical activity measured by means of local piezoelectric hysteresis loops produced by piezoresponse force microscopy. The analysis of surface potential is performed by kelvin force microscopy and the measurement of current-voltage curves is carried out by conducting atomic force microscopy. Two kinds of structures, namely one based on crystallized films and the other based on amorphous ones, were studied. In this latter case, the amorphous films are postannealed after etching to obtain crystallized structure. For the structures based on the crystallized and then etched films, no piezoelectric signal was registered that evidences a serious degradation of material induced by Ga{sup 3+} ion implantation. For the structures based on the films etched in amorphous state and then crystallized, the piezoresponse signal was near to that of the reference films (crystallized and not etched) whatever were the ion dose and the island dimensions. Even for very small lateral size (50 nm), no size effect was observed. The island shapes fabricated by Ga{sup 3+} FIB etching process (islands with less than 50 nm lateral size) show a limitation of FIB processing and electron beam lithography seems to be necessary.

36 MATERIALS SCIENCE↗

Effects of electron irradiation on the ferroelectric 180 deg. in-plane nanostripe domain structure in a thin film prepared from a bulk single crystal of BaTiO{sub 3} by focused ion beam

Effects of electron irradiation on the ferroelectric 180 deg. in-plane nanostripe domain structure in a thin film prepared from a bulk single crystal of BaTiO{sub 3} by focused ion beam were studied. The domain structure transformed into a characteristic 90 deg. in-plane nanostripe domain structure under intense electron irradiation. In particular, an unconventional triangular 90 deg. in-plane nanostripe domain structure was observed. Polarization analysis suggests the existence of an incomplete or half tetradomain vortex at the boundary of the triangular domain structure. Together with the help of phase-field simulations using time-dependent Ginzburg-Landau equations, it is suggested that such a domain structure is created by an anisotropic in-plane electric field, which is plausibly induced by an anisotropic interaction of the incident electron beam with the ferroelectric material.

36 MATERIALS SCIENCE↗

Focused ion beam and electron microscopy characterization of nanosharp tips and microbumps on silicon and metal thin films formed via localized single-pulse laser irradiation

Cross-sections of laser fabricated nanosharp tips and microbumps on silicon and metal thin films are produced and examined in this work. These structures are formed with a Q-switched neodymium doped yttrium aluminum garnet nanosecond-pulse laser, emitting at its fourth harmonic of 266 nm, using a mask projection technique to generate circular laser spots, several microns in diameter. Cross-section of selected structures were produced using a focused ion beam and were characterized via electron microscopy. The diffraction patterns of the silicon samples indicate that the laser formed tip maintains the same single crystal structure as the original silicon film. Examinations of the laser formed structures in metal films confirm that the microbumps are hollow, while revealing that the vertical protrusions are solid.

36 MATERIALS SCIENCE↗

Mechanisms of nanodot formation under focused ion beam irradiation in compound semiconductors

We have examined the responses of GaAs, InP, InAs, and AlAs to 30 keV focused ion beam (FIB) irradiation and applied a unified model that consistently explains the observed effects. Nanodots were observed to form on GaAs, InP, and InAs under irradiation at normal incidence, while nanodots are not observed on AlAs. The FIB response and nanodot formation behavior of each material is discussed with regard to a few basic material properties and a model for nanodot creation and growth by the action of preferential sputtering and Ostwald ripening. The model predicts the development of a stable average nanodot size with increasing ion dose, with the average nanodot size depending on the excess group III adatom yield, adatom surface diffusion rate, and surface tension. These predictions qualitatively agree with the experimentally observed trends for GaAs and InP. They also agree for the initial nanodot formation on InAs, but this material system exhibits a sudden transition in the nanodot size distribution. The model predicts that nanodots will have difficulty forming and growing on AlAs, which is also in agreement with our experimental results.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Influence of pulse duration, energy, and focusing on laser-assisted water condensation

We investigate the influence of laser parameters on laser-assisted water condensation in the atmosphere. Pulse energy is the most critical parameter. Nanoparticle generation depends linearly on energy beyond the filamentation threshold. Shorter pulses are more efficient than longer ones with saturation at {approx}1.5 ps. Multifilamenting beams appear more efficient than strongly focused ones in triggering the condensation and growth of submicronic particles, while polarization has a negligible influence on the process. The data suggest that the initiation of laser-assisted condensation relies on the photodissociation of the air molecules rather than on their photoionization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-focusing of intense high frequency electromagnetic waves in a collisional magnetoactive plasma

The self-focusing of an intense electromagnetic beam in a collisional magnetoactive plasma has been investigated by the perturbation method. Considering the relativistic and ponderomotive nonlinearities and the first three terms of perturbation expansion for the electron density and velocity, the nonlinear wave equation is obtained. This wave equation is solved by applying the source dependent expansion method and the evolution of electromagnetic beam spot-size is discussed. It is shown that the laser spot-size decreases with increasing the collision frequency and external magnetic field strength.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of air breakdown with a focusing lens on ultrashort laser ablation

The effect of air breakdown on ultrashort laser ablation is investigated in this letter using an integrated simulation method on atomistic level. The generation of air breakdown with different laser peak power densities in the range from 10{sup 13} to 10{sup 16} W/cm{sup 2} and various focusing conditions is analyzed. Air breakdown is generated directly from laser energy absorption through avalanche ionization at a high power density (over 10{sup 14} W/cm{sup 2}), while at a lower power density, air breakdown is assisted by a metal target near the focal region. The laser energy loss due to air breakdown and its effect on laser ablation are studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dual-channel, focusing x-ray spectrograph with uniform dispersion for Z pinch plasmas measurement

A dual-channel, focusing x-ray spectrograph with uniform dispersion (i.e., the linear dispersion of this spectrograph is a constant) is described for measuring the x-ray spectra emission from the hot, dense Al Z pinch plasmas. The spectrograph uses double uniform-dispersed crystals (e.g., a Quartz 1010 crystal and a Mica 002 crystal) as dispersion elements and a double-film box as detector to achieve the simultaneous recording of the time integrated spectrum covering a wide spectral range of {approx}5-9 A. Since this spectrograph disperse the x-rays on the detector plane with uniform spacing for every wavelength, it needs not the calibration of the wavelength with spatial coordinate, thereby own the advantages of easiness and veracity for spectra identification. The design of this spectrograph and the example of experiment on the ''Yang'' accelerator are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Role of the substrate in the electrical transport characteristics of focused ion beam fabricated nanogap electrode

Precise metallic nanogap structure is fabricated on a glass substrate by using a 30 keV focused Ga ion beam. While investigating the I-V behavior of the nanogap structure, tunneling through the substrate has been found to play a vital role in the electrical transportation process. Substrate breakdown occurs at a certain applied voltage and a metal vapor state is initiated through intense heat generation at the nanogap region. The experimental observation confirms the role of the substrate in the explosion process. Metallic spherical particles are formed during cooling/condensation of the metal vapors or splashing of the liquid droplets showing a wide distribution of size from few tens of nanometers to few microns.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗