Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Automatic Labeling for Entity Extraction in Cyber Security

Timely analysis of cyber-security information necessitates automated information extraction from unstructured text. While state-of-the-art extraction methods produce extremely accurate results, they require ample training data, which is generally unavailable for specialized applications, such as detecting security related entities; moreover, manual annotation of corpora is very costly and often not a viable solution. In response, we develop a very precise method to automatically label text from several data sources by leveraging related, domain-specific, structured data and provide public access to a corpus annotated with cyber-security entities. Next, we implement a Maximum Entropy Model trained with the average perceptron on a portion of our corpus (~750,000 words) and achieve near perfect precision, recall, and accuracy, with training times under 17 seconds.

Automatic Labeling↗

LL/ILW: Post-Qualification of Old Waste through Non-Destructive Extraction of Barrels from Cement Shields - 13535

Currently there is a large number of radioactive waste drums entombed in cement shields at German nuclear power plants. These concrete containers used in the past for the waste are not approved for the final repository. Compliance with current acceptance criteria of the final repository has to be proven by qualification measures on the waste. To meet these criteria, a new declaration and new packing is necessary. A simple non-destructive extraction of about 2000 drums from their concrete shields is not possible. So different methods were tested to find a way of non-destructive extraction of old waste drums from cement shields and therefore reduce the final repository volume and final repository costs by using a container accepted and approved for Konrad. The main objective was to build a mobile system to offer this service to nuclear plant stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Peculiarities of highly burned-up NPP SNF reprocessing and new approach to simulation of solvent extraction processes

Substantiation, general description and performance characteristics of a reprocessing flowsheet for WWER-1000 spent fuel with burn-up >60 GW*day/t U is given. Pu and U losses were <0.1%, separation factor > 10{sup 4}; their decontamination factor from γ-emitting fission products was 4*10{sup 4} and 3*10{sup 7}, respectively. Zr, Tc, Np removal was >98% at U and Pu losses <0.05%. A new approach to simulation of extraction equilibrium has been developed. It is based on a set of simultaneous chemical reactions characterized by apparent concentration constants. A software package was created for simulation of spent fuel component distribution in multistage countercurrent extraction processes in the presence of salting out agents. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gadolinium speciation with Tetradentate, N-donor extractants for minor actinide/lanthanide separation: an XRD, mass spectrometry and EPR study

The hydrophobic organic molecules CyMe{sub 4}-BTPhen (1) and CyMe{sub 4}-BTBP (2) have been developed and tuned over many years to be able to separate the trivalent actinides from the trivalent lanthanides (Ln) selectively in bi-phasic solvent extraction processes for the separation of the long-lived radio-toxic minor actinides from spent nuclear fuel. The ability of these N-donor ligands to perform this separation is poorly understood, as is their speciation with the metal ions when extracted into the organic phase. Our previous work has shown Ln{sup 3+} speciation to be largely 1:2 Ln:L in nature with another small molecule, either water or nitrate, occupying a cavity between the tetradentate bound N-donor ligands. The identity of the small molecule changes across the lanthanide series, and here we continue investigations into this speciation. Complexes of these N-donor ligands with Gd{sup 3+} have been synthesised and characterised by X-ray crystallography, mass spectrometry and EPR spectroscopy. We show that the N-donor ligands have no effect on the electronic configuration of Gd{sup 3+} and that the lanthanide contraction with the steric rigidity of the N-donor ligand appears to determine the size of the cavity between the coordinated ligands. This in turn appears to control the identity of the small molecule on the ninth site in the 1:2 Gd:L species. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

New method of uranium and plutonium extraction in reprocessing of the spent nuclear fuel

It is shown that a two-stage process of uranium and plutonium extraction during the reprocessing of spent nuclear fuel solves the problem of obtaining a high-concentrated extract without increasing the loss risk with raffinate and avoids the accumulation of plutonium in the unit. A possible further optimization of the process would be the creation of steps inside the stages.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessing Soil Vapor Extraction Remediation Performance and Closure: A Review - 12188

Soil vapor extraction (SVE) is a baseline remediation approach for volatile contaminants. While SVE is generally effective for removal of contaminants from higher permeability portions of the vadose zone, contamination in low-permeability zones can persist due to mass transfer processes that limit the removal effectiveness. Thus, a diminishing rate of contaminant extraction over time is typically observed, yet contamination may remain in low-permeability zones. Under these conditions, SVE performance needs to be evaluated to determine whether the system should be optimized, terminated, or transitioned to another technology to replace or augment SVE. Methodologies have been developed to quantify SVE performance over time and to evaluate the impact of persistent vadose zone contamination sources on groundwater quality. Recently, these methods have applied mass flux/discharge concepts to quantify contaminant source strength. Methods include field measurement techniques using the SVE system to quantify source strength and predictive analyses with analytical and numerical models to evaluate the impact of the contaminant source on groundwater. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Efforts to Improve Efficiency of Extraction Well Operation at the Fernald Preserve, Harrison, Ohio - 16177

The Fernald Preserve, a former uranium processing facility that produced high-purity uranium metal products during the Cold War, is located in southwest Ohio. The facility became a US Department of Energy Office of Legacy Management (LM) site in November 2006, following completion of the Comprehensive Environmental Response, Compensation, and Liability Act environmental remediation and site restoration (with the exception of groundwater). When the site was turned over to LM, approximately 76.5 ha of the Great Miami Aquifer remained contaminated with uranium above the final remediation level of 30 μg/L. Here, uranium contamination is being removed from groundwater in the Great Miami Aquifer through a pump-and-treat operation, which is predicted to continue until 2033. Twenty extraction wells pump about 30 million liters per day. Operation of the system is impacted by iron in the groundwater that promotes iron fouling of the well pumps, motors, and screens. The design of the well field evolved over 21 years and reflected a conservative system that could respond to a wide range of pumping conditions. For instance, some of the extraction wells were sized with pumps and motors that would allow the well to pump up to 1890 L/min (500 gpm) if warranted. The added flexibility, though, came at the cost of operational efficiency. We describe the efforts that have been taken by LM since the Fernald site was transferred to LM to mitigate the operational impacts from the iron fouling aquifer conditions and improve the efficiency of the well-field operation. Variable-frequency drives were installed at six wells to replace flow control valves. Several wells with oversized pumps and motors were changed from 24-hour per day operation to 8-hour per day operation to allow the pumps to operate closer to their design flow rates. Pumps and motors were 'right-sized' at many wells to improve pumping efficiency. The process used to rehabilitate (or clean) well screens was improved, and a process was developed to clean pumps without having to pull them from the well. To reduce pressure drops, improvements were also made to the configuration of the discharge piping. A new control system was installed for each well to allow local control and local tracking of energy used. The amount of energy used daily compared to number of gallons pumped provides a method to assess pump performance and determine when action is necessary to restore well pump efficiency. Additionally, the metrics being employed to help quantify well-field efficiency improvements are described, and the benefits achieved by proactively managing the pump-and-treat operation are presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Uranium extraction by apricot shell - 16501

In this paper, use of highly contaminated mine and drainage waters by local residents which lead to increase of doses is described. Uranium concentration in this water is studied. Possibilities of uranium extraction by cheap and local sorbent (almonds, peach and apricot shells) were investigated. It is revealed that apricot shell has very good sorption properties for uranium extraction. Detailed sorption parameters of apricot shell are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Complexation and Solvent Extraction Studies of High Valency Actinides by Hard/Soft Donor Schiff Base Ligands

Successful separation of the mid actinides (U, Np, Pu, Am) from other elements is imperative for drastically lowering the long term radiotoxicity of SNF. Ubiquitous to these mid actinides is a wide range of oxidation states (+III, +IV, +V, +VI) where the +V and +VI oxidation states exist in a linear dioxo actinyl cation AnO{sub 2}{sup n+} (O=An=O){sup n+} guaranteeing unique ligand coordination about the equatorial plane. Multidentate Schiff base ligands which possess nitrogen and oxygen donor groups can accommodate the steric demands of the actinyl cations as well as providing selectivity for actinides in a separation process. Group extraction or retention of the mid actinides in a biphasic solvent extraction process can be achieved by complexation of their actinyl species by Schiff base ligands in one phase while all other non actinyl cations are complexed in the other phase. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Causality Extraction from Nuclear Licensee Event Reports Using a Hybrid Framework

In this paper, we proposed a hybrid framework for causality detection and extraction in LER documents. The main contributions are summarized below. We 1) built an LER corpus with 20,129 text samples for causality analysis, 2) developed an interactive tool was developed for labeling cause-effect pairs, 3) built a deep learning-based approach for causal relation detection, and 4) built a knowledge-based cause-effect extraction approach.

99 GENERAL AND MISCELLANEOUS↗

An Overview in the Development of a Multi-Sensor Data Science System for Monitoring a Solvent Extraction Process

To enhance nuclear nonproliferation stewardship, Idaho National Laboratory is building the Beartooth nuclear fuel cycle processing test bed. The Beartooth test bed will allow researchers the opportunity to study nuclear fuel processing operations including the use of centrifugal contactors in solvent extraction processes. The test bed is designed to support data collection and machine learning to monitor process operations. As part of this project, researchers will study data collected from a host of sensors that have not been typically used to monitor solvent extraction processes such as vibration, acoustic, colormetric, and thermal measurement data. The goal of this research is to employ machine learning and data analytics to study the confluence of signals collected from both traditionally and non-traditionally used sensors to provide operator process awareness and discover process anomalies. An overview of planned sensors and experiments that will focus on signal discovery will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Overview in the Development of a Multi-Sensor Data Science System for Monitoring a Solvent Extraction Process

To enhance nuclear nonproliferation stewardship, Idaho National Laboratory is building the Beartooth nuclear fuel cycle processing test bed. The Beartooth test bed will allow researchers the opportunity to study nuclear fuel processing operations including the use of centrifugal contactors in solvent extraction processes. The test bed is designed to support data collection and machine learning to monitor process operations. As part of this project, researchers will study data collected from a host of sensors that have not been typically used to monitor solvent extraction processes such as vibration, acoustic, colormetric, and thermal measurement data. The goal of this research is to employ machine learning and data analytics to study the confluence of signals collected from both traditionally and non-traditionally used sensors to provide operator process awareness and discover process anomalies. An overview of planned sensors and experiments that will focus on signal discovery will be presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of a Multi Sensor Data Science System for Monitoring a Solvent Extraction Process

Idaho National Laboratory is designing and constructing a solvent extraction test bed, Beartooth, as part of a nuclear fuel cycle stewardship initiative. The test bed will provide facilities and equipment for testing novel extraction processes and give early career scientists opportunities to gain skills in performing separations chemistry. The test bed is being uniquely designed to enable machine learning capabilities for the characterization of chemical process operations. One of the intentions of incorporating machine learning methods is to provide process operators with enhanced situational awareness for the optimization of separations techniques and possible detection of a diversion event. As a result, the objective of this Laboratory Directed Research and Development project is to develop a multi-sensor data collections system and implement machine learning techniques on signals from an existing centrifugal contactor cascade to identify equipment usage and process events. This presentation will provide an overview of sensors used and experiments conducted to date.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mono-ionizable calix[4]arene-benzocrown-6 ligands in 1,3-alternate conformations: synthesis, structure and silver(I) extraction

Two series of novel mono-ionizable calix[4]arene-benzocrown-6 ligands in 1,3-alternate conformations are synthesized. In one series, the proton-ionizable group (PIG) is attached to the para position of one aromatic ring in the calixarene framework, thereby positioning it over the polyether ring cavity. In the other series, the PIG is a substituent on the benzo group in the polyether ring. This orients the PIG away from the crown ether cavity. In addition to carboxylic acid functions, the PIGs include N-(X)sulfonyl carboxamide groups. With X group variation from methyl to phenyl to 4-nitrophenyl to trifluoromethyl, the acidity of the PIG is 'tuned'. Solvent extraction of Ag{sup +} from aqueous solutions into chloroform is used to probe the influence of structural variation within the mono-ionizable calixcrown ligand on metal ion extraction efficiency, including the identity and acidity of the PIG and its orientation with respect to the polyether ring.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility HRIBF at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams RIBs. Of these, the workhorse is an electron beam plasma EBP ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 IRIS2, for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

Recognition and Extraction of Cesium Hydroxide and Carbonate by Using a Neutral Multitopic Ion‐Pair Receptor

Abstract Current approaches to lowering the pH of basic media rely on the addition of a proton source. An alternative approach is described herein that involves the liquid–liquid extraction‐based removal of cesium salts, specifically CsOH and Cs 2 CO 3 , from highly basic media. A multitopic ion‐pair receptor ( 2 ) is used that can recognize and extract the hydroxide and carbonate anions as their cesium salts, as confirmed by 1 H NMR spectroscopic titrations, ICP‐MS, single‐crystal structural analyses, and theoretical calculations. A sharp increase in the pH and cesium concentrations in the receiving phase is observed when receptor 2 is employed as a carrier in U‐tube experiments involving the transport of CsOH through an intervening chloroform layer. The pH of the source phase likewise decreases.

He, Qing↗

Fully automated Liquid Extraction-Based Surface Sampling and Ionization Using a Chip-Based Robotic Nanoelectrospray Platform

A fully automated liquid extraction-based surface sampling device utilizing an Advion NanoMate chip-based infusion nanoelectrospray ionization system is reported. Analyses were enabled for discrete spot sampling by using the Advanced User Interface of the current commercial control software. This software interface provided the parameter control necessary for the NanoMate robotic pipettor to both form and withdraw a liquid microjunction for sampling from a surface. The system was tested with three types of analytically important sample surface types, viz., spotted sample arrays on a MALDI plate, dried blood spots on paper, and whole-body thin tissue sections from drug dosed mice. The qualitative and quantitative data were consistent with previous studies employing other liquid extraction-based surface sampling techniques. The successful analyses performed here utilized the hardware and software elements already present in the NanoMate system developed to handle and analyze liquid samples. Implementation of an appropriate sample (surface) holder, a solvent reservoir, faster movement of the robotic arm, finer control over solvent flow rate when dispensing and retrieving the solution at the surface, and the ability to select any location on a surface to sample from would improve the analytical performance and utility of the platform.

Kertesz, Vilmos↗

Analysis of Chloroquine and Metabolites Directly from Whole-body Animal Tissue Sections by Liquid Extraction Surface Analysis (LESA) and Tandem Mass Spectrometry

The rapid and direct analysis of the amount and spatial distribution of exogenous chloroquine and chloroquine metabolites from tissue sections by liquid extraction surface sampling analysis coupled with tandem mass spectrometry (LESA-MS) was demonstrated. LESA-MS results compared well with previously published chloroquine quantification data collected by organ excision, extraction and fluorescent detection. The ability to directly sample and analyze spatially-resolved exogenous molecules from tissue sections with minimal sample preparation and analytical method development has the potential to facilitate the assessment of target tissue penetration of pharmaceutical compounds, to establish pharmacokinetic/pharmacodynamic (PK/PD) relationships, and to complement established pharmacokinetic methods used in the drug discovery process during tissue distribution assessment.

chloroquine↗