Godiva-IV Dosimetry Exercise 2022 Preliminary Results
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The 2022 Hunga eruption was a global event recorded by all three Comprehensive Test Ban Treaty Organization (CTBTO) International Monitoring System (IMS) geophysical waveform sensor technologies: seismic, infrasound, and hydroacoustic. Large volcanic eruptions are rare and additionally present an opportunity to test seismoacoustic detection, location, and identification methods for nuclear explosion monitoring.
In a number of institutions and companies, researchers and engineers are developing modeling numerical frameworks that are used to predict the aerodynamic noise emission from a wind turbine rotor. The simulation codes vary from empirically-tuned engineering models to high-fidelity computational ones. Their common feature is the fact that they all specifically model the main aerodynamic noise mechanisms occurring at the rotating blades, namely trailing edge noise and turbulent inflow noise. Nevertheless, it can be expected that these different modeling frameworks will produce different results for a same given rotor design, and identical operating conditions. Trailing edge noise is put at the forefront of the study as it is recognized as the main audible source of noise from wind turbines. The present benchmark aims at comparing the results from the different modeling approaches, and drawing some conclusions from these comparisons. This effort, denoted as Wind Turbine Noise Code benchmark, was initiated in 2019 as a joint-activity between the IEA Wind Task 39 (Quiet Wind Turbine Technology) and Task 29 (Detailed Aerodynamics of Wind Turbines, now Task 47). In addition to the investigation of the noise emissions themselves, the rotor aerodynamic characteristics are investigated as they have a significant impact on the noise generation mechanisms. A number of test cases are defined and the aerodynamic and aeroacoustic predictions from the various models are compared. There exist some discrepancies between the different methods, but it is difficult to conclude if one methodology is better than another in order to design a wind turbine with noise as a constraint.
Abstract not provided.
Abstract not provided.
The Mound Site facility near Miamisburg, Ohio, opened in 1948 to support early atomic weapons programs. It grew into a research, development, and production facility performing work in support of the U.S. Department of Energy (DOE) weapons and energy programs. The plant was in operation until 1995. During the course of operation, an onsite landfill was created. The landfill was located over a finger of a buried valley aquifer, which is a sole drinking water source for much of the Miami Valley. In the 1980's, volatile organic compounds (VOCs) were discovered in groundwater at the Mound site. The site was placed on the National Priorities List on November 21, 1989. DOE signed a Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) Federal Facility Agreement with the U.S. Environmental Protection Agency (EPA) and the Ohio Environmental Protection Agency. The agreement became effective in October 1990. The area that included the landfill was designated Operational Unit 1 (OU-1). In 1995, a Record of Decision was signed that called for the installation and operation of a pump and treatment (P and T) system in order to prevent the VOCs in OU-1 groundwater from being captured by the onsite water production wells. In addition to the P and T system, a soil vapor extraction (SVE) system was installed in 1997 to accelerate removal of VOCs from groundwater in the OU-1 area. The SVE system was successful in removing large amounts of VOCs and continued to operate until 2007, when the amount of VOCs removed became minimal. A rebound study was started in February 2003 to determine how the groundwater system and contaminants would respond to shutting down the P and T system. The rebound test was stopped in February 2004 because predetermined VOC threshold concentrations were exceeded down-gradient of the landfill. The P and T and SVE systems were restarted after the termination of the rebound test. In 2006, the remediation of the Mound site was completed and the site was declared to be protective of human health and the environment, as long as the institutional controls are observed. The institutional controls that apply to the OU-1 area include provisions that no soil be allowed to leave the site, no wells be installed for drinking water, and the site may be approved only for industrial use. The onsite landfill with the operating CERCLA remedy remained. However, the Mound Development Corporation lobbied Congress for funds to remediate the remaining onsite landfill to allow for property reuse. In 2007 DOE received funding from Congress to perform non-CERCLA removal actions at OU-1 to excavate the site sanitary landfill. In 2009, DOE received American Recovery and Reinvestment Act funding to complete the project. Excavation of the landfill occurred intermittently from 2006 through 2010 and the majority of the VOC source was removed; however, VOC levels near the P and T system remained greater than the EPA maximum contaminant levels (MCLs). Presently, groundwater is contained using two extraction wells to create a hydraulic barrier to prevent down-gradient migration of VOC-impacted groundwater. Since the primary contamination source has been removed, the feasibility of moving away from containment to a more passive remedy, namely monitored natural attenuation (MNA), is being considered. A second rebound study was started in June 2011. If contaminant and groundwater behavior met specific conditions during the study, MNA would be evaluated and considered as a viable alternative for the groundwater in the OU-1 area. From June through December 2011, the second rebound study evaluated the changes in VOC concentrations in groundwater when the P and T system was not in operation. As the study progressed, elevated concentrations of VOCs that exceeded predetermined trigger values were measured along the down-gradient boundary of the study area, and so the P and T system was restarted. It was determined that a discrete area with VOC concentrations greater than the MCLs was present in groundwater down-gradient of the extraction wells. The source was not identified, but the contamination was thought not to be caused by residually contaminated soil beneath the former landfill. The data collected so far supports the consideration of MNA as a viable alternative to hydraulic containment. Additional investigations are being performed to identify possible sources or pathways of VOCs in groundwater that may be contributing to the elevated VOC levels measured down-gradient of the extraction well system. Data from this additional investigation will be used to determine whether the VOCs detected down-gradient of the hydraulic boundary are the result of residual soil contamination, a previously unknown contribution of VOC-contaminated water entering the groundwater outside the capture zone of the extraction wells, or a pulse of VOC-contaminated groundwater from the OU-1 landfill that occurred during the rebound study. (authors)
The high-temperature gas-cooled reactor (HTGR) is an advanced reactor concept that has received considerable attention over the last 60 years. HTGRs boast high coolant outlet temperatures, passive safety, and large margins to fuel failure. Recent years have seen increasing interest in HTGRs, whether large-scale HTGRs for electricity or process heat applications or as microreactors serving remote communities. HTGRs have considerable potential to fulfill these applications, but modeling and simulation tools typically used for reactor safety analysis have not been validated for HTGR modeling. The High-Temperature Test Facility (HTTF) was constructed at Oregon State University (OSU) to provide validation data for HTGR modeling. Recently, Idaho National Laboratory (INL), OSU, Argonne National Laboratory, Canadian Nuclear Laboratories, and the University of Tennessee Knoxville have collaborated to develop an HTGR thermal hydraulics benchmark based on HTTF experiments. This summary presents results from a portion of that benchmark using RELAP5-3D
The goals are to test and explore the DOE National Labs ability to quickly map, characterize and analyze an event involving Mexico's energy infrastructure system in the wake of a major disruption of energy supplies from Mexico to the US. Focus on the economic impacts and system interdependencies as well as analysis related to restoration and recovery issues.
Previous exercise in space has lacked sufficient loads to maintain preflight cardiovascular and musculoskeletal mass and function. Lower body negative pressure (LBNP) produces a static force equivalent to one Earth body weight by each 52 mm Hg of LBNP during supine posture. LBNP also provides transmural blood pressures simulating upright exercise. Thus, this artificial-gravity concept may help maintain cardiovascular and musculoskeletal systems of crewmembers during prolonged exposure to microgravity. Currently available, bungee cord assisted, treadmill exercise is limited by harness discomfort, lower than normal loads, abnormal post-flight gait, and the absence of gravitational blood pressures within the vascular system. PURPOSE: This project evaluates a method to create artificial gravity using supine LBNP treadmill exercise to prevent loss of physiologic function in microgravity simulated by 30 days of bed rest. Identical twins were used as volunteers so that statistical power could be maximized. This countermeasure is being transitioned to space flight. CURRENT STATUS OF RESEARCH Methods: Six sets of identical twins (6 females and 14 males, 21-36 years) remained in 6 head-down tilt (HDT) bed rest for 30 days to simulate prolonged microgravity. Six subjects were randomly selected to exercise supine in an LBNP chamber for 40 minutes six days per week (EX group), while their twin brothers served as non-exercise controls (CON). Pressure within the exercise LBNP chamber was adjusted to increase load, hence increasing exercise intensity. During supine treadmill exercise, LBNP (52-63 mmHg) was applied to produce foot ward forces equivalent to those for upright running on Earth at 1.0-1.2 times body weight (BW) and subjects performed an interval exercise protocol (40-80% peak exercise capacity [VO2pk]). Five minutes of resting LBNP immediately followed each exercise session. Results: Orthostatic tolerance time decreased significantly after 30 days bed rest in the CON group, but was relatively maintained in the EX group. VO2pk was maintained in EX males, but not in CON males. Isokinetic knee strength (extension, peak torque) decreased significantly in CON males, but was preserved in EX males. The EX group had significantly higher spine muscle strength after bed rest than the CON group. The cross-sectional area of spinal muscle at L4/5 level decreased significantly in the CON group but not in the EX group. Urinary n-telopeptide excretion, an index of bone resorption, was increased during bed rest in CON, but not in EX subjects. This suggests protection by LBNP exercise against the increase in bone resorption typically seen in simulated and actual microgravity. Significant changes in bone mineral density (BMD) in the spine and ribs were observed in CON subjects, but not in EX subjects. Conclusions: Our treadmill exercise protocol within LBNP plus a short period of post-exercise LBNP maintains orthostatic responses, upright exercise capacity and other important physiologic parameters during bed rest. These results document the efficacy of our apparatus and exercise protocol for maintaining physiologic structure and function during long-duration microgravity as simulated by 30 days of HDT bed rest. FUTURE PLANS: More sets of female identical twins are needed to reach significance. The LBNP exercise chamber will be redesigned for flight.
INTRODUCTION: The chosen exercise device for the Orion Multi-purpose Crew Vehicle (MPCV) for Artemis missions is the Orion Flywheel (OFW), which was selected in 2017 from a pool of exercise devices. The Orion Flywheel is to be installed in the MPCV for its first use during the Artemis II mission and will be utilized for subsequent Artemis missions. The OFW provides the capability to perform both resistive and aerobic exercises while taking up a small volume and not requiring power. Aerobic exercise consists of rowing while resistive exercise includes the deadlift, harness squat, and deadlift high pull among others. The efficacy of the OFW as an exercise countermeasure to spaceflight deconditioning has not yet been fully evaluated. A future HRP-funded study using head-down tilt bed rest is planned to evaluate the efficacy of the OFW to mitigate aerobic and muscular deconditioning. The OFW, made by KBR, is a specialized device that poses high costs for purchase and maintenance. The aim of the study is to determine if a commercially available alternative could be used as a backup for the OFW during the bed rest study or as an alternative in other studies. This study seeks to compare the loading profile and mechanics of a commercial flywheel device (kBox Pro) with the three resistance settings of the OFW using a controlled, instrumented setup to validate its acceptability as a backup. METHODS: An experimental setup was designed to simulate human use of the OFW. Flywheel devices can have varied actuated inertial mass and strap length. The inertial mass refers to the flywheel itself or the object that spins as the result of the movement of the strap. The OFW has three gears actuated with a lever, with the low gear used for aerobic rowing and the medium and high gears used for resistance exercises. These gears correspond to increasing flywheel inertia, which corresponds to a certain number and sizes of inertial plates on a commercial flywheel. The kBox Pro has varied sizes of inertial discs that are installed to the external shaft of the device and can be configured to roughly match the inertia seen in the OFW per gear setting. The strap length can be adjusted to allow for different ranges of motion. The experimental setup allows for the simulation of rowing, harness squats, and deadlift high pulls with corresponding exercise strap lengths. All three OFW gears are to be tested, as well as multiple combinations of kBox discs. The setup was created using a system of pulleys and cables to minimize friction loss. The system is actuated through the dropping of a connected mass which, through the pulley system, pulls the strap of the exercise device upwards as if a human was exercising. A string potentiometer and tensile force transducer are used to measure strap displacement and strap force, respectively. The masses dropped are exercise chains that simulate the decrease in force observed throughout a typical exercise. As the chains are lowered to the ground, they begin to spool and therefore are no longer subjecting the exercise device’s strap to their load. This setup was designed to provide realistic loads and protect the OFW from damage, an important precaution because it’s the only available unit for research and ground operations. Data is to be collected across simulated exercises and with different strap lengths, with the same conditions collected on both the OFW and the kBox Pro. RESULTS: Data collection is ongoing for the kBox and the Orion Flywheel. CONCLUSIONS: Study results will inform if the OFW and a kBox Pro device can be deemed mechanically similar. Depending on the results, additional data collection may be required to assess the user experience between the devices. A key result of this study is a mechanical characterization of the OFW device, demonstrating the load and force profile using a repeatable test method. This data will guide next steps on potential kBox Pro modifications needed to produce a comparable exercise experience to the OFW.
1. Isometric handgrip (IHG) exercise increases sweat rate and arterial blood pressure, and both remain elevated during post-exercise ischaemia. The purpose of this study was to identify whether the elevation in arterial blood pressure during post-exercise ischaemia contributes to the increase in sweating. 2. In normothermia and during whole-body heating, 2 min IHG exercise at 40% maximal voluntary contraction, followed by 2 min post-exercise ischaemia, was performed with and without bolus intravenous administration of sodium nitroprusside during the ischaemic period. Sodium nitroprusside was administered to reduce blood pressure during post-exercise ischaemia to pre-exercise levels. Sweat rate was monitored over two microdialysis membranes placed in the dermal space of forearm skin. One membrane was perfused with the acetylcholinesterase inhibitor neostigmine, while the other was perfused with the vehicle. 3. In normothermia, IHG exercise increased sweat rate at the neostigmine-treated site but not at the control site. Sweat rate remained elevated during post-exercise ischaemia even after mean arterial blood pressure returned to the pre-IHG exercise baseline. Subsequent removal of the ischaemia stimulus returned sweat rate to pre-IHG exercise levels. Sweat rate during post-exercise ischaemia without sodium nitroprusside administration followed a similar pattern. 4. During whole-body heating, IHG exercise increased sweat rate at both neostigmine-treated and untreated sites. Similarly, regardless of whether mean arterial blood pressure remained elevated or was reduced during post-exercise ischaemia, sweat rate remained elevated during the ischaemic period. 5. These results suggest that sweating in non-glabrous skin during post-IHG exercise ischaemia is activated by metaboreflex stimulation and not via baroreceptor loading.
This report reviews the scientific literature regarding the human system risks to the microgravity environment of space flight in relation to human performance. The primary human performance-related risks involve deconditioning of the cardiovascular and skeletal muscles systems due to prolonged exposure to the reduced gravitational input. The chronological history of U.S. space flight is reviewed as a starting point to inform and understand the gaps in the knowledge to these risks. Maintenance of physical performance capabilities involves understanding the health of many organ systems (peripheral [vascular, heart, blood volume, skeletal muscle] and central [brain]) that ultimately contribute to the submaximal and maximal capacity of the aerobic (VO2peak), skeletal muscle (strength and endurance) systems. Maintaining astronaut VO2peak, muscle mass, strength, and endurance before, during, and after space flight is a significant priority to NASA for the current International Space Station (ISS) era, as well as for future exploration missions. A growing research database from both space flight and ground-based analog studies finds that the cardiorespiratory system is compromised and skeletal muscles (predominantly postural muscles of the lower limbs) undergo atrophy. These structural and metabolic responses to living in microgravity conditions contribute to physiological deconditioning during space flight that potentially increase the risks to astronauts returning to surface operations (i.e., Moon, Mars, or Earth). The time course changes from short to long-duration space flight and the relationships between in-flight performance deconditioning levels are not well characterized. Moreover, there are large interindividual variabilities that may be dependent on genetics, age, sex, preflight fitness levels, and individual exercise prescriptions that need further careful evaluations. Efforts should be made to understand the current status of preflight, in-flight, and postflight exercise performance capability and to define the operational goals and target areas for protection with the in-flight exercise program. There is a bi-directional relationship between exercise prescription and hardware countermeasures that need further understanding in-flight. For example, hardware with limited capabilities/modalities may be counterbalanced by changes in exercise prescription (i.e., frequency, time, intensity, volume) for providing effective responses to maintain fitness. Importantly, the minimal requirements for exercise prescription on ISS hardware may not translate to lower capability hardware on exploration missions. Due to limited volume on exploration vehicles, future Artemis missions to the Lunar surface will not have similar exercise hardware capabilities as ISS. This may alter the effectiveness of hardware to provide adequate physiological stress on bodily systems allowing for adaptations to maintain aerobic capacity, strength, and bone density. Thus, it will be important to understand the exercise responses of current ISS countermeasures to develop individualized exercise prescriptions that minimize aerobic and muscular risks, accounting for the large variability of responses among crewmembers. Newer exploration exercise hardware is currently being evaluated that is more compact (i.e., E4D and Orion Flywheel) and will require careful evaluation of the hardware on the stressor (i.e., metabolic rate, oxygen uptake, and heart rate work relationships, and force plate load profiles) needed the human body to protect and maintain crew health and performance. Moreover, exercise responses on the hardware need careful evaluation on the chronic adaptations. Lastly, in-flight evaluation of hardware exercise response may differ in 0-g or partial-g compared to 1-g. Therefore, it cannot be assumed that the stress on the body will be the same in each environment. Understanding this has a direct impact on exercise prescriptions. This document provides an overview of key scientific investigations that have been conducted before, during, and after human space flight missions, as well as from human ground-based analog studies that contribute to the evidence base on changes in aerobic capacity and muscle mass, strength, and endurance. Additional data from rodent and nonhuman primate experiments of skeletal muscle unloading completed during space flight or ground-based flight-simulations provide supportive information about this risk topic. Most importantly, a recent, large dataset from long-duration ISS crew has been added to give improved insight into the variability of exercise response of crew, demonstrating that a large portion of the crew population return to Earth with greater than 10-20% loss of aerobic capacity and muscle strength and endurance. Data from human space flight and ground-based studies are narrowing in on the required exercise paradigms but thus far still provide an incomplete answer to an effective approach for maintaining skeletal muscle function and aerobic fitness of all human space travelers. Finally, the relationship of this risk topic to various space flight operational scenarios is examined and discussed.
PURPOSE: Isometric handgrip exercise in hyperthermia has been shown to reduce cutaneous vascular conductance (CVC) by inhibiting the cutaneous active vasodilator system. METHODS: To identify whether this response was initiated by muscle metaboreceptors, in seven subjects two 3-min bouts of isometric handgrip exercise in hyperthermia were performed, followed by 2 min of postexercise ischemia (PEI). An index of forearm skin blood flow (laser-Doppler flowmetry) was measured on the contralateral arm at an unblocked site and at a site at which adrenergic vasoconstrictor function was blocked via bretylium iontophoresis to reveal active cutaneous vasodilator function unambiguously. Sweat rate was measured via capacitance hygrometry, CVC was indexed from the ratio of skin blood flow to mean arterial pressure and was expressed as a percentage of maximal CVC at that site. In normothermia, neither isometric exercise nor PEI affected CVC (P > 0.05). RESULTS: The first bout of isometric handgrip exercise in hyperthermia reduced CVC at control sites and this reduction persisted through PEI (pre-exercise: 59.8 +/- 5.4, exercise: 49.8 +/- 4.9, PEI: 49.7 +/- 5.3% of maximum; both P < 0.05), whereas there were no significant changes in CVC at the bretylium treated sites. The succeeding bout of isometric exercise in hyperthermia significantly reduced CVC at both untreated (pre-exercise: 59.0 +/- 4.8, exercise: 47.3 +/- 4.0, PEI: 50.1 +/- 4.1% of maximum; both P < 0.05) and bretylium treated sites (pre-exercise: 61.4 +/- 7.3, exercise: 50.6 +/- 5.1, PEI: 53.9 +/- 6.0% of maximum, both P < 0.05). At both sites, CVC during PEI was lower than during the pre-exercise period (P < 0.05). Sweat rate rose significantly during both bouts of isometric exercise and remained elevated during PEI. CONCLUSIONS: These data suggest that the reduction in CVC during isometric exercise in hyperthermia, including the inhibition of the active vasodilator system, is primarily mediated by muscle metaboreceptors, whereas central command or muscle mechanoreceptors have less influence.
Long-term bed rest (BR), a model of spaceflight, results in a decrease in aerobic capacity and altered submaximal exercise responses. The strongest BR-induced effects on exercise appear to be centrally-mediated, but longer BR durations may result in peripheral adaptations (e.g., decreased mitochondrial and capillary density) which are likely to influence exercise responses. PURPOSE: To measure tissue oxygen saturation (SO2) and hydrogen ion concentration ([H+]) in the vastus lateralis (VL) using near infrared spectroscopy (NIRS) during cycle ergometry before and after . 30 d of BR. METHODS: Eight subjects performed a graded exercise test on a cycle ergometer to volitional fatigue 7 d before (pre-BR) and at the end or 1 day after BR (post-BR). NIRS spectra were collected from a sensor adhered to the skin overlying the VL. Oxygen consumption (VO2) was measured by open circuit spirometry. Blood volume (BV) was measured before and after BR using the carbon monoxide rebreathing technique. Changes in pre- and post-BR SO2 and [H+] data were compared using mixed model analyses. BV and peak exercise data were compared using paired t-tests. RESULTS: BV (pre-BR: 4.3+/-0.3, post-BR: 3.7+/-0.2 L, mean+/-SE, p=.01) and peak VO2 (pre-BR: 1.98+/-0.24, post-BR: 1.48 +/-0.21 L/min, p<.01) were reduced after BR. As expected, SO2 decreased with exercise before and after BR. However, SO2 was lower post compared with pre-BR throughout exercise, including at peak exercise (pre-BR: 50+/-3, post-BR: 43+/-4%, p=.01). After BR, [H+] was higher at the start of exercise and did not increase at the same rate as pre-BR. Peak [H+] was not different from pre to post-BR (pre-BR: 36+/-2; post-BR: 38+/-2 nmol/L). CONCLUSIONS: Lower SO2 during exercise suggests that oxygen extraction in the VL is higher after BR, perhaps due to lower circulating blood volume. The higher [H+] after BR suggests a greater reliance upon glycolysis during submaximal exercise, although [H+] at peak exercise was unchanged. Taken together, these data suggest that longer duration BR induces a number of changes that result in peripheral adaptations which contribute to cardiovascular and muscular deconditioning as measured by NIRS-derived SO2 and [H+] in the VL and may contribute to lower post-BR exercise tolerance. Supported by the National Space Biomedical Research Institute through NASA NCC 9-58
The in-flight exercise test performed by cosmonauts as part of the Russian Exercise Countermeasure Program is limited to 5 minutes due to communication restrictions. During a recent graded exercise test on a U.S. Shuttle flight, the test was terminated early due to an upcoming loss of signal (LOS) with the ground. This exercise test was a traditional test where the subject's exercise capacity dictates the length of the test. For example, one crew member may take 15 minutes to complete the test, while another may take 18 minutes. The traditional exercise test limits the flight schedulers to large blocks of space flight time in order to provide medical and research personnel information on the fitness capacity (maximal oxygen uptake: VO2max) of crew members during flight. A graded exercise test that would take a finite amount of time and a set preparation and recovery time would ease this problem by allowing flight schedulers to plan exercise tests in advance of LOS. The Graded Universal Testing System (GUTS) was designed to meet this goal. Fitness testing of astronauts before and after flight provides pertinent data on many variables. The Detailed Supplemental Objective (DSO608) protocol (6) is one of the graded exercise tests (GXT) currently used in astronaut testing before and after flight. Test times for this protocol have lasted from 11 to 18 minutes. Anaerobic capacity is an important variable that is currently not being evaluated before and after flight. Recent reports (1,2,5) from the literature have suggested that the oxygen deficit at supramaximal exercise is a measure of anaerobic capacity. We postulated that the oxygen deficit at maximal exercise would be an indication of anaerobic capacity. If this postulate can be accepted, then the efficiency of acquiring data from a graded exercise test would increase at least twofold. To examine this hypothesis anaerobic capacity was measured using a modified treadmill test (3,4) designed to exhaust the anaerobic systems in approximately 45 to 75 seconds. Lactate concentration in the blood was analyzed after all tests, since lactate is the end-product of anaerobic energy production. Therefore, the peak lactate response is an additional indication of anaerobic capacity. A preliminary comparison of the GUTS and the DSO608 suggests that the GUTS protocol would increase the efficiency of VO2max testing of astronauts before and after flight. Results for anaerobic capacity have not been tabulated.
Bed rest is an analog to spaceflight and advancement of exercise countermeasures is dependent on the development of exercise equipment that closely mimic actual upright exercise. The Horizontal Squat Device (HSD) was developed to allow a supine exerciser to perform squats that mimic upright squat exercise. PURPOSE: To compare vertical ground reaction force (GRFv) on the HSD with Free Weight (FW) or Smith Machine (SM) during squat exercise. METHODS: Subjects (3F, 3M) performed sets of squat exercise with increasing loads up to 1-repetition (rep) maximum. GRF data were collected and compared with previous GRF data for squat exercise performed with FW & SM. Loads on the HSD were adjusted to magnitudes comparable with FW & SM by subtracting the subject s body weight (BW). Peak GRFv for 45-, 55-, 64-, & 73-kg loads above BW were calculated. Percent (%) difference between HSD and the two upright conditions were computed. Effect size was calculated for the 45-kg load. RESULTS: Most subjects were unable to lift >45 kg on the HSD; however, 1 subject completed all loads. Anecdotal evidence suggested that most subjects shoulders or back failed before their legs. The mean % difference are shown. In the 45-kg condition, effect sizes were 0.37 & 0.83 (p>0.05) for HSD vs. FW and HSD vs. SM, respectively, indicating no differences between exercise modes. CONCLUSION: When BW was added to the target load, results indicated that vertical forces were similar to those in FW and SM exercise. The exercise prescription for the HSD should include a total external resistance equivalent to goal load plus subject BW. The HSD may be used as an analog to upright exercise in bed rest studies, but because most subjects were unable to lift >45 kg, it may be necessary to prescribe higher reps and lower loads to better target the leg musculature
Musculoskeletal activity has the potential to both improve and compromise decompression safety. Exercise enhances inert gas elimination during oxygen breathing prior to decompression (prebreathe), but it may also promote bubble nuclei formation (nucleation), which can lead to gas phase separation and bubble growth and increase the risk of decompression sickness (DCS). The timing, pattern and intensity of musculoskeletal activity and the level of tissue supersaturation may be critical to the net effect. Understanding the relationships is important to evaluate exercise prebreathe protocols and quantify decompression risk in gravity and microgravity environments. Data gathered during NASA's Prebreathe Reduction Program (PRP) studies combined oxygen prebreathe and exercise followed by low pressure (4.3 psi; altitude equivalent of 30,300 ft [9,235 m]) microgravity simulation to produce two protocols used by astronauts preparing for extravehicular activity. Both the Phase II/CEVIS (cycle ergometer vibration isolation system) and ISLE (in-suit light exercise) trials eliminated ambulation to more closely simulate the microgravity environment. The CEVIS results (35 male, 10 female) serve as control data for this NASA/Duke study to investigate the influence of ambulation exercise on bubble formation and the subsequent risk of DCS. METHODS Four experiments will replicate the CEVIS exercise-enhanced oxygen prebreathe protocol, each with a different exception. The first of these is currently underway. Experiment 1 - Subjects complete controlled ambulation (walking in place with fixed cadence and step height) during both preflight and at 4.3 psi instead of remaining nonambulatory throughout. Experiment 2 - Subjects remain non-ambulatory during the preflight period and ambulatory at 4.3 psi. Experiment 3 - Subjects ambulate during the preflight period and remain non-ambulatory at 4.3 psi. Experiment 4 - The order of heavy and light exercise employed in the CEVIS protocol is reversed, with the light exercise occurring first (subjects remain non-ambulatory throughout). Decompression stress is assessed with non-invasive ultrasound during each of 14 epochs of a 4 hour simulated spacewalk at 4.3 psi; aural Doppler is used to monitor bubbles (Spencer grade 0-IV scale) passing through the pulmonary artery, and two-dimensional echocardiographic imaging is used to look for left ventricular gas emboli (LVGE; the presence of which is a test termination criterion). Venous blood is collected at baseline and twice following repressurization to determine if the decompression stress is correlated with microparticles (cell fragments) accumulation. The plan is to test 25-50 subjects in each experiment. Fisher Exact Tests (one-tailed) are used to compare test and control groups. Trials are suspended when the DCS or grade IV VGE observations reach 70% confidence of DCS risk >15% and grade IV VGE risk >20%. RESULTS Experiment 1 was concluded with 20 complete trials (15 male, 5 female) since the statistical outcome would not change with five additional trials. The observed DCS was significantly greater in Experiment 1 than in CEVIS trials (4/20 [20%] vs. 0/45 [0%], respectively, p=0.007), as was the frequency of peak grade IV VGE (6/21 [29%; including one additional subject that presented grade IV VGE but whose trial was ended before completion when LVGE were observed] vs. 3/45 [7%], respectively, p=0.024). Experiment 3 trials are now underway, with 11 trials completed (10 male, 1 female). Preliminary results indicate no difference in observed DCS between Experiment 3 and CEVIS trials (1/11 [9%] vs. 0/45 [0%], respectively, p=0.196), or between Experiment 3 and Experiment 1 trials (p=0.405). The frequency of peak grade IV VGE in Experiment 3 (2/11 [18%]) did not differ from CEVIS or Experiment 1 trials (p=0.251 and p=0.425, respectively). Microparticle patterns are widely variable and still under analysis. DISCUSSION The results of the Experiment 1 trials support the thesis that decompression stress is increased by ambulation exercise, given the higher incidence of DCS and grade IV VGE when compared to the non-ambulatory PRP CEVIS trials. Experiment 3 trials are incomplete, but suggest that the effect of ambulation during ground level preflight oxygen breathing alone, when subjects are undersaturated with inert gas, may not differ in risk from ambulation at both preflight and spacesuit pressures, the latter when subjects are supersaturated with inert gas. Further trials are needed to confirm the relative effects of ambulation in undersaturated vs. supersaturated states and to determine whether light exercise facilitates the removal of heavy exercise-induced nucleation (Experiment 4).