Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

DETECTION OF GAMMA-RAY POLARIZATION IN PROMPT EMISSION OF GRB 100826A

We report the polarization measurement in prompt {gamma}-ray emission of GRB 100826A with the Gamma-Ray Burst Polarimeter on board the small solar-power-sail demonstrator IKAROS. We detected the firm change of polarization angle (PA) during the prompt emission with 99.9% (3.5{sigma}) confidence level, and the average polarization degree ({Pi}) of 27% {+-} 11% with 99.4% (2.9{sigma}) confidence level. Here the quoted errors are given at 1{sigma} confidence level for the two parameters of interest. The systematic errors have been carefully included in this analysis, unlike other previous reports. Such a high {Pi} can be obtained in several emission models of gamma-ray bursts (GRBs), including synchrotron and photospheric models. However, it is difficult to explain the observed significant change of PA within the framework of axisymmetric jet as considered in many theoretical works. The non-axisymmetric (e.g., patchy) structures of the magnetic fields and/or brightness inside the relativistic jet are therefore required within the observable angular scale of {approx}{Gamma}{sup -1}. Our observation strongly indicates that the polarization measurement is a powerful tool to constrain the GRB production mechanism, and more theoretical works are needed to discuss the data in more detail.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Integrated Vapor Transport Biases

Abstract High-fidelity analyses and forecasts of integrated vapor transport (VT) are central to the study of Earth’s hydrological cycle as well as high-impact phenomena such as monsoons and atmospheric rivers. The impact of the in-line analysis correction-based additive inflation (ACAI) on IVT biases and forecast errors is examined within the Navy Earth System Prediction Capability (Navy ESPC) global coupled system. The ACAI technique uses atmospheric analysis corrections from the data assimilation system to approximate model bias and as a representation of stochastic model error to simultaneously reduce systematic and random errors and improve ensemble performance. ACAI reduces the global average magnitude of the 7- and 14-day IVT bias by 16%–17% during Northern Hemisphere summer, reaching 70% reductions in some tropical regions. The global average IVT bias reduction is similar to the bias reduction for low-level wind speed bias and considerably smaller than the bias reduction in total precipitable water. The localized regions where ACAI increases IVT bias occur where the control IVT biases change sign and structure with increasing forecast lead time, such as the South Asian monsoon region. Substituting analyzed wind or moisture fields for the forecast fields when calculating the forecast IVT confirms that, on average, wind errors dominate the IVT error calculation in the tropics, although wind and moisture error contributions are comparable in the extratropics. The existence of regions where using either analyzed winds or analyzed moisture increases IVT bias or mean absolute error reveals areas with compensating errors.

Reynolds, Carolyn A.↗

Use of treatment log files in spot scanning proton therapy as part of patient-specific quality assurance

Purpose: The purpose of this work was to assess the monitor unit (MU) values and position accuracy of spot scanning proton beams as recorded by the daily treatment logs of the treatment control system, and furthermore establish the feasibility of using the delivered spot positions and MU values to calculate and evaluate delivered doses to patients. Methods: To validate the accuracy of the recorded spot positions, the authors generated and executed a test treatment plan containing nine spot positions, to which the authors delivered ten MU each. The spot positions were measured with radiographic films and Matrixx 2D ion-chambers array placed at the isocenter plane and compared for displacements from the planned and recorded positions. Treatment logs for 14 patients were then used to determine the spot MU values and position accuracy of the scanning proton beam delivery system. Univariate analysis was used to detect any systematic error or large variation between patients, treatment dates, proton energies, gantry angles, and planned spot positions. The recorded patient spot positions and MU values were then used to replace the spot positions and MU values in the plan, and the treatment planning system was used to calculate the delivered doses to patients. The results were compared with the treatment plan. Results: Within a treatment session, spot positions were reproducible within {+-}0.2 mm. The spot positions measured by film agreed with the planned positions within {+-}1 mm and with the recorded positions within {+-}0.5 mm. The maximum day-to-day variation for any given spot position was within {+-}1 mm. For all 14 patients, with {approx}1 500 000 spots recorded, the total MU accuracy was within 0.1% of the planned MU values, the mean (x, y) spot displacement from the planned value was (-0.03 mm, -0.01 mm), the maximum (x, y) displacement was (1.68 mm, 2.27 mm), and the (x, y) standard deviation was (0.26 mm, 0.42 mm). The maximum dose difference between calculated dose to the patient based on the plan and recorded data was within 2%. Conclusions: The authors have shown that the treatment log file in a spot scanning proton beam delivery system is precise enough to serve as a quality assurance tool to monitor variation in spot position and MU value, as well as the delivered dose uncertainty from the treatment delivery system. The analysis tool developed here could be useful for assessing spot position uncertainty and thus dose uncertainty for any patient receiving spot scanning proton beam therapy.

60 APPLIED LIFE SCIENCES↗

Building a Wide-Area File Transfer Performance Predictor: An Empirical Study

Wide-area data transfer is central to geographically distributed scientific workflows. Faster delivery of data is important for these workflows. Predictability is equally (or even more) important. With the goal of providing a reasonably accurate estimate of data transfer time to improve resource allocation & scheduling for workflows and enable end-to-end data transfer optimization, we apply machine learning methods to develop predictive models for data transfer times over a variety of wide area networks. To build and evaluate these models, we use 201,388 transfers, involving 759 million files totaling 9 PB transferred, over 115 heavily used source-destination pairs (“edges”) between 135 unique endpoints. We evaluate the models for different retraining frequencies and different window size of history data. In the best case, the resulting models have a median prediction error of ≤21% for 50% of the edges, and ≤32% for 75% of the edges. We present a detailed analysis of these results that provides insights into the cause of some of the high errors. We envision that the performance predictor will be informative for scheduling geo-distributed workflows. The insights also suggest obvious directions for both further analysis and transfer service optimization.

Liu, Zhengchun↗

Improving cosmological analyses of HI clustering by reducing stochastic noise

High-number-density tracers of large-scale structure, such as the HI-rich galaxies measured by 21 cm intensity mapping, have low sampling noise, making them particularly promising as cosmological probes. At large scales, this sampling noise can be subdominant to other scale-independent contributions to the power spectrum; such contributions arise from nonlinear bias, and exceed the sampling noise if at least one of the associated bias coefficients is sufficiently large. This has important consequences for cosmological constraints obtained from such tracers, since it indicates that using the power spectrum does not lead to optimal constraints even in the linear regime. In this paper, we provide a conservative estimate of the possible improvement in constraining power of a 21 cm survey if one were to use an optimal analysis strategy (such as field-level analysis), where only the true sampling noise enters the error budget. We find that improvements in uncertainties on some cosmological parameters can be as large as 50%, depending on redshift, foreground cleaning efficiency, scales used in the analysis, and instrumental noise. One byproduct of our work is measurements of bias parameters and stochasticity for neutral hydrogen in the IllustrisTNG simulation over a wide range of redshifts; we provide simple fitting formulas for these measurements. Furthermore, our results motivate further exploration of new optimal analysis techniques and provide important insights into the constraining power of current and future 21 cm surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

A SIMULTANEOUS STACKING AND DEBLENDING ALGORITHM FOR ASTRONOMICAL IMAGES

Stacking analysis is a means of detecting faint sources using a priori position information to estimate an aggregate signal from individually undetected objects. Confusion severely limits the effectiveness of stacking in deep surveys with limited angular resolution, particularly at far-infrared to submillimeter wavelengths, and causes a bias in stacking results. Deblending corrects measured fluxes for confusion from adjacent sources; however, we find that standard deblending methods only reduce the bias by roughly a factor of 2 while tripling the variance. We present an improved algorithm for simultaneous stacking and deblending that greatly reduces bias in the flux estimate with nearly minimum variance. When confusion from neighboring sources is the dominant error, our method improves upon rms error by at least a factor of 3 and as much as an order of magnitude compared to other algorithms. This improvement will be useful for Herschel and other telescopes working in a source confused, low signal-to-noise regime.

79 ASTRONOMY AND ASTROPHYSICS↗

CHARACTERIZATION OF THE BICEP TELESCOPE FOR HIGH-PRECISION COSMIC MICROWAVE BACKGROUND POLARIMETRY

The Background Imaging of Cosmic Extragalactic Polarization (BICEP) experiment was designed specifically to search for the signature of inflationary gravitational waves in the polarization of the cosmic microwave background (CMB). Using a novel small-aperture refractor and 49 pairs of polarization-sensitive bolometers, BICEP has completed three years of successful observations at the South Pole beginning in 2006 February. To constrain the amplitude of the inflationary B-mode polarization, which is expected to be at least 7 orders of magnitude fainter than the 3 K CMB intensity, precise control of systematic effects is essential. This paper describes the characterization of potential systematic errors for the BICEP experiment, supplementing a companion paper on the initial cosmological results. Using the analysis pipelines for the experiment, we have simulated the impact of systematic errors on the B-mode polarization measurement. Guided by these simulations, we have established benchmarks for the characterization of critical instrumental properties including bolometer relative gains, beam mismatch, polarization orientation, telescope pointing, sidelobes, thermal stability, and timestream noise model. A comparison of the benchmarks with the measured values shows that we have characterized the instrument adequately to ensure that systematic errors do not limit BICEP's two-year results, and identifies which future refinements are likely necessary to probe inflationary B-mode polarization down to levels below a tensor-to-scalar ratio r = 0.1.

79 ASTRONOMY AND ASTROPHYSICS↗

Validation and Generalization of a Method for Precise Size Measurements of Metal Nanoclusters on Supports

We recently described a data analysis method for precise ({approx}0.1 {angstrom} random error in the mean for a 200 kV instrument with a 3 {angstrom} FWHM probe size) size measurements of small clusters of heavy metal atoms on supports as imaged in a scanning transmission electron microscope, including an experimental demonstration using clusters that were primarily triosmium or decaosmium. The method is intended for low signal-to-noise ratio images of radiation-sensitive samples. We now present a detailed analysis, including a generalization to address issues of particle anisotropy and biased orientation distributions. In the future, this analysis should enable extraction of shape as well as size information, up to the noise-defined limit of information present in the image. We also present results from an extensive series of simulations designed to determine the method's range of applicability and expected performance in realistic situations. The simulations reproduce the experiments quite accurately, enabling a correction of systematic errors so that only the {approx}0.1 {angstrom} random error remains. The results are very stable over a wide range of parameters. We introduce a variation on the method with improved precision and stability relative to the original version, while also showing how simple diagnostics can test whether the results are reliable in any particular instance.

36 MATERIALS SCIENCE↗

ON THE ACCURACY OF THE DIFFERENTIAL EMISSION MEASURE DIAGNOSTICS OF SOLAR PLASMAS. APPLICATION TO SDO/AIA. II. MULTITHERMAL PLASMAS

Differential emission measure (DEM) analysis is one of the most used diagnostic tools for solar and stellar coronae. Being an inverse problem, it has limitations due to the presence of random and systematic errors. We present in this series of papers an analysis of the robustness of the inversion in the case of SDO/AIA observations. We completely characterize the DEM inversion and its statistical properties, providing all the solutions consistent with the data along with their associated probabilities, and a test of the suitability of the assumed DEM model. While Paper I focused on isothermal conditions, we now consider multithermal plasmas and investigate both isothermal and multithermal solutions. We demonstrate how the ambiguity between noises and multithermality fundamentally limits the temperature resolution of the inversion. We show that if the observed plasma is multithermal, isothermal solutions tend to cluster on a constant temperature whatever the number of passbands or spectral lines. The multithermal solutions are also found to be biased toward near-isothermal solutions around 1 MK. This is true even if the residuals support the chosen DEM model, possibly leading to erroneous conclusions on the observed plasma. We propose tools for identifying and quantifying the possible degeneracy of solutions, thus helping the interpretation of DEM inversion.

79 ASTRONOMY AND ASTROPHYSICS↗

BEYONDPLANCK XIII. Intensity foreground sampling, degeneracies, and priors

We present the intensity foreground algorithms and model employed within the BEYONDPLANCK analysis framework. The BEYONDPLANCK analysis is aimed at integrating component separation and instrumental parameter sampling within a global framework, leading to complete end-to-end error propagation in the Planck Low Frequency Instrument (LFI) data analysis. Given the scope of the BEYONDPLANCK analysis, a limited set of data is included in the component separation process, leading to foreground parameter degeneracies. In order to properly constrain the Galactic foreground parameters, we improve upon the previous Commander component separation implementation by adding a suite of algorithmic techniques. These algorithms are designed to improve the stability and computational efficiency for weakly constrained posterior distributions. These are: (1) joint foreground spectral parameter and amplitude sampling, building on ideas from MIRAMARE; (2) component-based monopole determination; (3) joint spectral parameter and monopole sampling; and (4) application of informative spatial priors for component amplitude maps. We find that the only spectral parameter with a significant signal-to-noise ratio using the current BEYONDPLANCK data set is the peak frequency of the anomalous microwave emission component, for which we find $ν$ p = 25.3 ± 0.5 GHz; all others must be constrained through external priors. Future works will be aimed at integrating many more data sets into this analysis, both map and time-ordered based, thereby gradually eliminating the currently observed degeneracies in a controlled manner with respect to both instrumental systematic effects and astrophysical degeneracies. When this happens, the simple LFI-oriented data model employed in the current work will need to be generalized to account for both a richer astrophysical model and additional instrumental effects. This work will be organized within the Open Science-based COSMOGLOBE community effort.

79 ASTRONOMY AND ASTROPHYSICS↗

Silicon Carbide Temperature Monitor Processing Improvements. Status Report

Silicon carbide (SiC) temperature monitors are used as temperature sensors in Advanced Test Reactor (ATR) irradiations at the Idaho National Laboratory (INL). Although thermocouples are typically used to provide real-time temperature indication in instrumented lead tests, other indicators, such as melt wires, are also often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires as a post-irradiation technique for peak temperature indication. Melt wires are limited in that they can only detect whether a single temperature is or is not exceeded. SiC monitors are advantageous because a single monitor can be used to detect for a range of temperatures that occurred during irradiation. As part of the process initiated to make SiC temperature monitors available at the ATR, post-irradiation evaluations of these monitors have been previously completed at the High Temperature Test Laboratory (HTTL). INL selected the resistance measurement approach for determining irradiation temperature from SiC temperature monitors because it is considered to be the most accurate measurement. The current process involves the repeated annealing of the SiC monitors at incrementally increasing temperature, with resistivity measurements made between annealing steps. The process is time consuming and requires the nearly constant attention of a trained staff member. In addition to the expensive and lengthy post analysis required, the current process adds many potential sources of error in the measurement, as the sensor must be repeatedly moved from furnace to test fixture. This time-consuming post irradiation analysis is a significant portion of the total cost of using these otherwise inexpensive sensors. An additional consideration of this research is that, if the SiC post processing can be automated, it could be performed in an MFC hot cell, further reducing the time and expense of lengthy decontaminations prior to processing. Sections of this report provide a general description of resistivity techniques currently used to infer peak irradiation temperature from silicon carbide temperature monitors along with some representative data, the proposed concepts to improve the process of analyzing irradiated SiC temperature monitors, the completed efforts to prove the proposed concepts, and future activities. The efforts detailed here succeeded in designing and developing a real-time automated SiC resistivity measurement system, and performed two initial test runs. Activities carried out include the assembly and integration of the system hardware; the design and development of a preliminary monitor fixture; the design of a technique to automate the data analysis and processing; the development of the communication, coordination, and user software; and the execution and troubleshooting of test run experiments using the box furnace. Although the automation system performed as required, the designed fixture did not succeed in establishing the needed electrical contacts with the SiC monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LOGISTIC FUNCTION PROFILE FIT: A least-squares program for fitting interface profiles to an extended logistic function

The extended logistic function provides a physically reasonable description of interfaces such as depth profiles or line scans of surface topological or compositional features. It describes these interfaces with the minimum number of parameters, namely, position, width, and asymmetry. Logistic Function Profile Fit (LFPF) is a robust, least-squares fitting program in which the nonlinear extended logistic function is linearized by a Taylor series expansion (equivalent to a Newton-Raphson approach) with no apparent introduction of bias in the analysis. The program provides reliable confidence limits for the parameters when systematic errors are minimal and provides a display of the residuals from the fit for the detection of systematic errors. The program will aid researchers in applying ASTM E1636-10, 'Standard practice for analytically describing sputter-depth-profile and linescan-profile data by an extended logistic function,' and may also prove useful in applying ISO 18516: 2006, 'Surface chemical analysis-Auger electron spectroscopy and x-ray photoelectron spectroscopy-determination of lateral resolution.' Examples are given of LFPF fits to a secondary ion mass spectrometry depth profile, an Auger surface line scan, and synthetic data generated to exhibit known systematic errors for examining the significance of such errors to the extrapolation of partial profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of shockless dynamic compression data on solids to multi-megabar pressures: Application to tantalum

Magnetically-driven, planar shockless-compression experiments to multi-megabar pressures were performed on tantalum samples using a stripline target geometry. Free-surface velocity waveforms were measured in 15 cases; nine of these in a dual-sample configuration with two samples of different thicknesses on opposing electrodes, and six in a single-sample configuration with a bare electrode opposite the sample. Details are given on the application of inverse Lagrangian analysis (ILA) to these data, including potential sources of error. The most significant source of systematic error, particularly for single-sample experiments, was found to arise from the pulse-shape dependent free-surface reflected wave interactions with the deviatoric-stress response of tantalum. This could cause local, possibly temporary, unloading of material from a ramp compressed state, and thus multi-value response in wave speed that invalidates the free-surface to in-material velocity mapping step of ILA. By averaging all 15 data sets, a final result for the principal quasi-isentrope of tantalum in stress-strain was obtained to a peak longitudinal stress of 330 GPa with conservative uncertainty bounds of ±4.5% in stress. The result agrees well with a tabular equation of state developed at Los Alamos National Laboratory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase-based velocity extraction method for photonic Doppler velocimetry with potential higher time resolution

We present an extension of the [Takeda et al., J. Opt. Soc. Am. 72, 156 (1982)] phase extraction method to heterodyne photonic Doppler velocimetry applications. The method yields results equivalent to those obtained by the short-time Fourier transform (STFT), while offering potential improvements in time resolution. Unlike STFT, which relies on window functions, such as the Hamming window, that emphasize central data points and diminish the influence of edges, the extended Takeda method utilizes all data uniformly. This uniform treatment allows for the derivation of empirical equations that directly relate velocity error to the actual time resolution rather than to the local analysis duration. The established equation provides a useful metric for both optimizing hardware configuration and guiding data analysis. Simulation and experimental results confirm that, for a given dataset, specifying a target time resolution yields consistent velocity errors for both methods. These findings underscore the Takeda method’s advantages, particularly its potential higher time resolution and reduced computational burden, making it a valuable tool for high-throughput applications such as laser dynamic compression experiments.

Computer simulation↗

Economic optimization of operations for hybrid energy systems under variable markets

We prosed a hybrid energy systems (HES) which is an important element to enable increasing penetration of clean energy. Our paper investigates the operations flexibility of HES, and develops a methodology for operations optimization for maximizing economic value based on predicted renewable generation and market information. A multi-environment computational platform for performing such operations optimization is also developed. In order to compensate for prediction error, a control strategy is accordingly designed to operate a standby energy storage element (ESE) to avoid energy imbalance within HES. The proposed operations optimizer allows systematic control of energy conversion for maximal economic value. Simulation results of two specific HES configurations are included to illustrate the proposed methodology and computational capability. These results demonstrate the economic viability of HES under proposed operations optimizer, suggesting the diversion of energy for alternative energy output while participating in the ancillary service market. Economic advantages of such operations optimizer and associated flexible operations are illustrated by comparing the economic performance of flexible operations against that of constant operations. Sensitivity analysis with respect to market variability and prediction error, are also performed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reduced discretization error in HZETRN

The deterministic particle transport code HZETRN is an efficient analysis tool for studying the effects of space radiation on humans, electronics, and shielding materials. In a previous work, numerical methods in the code were reviewed, and new methods were developed that further improved efficiency and reduced overall discretization error. It was also shown that the remaining discretization error could be attributed to low energy light ions (A < 4) with residual ranges smaller than the physical step-size taken by the code. Accurately resolving the spectrum of low energy light particles is important in assessing risk associated with astronaut radiation exposure. In this work, modifications to the light particle transport formalism are presented that accurately resolve the spectrum of low energy light ion target fragments. The modified formalism is shown to significantly reduce overall discretization error and allows a physical approximation to be removed. For typical step-sizes and energy grids used in HZETRN, discretization errors for the revised light particle transport algorithms are shown to be less than 4% for aluminum and water shielding thicknesses as large as 100 g/cm{sup 2} exposed to both solar particle event and galactic cosmic ray environments.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-88: Comprehensive Automated Daily QA for Hypo- Fractionated Treatments

Purpose: The trend towards more SBRT treatments with fewer high dose fractions places increased importance on daily QA. Patient plan specific QA with 3%/3mm gamma analysis and daily output constancy checks may not be enough to guarantee the level of accuracy required for SBRT treatments. But increasing the already extensive amount of QA procedures that are required is a daunting proposition. We performed a feasibility study for more comprehensive automated daily QA that could improve the diagnostic capabilities of QA without increasing workload. Methods: We performed the study on a Siemens Artiste linear accelerator using the integrated flat panel EPID. We included square fields, a picket fence, overlap and representative IMRT fields to measure output, flatness, symmetry, beam center, and percent difference from the standard. We also imposed a set of machine errors: MLC leaf position, machine output, and beam steering to compare with the standard. Results: Daily output was consistent within +/− 1%. Change in steering current by 1.4% and 2.4% resulted in a 3.2% and 6.3% change in flatness. 1 and 2mm MLC leaf offset errors were visibly obvious in difference plots, but passed a 3%/3mm gamma analysis. A simple test of transmission in a picket fence can catch a leaf offset error of a single leaf by 1mm. The entire morning QA sequence is performed in less than 30 minutes and images are automatically analyzed. Conclusion: Automated QA procedures could be used to provide more comprehensive information about the machine with less time and human involvement. We have also shown that other simple tests are better able to catch MLC leaf position errors than a 3%/3mm gamma analysis commonly used for IMRT and modulated arc treatments. Finally, this information could be used to watch trends of the machine and predict problems before they lead to costly machine downtime.

60 APPLIED LIFE SCIENCES↗