Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Immune Response to Electromagnetic Fields through Cybernetic Modeling

We study the optimality of the humoral immune response through a mathematical model, which involves the effect of electromagnetic fields over the large lymphocytes proliferation. Are used the so called cybernetic variables in the context of the matching law of microeconomics or mathematical psychology, to measure the large lymphocytes population and to maximize the instantaneous antibody production rate in time during the immunologic response in order to most efficiently inactivate the antigen.

60 APPLIED LIFE SCIENCES↗

Cherenkov-type diamond detectors for measurements of fast electrons in the TORE-SUPRA tokamak

The paper presents a schematic design and tests of a system applicable for measurements of fast electron pulses emitted from high-temperature plasma generated inside magnetic confinement fusion machines, and particularly in the TORE-SUPRA facility. The diagnostic system based on the registration of the Cherenkov radiation induced by fast electrons within selected solid radiators is considered, and electron low-energy thresholds for different radiators are given. There are some estimates of high thermal loads, which might be deposited by intense electron beams upon parts of the diagnostic equipment within the TORE-SUPRA device. There are some proposed measures to overcome this difficulty by the selection of appropriate absorption filters and Cherenkov radiators, and particularly by the application of a fast-moving reciprocating probe. The paper describes the measuring system, its tests, as well as some results of the preliminary measurements of fast electrons within TORE-SUPRA facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE PROPERTIES OF X-RAY LUMINOUS YOUNG STELLAR OBJECTS IN THE NGC 1333 AND SERPENS EMBEDDED CLUSTERS

We present new Chandra X-ray data of the NGC 1333 embedded cluster and combine these data with existing Chandra data, Spitzer photometry, and ground-based spectroscopy of both the NGC 1333 and Serpens cloud core clusters to perform a detailed study of the X-ray properties of two of the nearest embedded clusters to the Sun. We first present new, deeper observations of NGC 1333 with Chandra ACIS-I and combine these with existing Spitzer observations of the region. In NGC 1333, a total of 95 cluster members are detected in X-rays of which 54 were previously identified in the Spitzer data. Of the Spitzer-identified sources, we detected 23% of the Class I protostars, 53% of the flat-spectrum sources, 52% of the Class II, and 50% of the transition disk young stellar objects (YSOs). Forty-one Class III members of the cluster are identified, bringing the total identified YSO population to 178. The X-ray luminosity functions (XLFs) of the NGC 1333 and Serpens clusters are compared to each other and the Orion Nebula Cluster (ONC). Based on a comparison of the XLFs of the Serpens and NGC 1333 clusters to the previously published ONC, we obtain a new distance for the Serpens cluster of 360{sup +22}{sub -13} pc. Using our previously published spectral types, effective temperatures, and bolometric luminosities, we analyze the dependence of the X-ray emission on the measured stellar properties. The X-ray luminosity was found to depend on the calculated bolometric luminosity as in previous studies of other clusters. We examine the dependence of L{sub X} on stellar surface area and effective temperature, and find that L{sub X} depends primarily on the stellar surface area. In the NGC 1333 cluster, the Class III sources have a somewhat higher X-ray luminosity for a given surface area. We also find evidence in NGC 1333 for a jump in the X-ray luminosity between spectral types of M0 and K7, we speculate that this may result from the presence of radiative zones in the K-stars. The gas column density versus extinction in the NGC 1333 parental molecular cloud was examined using the hydrogen column density determined from the X-ray absorption to the embedded stars and the K-band extinction measured to those stars. In NGC 1333, we find N{sub H} = 0.89 {+-} 0.13 x 10{sup 22} A{sub K} , this is lower than expected of the standard interstellar medium but similar to that found previously in the Serpens cloud core.

79 ASTRONOMY AND ASTROPHYSICS↗

Increase of Acting Pressure by Adjusted Tool Geometry in Laser Shock Forming

In laser shock forming TEA-CO2{sub 2}-laser induced shock waves are used to form metal foils, such as aluminum or copper. The process utilizes an initiated plasma shock wave on the target surface, which leads to a forming of the foil. Several pulses can be applied at one point in order to achieve a high forming degree without increasing the energy density beyond the ablation limit. During the process, pressure peaks in the range of several MPa can be achieved. In this article, it will be demonstrated that the acting shock wave pressure can be increased and the forming behavior can be modified by an adjustment of tool geometry, which limits the non-directional propagation of the shock wave. Shock wave pressure measurements as well as forming results with different tool geometries show that the acting pressure, and therefore the forming behavior, can be modified by an adjustment of the tool.

36 MATERIALS SCIENCE↗

Anomalous photoresponse of GaN x-ray Schottky detectors

GaN based materials are believed to be very stable materials, in particular, under irradiation by high energy photons such as x rays. We have studied x-ray detectors based on GaN Schottky diodes. Vertical Schottky diodes were fabricated based on a 20 mum thick undoped GaN layer grown on a conductive GaN substrate. Their photoresponse to near UV light and to x rays was measured. While the response to near UV light was fast and linear as expected, anomalous behaviors were observed under x-ray illumination. The photocurrent increases as the third power of the incident x-ray flux. The photocurrent transient when the x rays is turned on are long and nonexponential (S shape) and strongly differs from the off transient which is fast and exponential. Also, a very strong quenching of the x-ray photoresponse is observed when the detector is simultaneously illuminated with visible light. All of these anomalous behaviors are explained in the frame of a complete model involving traps and tunnel currents. A reasonable quantitative agreement between the model and the experimental data is obtained.

36 MATERIALS SCIENCE↗

Area-selected Ion Milling for Reflection Wavefront Error Correction of Soft X-ray Multilayer Mirrors

For accurate reflection wavefront error correction of imaging soft X-ray multilayer mirrors, a period-by-period ion milling system was developed. A stable and homogenized radial distribution of ion beam was realized for an ion milling over a whole area of 100 mm-wide multilayer. To demonstrate the wavefront error correction principle, a dielectric multilayer mirror for visible light was locally milled by our system. Wavefront as measured by a phase shifting interferometer showed the reflection phase of local milling multilayer advanced. Area-selected ion millings with mask templates made of Mo and Si, and by photoresist contact masks were carried out. Although striped patterns generated by the difference of spectroscopic reflectance between Mo and Si were observed at peripherals of milling area when templates were used, a clear and sharp edge pattern was obtained with contact mask. Soft X-ray reflectance of a Mo/Si multilayer milled with photoresist contact mask showed good feasibility of precise wavefront error correction of multilayers. These results proved our phase correction method is promising and practical for the 0.1 nm-period correction of soft X-ray multilayer mirror.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of ITER divertor shunts as a synthetic diagnostic for detachment control

Reliable diagnostics that measure the detached state of the ITER divertor plasma will be necessary to control heat flux to the divertor targets during steady state, burning plasma operation. This paper conducts an initial exploration into the feasibility of the divertor shunt diagnostic as a lightweight, robust, and real-time detachment sensor. This diagnostic is a set of shunt lead pairs that measure the voltage drop along the divertor cassette body, from which the plasma scrape-off layer (SOL) current is calculated. Using SOLPS-ITER simulations for control-relevant ITER plasma scenarios, the thermoelectric current magnitude along the SOL is shown to decrease significantly with the onset of partial detachment at the outer divertor target. Electromagnetic modelling of a simplified divertor cassette is used to develop a control-oriented inductance-resistance circuit model, from which SOL currents can be calculated from shunt pair voltage measurements. The sensitivity and frequency-response of the resulting system indicates that the diagnostic will accurately measure SOL thermoelectric currents during ITER operation. These currents will be a good measure of the detached state of the divertor plasma, making the divertor shunt diagnostic a potentially extremely valuable and physically robust sensor for real-time detachment control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetically coupled pressure sensor

Measurement of pressure of a fluid in a vessel using a cantilever spring in the vessel; a magnet connected to the cantilever spring in the vessel; an electromagnet outside of the vessel operatively connected to the magnet and the cantilever spring in the vessel, wherein the electromagnet induces movement of the magnet and the cantilever spring in the vessel, and wherein the movement is related to the pressure of the fluid in the vessel; a receiving coil operatively positioned relative to the magnet, wherein movement of the cantilever spring and the magnet in the vessel creates an electromotive response in the coil; and a controller analyzer connected to the receiving coil, wherein the controller analyzer uses the electromotive response in the coil for measuring the pressure of the fluid in the vessel.

Kotovsky, Jack↗

Magnetically coupled pressure sensor

Measurement of pressure of a fluid in a vessel using a cantilever spring in the vessel; a magnet connected to the cantilever spring in the vessel; an electromagnet outside of the vessel operatively connected to the magnet and the cantilever spring in the vessel, wherein the electromagnet induces movement of the magnet and the cantilever spring in the vessel, and wherein the movement is related to the pressure of the fluid in the vessel; a receiving coil operatively positioned relative to the magnet, wherein movement of the cantilever spring and the magnet in the vessel creates an electromotive response in the coil; and a controller analyzer connected to the receiving coil, wherein the controller analyzer uses the electromotive response in the coil for measuring the pressure of the fluid in the vessel.

Kotovsky, Jack↗

A More Efficient, Radiation-Free Alternative to Systematic Chest X-Ray for the Detection of Embolized Seeds to the Lung

Purpose: To evaluate the efficacy of a seed-migration detector and to compare its performance to fluoroscopy and postoperative chest radiographs. Methods and Materials: A gamma scintillation survey meter was converted to a seed-migration detector by adding a shield on the probe detection window. The detector response to three {sup 125}I seed activities was characterized for different source-to-detector distances in water. The detector was used to perform a chest evaluation on 737 patients at their first postoperative visit. When the detector showed positive activity, seed migration was confirmed by taking a chest radiograph and by looking at the region with fluoroscopy. Results: One hundred and three patients (14.0%) presented at least one embolized seed. This accounts for 123 of the 39,887 seeds. Eighty-seven, 12, and 4 patients had respectively one, two, and three seed embolization. Compared with the seed-migration detector, detection based on fluoroscopy would have led to 13 false-negative detections (of 103, or 12.6%), and the radiograph would have resulted in 31 or 30.1%. More important, standard chest X-ray would have required a survey and extra radiation dose to lung to 100% of the patients, rather than the 14% who required it. Conclusions: The usual recommendation to perform chest radiographs at the first follow-up visit to scan lungs for embolized seeds should be revised because of the high false-negative rate. Scintillator-based gamma counter detector provides superior detection sensitivity and should be adopted as a standard of practice. Chest X-ray could be limited to documenting cases of positive migration.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance of the prototype module of the GlueX electromagnetic barrel calorimeter

A photon beam test of the 4 m long prototype lead/scintillating-fibre module for the GlueX electromagnetic barrel calorimeter was carried out in Hall B at the Thomas Jefferson National Accelerator Facility with the objective of measuring the energy and timing resolutions of the module as well as the number of photoelectrons generated. Data were collected over an energy range of 150 - â 650 MeV at multiple positions and angles along the module. Details of the analysis at the centre of and perpendicular to the module are shown herein; the results are View the MathML source, View the MathML source ps, and 660 photoelectrons for 1 GeV at each end of the module.

Leverington, Blake↗

A helical-shape scintillating fiber trigger and tracker system for the DarkLight experiment and beyond

The search for new physics beyond the Standard Model has interesting possibilities at low energies. For example, the recent 6.8σ anomaly reported in the invariant mass of e + e - pairs from 8 Be nuclear transitions and the discrepancy between predicted and measured values of muon g-2 give strong motivations for a protophobic fifth-force model. At low energies, the electromagnetic interaction is well understood and produces straightforward final states, making it an excellent probe of such models. However, to achieve the required precision, an experiment must address the substantially higher rate of electromagnetic backgrounds. Here in this paper, we present the results of simulation studies of a trigger system, motivated by the DarkLight experiment, using helical-shape scintillating fibers in a solenoidal magnetic field to veto electron–proton elastic scattering and the associated radiative processes. We also assess the performance of a tracking detector for lepton final states using scintillating fibers in the same setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid Lithographic and DNA-Directed Assembly of a Configurable Plasmonic Metamaterial That Exhibits Electromagnetically Induced Transparency

Metamaterials are architectures that interact with light in novel ways by virtue of symmetry manipulation, and have opened a window into studying unprecedented light-matter interactions. However, they are commonly fabricated via lithographic methods, are usually static structures, and are limited in how they can react to external stimuli. Here we show that by combining lithographic techniques with DNA-based self-assembly methods, we can construct responsive plasmonic metamaterials that exhibit the plasmonic analog of an effect known as electromagnetically induced transparency (EIT), which can dramatically change their spectra upon motion of their constituent parts. Correlative scanning electron microscopy measurements, scattering dark-field microscopy, and computational simulations are performed on single assemblies to determine the relationship between their structures and spectral responses to a variety of external stimuli. The strength of the EIT-like effect in these assemblies can be tuned by precisely controlling the positioning of the plasmonic nanoparticles in these structures. For example, changing the ionic environment or dehydrating the sample will change the conformation of the DNA linkers and therefore the distance between the nanoparticles. Dark-field spectra of individual assemblies show peak shifts of up to many tens of nanometers upon DNA perturbations. This dynamic metamaterial represents a stepping stone toward state-of-the-art plasmonic sensing platforms and next-generation dynamic metamaterials.

36 MATERIALS SCIENCE↗

Determining the gluonic gravitational form factors of the proton

The proton is one of the main building blocks of all visible matter in the Universe. Among its intrinsic properties are its electric charge, mass and spin. These properties emerge from the complex dynamics of its fundamental constituents—quarks and gluons—described by the theory of quantum chromodynamics. The electric charge and spin of protons, which are shared among the quarks, have been investigated previously using electron scattering. An example is the highly precise measurement of the electric charge radius of the proton. By contrast, little is known about the inner mass density of the proton, which is dominated by the energy carried by gluons. Gluons are hard to access using electron scattering because they do not carry an electromagnetic charge. Here we investigated the gravitational density of gluons using a small colour dipole, through the threshold photoproduction of the J/ψ particle. We determined the gluonic gravitational form factors of the proton from our measurement. Here we used a variety of models and determined, in all cases, a mass radius that is notably smaller than the electric charge radius. In some, but not all cases, depending on the model, the determined radius agrees well with first-principle predictions from lattice quantum chromodynamics. This work paves the way for a deeper understanding of the salient role of gluons in providing gravitational mass to visible matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Geometrization of Classical Wave Fields

Geometrical interpretation of quantum physics is suggested. It is shown that the Dirac equation for free quantum particles can be considered as a relation describing propagation of the space topological defect with wave and corpuscular properties. This explains all ''strange'' properties of quantum formalism: appearance of probabilities, absence of the particles trajectories, unremovable influence of the measurement procedure, instantaneous nonlocal correlation in EPR-experiments. The same interpretation is suggested for the Maxwell equations for free electromagnetic waves. This interpretation explains independence of light velocity on the source movement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi}{approx_equal}10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of X-Ray Telescopes for eROSITA and IXO

We report on the development of a generic X-ray instrument simulator to be used in simulations of future X-ray missions. Based on a Monte Carlo approach the code generates photon events for sources in an X-ray source catalogue such as the ROSAT all sky survey or the XMM-Newton slew surveys and then models the imaging and detection process based on the available calibration files (e.g., point spread functions for the imaging). The output of the program are event lists, which can be analysed using standard software such as xselect. Due to its modular concept the simulation software can be easily adapted to different concepts of imaging detectors.As examples for the potential use of the simulation we present our studies for eROSITA and show results of simulations of the detector performance for the High Time Resolution Spectrometer and the Wide Field Imager on the International X-ray Observatory.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the single polarization observables I{sup c} and I{sup s} in {pi}{sup 0{eta}} photoproduction

Meson photoproduction off the nucleon is a key tool in order to understand the structure of baryons and their excitation spectrum. Especially in the regime of high-lying resonances the photoproduction of multi-meson final states is of increasing importance, given that the cross sections for such processes exceed those for single-meson production. Additionally it gives a handle on sequential decays of such resonances via e.g. the {Delta}(1232) or the S{sub 11}(1535) in the intermediate state. For a complete understanding of the processes involved, the measurement not only of unpolarized cross sections but also of polarization observables is mandatory. With the Crystal Barrel/TAPS experiment, located at the ELSA accelerator facility in Bonn, it was possible to determine such observables using a linearly polarized photon beam impinging on a liquid hydrogen target. The beam asymmetries I{sup c} and I{sup s} are presented for the reaction gp {gamma}{sup {yields}p{yields}}p{pi}{sup 0{eta}}. The latter is a feature exclusive to the acoplanar kinematics of multi-meson final states and has been measured for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗