Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection and Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Direct detection of nonchiral dark matter

Direct detection experiments rule out fermion dark matter that is a chiral representation of the electroweak gauge group. Nonchiral real, complex and singlet representations, however, provide viable fermion dark-matter candidates. Although any one of these candidates will be virtually impossible to detect at the LHC, it is shown that they may be detected at future planned direct detection experiments. For the real case, an irreducible radiative coupling to quarks may allow a detection. The complex case in general has an experimentally ruled out tree-level coupling to quarks via Z-boson exchange. However, in the case of two SU(2){sub L} doublets, a higher-dimensional coupling to the Higgs can suppress this coupling, and a remaining irreducible radiative coupling may allow a detection. Singlet dark matter could be detected through a coupling to quarks via Higgs exchange. Since all nonchiral dark matter can have a coupling to the Higgs, at least some of its mass can be obtained from electroweak symmetry breaking, and this mass is a useful characterization of its direct detection cross section.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detecting Drawdowns Masked by Environmental Stresses with Water-Level Models

Detecting and quantifying small drawdown at observation wells distant from the pumping well greatly expands the characterized aquifer volume. However, this detection is often obscured by water level fluctuations such as barometric and tidal effects. A reliable analytical approach for distinguishing drawdown from nonpumping water-level fluctuations is presented and tested here. Drawdown is distinguished by analytically simulating all pumping and nonpumping water-level stresses simultaneously during the period of record. Pumping signals are generated with Theis models, where the pumping schedule is translated into water-level change with the Theis solution. This approach closely matched drawdowns simulated with a complex three-dimensional, hypothetical model and reasonably estimated drawdowns from an aquifer test conducted in a complex hydrogeologic system. Pumping-induced changes generated with a numerical model and analytical Theis model agreed (RMS as low as 0.007 m) in cases where pumping signals traveled more than 1 km across confining units and fault structures. Maximum drawdowns of about 0.05 m were analytically estimated from field investigations where environmental fluctuations approached 0.2m during the analysis period.

58 GEOSCIENCES↗

An IR Sounding-Based Analysis of the Saharan Air Layer in North Africa

Intense daytime surface heating over barren-to-sparsely vegetated surfaces results in dry convective mixing. In the absence of external forcing such as mountain waves, the dry convection can produce a deep, well-mixed, nearly isentropic boundary layer that becomes a well-mixed residual layer in the evening. These well-mixed layers (WML) retain their unique mid-tropospheric thermal and humidity structure for several days. To detect the SAL and characterize its properties, AIRS Level 2 Ver. 6 temperature and humidity products (2003-Present) are evaluated against rawinsondes and compared to model analysis at each of the 55 rawinsonde stations in northern Africa. To distinguish WML from Saharan air layers (WMLs of Saharan origin), the detection involved a two-step process: 1) algorithm-based detection of WMLs in dry environments (less than 7 g per kilogram mixing ratio) 2) identification of Sahara air layers (SAL) by applying Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) back trajectories to determine the history of each WML. WML occurrence rates from AIRS closely resemble that from rawinsondes, yet rates from model analysis were up to 30% higher than observations in the Sahara due to model errors. Despite the overly frequent occurrence of WMLs from model analysis, HYSPLIT trajectory analysis showed that SAL occurrence rates (given a WML exists) from rawinsondes, AIRS, and model analysis were nearly identical. Although the number of WMLs varied among the data sources, the proportion of WMLs which were classified as SAL was nearly the same. The analysis of SAL bulk properties showed that AIRS and model analysis exhibited a slight warm and moist bias relative to rawinsondes in non-Saharan locations, but model analysis was notably warmer than rawinsondes and AIRS within the Sahara. The latter result is likely associated with the dearth of available data assimilated by model analysis in the Sahara. The variability of SAL thicknesses was reasonably captured by both AIRS and model analysis, but the former favor layers than are thinner than observations. Finally, further analysis of HYSPLIT trajectories revealed that fewer than 10% and 33% of all SAL back trajectories passed through regions with notable precipitation (>100 mm accumulated along the trajectory path) or Aerosol Optical Depth (AOD greater than 0.4, 75th percentile of AOD) on average, respectively. Trajectory analysis indicated that only 57% of Saharan and 24% of non-Saharan WMLs are definitively of Saharan origin (Saharan requirement: Two consecutive days in Sahara and 24 or more of those hours within 72 hours of detection). Non-SAL WMLs either originate from local-to-regionally generated residual layers or from mid-latitude air streams that do not linger over the Sahara for a sufficient time period. Initial analysis shows these non-SAL WMLs tend to be both notably cooler and slightly moister than their SAL counter parts. Continuing analysis will address what role Saharan and non-Saharan air masses characteristics may play on local and regional environmental conditions.

Nicholls, Stephen D.↗

THE CENTER OF LIGHT: SPECTROASTROMETRIC DETECTION OF EXOMOONS

Direct imaging of extrasolar planets with future space-based coronagraphic telescopes may provide a means of detecting companion moons at wavelengths where the moon outshines the planet. We propose a detection strategy based on the positional variation of the center of light with wavelength, “spectroastrometry.” This new application of this technique could be used to detect an exomoon, to determine the exomoon’s orbit and the mass of the host exoplanet, and to disentangle the spectra of the planet and moon. We consider two model systems, for which we discuss the requirements for detection of exomoons around nearby stars. We simulate the characterization of an Earth–Moon analog system with spectroastrometry, showing that the orbit, the planet mass, and the spectra of both bodies can be recovered. To enable the detection and characterization of exomoons we recommend that coronagraphic telescopes should extend in wavelength coverage to 3 μm, and should be designed with spectroastrometric requirements in mind.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization and Monte Carlo Simulations of a 4-Liter NaI Detection System for Use During Nuclear and Radiological Emergencies and for the Detection of Nuclear Materials

SCKCEN is engaged in research related to the use of a large volume NaI detection system for use during nuclear and radiological emergencies and for the detection of nuclear materials. As part of this effort a research activity is being carried out to determine the characteristics and build a Monte Carlo model of the available 4-liter NaI detector. These activities consist of (i) determination of energy resolution efficiency lower threshold background in laboratory conditions using well-characterized point sources; (ii) modeling of the detector by Monte Carlo methods and validation; (iii) determination of the response function by combining measurement and simulation results; (iv) characterization of the detector for contaminated surfaces by measurements and modeling; and (v) calibration of detector for dose rate measurements. This paper will focus on the results obtained so far concerning the Monte Carlo model and its validation with experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multilateral Testing Workshop on Relocatable Portal Monitors

The procurement and deployment of radiation detection equipment is a multi-faceted challenge across the globe. Knowledge sharing of the testing methods used to evaluate equipment for deployment scenarios helps improve the understanding of deployed systems by the global community. The United States Department of Energy’s Nuclear Smuggling Detection and Deterrence Office (NSDD) performed a series of characterization measurements in 2019, focused on radiation detection systems that could function as relocatable portal monitors. The capstone activity for this project was a multilateral and cross-disciplinary workshop demonstrating, performing, and refining the techniques used in the characterization measurements with International Atomic Energy Agency (IAEA) and global partners. A group of technical experts including representatives from nine countries, the IAEA, and NSDD gathered at Sandia National Laboratories in Albuquerque, NM during September of 2019 for the Operational and Performance Testing and Evaluation of Relocatable Portals Workshop. Over the course of a week, the group discussed the necessity for and process of developing operational and performance requirements, challenges related to deploying radiation detection systems for the countries in attendance, use cases for deploying relocatable radiation detection equipment, and considerations related to testing equipment for appropriate deployment scenarios. All participants were given the opportunity to have hands-on experience with eleven relocatable systems in executing a limited scope characterization test comprised of six test scenarios. At the conclusion of testing, participants reviewed and presented their findings, and the group as a whole compared and contrasted their experiences. Suggested revisions to the test methods and ideas for further collaborations were discussed. This report discusses the logistical and planning considerations for bringing together experts across disciplines in a multilateral workshop on testing of radiation detectors, as well as presenting the testing methods performed, results, and paths forward. Success of workshops related to technical knowledge transfer and improvement of test methods is key to global technical and scientific support of radiation detection deployments.

Erchinger, Jennifer L.↗

A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions

Characterization of unintended radiated emissions (URE) from electronic devices plays an important role in many research areas from electromagnetic interference to nonintrusive load monitoring to information system security. URE can provide insights for applications ranging from load disaggregation and energy efficiency to condition-based maintenance of equipment-based upon detected fault conditions. URE characterization often requires subject matter expertise to tailor transforms and feature extractors for the specific electrical devices of interest. We present a novel approach, named dimensionally aligned signal projection (DASP), for projecting aligned signal characteristics that are inherent to the physical implementation of many commercial electronic devices. These projections minimize the need for an intimate understanding of the underlying physical circuitry and significantly reduce the number of features required for signal classification. We present three possible DASP algorithms that leverage frequency harmonics, modulation alignments, and frequency peak spacings, along with a two-dimensional image manipulation method for statistical feature extraction. To demonstrate the ability of DASP to generate relevant features from URE, we measured the conducted URE from 14 residential electronic devices using a 2 MS/s collection system. Furthermore, a linear discriminant analysis classifier was trained using DASP generated features and was blind tested resulting in a greater than 90% classification accuracy for each of the DASP algorithms and an accuracy of 99.1% when DASP features are used in combination. Furthermore, we show that a rank reduced feature set of the combined DASP algorithms provides a 98.9% classification accuracy with only three features and outperforms a set of spectral features in terms of general classification as well as applicability across a broad number of devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen and its detection in fusion and fission nuclear materials – a review

We report fusion and fission reactions are profoundly dependent on hydrogen for sustained reactions. Fusion is fueled by the isotopes of hydrogen, and predominantly hydrogen-based moderators slow fission neutrons to propagate chain reactions. Intentional tritium production in fusion and concomitant tritium production in fission reactors introduce challenges. The technology to efficiently extract, harvest, and quantify tritium in and from advanced fission molten salt coolants and fusion molten tritium breeder materials will require more pronounced research and development. Measuring and quantifying hydrogen is necessary in all areas of nuclear materials. Although many characterization techniques cannot directly detect hydrogen, numerous techniques provide the necessary information to understand the behavior of hydrogen in nuclear materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detection of Petawatt Laser-Induced Muon Source for Rapid High-Z Material Detection

A proof-of-concept investigation of a rapid detection system for shielded high-Z material using a petawatt laser-based muon source is presented. Unlike cosmic-ray muons, a laser-induced muon beam has unique characteristics that can be exploited for use in a rapid detection system. These characteristics include: (1) a near-point source of muons, (2) well-characterized muon energies, and (3) directionality of the beam. A detector system is being developed that combines multiple muon detection technologies to characterize an active muon source. This detection system and the associated data acquisition and analysis techniques are designed to search for deflections of the muon beam as it passes through high-Z materials. Additionally, the ability of the system to differentiate muons from the expected secondary particles, such as high-energy gammas and electrons, is being explored. The detector system’s ability to differentiate muons from other particles, show muon angular distribution, and measured muon flux will be discussed.

scintillation detector, petawatt laser-based muon ↗

Trade Study for Neutron Transport at Low Earth Orbit: Adding Fidelity to DIORAMA

The Distributed Infrastructure Offering Real-Time Access to Modeling and Analysis (DIORAMA) software provides performance modeling capabilities of the United States Nuclear Detonation Detection System (USNDS) with a focus on the characterization of Space-Based Nuclear Detonation Detection (SNDD) instrument performance [1]. A case study was done to add the neutron propagation capabilities of DIORAMA to low earth orbit (LEO), and compare the back-calculated incident energy from the time-of- ight (TOF) spectrum with the scored incident energy spectrum. As the scoring altitude lowers, the time increase due to scattering takes up much more of the fraction of total TOF; whereas at geosynchronous earth orbit (GEO), the time increase due to scattering is a negligible fraction of the total TOF [2]. The scattering smears out the TOF enough to make the back-calculation of the initial energy spectrum from the TOF spectrum very convoluted.

79 ASTRONOMY AND ASTROPHYSICS↗

Modification of the collective Thomson scattering radiometer in the search for parametric decay on TEXTOR

Strong scattering of high-power millimeter waves at 140 GHz has been shown to take place in heating and current-drive experiments at TEXTOR when a tearing mode is present in the plasma. The scattering signal is at present supposed to be generated by the parametric decay instability. Here we describe the heterodyne detection system used to characterize the newly discovered signal measured at TEXTOR, and we present spectral shapes in which the signal can appear under different conditions. The radiation is collected by the receiver through a quasi-optical transmission line that is independent of the electron cyclotron resonance heating transmission line, and so the scattering geometry is variable. The signal is detected with 42 frequency channels ranging from 136 to 142 GHz. We demonstrate that the large signal does not originate from gyrotron spurious radiation. The measured signal agrees well with independent backscattering radiometer data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Presence Detection in Connected Lighting Systems

Despite established technology and decades of experience, presence detection still faces challenges, including resistance to its use. This report provides context for current presence detection in lighting, considers various failure modes and their causes, characterizes various approaches to implementing presence detection, and describes performance evaluation as conducted in classrooms and offices at the Living Lab.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification of PAH Isomeric Structure in Cosmic Dust Analogs: The AROMA Setup

We developed a new analytical experimental setup called AROMA (Astrochemistry Research of Organics with Molecular Analyzer) that combines laser desorption/ionization techniques with ion trap mass spectrometry. We report here on the ability of the apparatus to detect aromatic species in complex materials of astrophysical interest and characterize their structures. A limit of detection of 100 femto-grams has been achieved using pure polycyclic aromatic hydrocarbon (PAH) samples, which corresponds to 2 × 10{sup 8} molecules in the case of coronene (C{sub 24}H{sub 12}). We detected the PAH distribution in the Murchison meteorite, which is made of a complex mixture of extraterrestrial organic compounds. In addition, collision induced dissociation experiments were performed on selected species detected in Murchison, which led to the first firm identification of pyrene and its methylated derivatives in this sample.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-G-204-07: Automated Characterization of Perceptual Quality of Clinical Chest Radiographs: Improvements in Lung, Spine, and Hardware Detection

Purpose: To develop and validate more robust methods for automated lung, spine, and hardware detection in AP/PA chest images. This work is part of a continuing effort to automatically characterize the perceptual image quality of clinical radiographs. [Y. Lin et al. Med. Phys. 39, 7019–7031 (2012)] Methods: Our previous implementation of lung/spine identification was applicable to only one vendor. A more generalized routine was devised based on three primary components: lung boundary detection, fuzzy c-means (FCM) clustering, and a clinically-derived lung pixel probability map. Boundary detection was used to constrain the lung segmentations. FCM clustering produced grayscale- and neighborhood-based pixel classification probabilities which are weighted by the clinically-derived probability maps to generate a final lung segmentation. Lung centerlines were set along the left-right lung midpoints. Spine centerlines were estimated as a weighted average of body contour, lateral lung contour, and intensity-based centerline estimates. Centerline estimation was tested on 900 clinical AP/PA chest radiographs which included inpatient/outpatient, upright/bedside, men/women, and adult/pediatric images from multiple imaging systems. Our previous implementation further did not account for the presence of medical hardware (pacemakers, wires, implants, staples, stents, etc.) potentially biasing image quality analysis. A hardware detection algorithm was developed using a gradient-based thresholding method. The training and testing paradigm used a set of 48 images from which 1920 51×51 pixel{sup 2} ROIs with and 1920 ROIs without hardware were manually selected. Results: Acceptable lung centerlines were generated in 98.7% of radiographs while spine centerlines were acceptable in 99.1% of radiographs. Following threshold optimization, the hardware detection software yielded average true positive and true negative rates of 92.7% and 96.9%, respectively. Conclusion: Updated segmentation and centerline estimation methods in addition to new gradient-based hardware detection software provide improved data integrity control and error-checking for automated clinical chest image quality characterization across multiple radiography systems.

60 APPLIED LIFE SCIENCES↗

XRF Characterization of MMOD Impact Damage

Introduction The Hypervelocity Impact Technology (HVIT) Group at the NASA Johnson Space Center (JSC) has performed over 150 post flight MMOD inspections on returned space-ex-posed hardware and collected over 1,600 samples. Determination of the impactor source typically requires an analysis of the projectile residue in the damage feature. At this time, about 20% of the samples have been processed. Types of Samples Samples in the HVIT group collection can be classified into two types. Indirect (non-destructive) samples are produced when a pliable material (e.g., adhesive tape or dental mold) is inserted into an impact feature. With this type of sampling technique, crater material and (hopefully) projectile residue material is embedded in the sample media and can detected using further chemical characterizing techniques. Direct (destructive) sampling involves the in-tact extraction of material from the spacecraft and is done in a manner that the entire impact feature can be excised intact. This technique provides the greatest chance of successfully determining impactor source due to the entirety of the projectile remnants being present within the collected sample. Updated Projectile Residue Detection Techniques Previous assessments of projectile provenance have involved the use of samples that are first mounted in epoxy, sectioned to expose the crater interior, imaged with a scanning electron microscope (SEM), then any observed impactor residue was then analyzed using an energy dispersive spectrometer (EDS). This technique, while proven, may be supplemented with other types of elemental analysis techniques that can observe major element chemistry, in order to improve throughput of sample analysis. The Astromaterials Research and Exploration Science (ARES) Division at JSC, for example, operates a Bruker M4 Tornado micro-X-Ray fluorescence (XRF) spectrometer, capable of creating elemental maps of areas around these small impact features in a couple of hours, with a spot size <20 μm. The potential advantage with this technique lies in sample preparation, as no polishing or conductive coatings are needed. Early trials attempted to deter-mine impactor composition by collecting spectra from intact samples by aiming the X-Rays directly into the impact feature, but the signal:noise ratio was too low for confident material identification. Sample preparation for XRF then relies on sectioning the samples parallel to the impactor trajectory in order to expose the largest area of subsurface damage possible, thus maximizing the signal from any small impactor remnants. Complementary to the use of XRF for sample analysis, ARES also houses a Nikon XTH 320 micro-X-Ray computed tomography (XCT). This instrument can be used to create 3D visualizations of impact damage for the determination of crater volumes and dimensions, as well as for the determination of the best place to section each sample for the subsequent XRF analysis.

J L Hyde↗

In-Situ FTIR Detection of Transition Metal (TM)-Ion Dissolution From Cathodes in Li-Ion Batteries

Transition metal (TM) ions, commonly Ni and Mn, play a crucial role in Li-ion battery cathodes as the reaction centers for rapid redox reactions. A major challenge with TM-based cathodes is capacity degradation, particularly at higher operating voltages. This degradation is closely linked to the dissolution of TMs from the cathode materials and their subsequent deposition on the anode. This process not only modifies the surface structure of the cathode but, more significantly, alters the SEI composition on the anode [1-2]. The dissolution of TMs cations into a liquid electrolyte from cathode materials, such as Mn-ion dissolution from Mn-rich cathode (LMR), is detrimental to the cycling performance of Li-ion batteries [3-4]. Much attention has been paid to this issue but there remains a lack of characterization techniques which can detect the TM-ion dissolution from the cathode during electrochemical measurements. In our study, we use in-situ ATR-FTIR as an effective technique to probe the TM-ion dissolution from the cathode. We have first demonstrated the detrimental effects of TM ions on the electrochemical performance of Li-ion batteries by adding a small amount of TM salt (50 mM Mn(PF6)) to the electrolyte of a Li-ion coin cell with LFP and graphite electrode. We observed a rapid capacity fade after the first delithiation cycle. To investigate TM ion dissolution, we established a baseline IR spectrum for various TM solvation states (such as Mn and Ni) by measuring concentration-dependent IR spectra. This baseline spectrum helps us detect TM ion dissolution during battery cycling. In this work, we discuss in detail the effect of TM ions on the electrochemical performance of Li-ion batteries and the detection of TM ions during battery cycling using in-situ FTIR spectroscopy. We will compare TM dissolution between coated and uncoated cathodes to examine the effect of cathode coatings to mitigate degradation due to TM dissolution and cross-over from cathode to anode. References: (1) Zhan, C.; Wu, T.; Lu, J.; Amine, K. Dissolution, migration, anddeposition of transition metal ions in Li-ion batteries exemplified byMn-based cathodes - a critical review. Energy Environ. Sci. 2018, 11,243-257. (2) Jung, R.; Linsenmann, F.; Thomas, R.; Wandt, J.; Solchenbach,S.; Maglia, F.; Stinner, C.; Tromp, M.; Gasteiger, H. A. Nickel,Manganese, and Cobalt Dissolution from Ni-Rich NMC and TheirEffects on NMC622-Graphite Cells. J. Electrochem. Soc. 2019, 166,A378-A389. (3) Zhao, L.; Chenard, E.; Capraz, O. O.; Sottos, N. R.; White, S.R. Direct Detection of Manganese Ions in Organic Electrolyte by UV-Vis Spectroscopy. J. Electrochem. Soc. 2018, 165, A345-A348 (4) Zhang, Y.; Hu, A.; Xia, D.; Hwang, S.; Sainio, S.; Nordlund, D.;Michel, F. M.; Moore, R. B.; Li, L.; Lin, F. Operando characterization and regulation of metal dissolution and redeposition dynamics nearbattery electrode surface. Nat. Nanotechnol. 2023, 18, 790.

25 ENERGY STORAGE↗

Observing the formation of flare-driven coronal rain

Flare-driven coronal rain can manifest from rapidly cooled plasma condensations near coronal loop tops in thermally unstable postflare arcades. We detect five phases that characterize the postflare decay: heating, evaporation, conductive cooling dominance for ∼120 s, radiative/enthalpy cooling dominance for ∼4700 s, and finally catastrophic cooling occurring within 35–124 s, leading to rain strands with a periodicity of 55–70 s. We find an excellent agreement between the observations and model predictions of the dominant cooling timescales and the onset of catastrophic cooling. At the rain-formation site, we detect comoving, multithermal rain clumps that undergo catastrophic cooling from ∼1 MK to ∼22,000 K. During catastrophic cooling, the plasma cools at a maximum rate of 22,700 K s{sup −1} in multiple loop-top sources. We calculated the density of the extreme-ultraviolet (EUV) plasma from the differential emission measure of the multithermal source employing regularized inversion. Assuming a pressure balance, we estimate the density of the chromospheric component of rain to be 9.21 × 10{sup 11} ± 1.76 × 10{sup 11} cm{sup −3}, which is comparable with quiescent coronal rain densities. With up to eight parallel strands in the EUV loop cross section, we calculate the mass loss rate from the postflare arcade to be as much as 1.98 × 10{sup 12} ± 4.95 × 10{sup 11} g s{sup −1}. Finally, we reveal a close proximity between the model predictions of 10{sup 5.8} K and the observed properties between 10{sup 5.9} and 10{sup 6.2} K, which defines the temperature onset of catastrophic cooling. The close correspondence between the observations and numerical models suggests that indeed acoustic waves (with a sound travel time of 68 s) could play an important role in redistributing energy and sustaining the enthalpy-based radiative cooling.

79 ASTRONOMY AND ASTROPHYSICS↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗