Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Rapid acquisition of data dense solid-state CPMG NMR spectral sets using multi-dimensional statistical analysis

The development of multi-dimensional statistical methods has been demonstrated on variable contact time (VCT) 29 Si{ 1 H} cross-polarization magic angle spinning (CP/MAS) data sets collected using Carr–Purcell–Meiboom–Gill (CPMG) type acquisition. These methods utilize the transformation of the collected 2D VCT data set into a 3D data set and use tensor-rank decomposition to extract the spectral components that vary as a function of transverse relaxation time ( T 2 ) and CP contact time. The result is a data dense spectral set that can be used to reconstruct CP/MAS spectra at any contact time with a high signal to noise ratio and with an excellent agreement to 29 Si{ 1 H} CP/MAS spectra collected using conventional acquisition. These CPMG data can be collected in a fraction of time that would be required to collect a conventional VCT data set. Here, we demonstrate the method on samples of functionalized mesoporous silica materials and show that the method can provide valuable surface specific information about their functional chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

General-purpose interface bus for multiuser, multitasking computer system

The architecture of a multiuser, multitasking, virtual-memory computer system intended for the use by a medium-size research group is described. There are three central processing units (CPU) in the configuration, each with 16 MB memory, and two 474 MB hard disks attached. CPU 1 is designed for data analysis and contains an array processor for fast-Fourier transformations. In addition, CPU 1 shares display images viewed with the image processor. CPU 2 is designed for image analysis and display. CPU 3 is designed for data acquisition and contains 8 GPIB channels and an analog-to-digital conversion input/output interface with 16 channels. Up to 9 users can access the third CPU simultaneously for data acquisition. Focus is placed on the optimization of hardware interfaces and software, facilitating instrument control, data acquisition, and processing.

Generazio, Edward R.↗

WE-FG-BRA-04: A Portable Confocal Microscope to Image Live Cell Damage Response Induced by Therapeutic Radiation

Purpose: To construct a custom and portable fluorescence confocal laser-scanning microscope (FCLSM) that can be placed in the path of therapeutic radiation beams to study real-time radiation-induced damage response in live cells. Methods: We designed and constructed a portable FCLSM with three laser diodes for excitation (405, 488, and 635 nm). An objective lens focuses the excitation light and collects fluorescence from the sample. A pair of galvanometer mirrors scans/collects the laser beam/fluorescence along the focal plane (x/y-directions). A stepper motor stage scans in the axial direction and positions the x/y of the image field. Barrier filters and dichroic mirrors are used to route the spectral emission bands to the appropriate photodetector. An avalanche photodiode collects near-infrared fluorescence; a photodiode collects back-reflected 635 nm light; and a photomultiplier tube collects green fluorescence in the range of eGFP/eYFP. A 200-µm diameter pinhole was used to implement the confocal geometry for near-infrared and red channels and a 150-µm diameter pinhole for the green channel. Data acquisition and system control were achieved using a high-throughput data acquisition card. In-house software developed in LabVIEW was used to control the hardware, collect data from the photodetectors and reconstruct the confocal images. Results: 6 frames/s can be acquired for a 25 µm{sup 2} (128×128 pixels) field of view, visualizing the entire volume of the cell nucleus (∼10 µm depth) in <10 s. To demonstrate the usefulness of our FCLSM, we imaged gold nanoshells in live cells, radiation-induced damage in fibrosarcoma cells expressing eGFP tagged to a DNA repair protein, and neurons expressing eGFP. The system can also image particle tracks in fluorescent nuclear track detectors. Conclusion: We developed a versatile and portable FCLSM that allows radiobiology studies in live cells exposed to therapeutic radiation. The FCLSM can be placed in any vertical beam line for top-to-bottom exposures. This research was supported by the Sister Institution Network Fund and the Center for Radiation Oncology Research at The University of Texas MD Anderson Cancer Center and Cancer Prevention and Research Institute of Texas. Gabriel Sawakuchi has research support from Elekta Inc.

60 APPLIED LIFE SCIENCES↗

Concepts for on board satellite image registration. Volume 4: Impact of data set selection on satellite on board signal processing

The NASA NEEDS program goals present a requirement for on-board signal processing to achieve user-compatible, information-adaptive data acquisition. This volume addresses the impact of data set selection on data formatting required for efficient telemetering of the acquired satellite sensor data. More specifically, the FILE algorithm developed by Martin-Marietta provides a means for the determination of those pixels from the data stream effects an improvement in the achievable system throughput. It will be seen that based on the lack of statistical stationarity in cloud cover, spatial distribution periods exist where data acquisition rates exceed the throughput capability. The study therefore addresses various approaches to data compression and truncation as applicable to this sensor mission.

Ruedger, W. H.↗

DOE and JAEA Field Trial of the Single Chip Shift Register (SCSR)

Los Alamos National Laboratories (LANL) has recently developed a new data acquisition system for multiplicity analysis of neutron detector pulse streams. This new technology, the Single Chip Shift Register (SCSR), places the entire data acquisition system along with the communications hardware onto a single chip. This greatly simplifies the instrument and reduces the size. The SCSR is designed to be mounted into the neutron detector head alongside the instrument amplifiers. The user’s computer connects via USB directly to the neutron detector eliminating the external data acquisition electronics entirely. JAEA, through the INSEP program, asked LANL to demonstrate the functionality of the SCSR in Tokai using the JAEA Epithermal Neutron Multiplicity Counter, ENMC. In late September of 2015 LANL traveled to Tokai to install, demonstrate and uninstall the SCSR in the ENMC. This report documents the results of that field trial.

97 MATHEMATICS AND COMPUTING↗

Using Low-Cost “Garage Band” Recording Technology for Acquiring High Resolution High-Speed Data

The Oak Ridge National Laboratory (ORNL) has developed and tested a novel system architecture for acquiring high fidelity high-speed data. The approach uses a consumer grade audio recording device that is normally associated with “garage band” recording of music. ORNL has coupled this low-cost data acquisition hardware with computing technology running open-source software. The main advantage of this approach is per-channel cost; an instrument grade data acquisition system typically costs between $800 to $2000 per channel compared to less than $50 per channel for these consumer grade components. Three systems, each featuring four channels, have been deployed for acquiring data from geophones and the electrical supply system that supports the High Flux Isotope Reactor (HFIR) and the Radiochemical Engineering Development Center (REDC) at ORNL. Each channel samples at 96 kHz at 24-bit resolution. The deployed systems operate continuously 24/7 and produce about 4 terabytes of data per month per system. This paper provides a technical overview of this approach, its implementation, and some preliminary results from qualification testing. This work was conducted in support of the Multi-Informatics for Nuclear Operations Scenarios (MINOS).Keywords: Data acquisition Measurement Informatics

Wetherington Jr, G↗

Non-intrusive, high-resolution, real-time, two-dimensional imaging of multiphase materials using acoustic array sensors

Two parallel multi-element ultrasonic acoustic arrays combined with sets of focal laws for acoustic signal generation and a classical tomographic inversion algorithm are used to generate real-time two-dimensional micro seismic acoustic images of multiphase materials. Proof of concept and calibration measurements were performed for single phase and two phase liquids, uniform polyvinyl chloride (PVC) plates, and aluminum cylinders imbedded in PVC plates. Measurement artefacts, arising from the limited range of viewing angles, and the compromise between data acquisition rate and image quality are discussed. The angle range of scanning and the image resolution were varied, and the effects on the quality of the reproduction of the speed of sound profiles of model solids and liquids with known geometries and compositions were analysed in detail. The best image quality results were obtained for a scanning angle range of [−35°, 35°] at a step size of 2.5° post processed to generate images on a 40 μm square grid. The data acquisition time for high quality images with a 30 mm × 40 mm view field is 10 min. Representation of two-phase solids with large differences in speed of sound between phases and where one phase is dispersed in the form of macroscopic objects (greater than 1 mm in diameter) proved to be the most difficult to image accurately. Liquid-liquid and liquid-vapor phase boundaries, in micro porous solids by contrast, were more readily defined. Displacement of air by water and water by heptane in natural porous limestone provides illustrative kinetic examples. Measurement results with these realistic cases demonstrate the feasibility of the technique to monitor in real time and on the micrometer length scale local composition and flow of organic liquids in inorganic porous media, one of many envisioned engineering applications. Improvement of data acquisition rate is an area for future collaborative study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancements and Deployment of the TDAQ System for the Mu2e Experiment

The Real Time Processing Systems Division at Fermilab has deployed new features to the Off-The-Shelf Data Acquisition framework (otsdaq) for the Mu2e experiment. The Mu2e experiment will search for the coherent neutrino-less conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement of 10,000 times over existing limits. Such a charged lepton flavor-violating reaction probes new physics at a scale unavailable at present or planned high-energy colliders. The Mu2e Trigger and Data Acquisition (TDAQ) system uses otsdaq as its online Data Acquisition System (DAQ) framework. otsdaq integrates the artdaq and art frameworks for event transfer, filtering, and processing. otsdaq is a web-based DAQ software suite focusing on flexibility and scalability and provides a multi-user interface accessible through a web browser. artdaq handles the entire data stream, which is read over the peripheral component interconnect express (PCIe) bus to a software filter algorithm that selects events combined with the data flux coming from a cosmic-ray veto (CRV) system. Detector front-ends are configured through the PCIe bus by customized otsdaq plugins. The otsdaq slow controls infrastructure has been further developed using the experimental physics and industrial control system (EPICS) open-source platform for monitoring, controlling, alarming, and archiving. The detector control system (DCS) for Mu2e has been integrated into otsdaq. The production TDAQ and DCS system has been deployed at the experimental hall and is being debugged and optimized for experiment operations. We report on the feature enhancements and deployment of otsdaq for Mu2e.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement and Analysis of Atmospheric Spectral Optical Depths with NASA Ames Airborne Sunphotometers During TARFOX and ACE-2

In accordance with the scope of work of this contract, the following tasks were undertaken and completed during the course of the contract: (1) Participation in the design and development of the 14-channel Ames Airborne Tracking Sunphotometer (AATS-14), including the development and implementation of Visual Basic software for real-time data processing and display and post-acquisition data reduction and analysis. (2) Operation of the six-channel Ames Airborne Tracking Sunphotometer (AATS-6) aboard the University of Washington C-131A during TARFOX and in-field analysis and presentation of data acquired with the AATS-6. (3) Post-mission analysis of data acquired during TARFOX with the AATS-6 and the AATS-14. (4) Pre-TARFOX calibration of the AATS-6 at Mauna Loa Observatory in May 1996, and post-TARFOX calibration of the AATS-6 and AATS- 14 at Zugspitze, Germany in October 1996, including analyses of all data sets. (5) Analysis of AATS-14 airborne calibration data acquired on 17 November 1996 during a late afternoon Pelican flight over the central California coast. (6) Operational training, instrument preparation, field coordination, and analysis of shipboard measurements of aerosol optical depth with the AATS-6 during ACE-2. (7) Coordination of data acquisition with the AATS-14 aboard the Pelican during ACE-2 and in-field preliminary data analysis and presentation. (8) Calibration of the AATS-6 and AATS-14 in April/May 1997 at Mauna Loa prior to ACE-2, and post-mission calibration of the AATS-6 at Mauna Loa in August 1997.

Livingston, John M.↗

High-Penetration PV Deployment in the Arizona Public Service System, Phase 1 Update: Preprint

In an effort to better understand the impacts of high penetrations of photovoltaic generators on distribution systems, Arizona Public Service and its partners have begun work on a multi-year project to develop the tools and knowledge base needed to safely and reliably integrate high penetrations of utility- and residential-scale photovoltaics (PV). Building upon the APS Community Power Project --Flagstaff Pilot, this project will analyze the impact of PV on a representative feeder in northeast Flagstaff. To quantify and catalog the effects of the estimated 1.3 MW of PV that will be installed on the feeder (both smaller units at homes as well as large, centrally located systems), high-speed weather and electrical data acquisition systems and digital 'smart' meters are being designed andinstalled to facilitate monitoring and to build and validate comprehensive, high-resolution models of the distribution system. These models will be used to analyze the impacts of the PV on distribution circuit protection systems (including anti-islanding), predict voltage regulation and phase balance issues, and develop volt/var control schemes. This paper continues from a paper presented at the2011 IEEE PVSC conference that introduces the project and describes some of the preliminary consideration, as well as project plans and early results. This paper gives a status update of the project and presents selected results from Phase 2 of the project. It discusses baseline feeder modeling, load allocation, data acquisition, utility-scale PV integration, preliminary model validation, andplans for future phases.

14 SOLAR ENERGY↗

Test equipment data package for the KC-135 fiber pulling apparatus

The Fiber Pulling Apparatus (FPA) is a device designed to produce continuous glass fibers from simulated lunar soil, and to determine the effects of reduced gravity, specifically 1/6 g on fiber formation and resultant properties. Briefly, pre-melt simulated lunar soil will be placed in a pint crucible and heated to 1200 C or higher, up to a maximum temperature of 1400 C. At a given temperature, a quartz fiber will be immersed into the melt and then pulled through a chill block and wound onto a cylindrical bobbin using a servo motor control. A high resolution video camera will record the fiber as it is being pulled. This assembly wil be enclosed in Plexiglas. Before fiber pulling commences, the apparatus will be backfilled with dry nitrogen. A separate data acquisition system will support this apparatus. This system will contain a personal computer, video recorder, and monitor. Temperature, acceleration, winding speed, and video images will be controlled and recorded using the data acquisition system. Thus, the FPA will consist of two hardware packages, the fiber production assembly and the data acquisition rack. The primary objective of this test is to determine the effects of 1/6 g on the formation of continuous glass fiber made from simulated lunar soil. Baseline studies using the FPA on the ground will provide a reference for the 1/6 g studies. Of particular interest will be the effect of 1/6 g on the free fluid zone where the fiber exits the crucible. In the fiber spinning parlance this zone is known as the upper jet region, where the boundary slope is greater than one tenth. The properties of the resulting glass fiber will depend on the jet shape as well as distributions of velocity, temperature and tension within the jet. It is unknown at this time how 1/6 g will effect these parameters.

Kosten, Sue↗

Modular Subsurface Sensors and Integrated Software for Advanced Subsurface Characterization and Monitoring using Unoccupied Vehicles

The advent and subsequent proliferation of autonomous airborne, waterborne, and groundbased vehicles (i.e., “drones”) promises to broadly transform the geosciences and associated industries, including fossil energy exploration and development, mineral resource exploration and development, water-resource management, and environmental remediation. For geophysical characterization and monitoring, the prospect of programming highly repeatable and low-cost drone missions for subsurface imaging will allow for deployments in hazardous and previously inaccessible areas. Coupled with autonomous workflows for data processing, management, and visualization, drone-based geophysical characterization and monitoring will enable unprecedented, real-time insight into diverse subsurface properties and processes of scientific and engineering importance. Toward this end, the objectives of this Lab Directed Research and Development (LDRD) project were to develop new (1) instrumentation for dronebased electromagnetic induction (EMI) geophysical imaging, including separated transmitter and receivers and associated electronics, (2) software for real-time data telemetry, processing, management, and visualization. Although EMI has been previously deployed using unoccupied aerial systems (UASs), these applications failed to capitalize on the game-changing capabilities of drone platforms. Whereas drone-based data acquisition allows for collection of rich, three-dimensional (3D) multi-offset/multi-angle configurations between transmitters and receivers, past efforts have relied on conventional instrumentation that was designed for ground-based data collection with the transmitter and a single receiver housed in the same unit; nor did these previous applications demonstrate real-time delivery of results to support rapid management decisions in the field. In this 1-year project, we (1) designed and constructed new lightweight independent transmitter and receiver antenna platforms that communicate with a laptop computer; (2) developed software to control data acquisition, manage/transfer data, and visualize data as its collected; and (3) demonstrated the operation of the new hardware and software systems in a ground-based field test. Our work entails major technological advances for EMI and established a foundation on which to build a new drone-based, real-time geophysical EMI imaging capability to support diverse challenges facing the nation.

47 OTHER INSTRUMENTATION↗

Prototypes of self-powered radiation detectors employing intrinsic high-energy current

Purpose: The authors experimentally investigate the effect of direct energy conversion of x-rays via selfpowered Auger- and photocurrent, potentially suitable to practical radiation detection and dosimetry in medical applications. Experimental results are compared to computational predictions. The detector the authors consider is a thin-film multilayer device, composed of alternating disparate electrically conductive and insulating layers. This paper focuses on the experiments while a companion paper introduces the fundamental concepts of high-energy current (HEC) detectors. Methods: The energy of ionizing radiation is directly converted to detector signal via electric current induced by high-energy secondary electrons generated in the detector material by the incident primary radiation. The HEC electrons also ionize the dielectric and the resultant charge carriers are selfcollected due to the contact potential of the disparate electrodes. Thus, an electric current is induced in the conductors in two different ways without the need for externally applied bias voltage or amplification. Thus, generated signal in turn is digitized by a data acquisition system. To determine the fundamental properties of the HEC detector and to demonstrate its feasibility for medical applications, the authors used a planar geometry composed of multilayer microstructures. Various detectors with up to seven conducting layers with different combinations of materials (250 μm Al, 35 μm Cu, 100 μm Pb) and air gaps (100 μm) were exposed to nearly plane-parallel 60–120 kVp x-ray beams. For the experimental design and verification, the authors performed coupled electron–photon radiation transport computations. The detector signal was measured using a commercial data acquisition system with 24 bits dynamic range, 0.4 fC sensitivity, and 0.9 ms sampling time. Results: Measured signals for the prototype detector varied depending on the number of layers, material type, and incident photon energy, and it was in the range of 30–150 nA/cm{sup 2} for unit air kerma (1 Gy), which is viable for practical applications. The experiments had an excellent agreement with the computations. Within the examined range of 60–120 kVp, the energy dependence of the HEC (normalized to the x-ray tube output) was relatively small. Conclusions: Based on the experimental results for 100 ms sampling time, it would be possible to measure the time dependence of x-ray beams for x-ray tube current of 0.1 mA or higher. Significant advantages of the HEC device are that generation of its signal does not require external power supply, it can be made in any size and shape, including flexible curvilinear forms, and it is inexpensive. It remains to be determined, which of the potential applications in medical dosimetry (both in vivo and external), or radiation protection would benefit from such selfpowered detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-G-17A-01: Innovative High-Performance PET Imaging System for Preclinical Imaging and Translational Researches

Purpose: To develop a practical and compact preclinical PET with innovative technologies for substantially improved imaging performance required for the advanced imaging applications. Methods: Several key components of detector, readout electronics and data acquisition have been developed and evaluated for achieving leapfrogged imaging performance over a prototype animal PET we had developed. The new detector module consists of an 8×8 array of 1.5×1.5×30 mm{sup 3} LYSO scintillators with each end coupled to a latest 4×4 array of 3×3 mm{sup 2} Silicon Photomultipliers (with ∼0.2 mm insensitive gap between pixels) through a 2.0 mm thick transparent light spreader. Scintillator surface and reflector/coupling were designed and fabricated to reserve air-gap to achieve higher depth-of-interaction (DOI) resolution and other detector performance. Front-end readout electronics with upgraded 16-ch ASIC was newly developed and tested, so as the compact and high density FPGA based data acquisition and transfer system targeting 10M/s coincidence counting rate with low power consumption. The new detector module performance of energy, timing and DOI resolutions with the data acquisition system were evaluated. Initial Na-22 point source image was acquired with 2 rotating detectors to assess the system imaging capability. Results: No insensitive gaps at the detector edge and thus it is capable for tiling to a large-scale detector panel. All 64 crystals inside the detector were clearly separated from a flood-source image. Measured energy, timing, and DOI resolutions are around 17%, 2.7 ns and 1.96 mm (mean value). Point source image is acquired successfully without detector/electronics calibration and data correction. Conclusion: Newly developed advanced detector and readout electronics will be enable achieving targeted scalable and compact PET system in stationary configuration with >15% sensitivity, ∼1.3 mm uniform imaging resolution, and fast acquisition counting rate capability for substantially improved imaging and quantification performance for small animal imaging and image-guided radiotherapy applications. This work was supported by a research award RP120326 from Cancer Prevention and Research Institute of Texas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geography of cretaceous extinctions: Data base development

Data bases built from the source literature are plagued by problems of data quality. Unless the data acquisition is done by experts, working slowly, the data base may contain so much garbage that true signals and patterns cannot be detected. On the other hand, high quality data bases develop so slowly that satisfactory statistical analysis may never be possible due to the small sample sizes. Results of a test are presented of the opposite strategy: rapid data acquisition by non-experts with minimal control on data quality. A published list of 186 species and genera of fossil invertibrates of the latest Cretaceous Age (Maestrichtian) were located through a random search of the paleobiological and geological literature. The geographic location for each faunal list was then transformed electronically to Maestrichtian latitude and longitude and the lists were further digested to identify the genera occurring in each ten-degree, latitude-longitude block. The geographical lists were clustered using the Otsuka similarity coefficient and a standard unweight-pair-group method. The resulting clusters are remarkably consistent geographically, indicating that a strong biogeographic signal is visible despite low-quality data. A further test evaluated the geographic pattern of end-Cretaceaous extinctions. All genera in the data base were compared with Sepkoski's compendium of time ranges of genera to determine which of the reported genera survived the Cretaceous mass extinction. In turn, extinction rates for the ten-degree, latitude-longitude blocks were mapped. The resulting distribution is readily interpretable as a robust pattern of the geography of the mass extinction. The study demonstrates that a low-quality data base, built rapidly, can provide a basis for meaningful analysis of past biotic events.

Raup, D. M.↗

Smart Sensor Node Development, Testing and Implementation for ISHM

A main design criterion for a robust Integrated Systems Health Management (ISHM) system is summed up best by the statement "No data is better than bad data". Traditional data acquisition systems are calibrated in a controlled environment and guaranteed to perform bounded by their tested conditions. To successfully design and implement a real world ISHM system, the data acquisition and signal conditioning needs to function in an uncontrolled environment. Development and testing focuses on a design with the ability to self check in order to extend calibration times, report internal faults and drifts and notify the overall system when the data acquisition is not performing as it should. All of this will be designed in a system that is flexible, requiring little redesign to be deployed on a wide variety of systems. Development progress and testing results will be reported.

Mengers, Timothy↗

An Integrated MEMS Sensor Cluster System for Aerospace Applications

Efforts to reduce viscous drag on airfoils could results in a considerable saving for the operation of flight vehicles including those of space transportation. This reduction of viscous drag effort requires measurement and active control of boundary layer flow property on an airfoil. Measurement of viscous drag of the boundary layer flow over an airfoil with minimal flow disturbance is achievable with newly developed MEMS sensor clusters. These sensor clusters provide information that can be used to actively control actuators to obtain desired flow properties or design a vehicle to satisfy particular boundary layer flow criteria. A series of MEMS sensor clusters has been developed with a data acquisition and control module for local measurements of shear stress, pressure, and temperature on an airfoil. The sensor cluster consists of two shear stress sensors, two pressure sensors, and two temperature sensors on a surface area of 1.24 mm x 1.86 mm. Each sensor is 300 microns square and is placed on a flexible polyimide sheet. The shear stress sensor is a polysilicon hot-film resistor, which is insulated by a vacuum cavity of 200 x 200 x 2 microns. The pressure sensors are silicon piezoresistive type, and the temperature sensors are also hot film polysilicon resistors. The total size of the cluster including sensors and electrical leads is 1 Omm x 1 Omm x 0.1 mm. A typical sensitivity of shear stress sensor is 150 mV/Pascal, the pressure sensors are an absolute type with a measurement range from 9 to 36 psia with 0.8mV/V/psi sensitivity, and the temperature sensors have a measurement resolution of 0.1 degree C. The sensor clusters are interfaced to a data acquisition and control module that consists of two custom ASICs (Application Specific Integrated Circuits) and a micro-controller. The data acquisition and control module transfers data to a host PC that configures and controls a total of three sensor clusters. Functionality of the entire system has been tested in the laboratory, and preliminary test results are presented.

Kahng, Seun↗

Limited-angle effect compensation for respiratory binned cardiac SPECT

Purpose: In cardiac single photon emission computed tomography (SPECT), respiratory-binned study is used to combat the motion blur associated with respiratory motion. However, owing to the variability in respiratory patterns during data acquisition, the acquired data counts can vary significantly both among respiratory bins and among projection angles within individual bins. If not properly accounted for, such variation could lead to artifacts similar to limited-angle effect in image reconstruction. In this work, the authors aim to investigate several reconstruction strategies for compensating the limited-angle effect in respiratory binned data for the purpose of reducing the image artifacts. Methods: The authors first consider a model based correction approach, in which the variation in acquisition time is directly incorporated into the imaging model, such that the data statistics are accurately described among both the projection angles and respiratory bins. Afterward, the authors consider an approximation approach, in which the acquired data are rescaled to accommodate the variation in acquisition time among different projection angles while the imaging model is kept unchanged. In addition, the authors also consider the use of a smoothing prior in reconstruction for suppressing the artifacts associated with limited-angle effect. In our evaluation study, the authors first used Monte Carlo simulated imaging with 4D NCAT phantom wherein the ground truth is known for quantitative comparison. The authors evaluated the accuracy of the reconstructed myocardium using a number of metrics, including regional and overall accuracy of the myocardium, uniformity and spatial resolution of the left ventricle (LV) wall, and detectability of perfusion defect using a channelized Hotelling observer. As a preliminary demonstration, the authors also tested the different approaches on five sets of clinical acquisitions. Results: The quantitative evaluation results show that the three compensation methods could all, but to different extents, reduce the reconstruction artifacts over no compensation. In particular, the model based approach reduced the mean-squared-error of the reconstructed myocardium by as much as 40%. Compared to the approach of data rescaling, the model based approach further improved both the overall and regional accuracy of the myocardium; it also further improved the lesion detectability and the uniformity of the LV wall. When ML reconstruction was used, the model based approach was notably more effective for improving the LV wall; when MAP reconstruction was used, the smoothing prior could reduce the noise level and artifacts with little or no increase in bias, but at the cost of a slight resolution loss of the LV wall. The improvements in image quality by the different compensation methods were also observed in the clinical acquisitions. Conclusions: Compensating for the uneven distribution of acquisition time among both projection angles and respiratory bins can effectively reduce the limited-angle artifacts in respiratory-binned cardiac SPECT reconstruction. Direct incorporation of the time variation into the imaging model together with a smoothing prior in reconstruction can lead to the most improvement in the accuracy of the reconstructed myocardium.

60 APPLIED LIFE SCIENCES↗