Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DYES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Simultaneous three-dimensional velocity and mixing measurements by use of laser Doppler velocimetry and fluorescence probes in a water tunnel

A water tunnel investigation was conducted to demonstrate the capabilities of a laser-based instrument that can measure velocity and fluorescence intensity simultaneously. Fluorescence intensity of an excited fluorescent dye is directly related to concentration level and is used to indicate the extent of mixing in flow. This instrument is a three-dimensional laser Doppler velocimeter (LDV) in combination with a fluorometer for measuring fluorescence intensity variations. This capability allows simultaneous flow measurements of the three orthogonal velocity components and mixing within the same region. Two different flows which were generated by two models were studied: a generic nonaxisymmetric nozzle propulsion simulation model with an auxiliary internal water source that generated a jet flow and an axisymmetric forebody model with a circular sector strake that generated a vortex flow. The off-body flow fields around these models were investigated in the Langley 16- by 24-Inch Water Tunnel. The experimental results were used to calculate 17 quantities that included mean and fluctuating velocities, Reynolds stresses, mean and fluctuating dye fluorescence intensities (proportional to concentration), and fluctuating velocity and dye concentration correlations. An uncertainty analysis was performed to establish confidence levels in the experimental results. In general, uncertainties in mean velocities varied between 1 and 7 percent of free-stream velocity; uncertainties in fluctuating velocities varied between 1 and 5 percent of reference values. The results show characteristics that are unique to each type of flow.

Neuhart, Dan H.↗

Feasibility Study of Velocity and Temperature Measurements of an Arcjet Flow using Laser Resonance Doppler Velocimetric (LRDV) Technique

Thermal Protection System (TPS) materials are used in space vehicles to shield from high heating environment encountered during their atmospheric reentry. Arcjet wind tunnels are used to simulate the flowfield encountered by the spacecrafts, and are used for testing TPS materials. How well these tests simulate the actual heating environment encountered by space vehicles depends on the characteristics of the simulated flow. The flow characterization requires the determination of temperature, concentration, and velocity of the various atomic and molecular species present in the flow. However, determining these parameters requires a complex set of both analytical and experimental procedures. The ability to properly simulate the flight environment is directly related to the accuracy with which these techniques can be used to define the arcjet Laser Resonance Doppler Velocimetric (LRDV) technique can be used to accurately determine the velocity and temperature of a gaseous species. In this technique, the medium is probed with a laser beam that is in resonance with an absorbing transition of the species. The absorption lineshape is Doppler-shifted due to the flow velocity of the species, and the frequency shift is detected as the variation in intensity of the fluorescence emitted by the species. Thus a measurement of the Doppler shift and the width of a spectral line can give both the temperature and the velocity of the flowfield. This summer, our project was to make a feasibility study to set up an experimental arrangement for the laser resonance Doppler velocimetric technique using a ring dye laser. Experiments required troubleshooting, cleaning, testing, and alignment of two lasers and several diagnostics instruments. All instruments and lasers necessary for the project worked well, but the output power of the broadband fundamental dye laser was limited to about 20 mW. This was quite low as compared to that necessary to obtain second harmonic oscillation at 327.49 nm for the LRDV studies. Further optimization of the dye laser optical elements is necessary before it can be used for the experiment, which requires narrowband (about 20 Mhz) laser operation.

Rob, Mohammad A.↗

Simultaneous Luminescence Pressure and Temperature Measurement System for Hypersonic Wind Tunnels

Surface pressures and temperatures are determined from visible emission brightness and green-to-red color ratioing of induced luminescence from a ceramic surface with an organic dye coating. A ceramic-dye matrix of porous silica ceramic with an adsorbed dye is developed for high-temperature pressure sensitivity and stability (up to 150 C). Induced luminescence may be excited using a broad range of incident radiation from visible blue light (488-nm wavelength) to the near ultraviolet (365 nm). Ceramic research models and test samples are fabricated using net-form slip-casting and sintering techniques. Methods of preparation and effects of adsorption film thickness on measurement sensitivity are discussed. With the present 8-bit imaging system a 10% pressure measurement uncertainty from 50 to 760 torr is estimated, with an improvement to 5% from 3 to 1500 torr with a 12-bit imaging system.

Buck, Gregory M.↗

Two Wavelength Ti:sapphire Laser for Ozone DIAL Measurements from Aircraft

Laser remote sensing of ozone from aircraft has proven to be a valuable technique for understanding the distribution and dynamics of ozone in the atmosphere. Presently the differential absorption lidar (DIAL) technique, using dual ND:YAG lasers that are doubled to pump dye lasers which in turn are doubled into the UV for the "on" and "off' line lasers, is used on either the NASA DC-8 or P-3 aircraft. Typically, the laser output for each line is 40-mJ and this is split into two beams, one looking up and the other downward, each beam having about 20-mJ. The residual ND:YAG (1.06 micron) and dye laser energies are also transmitted to obtain information on the atmospheric aerosols. While this system has operated well, there are several system characteristics that make the system less than ideal for aircraft operations. The system, which uses separate "on" and "off" line lasers, is quite large and massive requiring valuable aircraft volume and weight. The dye slowly degrades with time requiring replacement. The laser complexity requires a number of technical people to maintain the system performance. There is also the future interest in deploying an ozone DIAL system in an Unpiloted Atmospheric Vehicle (UAV) which would require a total payload mass of less than 150 kg and power requirement of less than 1500 W. A laser technology has emerged that could potentially provide significant enhancements over the present ozone DIAL system. The flashlamp pumped Ti:sapphire laser system is an emerging technology that could reduce the mass and volume over the present system and also provide a system with fewer conversion steps, reducing system complexity. This paper will discuss preliminary results from a flashlamp-pumped Ti:sapphire laser constructed as a radiation source for a UV DIAL system to measure ozone.

Situ, Wen↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Multipurpose Fiber Injected-micro-spherical LIDAR System

A technological revolution is occurring in the field of fiber lasers. Over the past two years, the level of power has increased from approx. 100 watts to nearly 1 kilowatt. We are developing a novel fiber laser system, which is a satellite-based LIDAR transmitter of multi-lines. The system is made of a hollow fiber filled with micro-spheres doped with lasing materials. Each sphere has its inherent optical cavity, which makes the system a cavity free and in the same time, emits multi-laser lines for simultaneous multi-task operations. The system is also rugged, compact, lightweight, and durable. Our earlier studies on micro-spheres doped with different laser dyes demonstrated the emission of extremely fine laser lines of less than 3 A line-width, which are of interest for spectroscopic applications, sensing, imaging, and optical communications. Individual dye-doped micro-spheres demonstrated a lasing resonance peaks phenomenon in their fluorescence spectra of linear and nonlinear features that do not exist in the bulk dye solutions. Each individual micro-sphere acts as a laser system with inherent cavity, where the fluorescence line suffers multiple internal reflections within the micro-sphere and gains enough energy to become a laser line. Such resonance peaks are dependent on the sphere's morphology, size, shape, and its refractive index. These resonance peaks are named structural resonance, whispering modes or whispering gallery modes, creeping waves, circumferential waves, surfaces modes, and virtual modes. All of these names refer to the same phenomenon of morphology dependent resonance (MDR), which has already been described and predicted precisely by electromagnetic theory and Lorentz-Mie theory since 1908. The resonance peaks become more obvious when the particle size approaches and exceeds the wavelength of the laser used and the relative index of the particle is greater than that of the surrounding medium. Additional information is included in the original extended abstract.

Abdelayem, Hossin↗

Enhanced Microbial Detection Capabilities by a Rapid Portable Instrument

We present data describing a progression of continuing technology development - from expanding the detection capabilities of the current PTS unit to re-outfitting the instrument with a protein microarray increasing the number of detectable compounds. To illustrate the adaptability of the cartridge format, on-orbit operations data from the ISS demonstrate the detection of the fungal cell wall compound beta-glucan using applicable LOCAD-PTS cartridges. LOCAD-PTS is a handheld device consisting of a spectrophotometer, an onboard pumping mechanism, and data storage capabilities. A suite of interchangeable cartridges lined with four distinct capillaries allow a hydrated sample to mix with necessary reagents in the channels before being pumped to the optical well for spectrophotometric analysis. The reagents housed in one type of cartridge trigger a reaction based on the Limulus Amebocyte Lysate (LAL) assay, which results in the release of paranitroaniline dye. The dye is measured using a 395 nm filter. The LAL assay detects the Gram-negative bacterial cell wall molecule, endotoxin or lipopolysaccharide (LPS). The more dye released, the greater the concentration of endotoxin in the sample. Sampling, quantitative analysis, and data retrieval require less than 20 minutes. This is significantly faster than standard culture-based methods, which require at least a 24 hour incubation period.Using modified cartridges, we demonstrate the detection of Gram negative bacteria with protein microarray technology. Additionally, we provide data from multiple field tests where both standard and advanced PTS technologies were used. These tests investigate the transfer of target microbial molecules from one surface to another. Collectively, these data demonstrate that the new cartridges expand the number of compounds detected by LOCAD-PTS, while maintaining the rapid, in situ analysis characteristic of the instrument. The unit provides relevant data for verifying sterile sample collection protocols, which are critical for conducting accurate scientific experiments during future missions to the Moon and Mars.

Morris, Heather↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Flight Testing of the Forward Osmosis Bag for Water Recovery on STS-135

The Forward Osmosis Bag (FOB) is a personal water purification device for recovery of potable liquid from almost any non-potable water source. The FOB experiment was flown as a sortie mission on STS-135/ULF7 using flight-certified materials and a design based on the X-Pack(TradeMark) from Hydration Technology Innovations (Albany, OR). The primary objective was to validate the technology for use under microgravity conditions. The FOB utilizes a difference in solute concentration across a selectively permeable membrane to draw water molecules from the non-potable water while rejecting most chemical and all microbial contaminants contained within. Six FOB devices were tested on STS-135 for their ability to produce a potable liquid permeate from a feed solution containing 500 mL potassium chloride (15 g/L) amended with 0.1% methyl blue dye (w:v) tracer against an osmotic gradient created by addition of 60 mL of concentrate containing the osmolytes fructose and glucose, and 0.01% sodium fluorescein (w:v) tracer. Three FOB devices were physically mixed by hand for 2 minutes by a crewmember after loading to augment membrane wetting for comparison with three unmixed FOB devices. Hydraulic flux rate and rejection of salt and dye in microgravity were determined from a 60-mL sample collected by the crew on orbit after 6 hours. Post-flight analysis of samples collected on orbit demonstrated that the Forward Osmosis Bag achieved expected design specifications in microgravity. The hydraulic flux rate of water across the membrane was reduced approximately 50% in microgravity relative to ground controls that generated an average of 50 mL per hour using the same water and osmolyte solutions. The membrane rejected both potassium and chloride at >92% and methyl blue dye at >99.9%. Physical mixing of the FOB during water recovery did not have any significant effect on either flux rate or rejection of solutes from the water solution. The absence of buoyancy-driven convection in microgravity suggests that mass transport was dominated by diffusion, slowing the rate of permeate production across the membrane. It is possible that a predicted reduction in concentration polarization at the membrane surface that may have acted to increase the rate of permeate production in microgravity was negligible under the described test conditions.

Roberts, Michael S.↗

Fluorescence-Doped Particles for Simultaneous Temperature and Velocity Imaging

Polystyrene latex microspheres (PSLs) have been used for particle image velocimetry (PIV) and laser Doppler velocimetry (LDV) measurements for several decades. With advances in laser technologies, instrumentation, and data processing, the capability to collect more information about fluid flow beyond velocity is possible using new seed materials. To provide additional measurement capability, PSLs were synthesized with temperature-sensitive fluorescent dyes incorporated within the particle. These multifunctional PSLs would have the greatest impact if they could be used in large scale facilities with minimal modification to the facilities or the existing instrumentation. Consequently, several potential dyes were identified that were amenable to existing laser systems currently utilized in wind tunnels at NASA Langley Research Center as well as other wind and fluid (water) tunnels. PSLs incorporated with Rhodamine B, dichlorofluorescein (DCF, also known as fluorescein 548 or fluorescein 27) and other dyes were synthesized and characterized for morphology and spectral properties. The resulting particles were demonstrated to exhibit fluorescent emission, which would enable determination of both fluid velocity and temperature. They also would allow near-wall velocity measurements whereas laser scatter from surfaces currently prevents near-wall measurements using undoped seed materials. Preliminary results in a wind tunnel facility located at Virginia Polytechnic Institute and State University (Virginia Tech) have verified fluorescent signal detection and temperature sensitivity of fluorophore-doped PSLs.

Danehy, Paul M.↗

Late Effects of Heavy Ion Irradiation on Ex Vivo Osteoblastogenesis and Cancellous Bone Microarchitecture

Prolonged spaceflight causes degeneration of skeletal tissue with incomplete recovery even after return to Earth. We hypothesize that heavy ion irradiation, a component of Galactic Cosmic Radiation, damages osteoblast progenitors and may contribute to bone loss during long duration space travel beyond the protection of the Earth's magnetosphere. Male, 16 week old C57BL6/J mice were exposed to high LET (56 Fe, 600MeV) radiation using either low (5 or 10cGy) or high (50 or 200cGy) doses at the NASA Space Radiation Lab and were euthanized 3 - 4, 7, or 35 days later. Bone structure was quantified by microcomputed tomography (6.8 micron pixel size) and marrow cell redox assessed using membrane permeable, free radical sensitive fluorogenic dyes. To assess osteoblastogenesis, adherent marrow cells were cultured ex vivo, then mineralized nodule formation quantified by imaging and gene expression analyzed by RT PCR. Interestingly, 3 - 4 days post exposure, fluorogenic dyes that reflect cytoplasmic generation of reactive nitrogen/oxygen species (DAF FM Diacetate or CM H2DCFDA) revealed irradiation (50cGy) reduced free radical generation (20-45%) compared to sham irradiated controls. Alternatively, use of a dye showing relative specificity for mitochondrial superoxide generation (MitoSOX) revealed an 88% increase compared to controls. One week after exposure, reactive oxygen/nitrogen levels remained lower(24%) relative to sham irradiated controls. After one month, high dose irradiation (200 cGy) caused an 86% decrement in ex vivo nodule formation and a 16-31% decrement in bone volume to total volume and trabecular number (50, 200cGy) compared to controls. High dose irradiation (200cGy) up regulated expression of a late osteoblast marker (BGLAP) and select genes related to oxidative metabolism (Catalase) and DNA damage repair (Gadd45). In contrast, lower doses (5, 10cGy) did not affect bone structure or ex vivo nodule formation, but did down regulate iNOS by 0.54 - 0.58 fold. Thus, both low and high doses of heavy ion irradiation cause time dependent, adaptive changes in redox state within marrow cells but only high doses (50, 200cGy) inhibit osteoblastogenesis and cause cancellous bone loss. We conclude space radiation has the potential to cause persistent damage to bone marrow derived stem and progenitor cells for osteoblasts despite adaptive changes in cellular redox state.

Tran, Luan Hoang↗

Late Effects of Heavy-Ion Irradiation on Ex Vivo Osteoblastogenesis and Cancellous Bone Microarchitecture

Prolonged spaceflight causes degeneration of skeletal tissue with incomplete recovery even after return to Earth. We hypothesize that heavy-ion irradiation, a component of Galactic Cosmic Radiation, damages osteoblast progenitors and may contribute to bone loss during long duration space travel beyond the protection of the Earth's magnetosphere. Male, 16 week-old C57BL6/J mice were exposed to high-LET (56-Fe, 600MeV) radiation using either low (5 or 10cGy) or high (50 or 200cGy) doses at the NASA Space Radiation Lab and were euthanized 3-4, 7, or 35 days later. Bone structure was quantified by microcomputed tomography (6.8 μm pixel size) and marrow cell redox assessed using membrane permeable, free radical-sensitive fluorogenic dyes. To assess osteoblastogenesis, adherent marrow cells were cultured ex vivo, then mineralized nodule formation quantified by imaging and gene expression analyzed by RT-PCR. Interestingly, 3-4 days post-exposure, fluorogenic dyes that reflect cytoplasmic generation of reactive nitrogen/oxygen species (DAF-FM Diacetate or CM-H2DCFDA) revealed irradiation (50cGy) reduced free radical generation (20-45%) compared to sham-irradiated controls. Alternatively, use of a dye showing relative specificity for mitochondrial superoxide generation (MitoSOX) revealed an 88% increase compared to controls. One week after exposure, reactive oxygen/nitrogen levels remained lower (24%) relative to sham-irradiated controls. After one month, high dose irradiation (200 cGy) caused an 86% decrement in ex vivo nodule formation and a 16-31% decrement in bone volume to total volume and trabecular number (50, 200cGy) compared to controls. High dose irradiation (200cGy) up-regulated expression of a late osteoblast marker (BGLAP) and select genes related to oxidative metabolism (Catalase) and DNA damage repair (Gadd45). In contrast, lower doses (5, 10cGy) did not affect bone structure or ex vivo nodule formation, but did down-regulate iNOS by 0.54-0.58 fold. Thus, both low- and high-doses of heavy-ion irradiation cause time-dependent, adaptive changes in redox state within marrow cells but only high doses (50, 200cGy) inhibit osteoblastogenesis and cause cancellous bone loss. We conclude space radiation has the potential to cause persistent damage to bone marrow-derived stem and progenitor cells for osteoblasts despite adaptive changes in cellular redox state.

LATE EFFECTS OF HEAVY-ION IRRADIATION↗

Flow cytometric detection method for DNA samples

Disclosed herein are two methods for rapid multiplex analysis to determine the presence and identity of target DNA sequences within a DNA sample. Both methods use reporting DNA sequences, e.g., modified conventional Taqman.RTM. probes, to combine multiplex PCR amplification with microsphere-based hybridization using flow cytometry means of detection. Real-time PCR detection can also be incorporated. The first method uses a cyanine dye, such as, Cy3.TM., as the reporter linked to the 5' end of a reporting DNA sequence. The second method positions a reporter dye, e.g., FAM.TM. on the 3' end of the reporting DNA sequence and a quencher dye, e.g., TAMRA.TM., on the 5' end.

59 BASIC BIOLOGICAL SCIENCES↗

Surface plasmon-mediated energy transfer of electrically-pumped excitons

An electrically pumped light emitting device emits a light when powered by a power source. The light emitting device includes a first electrode, a second electrode including an outer surface, and at least one active organic semiconductor disposed between the first and second electrodes. The device also includes a dye adjacent the outer surface of the second electrode such that the second electrode is disposed between the dye and the active organic semiconductor. A voltage applied by the power source across the first and second electrodes causes energy to couple from decaying dipoles into surface plasmon polariton modes, which then evanescently couple to the dye to cause the light to be emitted.

30 DIRECT ENERGY CONVERSION↗

Evaluation of TiO{sub 2} and TiO{sub 2}/Au nanoparticles as a Potential Radiosensitizers by Decomposition of Methylene Blue

Nanomaterials are constantly used in several applications of science and engineering. Nanoparticles are currently utilized in computer circuits, clothes, luminescent devices, catalysis, medicine, among many others uses. In the clinical field nanomaterials have become an innovative alternative for early diagnosis and treatment of a significant number of medical conditions. Nanoparticles can be utilized in applications ranging from contrast agents for imaging purposes to carriers for drug delivery in cancerous tumors. The use of nanoparticles made of high atomic number elements as noble metals, is becoming an attractive approach for enhancing the radiation dose delivered to a tissue during radiation therapy. The enhancement effect that makes the cells more sensitive to radiation is known as radiosensitization. Materials such as gold (Au) and titanium dioxide (TiO{sub 2}) at the nanoscale have become promising radiosensitizers. When TiO{sub 2} is irradiated with high energy photons, electron-holes are created within the material. This species interacts with surrounding medium generating reactive oxygen species (ROS). ROS create a toxic environment for cancerous cells, ultimately causing their death. On the other hand gold has a different interaction with ionizing radiation. Upon radiation, gold releases a spray of secondary products such as photoelectrons, auger electrons, and characteristic X-rays. The energy created by the escaping electrons leads to DNA strands breaks in the cells causing their death. Therefore, if these nanoparticles are initially accumulated in the tissue to be treated, the dose delivered during radiation therapy is amplified. This represents a synergistic approach to enhance radiation therapy while substantially reducing side effects. Radiosensitization by nanoparticles often depends on their particle size, morphology and synthesis route. The most commonly used methods to synthesize metallic nanoparticles such as gold involves chemical reduction of a metal precursor. In this case, reducing agents are used in order to transform the metallic ions to metal atoms that will subsequently coalesce and grow to form the nanoparticles . Nevertheless there are alternative methods that do not require a chemical reducing agent. Radiation synthesis is one of those processes. The interaction of ionizing radiation with an aqueous solution containing a metal precursor, leads to a phenomena known as radiolysis of water. Radiolysis of water produces chemical species such as solvated electrons (e{sup -}{sub aq}), and hydrogen atoms (H{sup +}). These species are strong reducing agents that bring the metal ions existing in solution into stable metal atoms that will form nanoparticles. Radiation synthesis is a novel method that offers significant advantages over conventional approaches such as wet chemistry routes. In this approach, no further chemical reducing agents are needed, thus it does not generate byproducts that may affect the nanoparticles properties. This is particularly important in medical applications. Furthermore, this technique is designed to work at room temperature and under atmospheric pressures. Nonetheless the most outstanding feature of radiation synthesis is the possibility to control the particle size and size distribution. This route allows for narrow particle size distributions with size ranging from 2 to 30 nm. Furthermore, the availability of different ionizing radiation producing devices such as synchrotrons, X-ray irradiators, and gamma irradiators enables the possibility of manufacturing nanomaterials under various conditions. In this work, Au nanoparticles were deposited onto TiO{sub 2} using the radiation synthesis method. In addition, the radiosensitization characteristics of TiO{sub 2} and TiO{sub 2}/Au nanoparticles were evaluated through the decomposition of the organic dye Methylene Blue (MB). In order to analyze the degradation of the dye the TiO{sub 2} and TiO{sub 2}/Au nanoparticles were placed in an aqueous solution along with MB and subjected to X-ray irradiation. The samples were irradiated for 30 and 60 minutes. The degradation of the MB after irradiation in the presence and absence of the nanomaterials was measured by UV-Vis spectroscopy following the decrease in the absorbance of the dye at 664 nm. (authors)

36 MATERIALS SCIENCE↗

Malachite green based radio-chromic compounds and radiation sensing systems incorporating the compounds

Derivatized malachite green leuco dyes for use in radio-chromic systems are described. The dyes have the following structure: in which Ar is a substituted phenyl or thiophene ring in which at least one substitution of the Ar ring is not ortho to the bond between the ring and the linking carbon, and in which R 1 , R 2 , R 3 , and R 4 are independently selected from methyl, alkyl, or alkyl halide. The systems include the dyes in conjunction with an activator, e.g., a halogenated activator, and a carrier, e.g., a fluid carrier or an encapsulating polymeric matrix.

Washington, II, Aaron L.↗

Microbundles of zinc oxide nanorods: Assembly in ionic liquid [EMIM]{sup +}[BF{sub 4}]{sup -}, photoluminescence and photocatalytic properties

A simple, efficient and low-temperature approach for the assembly of hierarchical Zinc oxide (ZnO) microstructures in ionic liquid [EMIM]{sup +}[BF{sub 4}]{sup -} is reported. The as-obtained ZnO superstructures are composed of microbundles of nanorods from the center points, with the diameter and length in the range of 100-150 nm and 2-4 {mu}m, which have been characterized by X-ray diffraction, scanning and transmission electron microscopy, and photoluminescence spectroscopy. The ZnO microstructures exhibit significant defect-related green-yellow emission and high photodegradation of dye Methyl Orange (5x10{sup -5} mol/L) under UV excitation within 80 min. -- Graphical abstract: Easy formation of microbundles of ZnO nanorods were accomplished in low temperature with [EMIM]{sup +}[BF{sub 4}]{sup -} (1-ethyl-3-methylimidazolium tetrafluoroborate) ionic liquid, which exhibit significant green-yellow photoluminescence property and high photodegradation of Methyl Orange dye. Display Omitted Research highlights: {yields} Ionic liquid assisted solid-state route was introduced into synthesis of ZnO nanorods. {yields} The distinctive microbundles ZnO nanorod assembles was evidenced by SEM and TEM. {yields} ZnO nano-material exhibited high efficiency in photodegradation of Methyl Orange.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Thermodynamical and structural insights of orange II adsorption by Mg{sub R}AlNO{sub 3} layered double hydroxides

[Mg{sub 1-x} Al{sub x}(OH){sub 2}][(NO{sub 3}){sub x}, nH{sub 2}O] Layered Double Hydroxide (LDH) sorbents with variable Mg/Al molar (R=(1-x)/x) ratios were investigated for adsorption of azo dye, orange II (OII) at various pH and temperature conditions. Mg{sub 2}AlNO{sub 3} displays the highest adsorption capacity with 3.611 mmol of OII per gram of Mg{sub 2}AlNO{sub 3} at 40 {sup o}C. Adsorption isotherms have been fitted using the Langmuir model and free energy of adsorption ({Delta}G{sup o}), enthalpy ({Delta}H{sup o}) and entropy ({Delta}S{sup o}) were calculated. The experimental values for {Delta}G{sup o} in temperature range between 10 and 40 {sup o}C were found to be negative indicating that a spontaneous process occurred. Positive calculated enthalpy values, characteristic of an endothermic process were found. Characterization of solids (PXRD, FTIR, UV-vis, TGA/DTA, adsorption isotherm BET analysis, SEM and Zetametry) before and after adsorption showed that adsorption proceeds in two steps. First, adsorption occurs at the LDH surface, followed by intercalation via anion exchange. -- Graphical Abstract: Structural and thermodynamical insight of adsorption/Intercalation of OII in Mg{sub R}Al LDH Display Omitted Highlights: {yields} The nitrate containing hydrotalcite-like compounds (Mg{sub R}AlNO{sub 3} LDH) were prepared by the coprecipitation method. {yields} Adsorption of anionic orange dye(OII) is studied on LDHs at different temperatures. {yields} The adsorption process is well described by the Langmuir isotherm model. {yields} Mg{sub 2}AlNO{sub 3} displays the highest adsorption capacity with 3.611 mmol of OII per gram of Mg{sub 2}AlNO{sub 3} at 40 {sup o}C. {yields} Adsorption process does not occur on the surface of the LDH only but an intercalation process is also occurring concomitantly according to the thermodynamical values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗