Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cycle Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Molecular Adsorber Coating

A document discusses a zeolite-based sprayable molecular adsorber coating that has been developed to alleviate the size and weight issues of current ceramic puck-based technology, while providing a configuration that more projects can use to protect against degradation from outgassed materials within a spacecraft, particularly contamination-sensitive instruments. This coating system demonstrates five times the adsorption capacity of previously developed adsorber coating slurries. The molecular adsorber formulation was developed and refined, and a procedure for spray application was developed. Samples were spray-coated and tested for capacity, thermal optical/radiative properties, coating adhesion, and thermal cycling. Work performed during this study indicates that the molecular adsorber formulation can be applied to aluminum, stainless steel, or other metal substrates that can accept silicate-based coatings. The coating can also function as a thermal- control coating. This adsorber will dramatically reduce the mass and volume restrictions, and is less expensive than the currently used molecular adsorber puck design.

Straka, Sharon↗

Improved Wide Operating Temperature Range of LiNiCoAiO2-based Li-ion Cells with Methyl Propionate-based Electrolytes

Demonstration of wide operating temperature range Li-ion electrolytes Methyl propionate-based wide operating temperature range electrolytes were demonstrated to provide dramatic improvement of the low temperature capability of Quallion prototype Li-ion cells (MCMB-LiNiCoAlO2). Some formulations were observed to deliver over 60% of the room temperature capacity using a 5C rate at - 40oC !! Represents over a 4-fold improvement over the baseline electrolyte system. Demonstrated operational capability of a number of systems over a wide temperature range (-40 to +70 C) Demonstrated reasonably good long term cycle life performance at high temperature (i.e., at +40deg and +50 C) A number of formulations containing electrolytes additives (i.e., FEC, VC, LiBOB, and lithium oxalate) have been shown to have enhanced lithium kinetics at low temperature and promising high temperature resilience. Demonstrated good performance in larger capacity (12 Ah) Quallion Li-ion cells with methyl propionate-based electrolytes. Current efforts focused upon performing life studies and the impact upon low temperature capability.

Li-ion electrolytes↗

Contributions of Astronauts Aerobic Exercise Intensity and Time on Change in VO2peak during Spaceflight

There is considerable variability among astronauts with respect to changes in maximal aerobic capacity (VO2peak) during International Space Station (ISS) missions, ranging from a 5% increase to 30% decline. Individual differences may be due to in-flight aerobic exercise time and intensity. PURPOSE: To evaluate the effects of in-flight aerobic exercise time and intensity on change in VO2peak during ISS missions. METHODS: Astronauts (N=11) performed peak cycle tests approx 60 days before flight (L-60), on flight day (FD) approx 14, and every approx 30 days thereafter. Metabolic gas analysis and heart rate (HR) were measured continuously during the test using the portable pulmonary function system. HR and duration of each in-flight cycle ergometer and treadmill (TM) session were recorded and averaged in time segments corresponding to each peak test. Mixed effects linear regression with exercise mode (TM or cycle) as a categorical variable was used to assess the contributions of exercise intensity (%time >70% peak HR or %time >90% peak HR) and time (min/wk), adjusted for body weight, on %change in VO2peak during the mission, and incorporating the repeated-measures experimental design. RESULTS: 110 observations were included in the model (4-6 peak cycle tests per astronaut, 2 exercise devices). VO2peak was reduced from preflight throughout the mission (FD14: 13+/-13% and FD 105: 8+/-10%). Exercise intensity (%peak HR: FD14=66+/-14; FD105=75+/-8) and time (min/wk: FD14=82+/-46; FD105=158+/-40) increased during flight. The models showed main effects for exercise time and intensity with no interactions between time, intensity, and device (70% peak HR: time [z-score=2.39; P=0.017], intensity [z-score=3.51; P=0.000]; 90% peak HR: time [zscore= 3.31; P=0.001], intensity [z-score=2.24; P=0.025]). CONCLUSION: Exercise time and intensity independently contribute to %change in VO2peak during ISS missions, indicating that there are minimal values for exercise time and intensity required to maintain VO2peak. As the FD105 average exercise intensity and time did not prevent a decline in VO2peak from preflight, astronauts' exercise prescriptions should target at least 160 min of weekly aerobic exercise at an average above 75% peak HR with increased time at intensities above 90% of peak HR starting early in the mission.

Downs, Meghan E.↗

Evaluation of RTM370 Polyimide Composites by Resin Film Infusion (RFI)

RTM370 imide oligomer based on 2,3,3',4'-biphenyl dianhydride (a-BPDA), 3,4'-oxydianiline (3,4'-ODA) and terminated with the 4-phenylethynylphthalic (PEPA) endcap has been shown to exhibit a low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h and a high cured glass-transition temperature (Tg) of 370 C. RTM370 resin has been successfully infused into fiberglass-stitched T650-35 carbon-fabric preforms (ranged from 3- to 6-mm thick) by resin film infusion (RFI). The resulting composite panels were inspected by ultrasonic C-scan and by photomicrographs before and after post-curing as a quality control. Mechanical tests such as unnotched compression (UNC), open-hole compression (OHC), and short-beam shear strength (SBS) at ambient and elevated temperatures were performed before and after isothermal aging at 288 C for 1000 h to assess high-temperature performance. Thermal cycling of RTM370 stitched composites was also conducted from -54 C to 288 C for up to 1600 cycles to evaluate the microcrack resistance of RTM370 polyimide composites fabricated by RFI.

Polyimide↗

Nano-Launcher Technologies, Approaches, and Life Cycle Assessment

Assist in understanding NASA technology and investment approaches, and other driving factors, necessary for enabling dedicated nano-launchers by industry at a cost and flight rate that (1) could support and be supported by an emerging nano-satellite market and (2) would benefit NASAs needs. Develop life-cycle cost, performance and other NASA analysis tools or models required to understand issues, drivers and challenges.

launch costs↗

Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

radiometry↗

The 2013 FLEX-US Airborne Campaign at the Parker Tract Loblolly Pine Plantation in North Carolina, USA

The first European Space Agency (ESA) and NASA collaboration in an airborne campaign to support ESA's FLuorescence EXplorer (FLEX) mission was conducted in North Carolina, USA during September-October 2013 (FLEX-US 2013) at the Parker Tract Loblolly Pine (LP) Plantation (Plymouth, NC, USA). This campaign combined two unique airborne instrument packages to obtain simultaneous observations of solar-induced fluorescence (SIF), LiDAR-based canopy structural information, visible through shortwave infrared (VSWIR) reflectance spectra, and surface temperature, to advance vegetation studies of carbon cycle dynamics and ecosystem health. We obtained statistically significant results for fluorescence, canopy temperature, and tower fluxes from data collected at four times of day over two consecutive autumn days across an age class chronosequence. Both the red fluorescence (F685) and far-red fluorescence (F740) radiances had highest values at mid-day, but their fluorescence yields exhibited different diurnal responses across LP age classes. The diurnal trends for F685 varied with forest canopy temperature difference (canopy minus air), having a stronger daily amplitude change for young vs. old canopies. The Photochemical Reflectance Index (PRI) was positively correlated with this temperature variable over the diurnal cycle. Tower measurements from mature loblolly stand showed the red/far-red fluorescence ratio was linearly related to canopy light use efficiency (LUE) over the diurnal cycle, but performed even better for the combined morning/afternoon (without midday) observations. This study demonstrates the importance of diurnal observations for interpretation of fluorescence dynamics, the need for red fluorescence to understand canopy physiological processes, and the benefits of combining fluorescence, reflectance, and structure information to clarify canopy function versus structure characteristics for a coniferous forest.

chlorophyll fluorescence; diurnal responses; red S↗

Additive Manufacturing of NASA HR-1 Material for Liquid Rocket Engine Component Applications

NASA HR-1 is a high-strength Fe-Ni superalloy designed to resist high pressure, hydrogen environment embrittlement, oxidation, and corrosion. NASA HR-1 was originally developed at NASA in the 1990’s and derived from JBK-75 to increase strength and ductility in high-pressure hydrogen environments. The NASA HR-1 chemistry was formulated to meet requirements for liquid rocket engine applications, specifically components used in a high-pressure hydrogen environment. Recent developments using additive manufacturing (AM) have made this material an attractive option for channel-cooled nozzles under the Rapid Analysis and Manufacturing Propulsion Technology (RAMPT) program and other liquid rocket engine component applications. The RAMPT program has baselined to fully evolve and characterize NASA HR-1 material. NASA HR-1 meets materials requirements for liquid rocket engine components, including good hydrogen resistance, high conductivity, good low cycle fatigue performance, and high elongation and strength for channel-cooled nozzles in high heat flux environments. Initial development and characterization has been completed using blown powder Directed Energy Deposition (DED) and Laser Powder Bed Fusion (L-PBF) additive manufacturing techniques to develop material test samples and nozzle hardware. NASA HR-1 powder has been sourced and characterized from several powder suppliers, and a series of development and hardware samples completed fabrication using DED and L-PBF. Characterization of the material has included heat treatment development, metallography, chemistry evaluations, mechanical testing, measurement of thermophysical properties, and fabrication of relevant nozzle hardware to demonstrate feasibility. This paper presents results from the process and early materials development and provide future development work including hardware fabrication.

Katsarelis, Colton↗

Challenges, Considerations, and Opportunities for Exercise and Medical Accommodation Inside a Small Pressurized Rover

Pressurized Rovers (PR) can enable crew to explore away from a lander or surface habitat at distances not possible on foot or even in unpressurized rovers. Sustaining crew for multiple days, they can rove for weeks, independent of other surface elements. Because these are essentially mobile habitats, it is critical that they provide sufficient volume to accommodate the exercise and medical systems to maintain human health in remote, low gravity environments such as the Moon and Mars. This is an area of extensive unknowns as requirements have not yet been developed for exercise or medical systems in pressurized rovers. Yet they must be considered in vehicle sizing studies as they are significant volume drivers, requiring allocation for stowed and deployed hardware inside the rover cabin. Previously flown spacecraft have allocated varying amounts of volume based on the expected crew mission and the state of the art in these systems. NASA-STD-3001 provides high-level requirements for standards of medical care and exercise capabilities. Crew injuries are possible both inside the cabin and on extravehicular activities (EVA), therefore requiring medical capability. Exercise countermeasures are needed to counteract the debilitating effects of lowered gravity. This may include both reconditioning following a lengthy microgravity transit as well as ongoing countermeasures against the effect of low surface gravity. The NASA reference concept for the PR dates back to the Constellation Program and prototypes have been extensively tested in NASA’s Desert Research and Technology Studies (DRATS) program as well as at the NASA Johnson Space Center. The PR cabin is designed to accommodate two crewmembers and is subdivided into a forward cockpit area and a main body for crew habitation. EVAs are accomplished by transitioning through suit ports in the aft bulkhead into spacesuits. While no exercise devices have been developed for the PR, some have been prototyped and demonstrated in DRATS analog missions. A cycle ergometer performed reasonably well in DRATS testing as an aerobic exercise device and recent analysis work has theorized that a combination aerobic and resistive device could be packaged into a form factor similar to the DRATS ergometer. It is therefore suitable for use as an initial volumetric placeholder. No sensorimotor devices have been considered for the PR to aid in adaptation to surface gravity. However, there are commercially available treadmills that at minimum represent examples of the type of exercise system that could potentially be used for such a purpose. A combination of field test data, analysis, and CAD modeling will be used to perform a first pass assessment of whether these exercise devices can be stowed and deployed within the PR. Medical inventories from the International Space Station will be used as a volume placeholder for the PR medical system. A configuration will be discussed for medical deployment, including positioning of caregiver, patient, and medical equipment / supplies.

Pressurized Rover↗

Enhancing In-Flight Structural Health Monitoring of Vertical Lift Vehicles Operating in an Urban Environment

In-situ airframe sensors have long been considered a potential solution for structural health monitoring that could change the design, certification, operation and maintenance paradigms of flight vehicles. In this approach, large networks of sensors covering the entire, or most of, an airframe throughout its operational lifetime would support real-time decisions on airworthiness and obviate the need to overbuild components or perform multiple cycles of structural qualification testing and inspections. This concept would go beyond the current practice of placing select sensors in strategic locations or relying on such sensors only during airframe qualification flights and inspections. For vehicles in the emerging urban air mobility space, reducing weight associated with overbuilds and shortening down-time associated with inspections are critical for improving safety and affordability. In practice, the wide-scale use of in-situ sensors as primary assurance for structural health has not been demonstrated to be feasible or the best solution. A sensor integration testbed was developed as a platform to evaluate the potential of multiple sensor types to enable decision making on airworthiness. We report on the initial runs of this testbed with multiple sensors attached to a common test article. Metal foil strain gauges, eddy current, fiber optic, guided wave (acoustic emission and ultrasonic)and carbon nanotube roving sensors were affixed to the test article. Baseline as well as post damage initiation and fatiguing data are presented and discussed. Despite the relative simplicity of the test article, the interpretation of the as-captured test data was generally not conclusive or did not have wide enough coverage. This result emphasizes the challenges and current limitations both in testing and the practical broad application of embedded sensors as the determinative elements in critical decision making on wide-scale structural health.

Vertical Lift Vehicles↗

Enhancing In-Flight Structural Health Monitoring of Vertical Lift Vehicles Operating in an Urban Environment

In-situ airframe sensors have long been considered a potential solution for structural health monitoring that could change the design, certification, operation, and maintenance paradigms of flight vehicles. In this approach, large networks of sensors covering the entire, or most of, an airframe throughout its operational lifetime would support real-time decisions on airworthiness and obviate the need to overbuild components or perform multiple cycles of structural qualification testing and inspections. This concept would go beyond the current practice of placing select sensors in strategic locations or relying on such sensors only during airframe qualification flights and inspections. For vehicles in the emerging urban air mobility space, reducing weight associated with overbuilds and shortening down-time associated with inspections are critical for improving safety and affordability. In practice, the wide-scale use of in-situ sensors as primary assurance for structural health has not been demonstrated to be feasible or the best solution. A sensor integration testbed was developed as a platform to evaluate the potential of multiple sensor types to enable decision making on airworthiness. We report on the initial runs of this testbed with multiple sensors attached to a common test article. Metal foil strain gauges, eddy current, fiber optic, guided wave (acoustic emission and ultrasonic) and carbon nanotube roving sensors were affixed to the test article. Baseline as well as post damage initiation and fatiguing data are presented and discussed. Despite the relative simplicity of the test article, the interpretation of the as-captured test data was generally not conclusive or did not have wide enough coverage. This result emphasizes the challenges and current limitations both in testing and the practical broad application of embedded sensors as the determinative elements in critical decision making on wide-scale structural health.

Vertical Lift Vehicles↗

Parametric Subsonic Engine Model

Creating a rubberized engine model and exploring different approaches for converging over multiple design points.

Aeronautics↗

Energy Efficiency and Environmental Impact Analyses of Supermarket Refrigeration Systems

This paper presents energy and life cycle climate performance (LCCP) analyses of a variety of supermarket refrigeration systems to identify designs that exhibit low environmental impact and high energy efficiency. EnergyPlus was used to model refrigeration systems in a variety of climate zones across the United States. The refrigeration systems that were modeled include the traditional multiplex DX system, cascade systems with secondary loops and the transcritical CO2 system. Furthermore, a variety of refrigerants were investigated, including R-32, R-134a, R-404A, R-1234yf, R-717, and R-744. LCCP analysis was used to determine the direct and indirect carbon dioxide emissions resulting from the operation of the various refrigeration systems over their lifetimes. Our analysis revealed that high-efficiency supermarket refrigeration systems may result in up to 44% less energy consumption and 78% reduced carbon dioxide emissions compared to the baseline multiplex DX system. This is an encouraging result for legislators, policy makers and supermarket owners to select low emission, high-efficiency commercial refrigeration system designs for future retrofit and new projects.

Fricke, Brian A↗

Development of Versatile Compressor Modeling using Approximation Techniques for Alternative Refrigerants Evaluation

Refrigerants are the life-blood of vapor compression systems that are widely used in Heating, Ventilation, Air-Conditioning, and Refrigeration (HVAC&R) applications. The HVAC&R community is currently transitioning from main-stream refrigerants that have high Global Warming Potential (GWP) to alternative lower-GWP refrigerants. During this transition, it is important to account for the life cycle climate performance of alternative refrigerants since their performance will be different than that of higher-GWP refrigerants. This requires the evaluation of the system performance with the new refrigerants. Unfortunately, it is extremely difficult to predict the realistic performance of new alternative refrigerants without experimental validation. One of the main challenges in this regard is modeling the compressor performance with high fidelity due to the complex interaction of operating parameters, geometry, boundary conditions, and fluid properties. High fidelity compressor models are computationally expensive and require significant pre-processing to evaluate the performance of alternative refrigerants. This paper presents a new approach to modeling compressor performance when alternative refrigerants are used. The new modeling concept relies on using existing compressor performance to create an approximate model that captures the dependence of compressor performance on key operating parameters and fluid properties. The model can be built using a myriad of approximation techniques. This paper focuses on Kriging-based techniques to develop higher fidelity approximate compressor models. Baseline and at least one alternative refrigerant performance data are used to build the model. The model accuracy was evaluated by comparing the model results with compressor performance data using other refrigerants. Preliminary results show that the approximate model can predict the compressor mass flow rate and power consumption within 5%.

Approximation↗

An Evaluation of the Environmental Impact of Different Commercial Supermarket Refrigeration Systems Using Low Global Warming Potential Refrigerants

Commercial refrigeration systems consumed 1.21 Quads of primary energy in 2010 and are known to be a major source for refrigerant charge leakage into the environment. Thus, it is important to study the environmental impact of commercial supermarket refrigeration systems and improve their design to minimize any adverse impacts. The system s Life Cycle Climate Performance (LCCP) was presented as a comprehensive metric with the aim of calculating the equivalent mass of carbon dioxide released into the atmosphere throughout its lifetime, from construction to operation and destruction. In this paper, an open source tool for the evaluation of the LCCP of different air-conditioning and refrigeration systems is presented and used to compare the environmental impact of a typical multiplex direct expansion (DX) supermarket refrigeration systems based on three different refrigerants as follows: two hydrofluorocarbon (HFC) refrigerants (R-404A, and R-407F), and a low global warming potential (GWP) refrigerant (N-40). The comparison is performed in 8 US cities representing different climates. The hourly energy consumption of the refrigeration system, required for the calculation of the indirect emissions, is calculated using a widely used building energy modeling tool (EnergyPlus). A sensitivity analysis is performed to determine the impact of system charge and power plant emission factor on the LCCP results. Finally, we performed an uncertainty analysis to determine the uncertainty in total emissions for both R-404A and N-40 operated systems. We found that using low GWP refrigerants causes a considerable drop in the impact of uncertainty in the inputs related to direct emissions on the uncertainty of the total emissions of the system.

LCCP↗