Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cost optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Risk-controlled Expansion Planning with Distributed Resources (REPAIR) v1.0

The Risk-controlled Expansion Planning with Distributed Resources (REPAIR) is an innovative tool to support decisions around utility grid planning to prevent and mitigate the impact of outages caused by routine equipment failures (reliability) or by extreme events (resilience), such as storms, earthquakes or wildfires that long term interruption of service. REPAIR is a risk-based optimization and decision-making model allowing informed and transparent "cost vs risk" decisions regarding infrastructural planning of electric utilities. The model considers long-term resilience and reliability planning strategies that rely on traditional infrastructure upgrade (e.g. circuit hardening, reinforcement, new substations, etc.) or new investment alternatives, such as DERs.

Heleno, Miguel [Lawrence Berkeley National Laborat↗

Cognition at the Point of Sensing

Over the last 15 years, compressive sensing techniques have been developed which have the potential to greatly reduce the amount of data collected by systems while preserving the amount of information obtained. A cost of this efficiency is that a computationally-intensive optimization routine must be used to put the sensed data into a form that a person can interpret. At the same time, machine learning techniques have experienced tremendous growth as well. Machines have demonstrated the ability learn how to effectively perform tasks such as detection and classification at speeds much faster than humanly possible. Our goal in this project was to study the feasibility of using compressive sensing systems "at the edge." That is, how can compressive sensing sensors be deployed such that information is created at the remote sensor rather than sending raw data to a central processing location? Studies were performed to analyze whether machine learning could be done on the compressively sensed data in its raw form. If a machine is performing the task, is it possible to do so without putting the data into a human interpretable form? We show that this is possible for some systems, in particular a compressive sensing snapshot imaging spectrometer. Machine learning tasks were demonstrated to be more effective and more robust to noise when the machine learning algorithm worked on data in its raw form. This system is shown to outperform a traditional spectrometer. Techniques for reducing the complexity of the reconstruction routine were also analyzed. Techniques for such as data regularization, deep neural networks, and matrix completion were studied and shown to have benefits over traditional reconstruction techniques. In this project we showed that compressive sensing sensors are indeed feasible at the edge. As always, sensors and algorithms must be carefully tuned to work in the constrained environment. In this project we developed tools and techniques to enable those analyses.

47 OTHER INSTRUMENTATION↗

Options for Subscale Maturation of Advanced Reactor Technologies Testing for Nuclear Thermal Propulsion

Several options could be implemented to establish an irradiation testing capability suitable for investigation of the performance of multiple nuclear thermal propulsion fuel elements at prototypic conditions. The prototypic conditions of interest are based on the current needs of the National Aeronautics and Space Administration’s Space Nuclear Power Program. The results of such testing are also intended to reduce the risks currently seen for any future subscale or full-scale ground testing of an engine-reactor system. The optimal solution is dependent upon several factors such as performance, cost, availability, schedule, technology readiness level, and plans for future testing in the SNP Program. Three options, based on different combinations of these factors, are considered in this report.

33 ADVANCED PROPULSION SYSTEMS↗

Power Supply Options for the Marpi Landfill, Saipan: Feasibility Study

The Marpi Landfill, located on the northern end of the island of Saipan in the Commonwealth of the Northern Mariana Islands (CNMI), is powered by an on-site diesel generator that only operates when the landfill is open and staffed. The CNMI Office of Planning and Development (OPD) aspires to provide the Marpi Landfill with 24-hour power availability despite its remote location and to increase the use of sustainable energy within the CNMI. CNMI has a 20% target for renewable energy consumption, as documented in Sustainable Development Goal #7 in the Comprehensive Sustainable Development Plan (OPD 2021) and the renewable portfolio standard (GPO 2014). To accomplish these goals, the U.S. Department of Energy, through its Interagency Reimbursable Work Agreement with the Federal Emergency Management Agency, funded this feasibility study to assess and prioritize power supply options for the landfill. The availability of solar and wind resources varies seasonally, as does the load. A BESS can help to balance mismatches between generation and load on short (hourly or daily) timescales, but not across seasons. The microgrid scenarios evaluated for Marpi consider options for technology combinations that will both meet the load and utilize available resources, despite the challenge presented by higher loads and lower solar and wind availability during the rainy season, depicted in Figure ES-2. The seven scenarios evaluated are summarized in Table ES-1. Each scenario’s configuration was optimized to include component capacities that reduce capital and operating costs, meet the load, and minimize carbon emissions, as feasible. The costs and levelized cost of energy (LCOE) shown do not assume the use of any grant funding or incentives, although these options were also evaluated. To assist with decision-making, a prioritization matrix (Table ES-3) was created to compare the microgrid scenarios evaluated in this feasibility study according to various stakeholder priorities. The prioritization metrics were chosen based on discussions with OPD and will be finalized through stakeholder feedback. The scenarios were given a score between 1 and 7 for each prioritization metric (the lower the score, the higher the priority), and total scores were calculated using assigned weights based on the relative priority of each metric. The total scores were then ranked to produce a prioritized list of microgrid scenarios based on the metrics most important to the project stakeholders. As shown, scenario 4 (100 kW of solar PV, a 75 kW/300 kWh BESS, and 160 kW of diesel generation) ranks highest.

14 SOLAR ENERGY↗

Techno-economic Analysis and Optimization of Point Source Solvent-Based Carbon Capture Systems at High CO2 Capture Levels for NGCC Power Plants

This poster was presented at the 2024 FECM / NETL Carbon Management Research Project Review Meeting held during Aug 5-9, 2024. It summarizes the research done as a part of CCSI2 for determining the optimal design and operating conditions of an MEA solvent-based carbon capture system connected to a commercial scale NGCC plant, operating at CO2 capture levels beyond 90%. The techno-economic optimization approach is outlined, along with the trends of key cost and performance indicators across high capture levels.

Deshpande, Anuja↗

A Multidisciplinary Approach to Integrated Energy Systems: Advanced Nuclear Plants with Thermal Storage for Dynamic and Flexible Operation in Diverse Markets

Energy supply, distribution, and demand are continuously evolving in accordance with the integration of new power generation sources. In the United States, there is a progressive shift toward incorporating fluctuating energy sources such as wind and solar into the energy mix, alongside the distributed generation. Simultaneously, we are seeing a revolution in consumer technologies such as electric vehicles, energy devices for both residential and commercial use, and industrial processes—all contributing to a fundamental change in energy consumption dynamics. These scenarios have led to huge demand for enhanced flexibility from nuclear power plants (NPPs), requiring them to operate with unprecedented adaptability. Furthermore, advanced NPPs (A-NPPs) could potentially apply to scenarios in which power generation flexibility is prioritized over its current and conventional baseload generation capacity for traditional demand patterns. The present work covers several configurations for coupling nuclear energy production with thermal energy storage (TES). Previous work evaluated systems entailing a simple nuclear-TES configuration that used steam as a heat source for the TES of three different advanced reactors (ARs), but its heat diversion ratio (HDR) for charging was limited. The present work proposes a new configuration that features full decoupling of the nuclear reactor and the power cycle, using reactor coolant (i.e., gas) as a heat source for the TES and offering a theoretically unlimited HDR. This configuration is, however, more complex, as both high- and low-temperature TES (HT-TES and LT-TES) systems are required in order to cover the extended temperature range. Although this configuration imposes certain limitations on the discharge system configuration, it also presents the opportunity to design a more efficient system. For this case in particular, a steam reheat cycle is advantageous. Conventional TES systems take advantage of nominal efficiency when discharging, whereas the reheat cycle in the fully decoupled TES system affords a significant efficiency increase over conventional cases. Material selection, component/equipment sizing, and costing analyses were performed, followed by economic dispatch and size optimization. Dynamic models were developed for the decoupled system in order to generate insights into aspects of off design operation (e.g., drops in cycle efficiency), and these models enable exploration of potential mitigation strategies for addressing such drops. The models also highlight the need to design fail-safes that ensure continuous operational stability and minimize the impact of power ramping on the reactor parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bench-scale Development of a Transformational Graphene Oxide-based Membrane Process for Post-combustion CO 2 Capture

Graphene-based materials, such as graphene and graphene oxide (GO), have been considered as next-generation membrane materials. GTI Energy and The State University of New York at Buffalo (UB) have been developing a transformational GO-based membrane process (designated as GO2) that integrates a high CO 2 /N 2 selectivity membrane (GO-1) and a high CO 2 flux membrane (GO-2) for post-combustion CO 2 capture. An innovative membrane structure, consisting of GO nanochannels intercalated by single-walled carbon nanotube (SWCNT), was developed. The membrane prepared on hollow fiber substrate showed CO 2 permeance as high as 1,300 GPU with CO 2 /N 2 selectivity >200. The membranes were successfully scaled up to effective area of 50-100 cm 2 . The 50-100 cm 2 membranes showed CO 2 /N 2 selectivity ≥200 and CO 2 permeance ≥1,000 GPU for the GO-1 type, and CO 2 /N 2 selectivity ≥20 and CO 2 permeance ≥2,500 GPU for the GO-2 type. The CO 2 capture performance of the GO-based membranes was tested using a simulated flue gas. The testing results indicate that the GO-based membranes are stable in the presence of flue gas contaminants. The GO-based membranes were then further scaled up to a surface area of 1,000 cm 2 . Good stability was achieved during an integrated testing with GO-1 and GO-2 membranes using simulated flue gas. A bench-scale system was designed, constructed, and tested at the National Carbon Capture Center (NCCC). Good stability was achieved during testing of a single-stage process with >10 shutdowns/startups at NCCC. During the integrated testing, the membranes showed good stability at 50°C and 57°C. 70-90% CO 2 removal efficiencies and ≥95% CO 2 purity were validated during the steady state operation at NCCC. Techno-economic analysis indicates the GO2 membrane-based process technology provides a reduction in both the levelized cost of electricity (LCOE) and cost of capture when compared to the reference B12B case presented in the Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity study prepared by the National Energy Technology Laboratory (NETL), before considering any system optimization or improvement opportunities. The benefits are primarily driven by a reduction in the equipment costs of the CO 2 capture process vs. the solvent-based reference process in NETL Case B12B as well as a decrease in the base plant size.

20 FOSSIL-FUELED POWER PLANTS↗

Synergistic Thermo-Microbial-Electrochemical (T-MEC) Approach for Drop-In Fuel Production from Wet Waste

This project successfully developed and demonstrated the synergistic thermo-microbial-electrochemical (T-MEC) process, converting food waste into sustainable biofuels while achieving self-sustaining wastewater treatment and hydrogen production. By integrating hydrothermal liquefaction (HTL) and microbial electrolysis cells (MECs), the project advanced waste-to-fuel technology and expanded the understanding of sustainable waste valorization. It established a scalable framework for achieving high carbon efficiency, effective pollutant removal, and energy recovery, showcasing the potential of combining biological, thermal, and electrochemical systems to optimize resource recovery and reduce environmental impacts. The project demonstrated the technical effectiveness of the T-MEC process, achieving over 50% improvement in carbon efficiency and reducing waste processing costs by more than 25% compared to anaerobic digestion (AD). The HTL pilot reactor processed food waste at 90 kg/h, producing up to 200 L/day of biocrude oil with high conversion efficiency. A critical desalting step in pretreatment prevented catalyst fouling, enabling efficient hydrotreating with 100% deoxygenation and denitrogenation and sulfur reduction to <15 ppm. This positioned the kerosene fraction as a strong candidate for sustainable aviation fuel (SAF). The MECs achieved rapid startup, 86.4% COD removal, and hydrogen production rates of 1.8 L H 2 /L cat /day, among the highest recorded for pilot-scale systems. The integrated process achieved 65% carbon efficiency to biocrude and 58% to finished fuels, outperforming AD's 41% and 33% efficiencies for biogas and natural gas vehicle fuels. System analysis highlighted economic potential, with minimum fuel selling prices (MFSP) decreasing from $\$$25/GGE at 5 tpd to $\$$10/GGE at 500 tpd due to economies of scale. Future work will focus on reducing MEC material and membrane costs, enhancing performance through higher current densities, and creating tailored operational strategies for diverse feedstocks. Optimization of the integrated system will improve scalability and feasibility, positioning the T-MEC process as a competitive solution for converting wet waste into sustainable fuels and clean water. Beyond its technical and economic achievements, the project offers significant public benefits. The T-MEC process provides a sustainable alternative to landfilling and incineration, reducing greenhouse gas emissions and conserving resources. Converting waste into SAF and renewable fuels supports decarbonization in the transportation sector, advancing energy independence and reducing reliance on fossil fuels. Additionally, the process minimizes environmental pollutants, transforming them into valuable products like hydrogen and fuels, contributing to a cleaner and more sustainable future.

09 BIOMASS FUELS↗

A Novel, Low-Cost, Portable Device for Counterfeit and Noncompliant Refrigerant Detection

The increasing prevalence of counterfeit refrigerants presents significant risks to Heating, Ventilation, Air Conditioning, and Refrigeration (HVACR) systems, including compromised equipment performance, safety hazards, and environmental non-compliance. This report details the development of a novel, cost-effective, and portable detection device designed to accurately identify counterfeit refrigerants. The device utilizes a controlled gas sampling and analysis system within a sealed chamber, ensuring precise measurements while maintaining safety through a purging mechanism. The system features a high-sensitivity sensor integrated with an onboard control module that analyzes gas composition in real-time, providing users with clear visual indicators for refrigerant authenticity. Laboratory validation demonstrated the device’s high accuracy (exceeding 95%) in detecting unauthorized refrigerant blends. Key advantages include affordability, ease of use, rapid response time, and compatibility with a wide range of refrigerants. This solution supports compliance with regulatory frameworks such as the AIM Act, enhances safety in HVACR operations, and mitigates the risks associated with counterfeit refrigerants. Future developments will focus on expanding refrigerant detection capabilities, integrating machine learning for enhanced accuracy, implementing cost-reduction strategies to improve accessibility and market adoption, and optimizing system packaging for enhanced field portability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bench-Scale Development of Promoted High-Capacity Structured Sorbents (Final Technical Report)

The project objective was to develop high-capacity structured sorbent capable of achieving low CO 2 removal from air. The sorbent framework consists of an amine-functionalized onto hydrophobic polymer backbone with an added promoter. The functionalized amine provides high CO 2 capacity and adsorption rates and the polymer backbone to reduce water uptake. For the sorbent development, multiple functionalized amines and promoters were assessed to select a candidate that achieved high CO 2 capacity, high adsorption rate, and high stability. A sorbent-coated filter design was selected as the structured sorbent, which provides high sorbent loading capacity and contains an electrically conductive nonwoven filter substrate that can be Joule-heated to provide efficient utilization of available electricity for sorbent regeneration. A commercial partner operated a pilot filter manufacturing line to produce the filter panels coated with the developed sorbent. A 1 kg CO 2 /day bench unit was designed and fabricated to test the structured filter sorbent. The key achievements from the structured sorbent development activity were demonstrating that existing filter industrial-scale processes can be used for manufacturing Susteon’s structured sorbent and completing a proof-of-concept demonstration of the commercially manufactured structured sorbent filters for CO 2 capture from air with direct, Joule-heated regeneration. A techno-economic assessment with sensitivity analysis was conducted on a 100,000 TPY facility with 85% operating capacity. Through sorbent optimization and process design improvements, it is estimated that the cost of capture was reduced from $\$$349/tCO 2 to $\$$241/tCO 2 . The TEA projects further reductions to $165/tCO 2 through enhancements in CO 2 adsorption rate and sorbent capacity and reducing manufacturing and scale up risks. A life cycle analysis was conducted on the same 100,000 TPY facility and confirmed that the facility’s electricity demand drives its greenhouse gas impact. It was determined that electricity supplied through the current grid mix would result in net-positive CO 2 emissions and that achieving net-negative emissions is only possible by powering the system with renewable electricity or fossil fuel sources equipped with carbon capture and sequestration.

36 MATERIALS SCIENCE↗

Final Report: Process Intensification of Hydrogen Production through Sorption-Enhanced Gasification of Biomass

The University of Utah, in partnership with Idaho National Laboratory (INL), evaluated Sorption-Enhanced Gasification (SEG) as a transformative pathway for producing hydrogen with the potential for negative CO 2 emissions. SEG integrates gasification, water-gas shift, and in-situ carbon capture within a dual fluidized bed reactor to enable efficient clean hydrogen production. Key challenges related to biomass variability and process complexity were addressed through feedstock engineering, reaction optimization, and process validation. A co-pelletized biomass–limestone feedstock was developed to simplify feeding and introduction of makeup limestone. Kinetic and sorbent studies identified optimal operating conditions and confirmed the suitability of low-cost limestone, while catalysts were developed to reduce tar formation. Reactor modeling and techno-economic analysis indicated that SEG can achieve competitive hydrogen production costs, particularly when combined with carbon incentives, supporting its potential for scale-up and carbon-negative operation.

08 HYDROGEN↗

Who Controls Energy in the Smart Home? A Multidisciplinary Taxonomy

Advances in technology have begun to open new opportunities for behavior-based and technical approaches to managing residential energy use and meet sustainability-related objectives. Visions of the future predict homes with smart technologies delivering enhanced comfort and cost savings to residents; utility-partners who can remotely optimize energy resources to meet grid needs; and occupants who play more active roles in the energy system supported by advanced information communication technologies. Each of these scenarios implies augmented control over home energy use, yet uncertainties remain regarding which ones will deliver the greatest grid benefits and services to customers in a given situation. These scenarios also raise broader questions regarding customer agency and the relationship between customers and third parties moving forward. While both the provision of information to spur behavior change and automated technologies theoretically enhance control over energy use in the built environment, these strategies are not often studied from an integrated perspective. Seeking to address this gap and develop a deeper understanding of the evolving paradigm of control over home energy use, this paper presents a taxonomy to evaluate perspectives from public policy (ex. demand-side management), technological innovation (automated controls), and user-agency (ex. the role of behavior change) on approaches to managing home energy use. We draw on theoretical and empirical evidence from across disciplines to detail the dimensions and implications of deploying programs that incorporate various levels of control and anticipate such a taxonomy will help holistically map out and evaluate tradeoffs between different approaches to demand-side management moving forward.

McIlvennie, Claire↗

Supporting the Transition from Grid-Scale to Emerging Market Wave Energy Converter Design and Assessment

In the past decade there has been increasing interest in emerging markets for wave energy, both as a stepping stone for development and as a way to create new opportunities for offshore markets such as ocean observation or desalination. Developers who were once focused exclusively on grid-scale development have begun to engage with more unique markets. This has led researchers to begin examining means of assessing emerging-market devices. In this paper, we analyze the Technology Performance Level (TPL) Assessment for its potential use in the assessment of emerging market wave energy converters (EM-WECs). We use Quality Function Deployment (QFD) and a question-by-question analysis of the TPL assessment to determine the changes necessary for such an assessment to be applicable in emerging markets. We discuss how the primary differences between the markets could impact the viable development pathways for developers hoping to succeed in multiple markets. We determine that the different stakeholders and stakeholder requirements of some emerging markets compared to gridscale applications should be met with changes to cost-toperformance metrics, prototype testing processes, recovery planning, materials selection, optimization objectives, and public engagement.

blue economy↗

Fault Characterization and Diagnostics Supporting Condition-Based Operation and Maintenance of Gas Turbine Engines

Condition-Based Operation and Maintenance (CBOM) is the state-of-the-art in maintenance approaches for gas turbine engines. CBOM applies engine sensor information to the optimization of future operation and maintenance procedures; this technique reduces costs for engine operators by minimizing unplanned outages and catastrophic engine degradation. However, due to the complexities of gas turbine operation and the lack of available engine sensors, further development is required to fully realize the benefits of CBOM. In the turbine section, rotating components interact with high temperature flows, which creates intense thermal and mechanical stresses. As a result, there are numerous mechanisms of component degradation in the turbine section. Furthermore, turbine components – like stator vanes and rotor blades – are among the most expensive in the engine because they are complex to design and manufacture. For these reasons, this dissertation addresses two main questions: (i) which parameters or faults within the turbine section are most important to monitor, and (ii) how can these parameters or faults be monitored in an engine-relevant environment? Although many turbine parameters and faults have been investigated in the open literature, there are some faults that are still not well understood. Rotor-casing eccentricity, which causes a non-constant blade tip clearance around the annulus, has not been investigated in terms of its effects on turbine efficiency. Therefore, the first study in this dissertation quantifies overall and local turbine efficiency for varying levels of rotor-casing eccentricity. Results showed negligible variations to overall turbine efficiency, meaning rotor-casing eccentricity only becomes relevant to CBOM when its severity causes rotordynamic issues. Purge flow is critical to turbine hardware longevity because it prevents ingestion of hot main gas path (MGP) flow into the under-platform regions. Despite its importance, there are currently no methods for monitoring purge flow performance in an engine environment. Therefore, the second study in this dissertation develops a predictive model for sealing effectiveness using inputs from two fast-response pressure sensors. Results exhibited low prediction errors across a full range of purge flow rates, which supports the viability of the modelling approach for CBOM. The final two studies in this dissertation address blade coolant flow monitoring. This cooling flow is responsible for protecting the turbine blades from the MGP flow, which exits the combustor at temperatures greater than the blade melting point. These studies showed that temperature measurements on the blade surface can be used to accurately predict blade coolant flow rate, and that defining the candidate features relative to the coolant trajectory is important for maintaining accuracy as coolant flow rate degradation occurs. This work enables blade coolant flow monitoring, which is currently not possible through existing condition monitoring techniques.

condition-based, gas turbines, diagnostics,↗

US ATLAS and US CMS HPC and Cloud Blueprint

The Large Hadron Collider (LHC) at CERN houses two general purpose detectors - ATLAS and CMS - which conduct physics programs over multi-year runs to generate increasingly precise and extensive datasets. The efforts of the CMS and ATLAS collaborations lead to the discovery of the Higgs boson, a fundamental particle that gives mass to other particles, representing a monumental achievement in the field of particle physics that was recognized with the awarding of the Nobel Prize in Physics in 2013 to François Englert and Peter Higgs. These collaborations continue to analyze data from the LHC and are preparing for the high luminosity data taking phase at the end of the decade. The computing models of these detectors rely on a distributed processing grid hosted by more than 150 associated universities and laboratories worldwide. However, such new data will require a significant expansion of the existing computing infrastructure. To address this, both collaborations have been working for years on integrating High Performance Computers (HPC) and commercial cloud resources into their infrastructure and continue to assess the potential role of such resources in order to cope with the demands of the new high luminosity era. US ATLAS and US CMS computing management have charged the authors to provide a blueprint document looking at current and possibly future use of HPC and Cloud resources, outlining integration models, possibilities, challenges and costs. The document will address key questions such as the optimal use of resources for the experiments and funding agencies, the main obstacles that need to be overcome for resource adoption, and areas that require more attention.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Anode Upcycling via Tailored Solvent Treatment

To achieve a truly closed-loop direct recycling process for lithium-ion batteries, all component materials must be recovered. To date, direct recycling method development has primarily focused on the high-value transition-metal cathode materials, while the inherently lower-value graphite has been challenging to recover in a cost-effective manner. However, end-of-life graphite contains a unique engineered value due to the presence of the solid electrolyte interphase (SEI). Growth of the SEI during the cell's active lifetime stabilizes the electronically reactive graphite surface through an irreversible consumption of Li, and thus necessitates both excess lithiation of the cathode and a costly and time-intensive formation procedure during manufacturing. An optimized pre-formed SEI that capitalizes on existing SEI components from end-of-life batteries has the potential to significantly reduce cathode lithiation requirements and eliminate the critical bottleneck of formation cycling during cell remanufacturing. Further, retaining Li at the anode obviates the need for a separate Li leaching and recovery step, improving the overall efficiency of the direct recycling line. In this work, we present a novel approach to "upcycling" spent graphite through use of tailored chemical treatment to remove adverse (i.e., highly resistive and/or poorly passivating) SEI species while retaining beneficially passivating components. We have explored a rational set of solvents spanning a range of polarity, proticity, and molecular size to evaluate structure-property-performance relationships between applied solvent(s), removed and remaining SEI species, and electrochemical response of the resulting graphite product. Further, we have developed and optimized a robust and holistic analysis procedure that couples symmetric-cell electrochemical testing, multi-modal materials characterization, and advanced electrochemical modeling. These analysis results inform a set of correlative metrics for graphite performance relative to both solvent properties and upcycled SEI composition. We demonstrate effective tunability in the residual SEI composition by varying solvent identity and concentration, and report on several promising solvent systems that achieve comparable or performance to pristine graphite.

anode recycling↗

Novel PCM-based fin and tube heat exchanger system for building heating and cooling applications

In the United States, the building sector accounts for 40% of all energy use, and buildings are responsible for more than two-thirds of electricity consumption. Buildings remain the major driver of energy-related carbon emissions, and such emissions are projected to increase in the years ahead because of urbanization and population growth. To accomplish the low carbon energy goal in the building sector, phase change material (PCM)–based thermal energy storage (TES) is increasingly being adopted because it offers several advantages, such as reducing building peak load and energy consumption, enabling large scale deployment of renewables, and improving grid stability. The integration of TES with thermally anisotropic building envelopes (TABEs) is a promising solution because, TABE can redirect natural thermal energy from a building using hydronic loops to TES, and the stored energy can be used later for heating and cooling applications. In this study, we experimentally investigate the thermal performance of a novel fin-tube heat exchanger TES system designed for potential integration with a TABE. An experimental rig for a 5-gal PCM fin-tube heat exchanger system with water as the heat transfer medium is described which records temperatures at the heated and cooled boundaries of the system. Experimental observations provide insight into the role a TES system can play in offsetting a building’s heating and cooling demand and also offer a means to characterize the performance of PCMs for building applications. The scale and study presented in this work will help in the design of future thermal storage systems optimized for storage capacity while also accounting for overall system costs for building applications.

Tamraparni, Achutha↗

2022 Component Innovation Awardee: Pecos Wind Power

Distributed wind energy systems supply electricity for nearby homes and businesses, often in remote and rural regions. Systems capable of capturing energy in areas with low wind speeds make it possible to deploy these clean energy systems in many geographic locations. Pecos Wind Power's 85-kilowatt (kW) horizontal-axis PW85 wind turbine shows potential to reduce the levelized cost of energy by approximately 55% when compared to typical small wind systems while achieving utility-scale capacity factors of more than 40% in areas with lower wind speeds. To maximize cost competitiveness, the Pecos Wind Power turbine needs a blade optimized for low wind speeds. Through its 2022 Competitiveness Improvement Project (CIP) award, Pecos Wind Power and partner Wetzel Wind Energy Services will model, optimize, fabricate, and validate a 14.5-meter wind turbine blade made specifically for these applications. Three prior CIP awards supported Pecos Wind Power's initial development of the PW85 turbine.

CIP↗