Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Long Duration Exposure Facility experiment M0003 deintegration observation database

The four trays of the M0003 materials experiment on LDEF contained 1274 samples from 19 subexperiments. The complete sample complement represented a broad range of materials, including thin film optical coatings, paints, polymer sheets and tapes, adhesives, and composites, for use in various spacecraft applications including thermal control, structures, optics, and solar power. Since some subexperiments included duplicate samples exposed on the leading and trailing edge trays, for 9 week, 19 week, 40 week, and 68 month durations on both the leading and trailing edges, comparisons provided a valuable time history of degradation. During the deintegration of the subexperiments from the M0003 trays, each sample was examined using bright field, dark field, and Normarski light microscopy techniques. Over 3,000 color macrographs and photomicrographs were made of the condition of M0003 trays and the individual samples. Records of the condition of the samples, photographic records, and all available references of publications on postflight analyses on each sample were collected in a database. The photographs provide a visual comparison of the response of materials common to various subexperiments in different LDEF environments. Aerospace Corporation is distributing the database records and photographs and written records on materials of interest from the database is given in this presentation.

Gyetvay, S. R.↗

Long Duration Exposure Facility experiment M0003 deintegration observation data base

The four trays (2 leading edge and 2 trailing edge) of the M0003 materials experiment on the Long Duration Exposure Facility (LDEF) contained 1274 samples from 20 subexperiments. The complete sample complement represented a broad range of materials, including thin film optical coatings, paints, polymer sheets and tapes, adhesives, and composites, for use in various spacecraft applications, including thermal control, structures, optics, and solar power. Most subexperiments contained sets of samples exposed on both the leading and trailing edge trays of LDEF. Each individual sample was examined by high resolution optical microscope during the deintegration of the subexperiments from the M0003 trays. Observations of the post-flight condition of the samples made during this examination were recorded in a computer data base. The deintegration observation data base is available to requesters on floppy disk in 4th Dimension for the Macintosh format. Over 3,000 color macrographs and photomicrographs were shot to complement the observation records and to document the condition of the individual samples and of the M0003 trays. The photographs provide a visual comparison of the response of materials in leading and trailing edge LDEF environments. The Aerospace Corporate Archives is distributing photographs of the samples and hard copies of the database records to the general public upon request. Information on obtaining copies of the data base disks and for ordering photographs and records of specific samples or materials are given.

Gyetvay, S. R.↗

Information Foraging and Change Detection for Automated Science Exploration

This paper presents a new algorithm for autonomous on-line exploration in unknown environments. The objective is to free remote scientists from possibly-infeasible extensive preliminary site investigation prior to sending robotic agents. We simulate a common exploration task for an autonomous robot sampling the environment at various locations and compare performance against simpler control strategies. An extension is proposed and evaluated that further permits operation in the presence of environmental variability in which the robot encounters a change in the distribution underlying sampling targets. Experimental results indicate a strong improvement in performance across varied parameter choices for the scenario.

automated exploration↗

Lunar carbon chemistry - Relations to and implications for terrestrial organic geochemistry.

Survey of the various ways in which studies of lunar carbon chemistry have beneficially affected terrestrial organic geochemistry. A lunar organic gas-analysis operating system is cited as the most important instrumental development in relation to terrestrial organic geochemistry. Improved methods of analysis and handling of organic samples are cited as another benefit derived from studies of lunar carbon chemistry. The problem of controlling contamination and minimizing organic vapors is considered, as well as the possibility of analyzing terrestrial samples by the techniques developed for lunar samples. A need for new methods of analyzing carbonaceous material which is insoluble in organic solvents is indicated.

Eglinton, G.↗

Rock sampling

A method for sampling rock and other brittle materials and for controlling resultant particle sizes is described. The method involves cutting grooves in the rock surface to provide a grouping of parallel ridges and subsequently machining the ridges to provide a powder specimen. The machining step may comprise milling, drilling, lathe cutting or the like; but a planing step is advantageous. Control of the particle size distribution is effected primarily by changing the height and width of these ridges. This control exceeds that obtainable by conventional grinding.

Blum, P.↗

Study on the applicability of a precise, accurate method for rapid evaluation of engine and lubricant performance

The development of a procedure for obtaining data related to wear metal determinations in used lubricants is discussed. The procedure makes it possible to obtain rapid, simultaneous determinations of a number of wear metals at levels of parts per thousand to low parts per billion using a small amount of sample. The electrode assembly and instrumentation used in the process are described. Samples of data obtained from tests conducted under controlled conditions are tabulated.

Kinard, J. T.↗

Portable, wind sensitive, directional air sampler

Air Scout unit has preset timer that controls length of time filter slides are in sampling position. At end of sampling period, fresh slide is automatically moved into position, and exposed filter is displaced into storage compartment. Device may be set up, loaded, programmed, and left to acquire samples automatically.

Deyo, J. N.↗

The Apollo 16 microbial response to space environment experiment

The effect was evaluated of a particular space flight on the survival rate of nine different species. Although a reasonable variety of organisms (viruses, yeasts, filamentous fungi, bacteria, and an invertebrate) were tested under several different conditions, no statistically valid differences could be detected in the survival of flight samples when compared to corresponding ground-based controls. In general, these evaluations were based on multiple observations of from ten to thirty replicates of up to one million cells each. While the results conflict with those of certain other space flight investigations, it is observed that the conditions of a particular space flight cannot be exactly duplicated, and therefore results from different flights are not directly comparable.

Gerald R. Taylor↗

Compressible laminar boundary layers with suction on swept and tapered wings

In this paper we present a numerical method for solving the compressible laminar boundary-layer equations with suction on swept and tapered wings. The method employs an efficient two-point finite-difference method to solve the governing equations, and a very convenient similarity transformation which removes the wall normal velocity as a boundary condition and places it into the governing equations as a parameter. In this way the awkward nonlinear boundary condition which couples all the variables is avoided. To test and demonstrate the method, we present a sample calculation for a typical laminar-flow-control (LFC) wing.

Kaups, K.↗

Effects of electron irradiation on large insulating surfaces used for European Communications Satellites

Samples of aluminized Kapton used for passive thermal control on the VHF shield and the antenna dish of ESA's OTS satellite and its derivatives were subjected to an incident electron beam of 25 keV and irradiated for 8 hours at room temperature and at -173 C under a vacuum of the 10 to the minus 6 th power torr. Visual observations during electron irradiation, measurements of leakage current and discharge characteristics, and material degradation following completion of irradiation are discussed.

Reddy, J.↗

Surface accuracy measurement system deployable reflector antennas

Conceptual optical sensor configurations for measuring the surface deformations of large, deployable space antennas are described. These antennas include precision deployable reflectors up to 30 meters diameter and 1000 GHz frequency and mesh deployable reflectors up to 100 meters diameter and 30 GHz frequency. For each representative antenna configuration, the surface deformation sensor provides continuous, real-time measurements at a sufficient number of sample points to be compatible with active surface control. Moreover, the sensor system does not interfere with the mechanical or microwave characteristics of either the antenna surface or the feed. For the applications considered, the sensor system consists of a central receiver ring containing six to ten long focal length, angle measuring instruments, each viewing a dedicated set of bright point targets at the antenna. The targets, either light emitting diodes or illuminated retroreflectors, are modulated to eliminate errors from spurious backgrounds. Very preliminary performance estimates indicate that the sensor system, using commerical grade components, can produce a 20th to a 30th wavelength accuracy (3 sigma).

Neiswander, R. S.↗

Video framerate, resolution and grayscale tradeoffs for undersea telemanipulator

The product of Frame Rate (F) in frames per second, Resolution (R) in total pixels and grayscale in bits (G) equals the transmission band rate in bits per second. Thus for a fixed channel capacity there are tradeoffs between F, R and G in the actual sampling of the picture for a particular manual control task in the present case remote undersea manipulation. A manipulator was used in the MASTER/SLAVE mode to study these tradeoffs. Images were systematically degraded from 28 frames per second, 128 x 128 pixels and 16 levels (4 bits) grayscale, with various FRG combinations constructed from a real-time digitized (charge-injection) video camera. It was found that frame rate, resolution and grayscale could be independently reduced without preventing the operator from accomplishing his/her task. Threshold points were found beyond which degradation would prevent any successful performance. A general conclusion is that a well trained operator can perform familiar remote manipulator tasks with a considerably degrade picture, down to 50 K bits/ sec.

Ranadive, V.↗

An overview of the thematic mapper geometric correction system

Geometric accuracy specifications for LANDSAT 4 are reviewed and the processing concepts which form the basis of NASA's thematic mapper geometric correction system are summarized for both the flight and ground segments. The flight segment includes the thematic mapper instrument, attitude measurement devices, attitude control, and ephemeris processing. For geometric correction the ground segment uses mirror scan correction data, payload correction data, and control point information to determine where TM detector samples fall on output map projection systems. Then the raw imagery is reformatted and resampled to produce image samples on a selected output projection grid system.

Beyer, E. P.↗

Ion-beam-textured and coated surfaces experiment (S1003)

The objective of this LDEF experiment is to measure the effects of exposure to the shuttle launch and near Earth space environments on the optical properties of ion beam textured high absorptance solar thermal control surfaces, the optical and electrical properties of ion beam sputtered conductive solar thermal control surfaces, and the weight loss of ion beam deposited oxide polymer films. The various types of surfaces to be tested include six major categories: (1) ion beam textured surfaces suitable for space solar thermal (solar concentration) application; (2) painted and/or state of the art solar thermal surfaces; (3) ion beam sputtered conductive coatings for thermal and space charge control (e.g., indium-oxide coated metalized FEP Teflon); (4) ion beam sputtered conductive coated solar sail materials for space charge control and cooling through emittance; (5) micrometeoroid sensitive samples whose optical properties change only as a result of micrometeoroid impact; and (6) Kapton coated with oxide polymer films to minimize oxygen degradation at near Earth orbit altitudes.

Mirtich, M. J., Jr.↗

Turbidity very near the critical point of methanol-cyclohexane mixtures

The turbidity of a critical mixture of methanol and cyclohexane has been measured extremely close to the consolute point. The data span the reduced-temperature range between 10 to the -7th and 10 to the -3d, which is two decades closer to Tc than previous measurements. In this temperature range, the turbidity varies approximately as 1nt, as expected from the integrated form for Ornstein-Zernike scattering. A thin cell (200-micron optical path) with a very small volume (0.08 ml) was used to avoid multiple scattering. A carefully controlled temperature history was used to mix the sample and to minimize the effects of critical wetting layers. The data are consistent with a correlation-length amplitude of 3.9 plus or minus 1.0 A, in agreement with the value 3.5 A calculated from two-scale-factor universality and heat-capacity data from the literature.

Kopelman, R. B.↗

A CCD System for Photometry of Direct and Spectroscopic Images

A charge-coupled device (CCD) for direct imagery at the focus of a ground-based telescope and for high dispersion spectroscopy of stars is evaluated. The CCD is an RCA SID 53612 thinned, buried channel array of 512x320 30-micron square pixels that are back-illuminated and refrigerated to about -60 C in a rugged, RF-shielded vacuum housing. The double-correlated sampling (integrator) readout system, the Z80 microprocessor readout control system, and the data collection system are described. The readout noise is 120 electron-hole pairs (ehp) per pixel per readout, the thermal dark current is 50 ehp/pixel/sec, and the scale of the 12-bit analog-to-digital converter is 25 ehp/AD unit. Unique features of this system are compared to other astronomical implementations of the same model of CCD.

Frecker, J. E.↗