Optimization of a gas–liquid plasma reactor for water treatment applications: Design guidelines and electrical circuit considerations

To provide insights into the design, optimization, and scale up of plasma reactors for water treatment, the influences of discharge energy, grounded electrode size and position, and number of high voltage (HV) discharge points on the production of reactive species and the degradation of 1,4-dioxane and perfluorooctanoic acid in a gas–liquid electrical discharge plasma reactor were assessed. Discharge energy and plasma area largely control the treatment effectiveness. Increasing the number of discharge points lowers the voltage in the reactor and consequently the production rates of reactive species. Finally, bench-scale findings apply directly to large volume systems, resulting in the highest contaminant removal rates using a single HV electrode and a grounded electrode spanning the entirety of the treatment zone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Safety of Sealed Radioactive Sources

Sealed radioactive sources are used in a wide variety of occupational settings and under differing regulatory/licensing structures. The definition of a sealed radioactive source varies between US regulatory authorities and standard-setting organizations. Potential problems with sealed sources cover a range of risks and impacts. The loss of control of high activity sealed sources can result in very high or even fatal doses to members of the public who come in contact with them. Sources that are not adequately sealed, and that fail, can cause spread of contamination and potential intake of radioactive material. There is also the possibility that sealed sources may be (or threatened to be) used for terrorist purposes and disruptive opportunities. Until fairly recently, generally-licensed sealed sources and devices received little, if any, regulatory oversight, and were often forgotten, lost or unaccounted for. Nonetheless, generally licensed devices can contain fairly significant quantities of radioactive material and there is some potential for exposure if a device is treated in a way that it was never designed. Industrial radiographers use and handle high activity and/or high-dose rate sealed sources in the field with a high degree of independence and minimal regulatory oversight. Failure to follow operational procedures and properly handle radiography sources can and has resulted in serious injuries and death. Industrial radiographers have experienced a disproportionately large fraction of incidents that result in unintended exposure to radiation. Sources do not have to contain significant quantities of radioactive material to cause problems in the event of their failure. A loss of integrity can cause the spread of contamination and potential exposure to workers and members of the public. The NCRP has previously provided recommendations on select aspects of sealed source programs. Future efforts to provide recommendations for sealed source programs are discussed.

radioactive material↗

Cementitious Wasteforms for Immobilization of Low-Activity Radioactive Wastes

Solidification of low-activity wastes with cementitious materials is a widely accepted technique that contains and isolates waste from the hydrologic environment. The radionuclides I-129, Se-75, Tc-99, and U-238 are identified as long-term dose contributors. The anionic nature of these radionuclides in aqueous solutions allows them to readily leach into the subsurface environment. Any failure of concrete encasement may result in water intrusion and consequent mobilization of radionuclides from the waste packages via mass flow and/or diffusion into the surrounding subsurface environment. Assessing the long-term performance of waste grouts for encasement of radionuclides requires understanding the: (1) speciation and interaction of the radionuclides within the concrete wasteform, (2) diffusion of radionuclide species when contacted with vadose zone porewater or groundwater under environmentally relevant conditions, and (3) long-term durability and weathering of concrete waste forms. An improved understanding of the interactions of long-lived radionuclides in cementitious matrices will improve predictions of the long-term fate of these sequestered contaminants. An integrated laboratory investigation has been conducted including: (1) a multifaceted spectroscopic investigation to interrogate the speciation and interaction of radionuclides within concrete wasteforms, (2) solubility tests to quantify the stability of solid phases identified as radionuclide-controlling phases, (3) quantify the diffusion of radionuclides from concrete wasteforms into surrounding subsurface sediment under realistic moisture contents (4%, 7%, and 15% by weight moisture content), (4) quantify the long-term durability of concrete waste forms as a function environmental parameters relevant to depository conditions, and (5) identify the formation of secondary phases or processes (microcracking) that influence radionuclide retention. Data obtained from this investigation provides valuable information for understanding the speciation, behavior, and fate of radionuclides immobilized within concrete wasteforms under vadose zone conditions and underscores the necessity for robust, multi-disciplinary performance assessments for concrete waste forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Vector Sensor-Based Acoustic Characterization System for Marine Renewable Energy

NoiseSpotter is a passive acoustic monitoring system that characterizes, classifies, and geo-locates anthropogenic and natural sounds in near real time. It was developed with the primary goal of supporting the evaluation of potential acoustic effects of offshore renewable energy projects. The system consists of a compact array of three acoustic vector sensors, which measures acoustic pressure and the three-dimensional particle velocity vector associated with the propagation of an acoustic wave, thereby inherently providing bearing information to an underwater source of sound. By utilizing an array of three vector sensors, the application of beamforming techniques can provide sound source localization, allowing for characterization of the acoustic signature of specific underwater acoustic sources. Here, performance characteristics of the system are presented, using data from controlled acoustic transmissions in a quiet environment and ambient noise measurements in an energetic tidal channel in the presence of non-acoustic flow noise. Data quality is demonstrated by the ability to reduce non-acoustic flow noise contamination, while system utility is shown by the ability to characterize and localize sources of sound in the underwater environment.

16 TIDAL AND WAVE POWER↗

Governing Constraints of Chromium(VI) Formation from Chromium(III)-Bearing Minerals in Soils and Sediments

The potential for geogenic Cr(VI) contamination is vast, yet it is difficult to predict susceptible environments as groundwater Cr(VI) concentrations vary significantly, even within a given aquifer, due to physical and hydrologic heterogeneity. The physical structure of soils and sediments exerts a dominant control on Cr(VI) production by dictating the separation distance of reactive phases, the diffusion distance from Cr(VI) generation sites to advecting groundwater, and by influencing infiltration rates and porewater velocity. Here, we used a dual-pore domain model to investigate the relative control of these parameters on Cr(VI) production. The reaction distance between Cr(III)-bearing minerals and Mn oxides predominantly controls Cr(VI) export to advecting groundwater, while changes in diffusion distance between sites of Cr(VI) generation and advective flow channels generally have little impact on steady-state Cr(VI) concentrations. Changes in Cr(VI) diffusion distance can, however, increase the time required for groundwater Cr(VI) concentrations to reach a steady-state; thus, under fluctuating hydrologic and biogeochemical conditions, long diffusion distances still have the potential to suppress Cr(VI) supply to advecting water. Furthermore, we show that high porewater flow velocities effectively dilute Cr(VI) diffusing from soil/sediment aggregates, thus minimizing Cr(VI) concentrations relative to lower porewater velocities. The strong control that the physical/hydrologic parameters exert on Cr(VI) production appears to overwhelm the impact of Cr(III)-mineral solubility within soils and sediments.

Hausladen, Debra (ORCID:0000000342356294)↗

Oak Ridge 25URC Tandem Accelerator 2007 SNEAP Lab Report

During FY 2008, the 25URC operated for slightly over 3,000 research hours. The radioactive species 80Ge and 17,18F accounted for 763 of these hours. This included an experiment using 17F which was only possible due to an improvement of a factor of 50 in beam intensity over our previous facility record. Twenty stable beam species were provided this year. Operation for the experimental program was at terminal potentials from 2.02 to 23.8 MV. Approximately 200 hours of conditioning were done to return the machine to operation after tank openings. There were six tank openings during the year: three scheduled for general maintenance and three unscheduled. Two of the unscheduled openings were required to correct shorting rod issues and the other was to reestablish communication with one of the major dead sections. On July 28, an event happened that caused all accelerators at the Holifield Radioactive Ion Beam Facility (HRIBF) to suspend operation. At approximately 8 AM on that Monday, during operations with approximately 12 {micro}A of 50-MeV protons on a uranium carbide target, delivering neutron-rich 81Zn beam to the new Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS), a radiological control technician (RCT) reported higher than normal radiation levels just outside the shield door to the IRIS1 vault (the room in which RIBs are produced at HRIBF). The measured dose rate equivalent was 4 mrem/hr. The presence of radiological contamination on the floor just outside the shield door was subsequently noted, as was the possible presence of airborne radioactivity. These observations were reported to facility management. Accelerators were put in standby immediately and the building evacuated. The event was declared a laboratory operational emergency. Parts of the building were cleared for reentry to collect belongings on Monday afternoon. The entire building was cleared for reoccupation on Tuesday morning after a detailed radiological survey found no contamination outside the shielded vaults. No decontamination was required. No individual received any detectable radiological dose as a result of this event. The 25URC tandem accelerator was given permission to resume operation with stable beams in early September, but radioactive ion production is still not allowed. Subsequent analysis indicated a release that consisted entirely of noble gasses (Xe and Kr isotopes). We believe we have identified two unrelated failures, one associated with the HVAC system and the other with the roughing system exhaust which accounts for both the escape of noble gasses into the IRIS1 vault and their migration outside the vault. An investigation team report is expected by October 24. At that time, corrective actions will be determined and the path to future radioactive ion beam production will be known. The break from operations allowed a few upgrades to be implemented. The most notable was the installation and commissioning of a SNICS ion source purchased from National Electrostatics Corporation (NEC). The SNICS replaced the old Alton/Aarhus source that we have used for many years. An ANU style gas cathode holder was purchased also but has not yet been implemented. The first beams have been produced by the source and the biggest problem encountered was reducing the beam for very low current experiments. A new power supply for the injection magnet was installed during this period also. Radioactive ion beam (RIB) development at the High Power Target Laboratory (HPTL) has been delayed this year while installing the platforms, conduits and equipment for the second Injector for Radioactive Ion Species (IRIS2) which is co-located with the HPTL facility. The majority of development activities have been performed at the two off-line ion source test facilities (ISTF1 and ISTF2) and the On-Line Test Facility (OLTF). Both test facilities have been developing systems which will eventually be used with IRIS2. Two new tunable Ti:Sapphire lasers have been ordered for continuing development of an ion source based on laser ionization using all solid-state lasers. When these are delivered, we will have a complete laser system. The other ion source test facility is continuing development of a negative-ion cooler for beam purification using photodetachment. This process has been demonstrated to work well in three systems so far (removing Co from Ni, removing S from Cl, and removing O from F). The original ion cooler has been modified to allow for use on the IRIS2 platform. Testing of this modified device is starting now. The OLTF has been used to test new types of uranium carbide targets for the electron beam plasma source (which are used for neutron-rich RIB campaigns) and to test a novel ion source which may result in purified beams of radioactive strontium isotopes. This ion source uses a quartz tube in the transfer line between the production target and the ion source to selectively slow down some elements such as rubidium and cesium.

43 PARTICLE ACCELERATORS↗

Oak Ridge 25URC Tandem Accelerator 2008 SNEAP Lab Report

During FY 2008, the 25URC operated for slightly over 3,000 research hours. The radioactive species {sup 80}Ge and {sup 17,18}F accounted for 763 of these hours. This included an experiment using {sup 17}F which was only possible due to an improvement of a factor of 50 in beam intensity over our previous facility record. Twenty stable beam species were provided this year. Operation for the experimental program was at terminal potentials from 2.02 to 23.8 MV. Approximately 200 hours of conditioning were done to return the machine to operation after tank openings. There were six tank openings during the year: three scheduled for general maintenance and three unscheduled. Two of the unscheduled openings were required to correct shorting rod issues and the other was to reestablish communication with one of the major dead sections. On July 28, an event happened that caused all accelerators at the Holifield Radioactive Ion Beam Facility (HRIBF) to suspend operation. At approximately 8 AM on that Monday, during operations with approximately 12 {micro}A of 50-MeV protons on a uranium carbide target, delivering neutron-rich {sup 81}Zn beam to the new Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS), a radiological control technician (RCT) reported higher than normal radiation levels just outside the shield door to the IRIS1 vault (the room in which RIBs are produced at HRIBF). The measured dose rate equivalent was 4 mrem/hr. The presence of radiological contamination on the floor just outside the shield door was subsequently noted, as was the possible presence of airborne radioactivity. These observations were reported to facility management. Accelerators were put in standby immediately and the building evacuated. The event was subsequently declared a laboratory operational emergency. Parts of the building were cleared for reentry to collect belongings on Monday afternoon. The entire building was cleared for reoccupation on Tuesday morning after a detailed radiological survey found no contamination outside the shielded vaults. No decontamination was required. No individual received any detectable radiological dose as a result of this event. The 25URC tandem accelerator was given permission to resume operation with stable beams in early September, but radioactive ion production is still not allowed. Subsequent analysis indicated a release that consisted entirely of noble gasses (Xe and Kr isotopes). We believe we have identified two unrelated failures, one associated with the HVAC system and the other with the roughing system exhaust which accounts for both the escape of noble gasses into the IRIS1 vault and their migration outside the vault. An investigation team report is expected by October 24. At that time, corrective actions will be determined and the path to future radioactive ion beam production will be known. The break from operations allowed a few upgrades to be implemented. The most notable was the installation and commissioning of a SNICS ion source purchased from National Electrostatics Corporation (NEC). The SNICS replaced the old Alton/Aarhus source that we have used for many years. An ANU style gas cathode holder was purchased also but has not yet been implemented. The first beams have been produced by the source and the biggest problem encountered was reducing the beam for very low current experiments. A new power supply for the injection magnet was installed during this period also. Radioactive ion beam (RIB) development at the High Power Target Laboratory (HPTL) has been delayed this year while installing the platforms, conduits and equipment for the second Injector for Radioactive Ion Species (IRIS2) which is co-located with the HPTL facility. Therefore, the majority of development activities have been performed at the two off-line ion source test facilities (ISTF1 and ISTF2) and the On-Line Test Facility (OLTF). Both test facilities have been developing systems which will eventually be used with IRIS2. Two new tunable Ti:Sapphire lasers have been ordered for continuing development of an ion source based on laser ionization using all solid-state lasers. When these are delivered, we will have a complete laser system. The other ion source test facility is continuing development of a negative-ion cooler for beam purification using photodetachment. This process has been demonstrated to work well in three systems so far (removing Co from Ni, removing S from Cl, and removing O from F). The original ion cooler has been modified to allow for use on the IRIS2 platform. Testing of this modified device is starting now. The OLTF has been used to test new types of uranium carbide targets for the electron beam plasma source (which are used for neutron-rich RIB campaigns) and to test a novel ion source which may result in purified beams of radioactive strontium isotopes.

43 PARTICLE ACCELERATORS↗

The corrinoid cofactor of reductive dehalogenases affects dechlorination rates and extents in organohalide-respiring Dehalococcoides mccartyi

Corrinoid auxotrophic organohalide-respiring Dehalococcoides mccartyi (Dhc) strains are keystone bacteria for reductive dechlorination of toxic and carcinogenic chloroorganic contaminants. We demonstrate that the lower base attached to the essential corrinoid cofactor of reductive dehalogenase (RDase) enzyme systems modulates dechlorination activity and affects the vinyl chloride (VC) RDases BvcA and VcrA differently. Amendment of 5,6-dimethylbenzimidazolyl-cobamide (DMB-Cba) to Dhc strain BAV1 and strain GT cultures supported cis-1,2-dichloroethene-to-ethene reductive dechlorination at rates of 107.0 (±12.0) μM and 67.4 (±1.4) μM Cl - released per day, respectively. Strain BAV1, expressing the BvcA RDase, reductively dechlorinated VC to ethene, although at up to fivefold lower rates in cultures amended with cobamides carrying 5-methylbenzimidazole (5-MeBza), 5-methoxybenzimidazole (5-OMeBza) or benzimidazole (Bza) as the lower base. In contrast, strain GT harboring the VcrA RDase failed to grow and dechlorinate VC to ethene in medium amended with 5-OMeBza-Cba or Bza-Cba. The amendment with DMB to inactive strain GT cultures restored the VC-to-ethene-dechlorinating phenotype and intracellular DMB-Cba was produced, demonstrating cobamide uptake and remodeling. The distinct responses of Dhc strains with BvcA versus VcrA RDases to different cobamides implicate that the lower base exerts control over Dhc reductive dechlorination rates and extents (that is, detoxification), and therefore the dynamics of Dhc strains with discrete reductive dechlorination capabilities. Furthermore, these findings emphasize that the role of the corrinoid/lower base synthesizing community must be understood to predict strain-specific Dhc activity and achieve efficacious contaminated site cleanup.

59 BASIC BIOLOGICAL SCIENCES↗

Controlling Oxidation of Nb in Oxygen Abundant Environments

Modern particle accelerators depend on Superconducting Radio Frequency (SRF) cavities made from high-purity niobium (Nb) to achieve optimal performance, including high quality factors and strong accelerating gradients. However, when exposed to air, niobium naturally forms a complex oxide layer that can introduce surface imperfections and carbon contamination. This work examines an alternative oxidation strategy under oxygen-rich conditions to better regulate the oxide formation process. The ultimate objective is to improve surface uniformity and cleanliness, thereby reducing defect density and enhancing performance. We used Confocal Microscopy, Scanning Electron Microscopy (SEM), and X-Ray Photoelectron Spectroscopy (XPS) to analyze surface changes. We used standard metrics, like Arithmetic Average Roughness (Ra) and Root Mean Square (Rq). Three oxidation methods were applied: short, extended, and a repeated HF and H₂O₂ oxidation process. Preliminary results show promising reductions in carbon contamination and surface defects.

Romero, Juan [Fermilab]↗

A Frozen Soil Barrier to Control Groundwater Inflow into Damaged Reactors at the Fukushima Daiichi Nuclear Power Station - 16613

Reactor buildings and support facilities at the Fukushima Daiichi Nuclear Power Station (F1 Site) were damaged by a March 2011 tsunami. In response, the Tokyo Electric Power Company (TEPCO) is implementing a number of countermeasures to limit the releases and impacts of contaminated water to the surrounding environment. The diverse countermeasures work together in an integrated manner to provide different types, and several levels, of environmental protection. In general, the strategy represents an example of a 'defense in depth' concept that is used for nuclear facilities around the world. One of the key countermeasures is a frozen soil barrier encircling the damaged reactor facilities. The frozen barrier is intended to limit the flow of water into the area, reduce the amount of water entering damaged reactors, and reduce the resulting volume of contaminated water that requires treatment and storage. The frozen soil barrier was designed and installed by a team from TEPCO and Kajima Corporation. A group of scientists and engineers from US Department of Energy National Laboratories provided independent evaluation of the frozen barrier design and operational plans along with technical recommendations to the TEPCO team. The frozen soil barrier design extends to about 30 m depth; the bottom of the barrier is in a low permeability interval, and the total barrier length around the reactors is just over 1.5 km. The barrier required 1927 total boreholes: 1568 for freeze pipes plus 359 for temperature monitoring arrays. Drilling of all of the boreholes was completed November 9, 2015. Construction of the refrigeration plant is complete and all of the above ground piping/manifolds are in the final stages of construction. The DOE laboratory independent assessment of the frozen soil barrier concluded that the technical characteristics of a frozen barrier are relatively well suited to Fukushima-specific hydrogeologic conditions and the need for reducing the inflow of water into damaged reactors at the F1 Site. The scale of the Fukushima barrier is bounded by industry experience and the equipment and infrastructure proposed for the ground freezing is well understood. The on-site pilot test at Fukushima indicated predictable ground freezing and supported the full scale design parameters. These factors increase the confidence in the frozen soil barrier project underway at Fukushima. TEPCO is currently working with the Japanese Nuclear Regulatory Authority (NRA), providing operational plans/strategies for the frozen soil barrier and modeling results of the projected performance. Full scale frozen soil barrier operations are to begin after authorization from NRA. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

TECHNICAL BASIS FOR EVALUATING SURFACE BARRIERS TO PROTECT GROUNDWATER FROM DEEP VADOSE ZONE CONTAMINATION

The U.S. DOE and its predecessors released nearly 2 trillion liters (450 billion gallons) of contaminated liquid into the vadose zone at the Hanford Site. Some of the contaminants currently reside in the deeper parts of the vadose zone where they are much less accessible to characterization, monitoring, and typical remediation activities. The DOE Richland Operations Office (DOE-RL) prepared a treatability test plan in 2008 to examine remediation options for addressing contaminants in the deep vadose zone; one of the technologies identified was surface barriers (also known as engineered barriers, covers, and caps). In the typical configuration, the contaminants are located relatively close to the surface, generally within 15 m, and thus they are close to the base of the surface barrier. The proximity of the surface barrier under these conditions yielded few concerns about the effectiveness of the barrier at depth, particularly for cases in which the contaminants were in a lined facility. At Hanford, however, some unlined sites have contaminants located well below depths of 15 m. The issue raised about these sites is the degree of effectiveness of a surface barrier in isolating contaminants in the deep vadose zone. Previous studies by Hanford Site and PNNL researchers suggest that surface barriers have the potential to provide a significant degree of isolation of deep vadose zone contaminants. The studies show that the actual degree of isolation is site-specific and depends on many factors, including recharge rates, barrier size, depth of contaminants, geohydrologic properties ofthe sediments, and the geochemical interactions between the contaminants and the sediments. After the DOE-RL treatability test plan was published, Pacific Northwest National Laboratory was contracted to review the information available to support surface barrier evaluation for the deep vadose zone, identify gaps in the information and outcomes necessary to fill the data gaps, and outline tasks to achieve those outcomes. Full understanding of contaminant behavior in the deep vadose zone is constrained by four key data gaps: limited access; limited data; limited time; and the lack of an accepted predictive capability for determining whether surface barriers can effectively isolate deep vadose zone contaminants. Activities designed to fill these data gaps need to have these outcomes: (1) common evaluation methodology that provides a clear, consistent, and defensible basis for evaluating groundwater impacts caused by placement of a surface barrier above deep vadose zone contamination; (2) deep vadose zone data that characterize the lithology, the spatial distribution of moisture and contaminants, the physical, chemical, and biological process that affect the mobility of each contaminant, and the impacts to the contaminants following placement of a surface barrier; (3) subsurface monitoring to provide subsurface characterization of initial conditions and changes that occur during and following remediation activities; and (4) field observations that span years to decades to validate the evaluation methodology. A set of six proposed tasks was identified to provide information needed to address the above outcomes. The proposed tasks are: (1) Evaluation Methodology - Develop common evaluation methodology that will provide a clear, consistent, and defensible basis for evaluating groundwater impacts caused by placement of a surface barrier above deep vadose zone contamination. (2) Case Studies - Conduct case studies to demonstrate the applicability ofthe common evaluation methodology and provide templates for subsequent use elsewhere. Three sites expected to have conditions that would yield valuable information and experience pertinent to deep vadose zone contamination were chosen to cover a range of conditions. The sites are BC Cribs and Trenches, U Plant Cribs, and the T Farm Interim Cover. (3) Subsurface Monitoring Technologies - Evaluate minimally invasive geophysical approaches for delineating subsurface plumes and monitoring their migration in the deep vadose zone. (4) Controlled Field Test at Sisson and Lu Site - Evaluate the ability ofthe model to predict long-term liquid, vapor, and chemical transport processes at a well-characterized site containing a plume of subsurface water and tracer remaining from injections in the early 1980s and 2000s. (5) Deep Vadose Zone Monitoring at T Farm - Demonstrate the ability of the geophysical sensors and the model to detect and predict long-term migration of liquid and vapor between the vadose zone beneath the infiltration area and the vadose zone protected by the interim cover. (6) Deep Vadose Zone Monitoring at the Prototype Hanford Barrier - Demonstrate the ability of geophysical sensors and the model to detect and predict the hydrologic conditions in the vadose zone beneath the Prototype Hanford Barrier 15 years after construction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unanticipated potential cancer risk near metal recycling facilities

Metal recycling is an important growing industry. Prior to this study, area sources consisting of metal recycling facilities fell in a category of limited regulatory scrutiny because of assumed low levels of annual emissions. Initiating with community complaints of nuisance from smoke, dust and odor, the Houston Department of Health and Human Services (HDHHS) began a monitoring program outside metal recycler facilities and found metal particulates in outdoor ambient air at levels which could pose a carcinogenic human health risk. In a study of five similar metal recycler facilities which used a torch cutting process, air downwind and outside the facility was sampled for eight hours between 6 and 10 times each over 18 months using a mobile laboratory. Ten background locations were also sampled. Iron, manganese, copper, chromium, nickel, lead, cobalt, cadmium and mercury were detected downwind of the metal recyclers at frequencies ranging from 100% of the time for iron to 2% of the time for mercury. Of these metals, chromium, nickel, lead, cobalt, cadmium and mercury were not detected in any sample in the background. Two pairs of samples were analyzed for total chromium and hexavalent chromium to establish a ratio of the fraction of hexavalent chromium in total chromium. This fraction was used to estimate hexavalent chromium at all locations. The carcinogenic risk posed to a residential receptor from metal particulate matter concentrations in the ambient air attributed to the metal recyclers was estimated from each of the five facilities in an effort to rank the importance of this source and inform the need for further investigation. The total risk from these area sources ranged from an increased cancer risk of 1 in 1,000,000 to 6 in 10,000 using the 95th upper confidence limit of the mean of the carcinogenic metal particulate matter concentration, assuming the point of the exposure is the sample location for a residential receptor after accounting for wind direction and the number of shifts that could operate a year. Further study is warranted to better understand the metal air pollution levels in the community and if necessary, to evaluate the feasibility of emission controls and identify operational improvements and best management practices for this industry. This research adds two new aspects to the literature: identification of types and magnitude of metal particulate matter air pollutants associated with a previously unrecognized area source, metal recyclers and their potential risk to health. -- Highlights: • Air monitoring study in response to community complaints found metal contamination. • Metal recyclers found to potentially pose cancer from metal particulates • Chromium, nickel, cobalt and cadmium samples were detected in five metal recyclers. • These metals were not detected in background air samples. • Estimated increased cancer risk ranges from 1 in 1,000,000 to 8 in 10,000.

54 ENVIRONMENTAL SCIENCES↗

Solvated Electron Technology{sup TM}. Non-Thermal Alternative to Waste Incineration

Solvated Electron Technology (SET{sup TM}) is a patented non-thermal alternative to incineration for treating Toxic Substances Control Act (TSCA) and other mixed waste by destroying organic hazardous components. SET{sup TM} is a treatment process that destroys the hazardous components in mixed waste by chemical reduction. The residual material meets land disposal restriction (LDR) and TSCA requirements for disposal. In application, contaminated materials are placed into a treatment cell and mixed with the solvated electron solution. In the case of PCBs or other halogenated contaminants, chemical reactions strip the halogen ions from the chain or aromatic ring producing sodium chloride and high molecular weight hydrocarbons. At the end of the reaction, ammonia within the treatment cell is removed and recycled. The reaction products (such as sodium salts) produced in the process remain with the matrix. The SET{sup TM} process is 99.999% effective in destroying: polychlorinated biphenyls (PCBs); trichloroethane (TCA) and trichloroethene (TCE); dioxins; polycyclic aromatic hydrocarbons (PAHs); benzene, toluene, xylene (BTX); pesticides; fungicides; herbicides; chlorofluorocarbons (CFCs); hydro-chlorofluorocarbons (HCFCs), explosives and chemical-warfare agents; and has successfully destroyed many of the wastes listed in 40 Code of Federal Regulations (CFR) 261. In September 2007, U.S. Environmental Protection Agency (EPA) issued a Research and Development permit for SET for chemical destruction of 'pure' Pyranol, which is 60% PCBs. These tests were completed in November 2007. SET{sup TM} is recognized by EPA as a non-thermal process equivalent to incineration and three SET{sup TM} systems have been permitted by EPA as commercial mobile PCB destruction units. This paper describes in detail the results of select bench-, pilot-, and commercial-scale treatment of hazardous and mixed wastes for EPA, Department of Energy (DOE), and the Department of Defense(DoD), and the applicability of SET{sup TM} to currently problematic waste streams that have very limited treatment alternatives. In summary: SET{sup TM} operates as a non-thermal destruction process under low pressure. The process occurs in a closed system producing no hazardous off-gases and no regulated by-products such as dioxins or furans or their precursors. Advantages of SET{sup TM} include: - Organic contaminants are destroyed, not just removed, diluted or concentrated. - Operates as a closed system - produces no regulated secondary wastes. - Holds an EPA permit for PCB destruction. - Operates at ambient temperatures (70 deg. F). - Portable and sets up quickly in less than 4000 square feet of space. - Scalable to accommodate any size waste stream. - Requires minimal amounts of power, water and infrastructure. - Applicable to heterogeneous waste streams in all phases. The SET{sup TM} process is 99.9999% effective in destroying organic constituents of RCRA and TSCA waste, explosives and chemical-warfare agents; and has successfully destroyed many of the wastes listed in 40 Code of Federal Regulations (CFR) 261. The residual material meets land disposal restriction (LDR) and TSCA requirements for disposal. In November 2007, Commodore completed a treatability study on Pyranol to determine the effectiveness of SET{sup TM} treatment on oil containing 600,000 PPM PCBs. Laboratory results proved destruction of PCBs to less than 1 PPM at low temperatures and pressures. SET{sup TM} is a proven, safe and cost-effective alternative to incineration for some of the most difficult waste treatment problems that exist today. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Polyphosphate Remediation Technology for In-Situ Stabilization of Uranium

A labortory testing program has been conducted to optimize polyphosphate remediation technology for implementation through a field-scale technology infiltration demonstration to stabilize soluble, uranium-bearing source phases in the vadose zone and capillary fringe. Source treatment in the deep vadose zone will accelerate the natural attenuation of uranium to more thermodynamically stable uranium-phosphate minerals, enhancing the performance of the proposed polyphosphate remediation within the 300 Area aquifer. The objective of this investigation was to develop polyphosphate remediation technology to treat uranium contamination contained within the deep vadose zone and capillary fringe. This paper presents the results of an investigation that evaluated the rate and extent of reaction between polyphosphate and the uranium mineral phases present within the 300 Area vadose zone and capillary fringe and autunite formation as a function of polyphosphate formulation and concentration. This information is critical for identifying the optimum implementation approach and controlling the flux of uranium from the vadose zone and capillary fringe to the underlying aquifer during remediation. Results from this investigation will be used to design a full-scale remediation of uranium at the 300 Area of the Hanford Site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Arsenic cycling within the water column of a small lake receiving contaminated ground-water discharge

The fate of arsenic discharged from contaminated ground water to a small, shallow lake at a hazardous waste site was examined to understand the role of iron (hydr)oxide precipitation-dissolution processes within the water column. Field and laboratory observations indicate that arsenic solubility was controlled, in part, by the extent of ferrous iron oxidation-precipitation and arsenic sorption occurring near the lake chemocline. Laboratory experiments were conducted using site-derived water to assess the impact of these coupled processes on the removal of dissolved arsenic from the water column. The measured concentration of organic carbon from epilimnetic and hypolimnetic water sampled from the lake was approximately 1.3 mM and 17.0 mM, respectively. Experiments conducted with these samples along with synthetic controls containing no organic carbon demonstrated that observed rates of formation and crystallinity of the precipitated iron (hydr)oxide were dependent on the concentration of organic carbon in the lake water. Increasing dissolved organic matter concentration did not significantly interfere with ferrous iron oxidation, but inhibited iron (hydr)oxide precipitation and subsequent sorption of arsenic. For experiments using water sampled from the lake hypolimnion there was a strong relationship between the fraction of precipitated iron and the fraction of sorbed arsenic. Laboratory- and field-derived iron (hydr)oxide precipitates were characterized to evaluate mineralogy and arsenic distribution. In-situ suspended solids and precipitates formed in laboratory experiments using hypolimnetic water were identified as poorly crystalline 2-line ferrihydrite. These solids were readily dissolved in the presence of dithionite indicating that elevated dissolved iron and arsenic observed in the hypolimnion resulted, in part, from in-situ reductive dissolution of settling 2-line ferrihydrite near the sediment-water interface. These observations support the contention that the levels of dissolved arsenic observed in the shallow lake can be attributed to ground-water discharge and internal recycling of arsenic within the water column. The efficiency of the process resulting in iron (hydr)oxide precipitation and arsenic sorption limits the downgradient export of arsenic derived from ground-water discharge.

54 ENVIRONMENTAL SCIENCES↗

Methylmercury sorption onto engineered materials

Four commercially available sorbents (BioChar (BC), ThiolSAMMS® (TS), SediMite (SM), and Organoclay™ PM-199 (OC-199)) were tested for their ability to sorb methylmercury (MeHg) and MeHg complexed with dissolved organic matter (DOM). Testing sorption behavior with DOM is more representative of the environmental conditions and mercury speciation expected during in-situ remediation efforts. Isotherms were fit using a robust, iterative re-weighting scheme. This fitting method improves upon the traditionally used indirect sorption method by removing the dependence between aqueous and solid phase concentrations in isotherm fitting. Developed isotherms reflect that without DOM, BC, TS, and SM adsorbed similar amounts of MeHg while OC-199 sorbed substantially less MeHg. Below an equilibrium concentration of 5.6 ng L -1 BC was the best performing sorbent, between 5.6 and 20. ng L -1 SM sorbed the most MeHg, and above an equilibrium concentration of 20.9 ng L -1 TS outperformed the other sorbents. BC and OC-199 showed indication of MeHg sorption saturation over the tested concentration range of 3.5–680 ng L -1 . With DOM, SM outperformed the other sorbents at equilibrium concentrations less than 0.98 ng L -1 and TS was the superior MeHg:DOM sorbent at higher concentrations. MeHg:DOM sorption was controlled by DOM-sorbent interactions. DOM decreased MeHg sorption onto BC and SM whereas TS exhibited similar sorption with and without DOM. OC-199 had slightly higher MeHg uptake with DOM. East Fork Poplar Creek (EFPC), an industrially Hg contaminated site, was used as a case study example to build a relationship between aqueous and fish MeHg concentrations and subsequently compare the cost of sorbent materials required to meet regulatory objectives. For this case study, SM provided the most cost-effective sorbent option for in-situ remediation efforts to reduce aqueous MeHg concentrations.

36 MATERIALS SCIENCE↗