Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Cities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Sitka Energy Inventory

The City and Borough of Sitka was chosen for an Energy Technology Innovation Partner Project award starting in Fall 2023, the third cohort of the program. The scope of the following work was driven by the city, as well as the city-appointed Sustainability Commission. The community asked for a method to track their reliance on outside fuel sources, as well as the emissions associated with those fuels and other processes in Sitka. The Pacific Northwest National Laboratory (PNNL) provided research and methodology in line with this community driven ask. This project is a community wide inventory, requiring methods to estimate the fuel usage and emissions from various industries. For each estimate, PNNL presents methodologies that can be repeated by the community in future years to understand how the city is changing.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

Extreme Decentralized Water Treatment: Exploring the Future of Premise-Scale Water Treatment and Reuse

Access to an adequate quantity of piped water and management of wastewater produced in homes and businesses is an expectation of city dwellers in wealthy countries, and an aspiration for many people living in rapidly developing cities in low- and middle-income countries. It is also crucial to public health and protection of the environment. For well over a century, municipal drinking water provision and wastewater management have been made possible by large investments in centralized systems in which fresh water passes through a small number of drinking water treatment plants before being distributed through a vast underground pipe network to buildings throughout the city (Sedlak 2014). After it is used, wastewater is collected in underground sewers that route it to treatment plants prior to its discharge to the environment. In some water-stressed cities, a fraction of the treated wastewater undergoes additional treatment prior to reuse. This recycled water often is returned to users through another dedicated water distribution system, which is designated in many places with purple pipes (non-potable water reuse). Alternatively, treated wastewater may be subjected to advanced treatment (e.g., reverse osmosis followed by advanced oxidation) prior to being returned to the drinking water supply (potable water reuse).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In-use vehicle emissions in China: Beijing study

China's economic boom in the last three decades has spurred increasing demand for transportation services and personal mobility. Consequently, vehicle population has grown rapidly since the early 1990s, especially in megacities such as Beijing, Guangzhou, and Tianjin. As a result, mobile sources have become more conspicuous contributors to urban air pollution in Chinese cities. Tianjin was our first focus city, and the study there took us about two years to complete. Building upon the experience and partnership generated through the Tianjin study, the research team carried out the Beijing study from fall 2007–fall 2008. Beijing was chosen to be our second focus city for several reasons: it has the largest local fleet and the highest percentage of the population owning vehicles among all Chinese cities, and it has suffered from severe air pollution, partially due to the ever-growing population of on-road vehicles.

02 PETROLEUM↗

Jackson Park Hospital Green Building Medical Center

Jackson Park Hospital completed the construction of a new Medical Office Building on its campus this spring. The new building construction has adopted the City of Chicago's recent focus on protecting the environment, and conserving energy and resources, with the introduction of green building codes. Located in a poor, inner city neighborhood on the South side of Chicago, Jackson Park Hospital has chosen green building strategies to help make the area a better place to live and work. The new green building houses the hospital's Family Medicine Residency Program and Specialty Medical Offices. The residency program has been vital in attracting new, young physicians to this medically underserved area. The new outpatient center will also help to allure needed medical providers to the community. The facility also has areas designated to women's health and community education. The Community Education Conference Room will provide learning opportunities to area residents. Emphasis will be placed on conserving resources and protecting our environment, as well as providing information on healthcare access and preventive medicine. The new Medical Office Building was constructed with numerous energy saving features. The exterior cladding of the building is an innovative, locally-manufactured precast concrete panel system with integral insulation that achieves an R-value in excess of building code requirements. The roof is a 'green roof' covered by native plantings, lessening the impact solar heat gain on the building, and reducing air conditioning requirements. The windows are low-E, tinted, and insulated to reduce cooling requirements in summer and heating requirements in winter. The main entrance has an air lock to prevent unconditioned air from entering the building and impacting interior air temperatures. Since much of the traffic in and out of the office building comes from the adjacent Jackson Park Hospital, a pedestrian bridge connects the two buildings, further decreasing the amount of unconditioned air that enters the office building. The HVAC system has an Energy Efficiency Rating 29% greater than required. No CFC based refrigerants were used in the HVAC system, thus reducing the emission of compounds that contribute to ozone depletion and global warming. In addition, interior light fixtures employ the latest energy-efficient lamp and ballast technology. Interior lighting throughout the building is operated by sensors that will automatically turn off lights inside a room when the room is unoccupied. The electrical traction elevators use less energy than typical elevators, and they are made of 95% recycled material. Further, locally manufactured products were used throughout, minimizing the amount of energy required to construct this building. The primary objective was to construct a 30,000 square foot medical office building on the Jackson Park Hospital campus that would comply with newly adopted City of Chicago green building codes focusing on protecting the environment and conserving energy and resources. The energy saving systems demonstrate a state of the-art whole-building approach to energy efficient design and construction. The energy efficiency and green aspects of the building contribute to the community by emphasizing the environmental and economic benefits of conserving resources. The building highlights the integration of Chicago's new green building codes into a poor, inner city neighborhood project and it is designed to attract medical providers and physicians to a medically underserved area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States

Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and residential building stock. The End-Use Load Profiles project website includes links to data viewers for this new dataset. For documentation of dataset validation, model calibration, and uncertainty quantification, see Wilson et al. (2022). These data were first created around 2012 as a byproduct of various analyses of solar photovoltaics and solar water heating (see references below for are two examples). This dataset contains several errors and limitations. It is recommended that users of this dataset transition to the updated version of the dataset posted in the resources. This dataset contains weather data, commercial load profile data, and residential load profile data. Weather The Typical Meteorological Year 3 (TMY3) provides one year of hourly data for around 1,000 locations. The TMY weather represents 30-year normals, which are typical weather conditions over a 30-year period. Commercial The commercial load profiles included are the 16 ASHRAE 90.1-2004 DOE Commercial Prototype Models simulated in all TMY3 locations, with building insulation levels changing based on ASHRAE 90.1-2004 requirements in each climate zone. The folder names within each resource represent the weather station location of the profiles, whereas the file names represent the building type and the representative city for the ASHRAE climate zone that was used to determine code compliance insulation levels. As indicated by the file names, all building models represent construction that complied with the ASHRAE 90.1-2004 building energy code requirements. No older or newer vintages of buildings are represented. Residential The BASE residential load profiles are five EnergyPlus models (one per climate region) representing 2009 IECC construction single-family detached homes simulated in all TMY3 locations. No older or newer vintages of buildings are represented. Each of the five climate regions include only one heating fuel type; electric heating is only found in the Hot-Humid climate. Air conditioning is not found in the Marine climate region. One major issue with the residential profiles is that for each of the five climate zones, certain location-specific algorithms from one city were applied to entire climate zones. For example, in the Hot-Humid files, the heating season calculated for Tampa, FL (December 1 - March 31) was unknowingly applied to all other locations in the Hot-Humid zone, which restricts heating operation outside of those days (for example, heating is disabled in Dallas, TX during cold weather in November). This causes the heating energy to be artificially low in colder parts of that climate zone, and conversely the cooling season restriction leads to artificially low cooling energy use in hotter parts of each climate zone. Additionally, the ground temperatures for the representative city were used across the entire climate zone. This affects water heating energy use (because inlet cold water temperature depends on ground temperature) and heating/cooling energy use (because of ground heat transfer through foundation walls and floors). Representative cities were Tampa, FL (Hot-Humid), El Paso, TX (Mixed-Dry/Hot-Dry), Memphis, TN (Mixed-Humid), Arcata, CA (Marine), and Billings, MT (Cold/Very-Cold). The residential dataset includes a HIGH building load profile that was intended to provide a rough approximation of older home vintages, but it combines poor thermal insulation with larger house size, tighter thermostat setpoints, and less efficient HVAC equipment. Conversely, the LOW building combines excellent thermal insulation with smaller house size, wider thermostat setpoints, and more efficient HVAC equipment. However, it is not known how well these ...

Array↗

Modeling Organic Aerosols in a Megacity: Comparison of Simple and Complex Representations of the Volatility Basis Set Approach

The Weather Research and Forecasting model coupled with chemistry (WRF-Chem) is modified to include a volatility basis set (VBS) treatment of secondary organic aerosol formation. The VBS approach, coupled with SAPRC-99 gas-phase chemistry mechanism, is used to model gas-particle partitioning and multiple generations of gas-phase oxidation of organic vapors. In addition to the detailed 9-species VBS, a simplified mechanism using 2 volatility species (2-species VBS) is developed and tested for similarity to the 9-species VBS in terms of both mass and oxygen-to-carbon ratios of organic aerosols in the atmosphere. WRF-Chem results are evaluated against field measurements of organic aerosols collected during the MILAGRO 2006 campaign in the vicinity of Mexico City. The simplified 2-species mechanism reduces the computational cost by a factor of 2 as compared to 9-species VBS. Both ground site and aircraft measurements suggest that the 9-species and 2-species VBS predictions of total organic aerosol mass as well as individual organic aerosol components including primary, secondary, and biomass burning are comparable in magnitude. In addition, oxygen-to-carbon ratio predictions from both approaches agree within 25%, providing evidence that the 2-species VBS is well suited to represent the complex evolution of organic aerosols. Model sensitivity to amount of anthropogenic semi-volatile and intermediate volatility (S/IVOC) precursor emissions is also examined by doubling the default emissions. Both the emission cases significantly under-predict primary organic aerosols in the city center and along aircraft flight transects. Secondary organic aerosols are predicted reasonably well along flight tracks surrounding the city, but are consistently over-predicted downwind of the city. Also, oxygen-to-carbon ratio predictions are significantly improved compared to prior studies by adding 15% oxygen mass per generation of oxidation; however, all modeling cases still under-predict these ratios downwind as compared to measurements, suggesting a need to further improve chemistry parameterizations of secondary organic aerosol formation.

09 BIOMASS FUELS↗

Spectro-Microscopic Measurements of Carbonaceous Aerosol Aging in Central California

Carbonaceous aerosols are responsible for large uncertainties in climate models, degraded visibility, and adverse health effects. The Carbonaceous Aerosols and Radiative Effects Study (CARES) was designed to study carbonaceous aerosols in the natural environment of Central Valley, California, and learn more about their atmospheric formation and aging. This paper presents results from spectro-microscopic measurements of carbonaceous particles collected during CARES at the time of pollution accumulation event (June 27-29, 2010), when in situ measurements indicated an increase in the organic carbon content of aerosols as the Sacramento urban plume aged. Computer controlled scanning electron microscopy coupled with an energy dispersive X-ray detector (CCSEM/EDX) and scanning transmission X-ray microscopy coupled with near edge X-ray absorption spectroscopy (STXM/NEXAFS) were used to probe the chemical composition and morphology of individual particles. It was found that the mass of organic carbon on individual particles increased through condensation of secondary organic aerosol. STXM/NEXAFS indicated that the number fraction of homogenous organic particles lacking inorganic inclusions (greater than ~50 nm diameter) increased with plume age as did the organic mass per particle. Comparison of the CARES spectro-microscopic data set with a similar dataset obtained in Mexico City during the MILAGRO campaign showed that individual particles in Mexico City contained twice as much carbon as those sampled during CARES. The number fraction of soot particles at the Mexico City urban site (30%) was larger than at the CARES urban site (10%) and the most aged samples from CARES contained less carbon-carbon double bonds. Differences between carbonaceous particles in Mexico City and California result from different sources, photochemical conditions, gas phase reactants, and secondary organic aerosol precursors. The detailed results provided by these spectro-microscopic measurements will allow for a comprehensive evaluation of aerosol process models used in climate research.

Environmental Molecular Sciences Laboratory↗

Detection and variability of combustion-derived vapor in an urban basin

Abstract. Water emitted during combustion may comprise a significant portion of ambient humidity (> 10 %) in urban areas, where combustion emissions are strongly focused in space and time. Stable water vapor isotopes can be used to apportion measured humidity values between atmospherically transported and combustion-derived water vapor, as combustion-derived vapor possesses an unusually negative deuterium excess value (d-excess, d = δ 2 H − 8 δ 18 O). We investigated the relationship between the d-excess of atmospheric vapor, ambient CO 2 concentrations, and atmospheric stability across four winters in Salt Lake City, Utah. We found a robust inverse relationship between CO 2 excess above background and d-excess on sub-diurnal to seasonal timescales, which was most prominent during periods of strong atmospheric stability that occur during Salt Lake City winter. Using a Keeling-style mixing model approach, and assuming a molar ratio of H 2 O to CO 2 in emissions of 1.5, we estimated the d-excess of combustion-derived vapor in Salt Lake City to be −179 ± 17 ‰, consistent with the upper limit of theoretical estimates. Based on this estimate, we calculate that vapor from fossil fuel combustion often represents 5–10 % of total urban humidity, with a maximum estimate of 16.7 %, consistent with prior estimates for Salt Lake City. Moreover, our analysis highlights that changes in the observed d-excess during periods of high atmospheric stability cannot be explained without a vapor source possessing a strongly negative d-excess value. Further refinements in this humidity apportionment method, most notably empirical validation of the d-excess of combustion vapor or improvements in the estimation of the background d-excess value in the absence of combustion, can yield more certain estimates of the impacts of fossil fuel combustion on urban humidity and meteorology.

54 ENVIRONMENTAL SCIENCES↗

Community-Informed Urban Flood Modeling for Impact Mitigation

The intensification of the hydrologic cycle due to climate change poses a threat to aging and under-designed water infrastructure systems which cannot adequately manage intense storm events. Developing a comprehensive plan for managing rain-driven flooding events is challenging due to uncertainties in the magnitude and frequency of future storm events and conflicting stakeholder objectives. In the City of Baltimore, Maryland, stormwater infrastructure is struggling to keep up with rainfall-driven (pluvial) flooding events, which regularly damage housing and disrupt transportation for residents. In this study, a hybrid of community engagement, numerical modeling, and artificial intelligence techniques are employed to explore prospective urban flooding adaptations. Community engagement drives the development of an urban flooding model (EPA Storm Water Management Model) for the Baltimore Harbor watershed. The model integrates complex surface and subsurface stormwater infrastructure data from the City, high-resolution spatial data, insights from local public works experts, and the lived experiences of City residents. This co-developed model simulates adaptations of interest to stakeholders in the city, including green and grey infrastructure and operational management strategies. Stormwater management scenarios focused on inlet cleaning and spatially concentrated green infrastructure are found to be the most effective in reducing flood depths in community priority locations. Together, these adaptations can reduce the duration of intersection inundation by more than twenty minutes, allowing for quicker emergency response and restoration of typical transportation systems. Future work will combine this community engaged flooding model with the Deep Uncertainties Pathways framework to explore tradeoffs between adaptations and develop dynamic adaptations which align with community objectives, enhance climate resilience in Baltimore, and can be adjusted in response to changing future conditions.

Ava, Spangler [Pennsylvania State University]↗

LANDSAT (MSS): Image demographic estimations

The author has identified the following significant results. Two sets of urban test sites, one with 35 cities and one with 70 cities, were selected in the State, Sao Paulo. A high degree of colinearity (0.96) was found between urban and areal measurements taken from aerial photographs and LANDSAT MSS imagery. High coefficients were observed when census data were regressed against aerial information (0.95) and LANDSAT data (0.92). The validity of population estimations was tested by regressing three urban variables, against three classes of cities. Results supported the effectiveness of LANDSAT to estimate large city populations with diminishing effectiveness as urban areas decrease in size.

Dejesusparada, N.↗

The 30/20 GHz communications satellite trunking network study

Alternative transmission media for a CONUS-wide trunking network in the years 1990 and 2000 are examined. The alternative technologies comprised fiber optic cable, conventional C- and Ku-band satellites, and 30/20 GHz satellites. Three levels of implementation were considered - a 10-city network, a 20-city network, and a 40-city network. The cities selected were the major metropolitan areas with the greatest communications demand. All intercity voice, data, and video traffic carried more than 40 miles was included in the analysis. In the optimized network, traffic transmitted less than 500 miles was found to be better served by fiber optic cable in 1990. By the year 2000, the crossover point would be down to 200 miles, assuming availability of 30/20 GHz satellites.

Kolb, W.↗

Measuring Thermal Characteristics of Urban Landscapes

The additional heating of the air over the city is the result of the replacement of naturally vegetated surfaces with those composed of asphalt, concrete, rooftops and other man-made materials. The temperatures of these artificial surfaces can be 20 to 40 C higher than vegetated surfaces. Materials such as asphalt store much of the sun's energy and remains hot long after sunset. This produces a dome of elevated air temperatures 5 to 8 C greater over the city, compared to the air temperatures over adjacent rural areas. This effect is called the "urban heat island". Urban landscapes are a complex mixture of vegetated and nonvegetated surfaces. It is difficult to take enough temperature measurements over a large city area to characterize the complexity of urban radiant surface temperature variability. However, the use of remotely sensed thermal data from airborne scanners are ideal for the task. In a study funded by NASA, a series of flights over Huntsville, Alabama were performed in September 1994 and over Atlanta, Georgia in May 1997. Analysis of thermal energy responses for specific or discrete surfaces typical of the urban landscape (e.g., asphalt, building rooftops, vegetation) requires measurements at a very fine spatial scale (i.e., <15 m) to adequately resolve these surfaces and their attendant thermal energy regimes. Additionally, very fine scale spatial resolution thermal infrared data, such as that obtained from aircraft, are very useful for demonstrating to planning officials, policy makers, and the general populace, what the benefits are of the urban forest in both mitigating the urban heat island effect, in making cities more aesthetically pleasing and more habitable environments, and in overall cooling of the community. In this presentation we will examine the techniques of analyzing remotely sensed data for measuring the effect of various urban surfaces on their contribution to the urban heat island effect.

Luvall, Jeffrey C.↗

A Decision Support Information System for Urban Landscape Management Using Thermal Infrared Data

In this paper, we describe efforts to use remote sensing data within the purview of an information support system, to assess urban thermal landscape characteristics as a means for developing more robust models of the Urban Heat Island (UHI) effect. We also present a rationale on how we have successfully translated the results from the study of urban thermal heating and cooling regimes as identified from remote sensing data, to decision-makers, planners, government officials, and the public at large in several US cities to facilitate better understanding of how the UHI affects air quality. Additionally, through the assessment of the spatial distribution of urban thermal landscape characteristics using remote sensing data, it is possible to develop strategies to mitigate the UHI that hopefully will in turn, drive down ozone levels and improve overall urban air quality. Four US cities have been the foci for intensive analysis as part of our studies: Atlanta, GA, Baton Rouge, LA, Salt Lake City, UT, and Sacramento, CA. The remote sensing data for each of these cities has been used to generate a number of products for use by "stakeholder" working groups to convey information on what the effects are of the UHI and what measures can be taken to mitigate it. In turn, these data products are used to both educate and inform policy-makers, planners, and the general public about what kinds of UHI mitigation strategies are available.

Quattrochi, Dale A.↗

Space-Derived Sewer Monitor

The QuadraScan Longterm Flow Monitoring System is a second generation sewer monitor developed by American Digital Systems, Inc.'s founder Peter Petroff. Petroff, a former spacecraft instrumentation designer at Marshall Space Flight Center, used expertise based on principles acquired in Apollo and other NASA programs. QuadraScan borrows even more heavily from space technology, for example in its data acquisition and memory system derived from NASA satellites. "One-time" measurements are often plagued with substantial errors due to the flow of groundwater absorbed into the system. These system sizing errors stem from a basic informational deficiency: accurate, reliable data on how much water flows through a sewer system over a long period of time is very difficult to obtain. City officials are turning to "permanent," or long-term sewer monitoring systems. QuadraScan offers many advantages to city officials such as the early warning capability to effectively plan for city growth in order to avoid the crippling economic impact of bans on new sewer connections in effect in many cities today.

Source record↗

Rainfall Modification by Urban Areas: New Perspectives from TRMM

Data from the Tropical Rainfall Measuring Mission's (TRMM) Precipitation Radar (PR) were employed to identify warm season rainfall (1998-2000) patterns around Atlanta, Montgomery, Nashville, San Antonio, Waco, and Dallas. Results reveal an average increase of -28% in monthly rainfall rates within 30-60 kilometers downwind of the metropolis with a modest increase of 5.6% over the metropolis. Portions of the downwind area exhibit increases as high as 51%. The percentage changes are relative to an upwind control area. It was also found that maximum rainfall rates in the downwind impact area exceeded the mean value in the upwind control area by 48% - 116%. The maximum value was generally found at an average distance of 39 km from the edge of the urban center or 64 km from the center of the city. Results are consistent with METROMEX studies of St. Louis almost two decades ago and with more recent studies near Atlanta. Future work is extending the investigation to Phoenix, Arizona, an arid U.S. city, and several international cities like Mexico City, Johannesburg, and Brasilia. The study establishes the possibility of utilizing satellite-based rainfall estimates for examining rainfall modification by urban areas on global scales and over longer time periods. Such research has implications for weather forecasting, urban planning, water resource management, and understanding human impact on the environment and climate.

Shepherd, J. Marshall↗

The Urban Heat Island Phenomenon: How Its Effects Can Influence Environmental Decision Making in Your Community

Reinvestment in urban centers is breathing new life into neighborhoods that have been languishing as a result of explosive suburban development over the past several decades. In cities all over the country, adaptive reuse, brownfields redevelopment, transforming urban landscapes, economies, and quality of life. However, the way in which this development occurs has the potential to exacerbate the urban heat island (UHI) phenomenon, an existing problem in many areas and one which poses a threat to the long-term sustainability and environmental quality of cities. The UHI phenomenon is rooted in the science of how the land covers respond to solar heating and can adversely effect the environment. This phenomenon is responsible for urban centers having higher air temperatures and poorer air quality than suburban areas. In addition, the UHI phenomenon causes metrological occurrences, degrades water quality, increases energy demands, poses threats to public health and contributes to global warming. While the name of the phenomenon implies that is solely an urban issue, research has shown that the effects of the UHI are becoming prevalent in suburbs, as well. The UHI phenomenon can plague regions - urban centers and their suburbs. Furthermore, heat islands have been found to exist in both city centers and suburban communities. As suburban areas increasingly develop using land covers and building materials common to urban areas, they are inheriting urban problems - such as heat islands. In this way, it may be necessary for non-urban communities to engage in heat island mitigation. The good news is that through education and planning, the effects of the UHI phenomenon can be prevented and mitigated. Heat islands are more a product of urban design rather than the density of development. Therefore, cities can continue to grow and develop without exacerbating the UHI by employing sustainable development strategies.

Estes, Maurice G., Jr.↗

Evidence of Urban Precipitation Anomalies from Satellite and Ground-Based Measurements

Urbanization is one of the extreme cases of land use change. Most of world s population has moved to urban areas. Although currently only 1.2% of the land is considered urban, the spatial coverage and density of cities are expected to rapidly increase in the near future. It is estimated that by the year 2025,60% of the world s population will live in cities. Human activity in urban environments also alters weather and climate processes. However, our understanding of urbanization on the total Earth-weather-climate system is incomplete. Recent literature continues to provide evidence that anomalies in precipitation exist over and downwind of major cities. Current and future research efforts are actively seeking to verify these literature findings and understand potential cause- effect relationships. The novelty of this study is that it utilizes rainfall data from multiple satellite data sources (e.g. TRMM precipitation radar, TRMM-geosynchronous-rain gauge merged product, and SSM/I) and ground-based measurements to identify spatial anomalies and temporal trends in precipitation for cities around the world. Early results will be presented and placed within the context of weather prediction, climate assessment, and societal applications.

Shepherd, J. M.↗