Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONVERTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

10 ps resolution, 160 ns full scale range and less than 1.5% differential non-linearity time-to-digital converter module for high performance timing measurements

We present a compact high performance time-to-digital converter (TDC) module that provides 10 ps timing resolution, 160 ns dynamic range and a differential non-linearity better than 1.5% LSB{sub rms}. The TDC can be operated either as a general-purpose time-interval measurement device, when receiving external START and STOP pulses, or in photon-timing mode, when employing the on-chip SPAD (single photon avalanche diode) detector for detecting photons and time-tagging them. The instrument precision is 15 ps{sub rms} (i.e., 36 ps{sub FWHM}) and in photon timing mode it is still better than 70 ps{sub FWHM}. The USB link to the remote PC allows the easy setting of measurement parameters, the fast download of acquired data, and their visualization and storing via an user-friendly software interface. The module proves to be the best candidate for a wide variety of applications such as: fluorescence lifetime imaging, time-of-flight ranging measurements, time-resolved positron emission tomography, single-molecule spectroscopy, fluorescence correlation spectroscopy, diffuse optical tomography, optical time-domain reflectometry, quantum optics, etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A mode converter to generate a Gaussian-like mode for injection into the VENUS electron cyclotron resonance ion source

A number of superconducting electron cyclotron resonance (ECR) ion sources use gyrotrons at either 24 or 28 GHz for ECR heating. In these systems, the microwave power is launched into the plasma using the TE{sub 01} circular waveguide mode. This is fundamentally different and may be less efficient than the typical rectangular, linearly polarized TE{sub 10} mode used for launching waves at lower frequencies. To improve the 28 GHz microwave coupling in VENUS, a TE{sub 01}-HE{sub 11} mode conversion system has been built to test launching HE{sub 11} microwave power into the plasma chamber. The HE{sub 11} mode is a quasi-Gaussian, linearly polarized mode, which should couple strongly to the plasma electrons. The mode conversion is done in two steps. First, a 0.66 m long “snake” converts the TE{sub 01} mode to the TE{sub 11} mode. Second, a corrugated circular waveguide excites the HE{sub 11} mode, which is launched directly into the plasma chamber. The design concept draws on the development of similar devices used in tokamaks and stellerators. The first tests of the new coupling system are described below.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic defects in chemically converted graphene nanoribbons: electron spin resonance investigation

Electronic spin transport properties of graphene nanoribbons (GNRs) are influenced by the presence of adatoms, adsorbates and edge functionalization. To improve the understanding of the factors that influence the spin properties of GNRs, local (element) spin-sensitive techniques such as electron spin resonance (ESR) spectroscopy are important for spintronics applications. Here, we present results of multi-frequency continuous wave (CW), pulse and hyperfine sublevel correlation (HYSCORE) ESR spectroscopy measurements performed on oxidatively unzipped graphene nanoribbons (GNRs), which were subsequently chemically converted (CCGNRs) with hydrazine. ESR spectra at 336 GHz reveal an isotropic ESR signal from the CCGNRs, of which the temperature dependence of its line width indicates the presence of localized unpaired electronic states. Upon functionalization of CCGNRs with 4-nitrobenzene diazonium tetrafluoroborate, the ESR signal is found to be 2 times narrower than that of pristine ribbons. NH{sub 3} adsorption/desorption on CCGNRs is shown to narrow the signal, while retaining the signal intensity and g value. The electron spin-spin relaxation process at 10 K is found to be characterized by slow (163 ns) and fast (39 ns) components. HYSCORE ESR data demonstrate the explicit presence of protons and {sup 13}C atoms. With the provided identification of intrinsic point magnetic defects such as proton and {sup 13}C has been reported, which are roadblocks to spin travel in graphene-based materials, this work could help in advancing the present fundamental understanding on the edge-spin (or magnetic)-based transport properties of CCGNRs.

36 MATERIALS SCIENCE↗

AlGaAs/GaAs photovoltaic converters for high power narrowband radiation

AlGaAs/GaAs-based laser power PV converters intended for operation with high-power (up to 100 W/cm{sup 2}) radiation were fabricated by LPE and MOCVD techniques. Monochromatic (λ = 809 nm) conversion efficiency up to 60% was measured at cells with back surface field and low (x = 0.2) Al concentration 'window'. Modules with a voltage of 4 V and the efficiency of 56% were designed and fabricated.

14 SOLAR ENERGY↗

Proposal for efficient mode converter based on cavity quantum electrodynamics dark mode in a semiconductor quantum dot coupled to a bimodal microcavity

The ability to engineer and convert photons between different modes in a solid-state approach has extensive technological implications not only for classical communication systems but also for future quantum networks. In this paper, we put forward a scheme for coherent mode conversion of optical photons by utilizing the intermediate coupling between a single quantum dot and a bimodal photonic crystal microcavity via a waveguide. Here, one mode of the photonic crystal microcavity is coherently driven by an external single-frequency continuous-wave laser field and the two cavity modes are not coupled to each other due to their orthogonal polarizations. The undriven cavity mode is thus not directly coupled to the input driving laser and the only way it can get light is via the quantum dot. The influences of the system parameters on the photon-conversion efficiency are analyzed in detail in the limit of weak probe field and it is found that high photon-conversion efficiency can be achieved under appropriate conditions. It is shown that the cavity dark mode, which is a superposition of the two optical modes and is decoupled from the quantum dot, can appear in such a hybrid optical system. We discuss the properties of the dark mode and indicate that the formation of the dark mode enables the efficient transfer of optical fields between the two cavity modes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

1 ns time to digital converters for the KM3NeT data readout system

The KM3NeT collaboration aims at the construction of a multi-km3 high-energy neutrino telescope in the Mediterranean Sea consisting of thousands of glass spheres (nodes), each of them containing 31 photomultiplier (PMT) of small photocathode area. The readout and data acquisition system of KM3NeT has to collect, treat and send to shore, in an economic way, the enormous amount of data produced by the photomultipliers. For this purpose, 31 high-resolution time-interval measuring channels are implemented on the Field-Programmable Gate Arrays (FPGA) based on Time to Digital Converter (TDC). TDC are very common devices in particles physics experiments. Architectures with low resources occupancy are desirable allowing the implementation of other instrumentation, communication and synchronization systems on the same device. The required resolution to measure both, time of flight and timestamp must be 1 ns. A 4-Oversampling technique with two high frequency clocks is used to achieve this resolution. The proposed TDC firmware is developed using very few resources in Xilinx Kintex-7.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cs-doped Mo as surface converter for H{sup −}/D{sup −} generation in negative ion sources: First steps and proof of principle

In a proof-of-principle study, molybdenum samples were implanted with a very small dose of Cs in order to test the properties of the compound as a surface converter for negative hydrogen ion production. First results on the properties of Cs doped Mo compounds show a reduction of the work function and a stable H{sup −} yield up to four hours in low density hydrogen plasma. The implanted Cs atoms were stable in the Mo lattice over one year for samples stored in vacuum and not exposed to the plasma. The surface H{sup −} generation mechanisms were identified and a comparison of the negative ion yield with pure Mo showed that the Cs doped Mo sample’s yield was much larger.

07 ISOTOPE AND RADIATION SOURCES↗

24 GHz microwave mode converter optimized for superconducting ECR ion source SECRAL

Over-sized round waveguide with a diameter about Ø33.0 mm excited in the TE{sub 01} mode has been widely adopted for microwave transmission and coupling to the ECR (Electron Cyclotron Resonance) plasma with the superconducting ECR ion sources operating at 24 or 28 GHz, such as SECRAL and VENUS. In order to study the impact of different microwave modes on ECRH (Electron Cyclotron Resonance Heating) efficiency and especially the production of highly charged ions, a set of compact and efficient TE{sub 01}-HE{sub 11} mode conversion and coupling system applicable to 24 GHz SECRAL whose overall length is 330 mm has been designed, fabricated and tested. Good agreements between off-line tests and calculation results have been achieved, which indicates the TE{sub 01}-HE{sub 11} converter meets the application design. The detailed results of the optimized coupling system will be presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a detector chain using a FPGA-based time-to-digital converter to reconstruct the three-dimensional coordinates of single particles at high flux

We report on the development of a novel FPGA-based time-to-digital converter and its implementation in a detection chain that records the coordinates of single particles along three dimensions. The detector is composed of micro-channel plates mounted on top of a cross delay line and connected to fast electronics. We demonstrate continuous recording of the timing signals from the cross delay line at rates up to 4.1 × 10{sup 6} s{sup −1} and three-dimensional reconstruction of the coordinates up to 3.2 × 10{sup 6} particles per second. From the imaging of a calibrated structure we measure the in-plane resolution of the detector to be 140(20) μm at a flux of 3 × 10{sup 5} particles per second. In addition, we analyze a method to estimate the resolution without placing any structure under vacuum, a significant practical improvement. While we use UV photons here, the results of this work apply to the detection of other kinds of particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Luminescent carbon quantum dots with high quantum yield as a single white converter for white light emitting diodes

Carbon quantum dots (CQDs) with high quantum yield (51.4%) were synthesized by a one-step hydrothermal method using thiosalicylic acid and ethylenediamine as precursor. The CQDs have the average diameter of 2.3 nm and possess excitation-independent emission wavelength in the range from 320 to 440 nm excitation. Under an ultraviolet (UV) excitation, the CQDs aqueous solutions emit bright blue fluorescence directly and exhibit broad emission with a high spectral component ratio of 67.4% (blue to red intensity to total intensity). We applied the CQDs as a single white-light converter for white light emitting diodes (WLEDs) using a UV-LED chip as the excitation light source. The resulted WLED shows superior performance with corresponding color temperature of 5227 K and the color coordinates of (0.34, 0.38) belonging to the white gamut.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

BODIPY star-shaped molecules as solid state colour converters for visible light communications

In this paper, we study a family of solid-state, organic semiconductors for visible light communications. The star-shaped molecules have a boron-dipyrromethene (BODIPY) core with a range of side arm lengths which control the photophysical properties. The molecules emit red light with photoluminescence quantum yields ranging from 22% to 56%. Thin films of the most promising BODIPY molecules were used as a red colour converter for visible light communications. The film enabled colour conversion with a modulation bandwidth of 73 MHz, which is 16 times higher than that of a typical phosphor used in LED lighting systems. A data rate of 370 Mbit/s was demonstrated using On-Off keying modulation in a free space link with a distance of ∼15 cm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A time-to-frequency converter for measuring the shape of short optical pulses

A time-to-frequency converter was constructed using an electro-optic phase modulator as a time lens, allowing the pulse shape in time to be transferred to the frequency domain. We used such a device to record the temporal shape of infrared pulses at a wavelength of 1053 nm (width about 7 ps) and compared these measurements to those made by using both a streak camera and an autocorrelator. This side-by-side comparison illustrates the benefits and limitations of each of the measurement methods. Numerical simulations were used to establish that our time-lens-based system can accurately measure the shape of infrared pulses between 3 ps and 12 ps. We also use our numerical model to determine how such a system can be modified to measure pulses whose width lies in the range of 1–30 ps, a range of interest for the OMEGA-EP laser at the Laboratory for Laser Energetics.

47 OTHER INSTRUMENTATION↗

Quasioptical modeling of wave beams with and without mode conversion. III. Numerical simulations of mode-converting beams

This work continues a series of papers where we propose an algorithm for quasi-optical modeling of electromagnetic beams with and without mode conversion. The general theory was reported in the first paper of this series, where a parabolic partial differential equation was derived for the field envelope that may contain one or multiple modes with close group velocities. In the second paper, we presented a corresponding code PARADE (PAraxial RAy DEscription) and its test applications to single-mode beams. Here, we report quasi-optical simulations of mode-converting beams for the first time. Here, we also demonstrate that PARADE can model splitting of two-mode beams. The numerical results produced by PARADE show good agreement with those of one-dimensional full-wave simulations and also with conventional ray tracing (to the extent that one-dimensional and ray-tracing simulations are applicable).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of multi neutron-to-gamma converter array for measuring time resolved ion temperature of inertial confinement fusion implosions

The ion temperature varying during inertial confinement fusion implosions changes the amount of Doppler broadening of the fusion products, creating subtle changes in the fusion neutron pulse as it moves away from the implosion. A diagnostic design to try to measure these subtle effects is introduced—leveraging the fast time resolution of gas Cherenkov detectors along with a multi-puck array that converts a small amount of the neutron pulse into gamma-rays, one can measure multiple snapshots of the neutron pulse at intermediate distances. Further, precise measurements of the propagating neutron pulse, specifically the variation in the peak location and the skew, could be used to infer time-evolved ion temperature evolved during peak compression.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Geometric and doping effects on radiative recombination in thin-film near-field energy converters

Modeling radiative recombination is crucial to the analysis of radiative energy converters. In this work, a local radiative recombination coefficient is defined and derived based on fluctuational electrodynamics that is applicable to thin-film cells in both the near field and far field. The predicted radiative recombination coefficient of an InAs cell deviates from the van Roosbroeck–Shockley relation when the thickness is less than 10 µm, and the difference exceeds fourfold with a 10 nm film. The local radiative recombination coefficient is orders of magnitude higher when an InAs cell is configured in the near field. The local radiative recombination coefficient reduces as the doping level approaches that of a degenerate semiconductor. The maximum output power and efficiency of a thermoradiative cell would be apparently overpredicted if the electroluminescence coefficient defined in this paper were taken as unity for heavily doped semiconductors.

Feng, Dudong↗

Simulation of the optical properties of surface nanostructures for photoacoustic converters

A computer model has been developed and a theoretical study has been performed for nanostructures in the form of a two-dimensional monolayer of nanoparticles of noble metals on an optical fibre end face. The parameters of nanostructure-based photoacoustic converters are chosen for different environments in order to provide a high light absorption coefficient, which, in turn, provides a maximally high conversion efficiency for ultrasound generation. It is established that efficient photoacoustic conversion can be implemented in a surface nanostructure composed of spherical gold nanoparticles, located on an optical fibre end face in water, in wide ranges of the nanostructure microscopic parameters. It is shown that the backscattering coefficient also turns out large in the case of resonance absorption; for this reason, one must provide optical isolation of a laser in use when designing photoacoustic generators. (nanostructures)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SRS converter – compressor of femtosecond ytterbium laser pulses

Stimulated Raman scattering (SRS) conversion of femtosecond pulses of an ytterbium laser at a wavelength of 1.03 μm is performed in compressed hydrogen under conditions of nonlinear phase modulation. Temporal compression of frequency-chirped Stokes pulses is carried out, as a result of which 400-fs laser pulses are converted into 27-fs Stokes pulses with a wavelength of 1.8 μm. An average Stokes power of 0.6 W is implemented at an average laser power of 6.3 W and a pulse repetition rate of 20 kHz. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutrinos secretly converting to lighter particles to please both KATRIN and the cosmos

Within the framework of the Standard Model of particle physics and standard cosmology, observations of the Cosmic Microwave Background (CMB) and Baryon Acoustic Oscillations (BAO) set stringent bounds on the sum of the masses of neutrinos. If these bounds are satisfied, the upcoming KATRIN experiment which is designed to probe neutrino mass down to ∼ 0.2 eV will observe only a null signal. We show that the bounds can be relaxed by introducing new interactions for the massive active neutrinos, making neutrino masses in the range observable by KATRIN compatible with cosmological bounds. Within this scenario, neutrinos convert to new stable light particles by resonant production of intermediate states around a temperature of T∼ keV in the early Universe, leading to a much less pronounced suppression of density fluctuations compared to the standard model.

79 ASTRONOMY AND ASTROPHYSICS↗