Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONSERVATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Feasibility Study of Economics and Performance of Solar Photovoltaics at the TechCity East Campus Resource Conservation and Recovery Act Site in Kingston, New York. A Study Prepared in Partnership with the Environmental Protection Agency for the RE-Powering America's Land Initiative: Siting Renewable Energy on Potentially Contaminated Land and Mine Sites

The U.S. Environmental Protection Agency (EPA), in accordance with the RE-Powering America's Land initiative, selected the TechCity East Campus site in Kingston, New York, for a feasibility study of renewable energy production. The National Renewable Energy Laboratory (NREL) provided technical assistance for this project. The purpose of this study is to assess the site for a possible photovoltaic (PV) system installation and estimate the cost, performance, and site impacts of different PV options. In addition, the report recommends financing options that could assist in the implementation of a PV system at the site.

14 SOLAR ENERGY↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Refrigeration Playbook. Heat Reclaim; Optimizing Heat Rejection and Refrigeration Heat Reclaim for Supermarket Energy Conservation

The purpose of this playbook and accompanying spreadsheets is to generalize the detailed CBP analysis and to put tools in the hands of experienced refrigeration designers to evaluate multiple applications of refrigeration waste heat reclaim across the United States. Supermarkets with large portfolios of similar buildings can use these tools to assess the impact of large-scale implementation of heat reclaim systems. In addition, the playbook provides best practices for implementing heat reclaim systems to achieve the best long-term performance possible. It includes guidance on operations and maintenance as well as measurement and verification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores in California. Predicted indoor air quality and energy consumption using a matrix of ventilation scenarios (Final Report)

Through mass-balance modeling of various ventilation scenarios that might satisfy the ASHRAE 62.1 Indoor Air Quality (IAQ) Procedure, we estimate indoor concentrations of contaminants of concern (COCs) in California “big box” stores, compare estimates to available thresholds, and for selected scenarios estimate differences in energy consumption. Findings are intended to inform decisions on adding performance-based approaches to ventilation rate (VR) standards for commercial buildings. Using multi-zone mass-balance models and available contaminant source rates, we estimated concentrations of 34 COCs for multiple ventilation scenarios: VRmin (0.04 cfm/ft 2 ), VRmax (0.24 cfm/ft 2 ), and VRmid (0.14 cfm/ft 2 ). We compared COC concentrations with available health, olfactory, and irritant thresholds. We estimated building energy consumption at different VRs using a previously developed EnergyPlus model. VRmax did control all contaminants adequately, but VRmin did not, and VRmid did so only marginally. Air cleaning and local ventilation near strong sources both showed promise. Higher VRs increased indoor concentrations of outdoor air pollutants. Lowering VRs in big box stores in California from VRmax to VRmid would reduce total energy use by an estimated 6.6% and energy costs by 2.5%. Reducing the required VRs in California’s big box stores could reduce energy use and costs, but poses challenges for health and comfort of occupants. Source removal, air cleaning, and local ventilation may be needed at reduced VRs, and even at current recommended VRs. Also, alternative ventilation strategies taking climate and season into account in ventilation schedules may provide greater energy cost savings than constant ventilation rates, while improving IAQ.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recommendations on Implementing the Energy Conservation Building Code in Visakhapatnam, AP, India

Visakhapatnam can play an important role in improving energy efficiency in its buildings by implementing ECBC. This document seeks to capture stakeholder recommendations on a road map for implementation, which can help all market players plan for implementation. Visakhapatnam also has an opportunity to serve as a role model for other Smart Cities and cities in general in India. The road map and steps that VUDA adopts to implement ECBC can provide helpful examples to these other cities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bound-Preserving Discontinuous Galerkin Methods for Conservative Phase Space Advection in Curvilinear Coordinates

We extend the positivity-preserving method of Zhang & Shu [49] to simulate the advection of neutral particles in phase space using curvilinear coordinates. The ability to utilize these coordinates is important for non-equilibrium transport problems in general relativity and also in science and engineering applications with specific geometries. The method achieves high-order accuracy using Discontinuous Galerkin (DG) discretization of phase space and strong stabilitypreserving, Runge-Kutta (SSP-RK) time integration. Special care in taken to ensure that the method preserves strict bounds for the phase space distribution function f; i.e., f ϵ [0, 1]. The combination of suitable CFL conditions and the use of the high-order limiter proposed in [49] is su cient to ensure positivity of the distribution function. However, to ensure that the distribution function satisfies the upper bound, the discretization must, in addition, preserve the divergencefree property of the phase space ow. Proofs that highlight the necessary conditions are presented for general curvilinear coordinates, and the details of these conditions are worked out for some commonly used coordinate systems (i.e., spherical polar spatial coordinates in spherical symmetry and cylindrical spatial coordinates in axial symmetry, both with spherical momentum coordinates). Results from numerical experiments - including one example in spherical symmetry adopting the Schwarzschild metric - demonstrate that the method achieves high-order accuracy and that the distribution function satisfies the maximum principle.

97 MATHEMATICS AND COMPUTING↗

Post-Closure Report for Closed Resource Conservation and Recovery Act Corrective Action Units, Nevada National Security Site, Nevada: For Calendar Year 2017, Revision 0

This report serves as the combined annual report for post-closure activities for the following closed corrective action units (CAUs): CAU 90, Area 2 Bitcutter Containment; CAU 91, Area 3 U-3fi Injection Well CAU 92, Area 6 Decon Pond Facility; CAU 110, Area 3 WMD U-3ax/bl Crater; CAU 111, Area 5 WMD Retired Mixed Waste Pits; and, CAU 112, Area 23 Hazardous Waste Trenches. The results of the inspections, a summary of maintenance activities, and an evaluation of monitoring data are presented in this report. Site inspections are conducted annually at CAUs 90, 91, and 112; semiannually at CAUs 92 and 110; and quarterly at CAU 111. Additional inspections are conducted at CAU 92 if precipitation occurs in excess of 1.0 inches in a 24-hour period and at CAU 111 if precipitation occurs in excess of 1.0 inch in a 24-hour period. Inspections include an evaluation of the condition of the units, including covers, fences, signs, gates, and locks. At CAU 110, soil moisture monitoring, vegetation evaluations, and subsidence surveys are conducted in addition to the visual inspections. At CAU 111, soil moisture monitoring, vegetation evaluations, subsidence surveys, direct radiation monitoring, air monitoring, radon flux monitoring, and groundwater monitoring are conducted. This report will address all monitoring items notes above except groundwater monitoring. Groundwater monitoring is documented in the Nevada National Security Site Data Report: Groundwater Monitoring Program Area 5 Radioactive Waste Management Site. All required inspections, maintenance, and monitoring were conducted in accordance with the post-closure requirements of the permit. Revision 4 of Permit NEV HW0101 was issued effective December 10, 2015, and remains in effect until December 10, 2020.

54 ENVIRONMENTAL SCIENCES↗

Yakutat Tlingit Tribe Energy Conservation Upgrades & Energy Efficiency Measures

The Yakutat Tlingit Tribe (YTT) was awarded Strategic Technical Assistance Response Team (START) assistance from the Department of Energy (DOE) Office of Indian Energy Policy and Programs (OIEPP) in 2014. The intent of the grant was to lower energy consumption at both facilities (Kwaan Plaza which houses the medical clinic and the Community Center which housed the Tribe’s 477 Social Welfare Programs) and to explore technology to provide electricity and heat to the Kwaan Plaza.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stability and Conservation properties of Hermite-based approximations of the Vlasov-Poisson System

Spectral approximation based on Hermite-Fourier expansion of the Vlasov-Poisson model for a collisionless plasma in the electro-static limit is provided by adding high-order artificial collision operators of Lenard-Bernstein type. These differential operators are suitably designed in order to preserve the physically-meaningful invariants (number of particles, momentum, energy). In view of time-discretization, stability results in appropriate norms are presented. In this study, necessary conditions link the magnitude of the artificial collision term, the number of spectral modes of the discretization, as well as the time-step. The analysis, carried out in full for the Hermite discretization of a simple linear problem in one-dimension, is then partly extended to cover the complete nonlinear Vlasov-Poisson model.

97 MATHEMATICS AND COMPUTING↗

Non-Resource Conservation and Recovery Act Corrective Action Unit (CAU) Post-Closure Inspection Report, Nevada National Security Site, Nevada For Calendar Year 2022

This report includes visual inspection results, descriptions of maintenance and repair activities, and recommendations for calendar year (CY) 2022 for use restrictions (URs) at corrective action sites (CASs) located on the Nevada National Security Site (NNSS) and on the Nevada Test and Training Range (NTTR) that are accessed through the NNSS Main Gate. This document is formatted by project activity (i.e., Industrial Sites, Soils, and Defense Threat Reduction Agency [DTRA]); then by corrective action unit (CAU); and then by CAS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Non-Resource Conservation and Recovery Act Corrective Action Unit (CAU) Post-Closure Inspection Report, Nevada National Security Site, Nevada For Calendar Year 2024

This report includes visual inspection results, descriptions of maintenance and repair activities, and recommendations for calendar year 2024 for use restrictions at corrective action sites located on the Nevada National Security Site (NNSS) and on the Nevada Test and Training Range that are accessed through the NNSS Main Gate.

54 ENVIRONMENTAL SCIENCES↗

Non-Resource Conservation and Recovery Act Corrective Action Unit (CAU) Post-Closure Inspection Report, Nevada National Security Site, Nevada For Calendar Year 2025

This report includes visual inspection results, descriptions of maintenance and repair activities, and recommendations for CY 2025 for use restrictions (URs) at corrective action sites (CASs) located on the Nevada National Security Site and on the Nevada Test and Training Range (NTTR) that are accessed through the NNSS Main Gate. This document is arranged by project activity (i.e., Industrial Sites, Soils, and Defense Threat Reduction Agency [DTRA]); then by corrective action unit (CAU); and then by CAS. Post-closure UR inspections are performed on an annual basis, unless as noted in text. Post-closure UR inspections verify the condition of physical controls required by each UR, which may include the following activities: • Visual verification of the legibility of signs • Visual inspection of fencing, signs, monuments, and/or markers for indications of wear • Visual inspection of soil covers for indications of subsidence, erosion, or unauthorized use Deficiencies in UR requirements that were identified during CY 2024 inspections and not addressed in the CY 2024 report are addressed in this CY 2025 report.

54 ENVIRONMENTAL SCIENCES↗

Indiana Humanities Council Request for the Indianapolis Energy Conversion Inst. For Phase I of the Indianapolis Energy Conservation Res Initiative also called the smartDESKTOP Initiative

The smartDESKTOP Initiative at the Indiana Humanities Council received critical support in building and delivering a digital desktop for Indiana educators through the Department of Energy Grant DE-FG02-06ER64282. During the project period September 2006 through October of 2007, the number of Indiana educators with accounts on the smartDESKTOP more than tripled from under 2,000 to more than 7,000 accounts. An external review of the project conducted for the purposes of understanding the impact of the service in Indiana schools revealed that the majority of respondents felt that using the smartDESKTOP did reduce the time they spent managing paper. The same study revealed the challenges of implementing a digital desktop meant to help teachers leverage technology to improve their teaching and ultimately student learning. The most significant outcome of this project is that the Indiana Department of Education expressed interest in assuming responsibility for sustaining this project. The transition of the smartDESKTOP to the Indiana Department of Education was effective on November 1, 2007.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RenewableNY - An Industrial Energy Conservation Initiative

The New York Industrial Retention Network (NYIRN) manages the RenewableNY program to assist industrial companies in New York City to implement energy efficiency projects. RenewableNY provides companies with project management assistance and grants to identify opportunities for energy savings and implement energy efficiency projects. The program helps companies identify energy efficient projects, complete an energy audit, and connect with energy contractors who install renewable energy and energy efficient equipment. It also provides grants to help cover the costs of installation for new systems and equipment. RenewableNY demonstrates that a small grant program that also provides project management assistance can incentivize companies to implement energy efficiency projects that might otherwise be avoided. Estimated savings through RenewableNY include 324,500 kWh saved through efficiency installations, 158 kW of solar energy systems installed, and 945 thm of gas avoided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conservation laws in discrete geometry

The small length scales of the dissipative processes of physical viscosity and heat conduction are typically not resolved in the numerical simulation of high Reynolds number flows in the discrete geometry of computational grids. Historically, the simulations of flows with shocks and/or turbulence have relied on solving the Euler equations with dissipative regularization. In this paper, we begin by reviewing the regularization strategies used in shock wave calculations in both a Lagrangian and an Eulerian framework. We exhibit the essential similarities with Large Eddy Simulation models of turbulence, namely that almost all of these depend on the square of the size of the computational cell. In our principal result, we justify that dependence by deriving the evolution equations for a finite-sized volume of fluid. Those evolution equations, termed finite scale Navier-Stokes (FSNS), contain dissipative terms similar to the artificial viscosity first proposed by von Neumann and Richtmyer. Here, we describe the properties of FSNS, provide a physical interpretation of the dissipative terms and show the connection to recent concepts in fluid dynamics, including inviscid dissipation and bi-velocity hydrodynamics.

97 MATHEMATICS AND COMPUTING↗

Genetic approaches to the conservation of migratory bats: a study of the eastern red bat ( Lasiurus borealis )

Documented fatalities of bats at wind turbines have raised serious concerns about the future impacts of increased wind power development on populations of migratory bat species. However, for most bat species we have no knowledge of the size of populations and their demographic trends, the degree of structuring into discrete subpopulations, and whether different subpopulations use spatially segregated migratory routes. Here, we utilize genetic data from eastern red bats (Lasiurus borealis), one of the species most highly affected by wind power development in North America, to (1) evaluate patterns of population structure across the landscape, (2) estimate effective population size (N e ), and (3) assess signals of growth or decline in population size. Using data on both nuclear and mitochondrial DNA variation, we demonstrate that this species forms a single, panmictic population across their range with no evidence for the historical use of divergent migratory pathways by any portion of the population. Further, using coalescent estimates we estimate that the effective size of this population is in the hundreds of thousands to millions of individuals. The high levels of gene flow and connectivity across the population of eastern red bats indicate that monitoring and management of eastern red bats must integrate information across the range of this species.

Effective population size↗