Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPARATIVE EVALUATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Duluth Transit Authority Battery-Electric Bus Evaluation

Duluth Transit Authority (DTA) collaborated with the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) to evaluate a fleet of seven battery-electric buses (BEBs) in revenue service in Duluth, Minnesota. The focus of the evaluation was to compare performance and cost of the BEBs to that of conventional technology buses in similar service and track progress over time. DTA enlisted the help of the Center for Transportation and the Environment (CTE) to manage the project and provide technical services with the BEB fleet and infrastructure. This report summarizes the results of the BEB evaluation and contains a combination of analyses performed by NREL and by CTE during the overall data collection period of December 2018 through February 2022.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of the Fracture Toughness of Nb-40Al-8Cr-1W-1Y-0.05B Intermetallic Material by Indentation Techniques

The fracture toughness of an Nb-40Al-8Cr - 1W-1Y-0.05B intermetallic material was evaluated by indentation techniques at room temperature. Two widely used indentation methods, crack size measurement and indent strength, yielded excellent agreement with a conventional fracture toughness technique using straight-through precracked specimens, despite the occasional formation of poorly configured cracks. However, the modified indentation technique, using dummy indent flaws, resulted in a low fracture toughness compared to that evaluated by the other methods. The material did not exhibit rising R-curve behavior, as evaluated from the indentation strength data. These results indicate that indentation fracture principles are applicable to this brittle intermetallic material without modification of the residual contact stress term originally calibrated for ceramic materials.

Choi, S. R.↗

Trithiol ligand provides tumor-targeting 191 Pt-complexes with high molar activity and promising in vivo properties

The Auger electron-emitting radionuclide 191 Pt is a promising candidate for radiopharmaceutical therapy. Herein, we explored novel labeling methods for 191 Pt using thiol-containing ligands to improve the in vivo stability and targeting ability of 191 Pt-labeled complexes. We synthesized dithiol-containing N 2 S 2 and NS 2 ligands, and a trithiol ligand, and then compared their radiochemical reactivity with 191 Pt. [ 191 Pt]Pt-trithiol was synthesized and its biodistribution was evaluated in mice and compared with free 191 Pt. Finally, a 191 Pt-trithiol complex targeting prostate-specific membrane antigen (PSMA): [ 191 Pt]Pt-trithiol-PSMA was developed and evaluated in mice bearing tumor xenografts and compared with a 191 Pt-complex labeled via monothiol-containing Cys ([ 191 Pt]Pt-Cys-PSMA). A comparison of N 2 S 2 , NS 2 , and trithiol showed that the trithiol ligand is the best for producing 191 Pt-labeled compounds in high yield and as a single peak in preparative HPLC. Notably, the trithiol ligand made 191 Pt-labeled compounds and precursors separatable, achieving 191 Pt-labeled products with a high molar activity: 200–400 mCi/μmol (7.4–14.8 GBq/μmol) at EOS. Additionally, [ 191 Pt]Pt-trithiol and [ 191 Pt]Pt-trithiol-PSMA were stable in vivo with rapid clearance compared with free 191 Pt and [ 191 Pt]Pt-Cys-PSMA. [ 191 Pt]Pt-trithiol-PSMA resulted in a low uptake in most normal organs and a high uptake in the kidneys and prostate cancer with PSMA expression. Furthermore, this study demonstrated that a labeling method with trithiol for Pt radionuclides achieves 191 Pt-labeled products with high molar activity. 191 Pt-trithiol-PSMA showed promising in vivo stability and tumor-targeting specificity, which should facilitate the pharmaceutical development of Pt radionuclides for radiopharmaceutical therapy, especially Auger electron cancer therapy.

Auger emitters↗

Improved Oxygen Sources for Breathing Apparatus

Research is described which is directed toward the preparation of chemical oxygen sources which exhibited improved O2 storage and reaction characteristics when compared to potassium superoxide (KO2). The initial focus of the research was the preparation of calcium superoxide (Ca(O2)2) by the disproportionation of calcium peroxide diperoxyhydrate. the Ca(O2)2 was characterized by chemical, thermal, and x ray analyses. Several methods for scaling up the Ca(O2)2 syntheis process were studied. The reactivity of Ca(O2)2 toward humidified carbon dioxide (CO2) was evaluated and was compared to that of KO2 under flow test conditions approximating those existing in portable breathing apparatus. The reactivities of mixtures of KO2 and Ca(O2)2 or lithium peroxide towards humidified CO2 were also studied. Finally, an analysis of two commercial, KO2-based, self contained self rescuers was conducted to determine the potential weight and volume savings which would be possible if Ca(O2)2 or a mixture of KO2 and Ca(O2)2 were used as a replacement for KO2.

Wood, P. C.↗

An evaluation of strategic behaviors in a high fidelity simulated flight task - Comparing primary performance to a figure of merit

The usual method of evaluating flight performance during a simulation is to collect as many primary performance measurements as possible. Then analyze all the measurements to find one sensitive to the manipulations imposed on the pilot during the scenario. Although this method can be useful, it is usually unreliable from one study to another. A simulation was conducted to test an integrated figure of merit (FOM) constructed using a standardized procedure. Pilots flew two full-mission scenarios in an instrument trainer with three degrees of motion freedom. The primary performance measurements selected assessed the pilot's performance in accuracy, smoothness, and activity. The results suggest that the integrated FOMs performed comparably to the primary performance measurements in determining which flight imposed the higher demands on the pilot. The standardized construction process allow adjustments to the FOM, so it can be used in different applications.

Bortolussi, Michael R.↗

Forecast skill impact of drifting buoys in the Southern Hemisphere

Two analyses are performed to evaluate the effect of drift buoys and the FGGE's special observing system (SOS) on forecasting. The FGGE analysis utilizes all level II-b conventional and special data, and the Nosat analysis employs only surface and conventional upper air data. Twelve five-day forecasts are produced from these data. An additional experiment utilizing the FGGE data base minus buoys data, and the Nosat data base including buoys data is being conducted. The forecasts are compared and synoptic evaluation of the effect of buoys data is described. The results reveal that the FGGE data base with the SOS significantly improves forecasting in the Southern Hemisphere and the loss of buoys data does not have a great effect on forecasting. The Nosat data has less impact on forecasting; however, the addition of buoys data provides an improvement in forecast skills.

Kalnay, E.↗

A comparative study of SAR data compression schemes

The amount of data collected from spaceborne remote sensing has substantially increased in the last years. During same time period, the ability to store or transmit data has not increased as quickly. At this time, there is a growing interest in developing compression schemes that could provide both higher compression ratios and lower encoding/decoding errors. In the case of the spaceborne Synthetic Aperture Radar (SAR) earth observation system developed by the French Space Agency (CNES), the volume of data to be processed will exceed both the on-board storage capacities and the telecommunication link. The objective of this paper is twofold: to present various compression schemes adapted to SAR data; and to define a set of evaluation criteria and compare the algorithms on SAR data. In this paper, we review two classical methods of SAR data compression and propose novel approaches based on Fourier Transforms and spectrum coding.

Lambert-Nebout, C.↗

A Scalable Reduced‐Order Model for the Steady Navier–Stokes Equations

Scaling up new scientific technologies from laboratory to industry often involves demonstrating performance on a larger scale. Computer simulations can accelerate design and predictions in the deployment process, though traditional numerical methods are computationally intractable even for intermediate pilot plant scales. Recently, the component reduced order modeling method has been developed to tackle this challenge by combining projection reduced order modeling and discontinuous Galerkin domain decomposition. However, while many scientific or engineering applications involve nonlinear physics, this method has only been demonstrated for various linear systems. In this work, the component reduced order modeling method is extended to steady Navier–Stokes flow, with application to general nonlinear physics in view. The large‐scale, global domain is decomposed into a combination of small‐scale unit component. Linear subspaces for flow velocity and pressure are identified via proper orthogonal decomposition over sample snapshots collected from each small‐scale unit component. Velocity bases are augmented with a pressure supremizer to satisfy the inf–sup condition for stable pressure prediction. Two different nonlinear reduced order modeling methods are employed and compared for efficient evaluation of nonlinear advection: A third‐order tensor projection operator and the empirical quadrature procedure. The proposed method is demonstrated on the flow over arrays of five different unit objects, achieving a 23‐fold speedup with less than 4% relative error in domains up to 256 times larger than the unit components. Furthermore, a numerical experiment with the pressure supremizer strongly indicates the need for a supremizer for stable pressure prediction. A comparison between the tensorial approach and the empirical quadrature procedure revealed a slight advantage of the empirical quadrature procedure. The framework is compared with an alternating Schwarz‐based reduced‐order approach, demonstrating improved efficiency and robustness for the DG‐based global solver while retaining flexibility for sub‐scale iterative solvers. The method is further extended to a coupled advection–diffusion and Navier–Stokes system, illustrating its applicability to multi‐physics problems and its potential for more general, inter‐coupled nonlinear systems.

42 ENGINEERING↗

Standard Test Methods for Textile Composites

Standard testing methods for composite laminates reinforced with continuous networks of braided, woven, or stitched fibers have been evaluated. The microstructure of these textile' composite materials differs significantly from that of tape laminates. Consequently, specimen dimensions and loading methods developed for tape type composites may not be applicable to textile composites. To this end, a series of evaluations were made comparing testing practices currently used in the composite industry. Information was gathered from a variety of sources and analyzed to establish a series of recommended test methods for textile composites. The current practices established for laminated composite materials by ASTM and the MIL-HDBK-17 Committee were considered. This document provides recommended test methods for determining both in-plane and out-of-plane properties. Specifically, test methods are suggested for: unnotched tension and compression; open and filled hole tension; open hole compression; bolt bearing; and interlaminar tension. A detailed description of the material architectures evaluated is also provided, as is a recommended instrumentation practice.

Masters, John E.↗

A transcriptome software comparison for the analyses of treatments expected to give subtle gene expression responses

Background: In this comparative study we evaluate the performance of four software tools: DNAstar-D (DESeq2), DNAstar-E (edgeR), CLC Genomics and Partek Flow for identification of differentially expressed genes (DEGs) using a transcriptome of E. coli. The RNA-seq data are from the effect of below-background radiation 5.5 nGy total dose (0.2nGy/hr) on E. coli grown shielded from natural radiation 655 m below ground in a pre-World War II steel vault. The gene expression response to three supplemented sources of radiation designed to mimic natural background, 1952 – 5720 nGy in total dose (71–208 nGy/hr), are compared to this “radiation-deprived” treatment. In addition, RNA-seq data of Caenorhabditis elegans nematode from similar radiation treatments was analyzed by three of the software packages. Results: In E. coli, the four software programs identified one of the supplementary sources of radiation (KCl) to evoke about 5 times more transcribed genes than the minus-radiation treatment (69–114 differentially expressed genes, DEGs), and so the rest of the analyses used this KCl vs “Minus” comparison. After imposing a 30-read minimum cutoff, one of the DNAStar options shared two of the three steps (mapping, normalization, and statistic) with Partek Flow (they both used median of ratios to normalize and the DESeq2 statistical package), and these two programs identified the highest number of DEGs in common with each other (53). In contrast, when the programs used different approaches in each of the three steps, between 31 and 40 DEGs were found in common. Regarding the extent of expression differences, three of the four programs gave high fold-change results (15–178 fold), but one (DNAstar’s DESeq2) resulted in more conservative fold-changes (1.5–3.5). In a parallel study comparing three qPCR commercial validation software programs, these programs also gave variable results as to which genes were significantly regulated. Similarly, the C. elegans analysis showed exaggerated fold-changes in CLC and DNAstar’s edgeR while DNAstar-D was more conservative. Conclusions: Regarding the extent of expression (fold-change), and considering the subtlety of the very low level radiation treatments, in E. coli three of the four programs gave what we consider exaggerated fold-change results (15 – 178 fold), but one (DNAstar’s DESeq2) gave more realistic fold-changes (1.5–3.5). When RT-qPCR validation comparisons to transcriptome results were carried out, they supported the more conservative DNAstar-D’s expression results. When another model organism’s (nematode) response to these radiation differences was similarly analyzed, DNAstar-D also resulted in the most conservative expression patterns. Therefore, we would propose DESeq2 (“DNAstar-D”) as an appropriate software tool for differential gene expression studies for treatments expected to give subtle transcriptome responses.

59 BASIC BIOLOGICAL SCIENCES↗

Los Angeles International Airport Runway Incursion Studies: Phase III--Center-Taxiway Simulation

Phase III of the Los Angeles International Airport Runway Incursion Studies was conducted, under an agreement with HNTB Corporation, at the NASA Ames FutureFlight Central (FFC) facility in June 2003. The objective of the study was the evaluation of a new center-taxiway concept at LAX. This study is an extension of the Phase I and Phase II studies previously conducted at FFC. This report presents results from Phase III of the study, in which a center-taxiway concept between runways 25L and 25R was simulated and evaluated. Phase III data were compared objectively against the Baseline data. Subjective evaluations by participating LAX controllers were obtained with regard to workload, efficiency, and safety criteria. To facilitate a valid comparison between Baseline and Phase III data, the same scenarios were used for Phase III that were tested during Phases I and II. This required briefing participating controllers on differences in airport and airline operations between 2001 and today.

Madson, Michael D.↗

Upcycling of post-consumer mixed polyolefin feedstock: An economic and technical evaluation

Here, this study reports techno-economic and life cycle analyses to evaluate the economic and environmental impacts of mechanically recycled PE/PP blends in the presence of rheology modifiers. Additionally, fiber-reinforced composites derived from the compatibilized blends were prepared and evaluated for their performance compared with virgin plastics. Results suggest that compatibilized PE/PP blends exhibit a 70% lower selling price compared to virgin PE. Furthermore, these blends achieved a 74% reduction in greenhouse gas emissions or climate change impact compared to the virgin counterpart. Fiber-reinforced composites from compatibilized PE/PP blends demonstrated improved or comparable mechanical properties relative to composites made from virgin PE/PP blends. Based on their favorable cost and environmental impact, along with performance comparable to virgin composites, compatibilized PP/PE composites made from post-consumer plastics can find applications in large-scale composite manufacturing.

Fiber reinforced plastics (FRP)↗

Evaluation of simulated HPGe detector efficiencies in OpenMC compared to MCNP

In late 2023, the open-source radiation transport code OpenMC introduced a pulse-height tally (PHT) feature, enabling users to track the total energy deposited by individual photons in OpenMC cells. This function represents an important improvement of the OpenMC code because it allows users to simulate the response function of a gamma detector without relying on closed-source alternatives. Despite this, limited work has been published evaluating OpenMC as a radiation transport code for simulating gamma spectroscopy experiments. This study attempts to demonstrate the usefulness of OpenMC in this space by directly comparing its PHT output to MCNP (a trusted industry-standard Monte Carlo code). In the first half of this study, a radiation transport experiment is described in which a detector with a complex internal geometry is exposed to various gamma-emitting isotopes ( 133 Ba, 137 Cs, and 60 Co) over a range of distances. The setup of this experiment was modeled in MCNP with sufficient detail to capture the efficiency characteristics of a high purity germanium (HPGe) detector for the primary gammas of each isotope. After good agreement between the MCNP model and experiment was achieved, an identical model was produced in OpenMC to allow direct comparison between the full energy peak (FEP) values produced in OpenMC and MCNP. The results show strong agreement between OpenMC and MCNP across the full range of tested energies, with each model’s FEP values typically within 2% of each other and most FEP areas within 4% of experimental data. Worse agreement was seen between the Monte Carlo codes and experiment below 300 keV (an expected result). For the 662 keV line of 137 Cs, both codes were found in poor agreement with experiment and each other over the full range of distances tested (possibly indicating an error with the 137 Cs experimental data). Ignoring the anomalous results of the 662 keV line, all other data show good qualitative and quantitative agreement between MCNP and OpenMC. This result demonstrates the accuracy of OpenMC’s PHT feature for spectroscopic applications in which detector efficiency is a primary concern.

07 - ISOTOPES AND RADIATION SOURCES↗

Model for Predicting the Performance of Planetary Suit Hip Bearing Designs

Designing a space suit is very complex and often requires difficult trade-offs between performance, cost, mass, and system complexity. During the development period of the suit numerous design iterations need to occur before the hardware meets human performance requirements. Using computer models early in the design phase of hardware development is advantageous, by allowing virtual prototyping to take place. A virtual design environment allows designers to think creatively, exhaust design possibilities, and study design impacts on suit and human performance. A model of the rigid components of the Mark III Technology Demonstrator Suit (planetary-type space suit) and a human manikin were created and tested in a virtual environment. The performance of the Mark III hip bearing model was first developed and evaluated virtually by comparing the differences in mobility performance between the nominal bearing configurations and modified bearing configurations. Suited human performance was then simulated with the model and compared to actual suited human performance data using the same bearing configurations. The Mark III hip bearing model was able to visually represent complex bearing rotations and the theoretical volumetric ranges of motion in three dimensions. The model was also able to predict suited human hip flexion and abduction maximums to within 10% of the actual suited human subject data, except for one modified bearing condition in hip flexion which was off by 24%. Differences between the model predictions and the human subject performance data were attributed to the lack of joint moment limits in the model, human subject fitting issues, and the limited suit experience of some of the subjects. The results demonstrate that modeling space suit rigid segments is a feasible design tool for evaluating and optimizing suited human performance. Keywords: space suit, design, modeling, performance

Cowley, Matthew S.↗

Comparative critical mass calculations for NNL and ENDF/B-VIII.0 - Zirconium hydride thermal neutron scattering laws

Zirconium hydride (ZrH{sub x}) is a moderator material for TRIGA reactors and historical space reactor systems, such as SNAP-10A. Thermal neutron scattering laws (TSL) for two phases of this material, δ and ε, have been previously evaluated by Naval Nuclear Laboratory (NNL) and submitted to the National Nuclear Data Center (NNDC) for inclusion in the US national ENDF/B-VIII.1 nuclear data library. In contrast to the current ENDF/B-VIII.0 TSL evaluations, which consider only a single phase, the new evaluations are derived from separate ab initio calculations for both phases and include coherent elastic effects of the zirconium sublattice. To estimate the impact of these changes to the TSL evaluation of this material, comparative critical mass calculations were performed with MC21 for homogenous mixtures of high-enriched uranium (HEU) and ZrH{sub x} in bare and water reflected sphere configurations. These calculations yield an impact on the estimated critical mass as a function of {sup 235}U loading density with maximum differences as large as 1% - 5% for over-moderated thermal spectrum systems. Consequently, the NNL TSL evaluations are anticipated to have a small impact on criticality calculations of thermal reactor systems regardless of the material phase. Nevertheless, characteristic differences exist in the predicted thermal spectra as function of energy for the two sets of TSL evaluations, which are attributed to difference in the underlying phonon density of states of hydrogen bound in ZrH{sub x}. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗

Measurement of ( n, γ ) cross section of 90 Zr [Abstract]

The isotopes of Zr with A = [90, 91, 92, 94] make up more than 97% of naturally occurring Zr and are important to many nuclear applications such as nuclear reactors. One of the attractive qualities of naturally occurring Zr isotopes is that they have a low σγ/σt ratio at most neutron energies, such that they improve the neutron economy in reactors by preferentially scattering neutrons rather than absorbing them. This same quality also presents a challenge to measuring the capture cross section, σγ, of Zr isotopes. The ENDF/B-VIII.0 library has a relative uncertainty of approximately 10-20% for incident neutron energies < 0.1 MeV, and uncertainty greater than 20% for energies > 0.1 MeV for the majority of natural Zr isotopes. This motivated the Nuclear Criticality Safety Program (NCSP) to embark on a campaign to accurately measure and evaluate these isotopes of Zr. Here we will show energy-dependent neutron capture cross section measurements for the first enriched sample to be measured: 90 Zr. The measurements of isotopically enriched samples are being carried out at the Geel Electron Linear Accelerator (GELINA) facility of the Joint Research Center - Geel (JRC-Geel) of the European Union. As isotopic enrichment is a costly process we are careful not to activate any of the samples, as this may hinder future radiation-sensitive measurements. The activation analysis is presented in a report by Brown et al.. Once we were satisfied that the Zr samples would not be activated by the measurements, the 90 Zr sample was fabricated at Oak Ridge National Laboratory (ORNL) and shipped to GELINA. The dimensions of the cylindrical sample are approximately 0.12 cm thick and a radius of 2.5 cm. Since 90 Zr is not chemically reactive to air, bare metallic samples were employed. The sample was measured at a flight path (FP) length of 60 m, using four C 6 D 6 detectors on FP14. The final paper will include experimental details and measured cross section data for 90 Zr compared to current evaluated nuclear data libraries.

07 ISOTOPE AND RADIATION SOURCES↗

Gas Stopper Developments for Improved Purity and Intensity of Low-Energy, Rare Isotope Ion Beams (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0021423 awarded by the Office of Nuclear Physics, Department of Energy. Objectives: The successful fulfillment of the FRIB science mission hinges on ensuring the availability of fast, stopped, and reaccelerated beams consisting of rare isotopes. This project's research and development focus was dedicated to supporting the advancement and creation of a cutting-edge linear gas stopper. The primary aim is to efficiently convert the high-intensity fast beams of rare isotopes provided by FRIB into high-quality, low-energy beams. These beams are essential for conducting stopped beam experiments or for subsequent reacceleration. The overarching goal is to advance technology, aiming to increase the beam rate capability of the linear gas stopper for medium-to-heavy-mass rare isotopes by more than tenfold compared to the currently most effective gas stopper in operation, and to improve the purity of the delivered beams. Project Description: The existing technology employed in gas stopping devices designed for low-energy, rare-isotope beams presents limitations in both the purity of extracted beams and the intensities of injected beams. These limitations are incompatible with the requirements of the recently commissioned rare isotope beam facility, FRIB. Our research and development efforts, aligned with the previously outlined objectives, focused on addressing the most critical aspects for enhancing beam-rate capability and purity. Specifically, advanced particle-in-cell simulations were developed and integrated into a simulation pipeline to explore the efficacy of multi-layer RF carpets on increasing ion transport efficiency with high incoming beam rates that generate space charge fields which can limit it. We also explored the possibility of using a collision-induced-dissociation (CID) gas cell to break up molecular contaminant ions that are generated during the stopping process. A prototype CID gas cell was constructed and tested with beams from an offline ion source, validating the concept with the successful demonstration of breaking of molecular ions. The outcome of this research enabled the formulation a conceptual design for a next-generation linear gas stopping device specifically tailored for FRIB. This device is envisioned to deliver rare-isotope-ion beams at a rate of 10 8 particles per second or higher, accompanied by advancements in purity. Methods employed: This project leverages advancements in technologies initially designed for the Advanced Cryogenic Gas Stopper (ACGS), the current state-of-the-art linear gas stopper, through the use of new simulations and beam purification via collision-induced-dissociation. The methods include: 1. Development of a prototype low-energy, low-pressure CID gas stopper. This prototype features a thin, approximately 20 nm, Si 3 N 4 entrance window designed for dissociating stable and rare-isotope molecular ions. The goal is to enhance beam purification and overall efficiency. 2. Creation of Particle-in-cell (PIC) simulations to assess the advantages of multi-layer RF carpets and multi-point extraction for ion transport efficiency. These simulations rely on the 3DCylPIC package, specifically designed for studying devices of this nature. The goal is to quantify and mitigate ion transport losses due to space charge generated in the stopping process of large numbers of ions. 3. Perform ion transport simulations across an RF carpet using an 8-phase travelling wave and evaluate its performance. Compared to the 4-phase RF carpets used in ACGS, the 8-phase carpets will double the wavelength of the generated traveling wave allowing for larger maximum RF amplitudes that could result in improved ion transport efficiency for high-intensity incoming beams when large space charge fields are present. Impact: Tackling the primary challenges associated with transforming high-energy projectile fragment beams into low-energy beams—specifically, addressing efficiency and purity—holds significant promise for advancing FRIB science. This advancement will particularly impact precision mass measurements, laser spectroscopy of short-lived nuclei, and studies in astrophysics and nuclear reactions using reaccelerated beams. These domains play a crucial role in addressing key questions outlined in the 2023 NSAC long-range plan, spanning nuclear structure, nuclear astrophysics, and fundamental symmetries. Additionally, they contribute to addressing 10 out of the 17 benchmarks identified by the NRC RISAC. The development of a next-generation gas stopping device capable of delivering low-energy, rare-isotope beams at a rate of 10 8 particles per second, or more, with high purity holds the potential to unlock experiments that would otherwise be unfeasible. Furthermore, it is expected to reduce the time required for experiments at FRIB, thereby maximizing scientific output. The research and development activities performed as part of this project bolstered essential competencies at FRIB in beam physics and ion source technologies, provided valuable training opportunities for junior scientists.

43 PARTICLE ACCELERATORS↗