Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Building Energy Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cellular Shade Energy Savings in a Commercial Setting

Windows cause approximately 1.7 quad of heating and cooling energy consumption in the United States. This energy consumption can be reduced by using high-efficiency window attachments. Common Venetian blinds and planar shades, such as roller shades, might block solar radiation, but they do not provide a significant improvement to window system thermal transmittance. Cellular shades have better thermal performance compared to other shading devices because of the honeycomb structure that traps air in pockets to create thermal insulation. However, evaluating the energy savings potential of cellular shades using experimental testing in commercial settings is limited. Moreover, the effect of cellular shades on daylighting and glare is yet to be evaluated using field testing. In this study, experimental testing of cellular shades was performed in a real building with emulated occupancy for both a cooling and a heating season. Compared with a room without shades, the use of cellular shades in experimental testing showed incremental energy savings of 4.6% to 9.4% for cooling and higher than 20% for heating. The experimental data were used to calibrate the baseline energy model and validate the cellular shades model. Annual simulation of cellular shades was performed for a medium office prototype building using the validated cellular shades model. The annual simulation was performed in Phoenix, Nashville, and Rochester. The annual savings for HVAC energy was 25% for Phoenix, 27% for Nashville, and 19% for Rochester.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Propane Furnace 95% AFUE and Fuel Oil Furnace 88% AFUE

This report is part of a series describing different ResStock (TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Propane Fuel 95% AFUE and Fuel Oil Furnace 88% AFUE" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A framework for estimating the energy-saving potential of occupant behaviour improvement

Energy-related occupant behaviour in buildings has demonstrated considerable energy-saving potential. However, the current modelling method of occupant behaviour does not give sufficient considerations on the implementation difficulty of behaviour and provide a holistic map from survey data to various behaviour models. This article proposes a holistic survey-and-simulation-based framework for estimating the energy-saving potential of occupant behaviour improvement. In the framework, seven typical categories of occupant behaviour models are identified based on the survey results. According to the implementation difficulty, the models are integrated into four behaviour styles (baseline, wasteful, moderate and austere) to represent different levels of energy-saving consciousness of occupants. Based on a case study with a nationwide survey in Singapore, there are remarkable energy savings potential if occupant behaviour is improved; the building energy consumption can be reduced by up to 9.5% with the moderate behaviour improvement, and up to 21.0% with the aggressive behaviour improvement. The simulation results accord well with the measured results within a reasonable range of deviation. The framework can be applied to estimate the energy-saving potential of occupant behaviour improvement in a building with affordable cost, and the findings can inform a behaviour improvement programme with effective and efficient measures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

COMSOL Multiphysics Model for HLW Canister Filling

The U.S. Department of Energy (DOE) is building a Tank Waste Treatment and Immobilization Plant (WTP) at the Hanford Site in Washington to remediate 55 million gallons of radioactive waste that is being temporarily stored in 177 underground tanks. Efforts are being made to increase the loading of Hanford tank wastes in glass while meeting melter lifetime expectancies and process, regulatory, and product quality requirements. Wastes containing high concentrations of Al 2 O 3 and Na 2 O can contribute to nepheline (generally NaAlSiO 4 ) crystallization, which can sharply reduce the chemical durability of high level waste (HLW) glass. Nepheline crystallization can occur during slow cooling of the glass within the stainless steel canister. The purpose of this work was to develop a model that can be used to predict temperatures of the glass in a WTP HLW canister during filling and cooling. The intent of the model is to support scoping work in the laboratory. It is not intended to provide precise predictions of temperature profiles, but rather to provide a simplified representation of glass cooling profiles within a full scale, WTP HLW canister under various glass pouring rates. These data will be used to support laboratory studies for an improved understanding of the mechanisms of nepheline crystallization. The model was created using COMSOL Multiphysics, a commercially available software. The model results were compared to available experimental data, TRR-PLT-080, and were found to yield sufficient results for the scoping nature of the study. The simulated temperatures were within 60 ºC for the centerline, 0.0762m (3 inch) from centerline, and 0.2286m (9 inch) from centerline thermocouples once the thermocouples were covered with glass. The temperature difference between the experimental and simulated values reduced to 40 ºC, 4 hours after the thermocouple was covered, and down to 20 ºC, 6 hours after the thermocouple was covered. This level of precision is considered acceptable for the scoping nature of the model and the subsequent laboratory glass studies Using the model, two additional glass pouring cycles were conducted. Representative thermocouple data were plotted to show the variations between the two cycles. This provides preliminary data that will be used in laboratory experiments to determine the potential for controlling nepheline crystallization in glass by varying the glass pouring conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimizing Distributed Energy Resources and building retrofits with the strategic DER-CAModel

The pressuring need to reduce the import of fossil fuels as well as the need to dramatically reduce CO 2 emissions in Europe motivated the European Commission (EC) to implement several regulations directed to building owners. Most of these regulations focus on increasing the number of energy efficient buildings, both new and retrofitted, since retrofits play an important role in energy efficiency. Overall, this initiative results from the realization that buildings will have a significant impact in fulfilling the 20/20/20-goals of reducing the greenhouse gas emissions by 20%, increasing energy efficiency by 20%, and increasing the share of renewables to 20%, all by 2020. The Distributed Energy Resources Customer Adoption Model (DER-CAM) is an optimization tool used to support DER investment decisions, typically by minimizing total annual costs or CO 2 emissions while providing energy services to a given building or microgrid site. This document shows enhancements made to DER-CAM to consider building retrofit measures along with DER investment options. Specifically, building shell improvement options have been added to DER-CAM as alternative or complementary options to investments in other DER such as PV, solar thermal, combined heat and power, or energy storage. The extension of the mathematical formulation required by the new features introduced in DER-CAM is presented and the resulting model is demonstrated at an Austrian Campus building by comparing DER-CAM results with and without building shell improvement options. Strategic investment results are presented and compared to the observed investment decision at the test site. Results obtained considering building shell improvement options suggest an optimal weighted average U value of about 0.53 W/(m 2 K) for the test site. This result is approximately 25% higher than what is currently observed in the building, suggesting that the retrofits made in 2002 were not optimal. Furthermore, the results obtained with DER-CAM illustrate the complexity of interactions between DER and passive measure options, showcasing the need for a holistic optimization approach to effectively optimize energy costs and CO 2 emissions. Lastly, the simultaneous optimization of building shell improvements and DER investments enables building owners to take one step further towards nearly zero energy buildings (nZEB) or nearly zero carbon emission buildings (nZCEB), and therefore support the 20/20/20 goals.

25 ENERGY STORAGE↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Sizing and Modeling Platform for District Energy Systems with Geothermal Heat Pumps

Existing tools for community or urban scale energy system modeling and simulation are often limited in their capabilities and require expert-level modeling proficiency to develop system models. To fill this gap, this paper proposes an integrated sizing and modeling platform for district energy systems with geothermal heat pumps. The proposed platform takes in geometric and non-geometric user inputs related to the buildings, borefield, and district energy loop. Then, the platform sizes the geothermal heat exchanger, generates a corresponding district energy system model, and runs an annual simulation automatically. We validated the simulation performance of the borefield in our tool against EnergyPlus. A case study is provided in this paper to demonstrate the workflow and simulation result plausibility of the proposed platform.

decarbonization↗

Comparative Study and Validation of Photovoltaic Model Formulations for the IBPSA Modelica Library based on Rooftop Measurement Data

Domain-overarching system models are crucial to investigate sector coupling concepts. Specifically, the coupling of building and electrical energy systems becomes crucial to integrate renewable energy sources such as photovoltaic power systems (PV). For such interdisciplinary simulation models, Modelica is a suitable language. However, most open-source Modelica libraries are either domain-specific or lack simple-to-parameterize PV models. We close this gap by developing a PV model for the IBPSA Modelica library. The model comprises two I-V-characteristic models and three mounting-dependent approaches to calculate the cell temperature. The I-V-characteristic models follow a single- and two-diodes approach. This study uses measurement data from a rooftop PV system in Berlin, Germany, for validation. The focus lies on comparing the implemented single- and two-diodes approach. Results prove that both models accurately calculate the modules’ DC power output and cell temperature. The two-diodes approach slightly outperforms the single-diode one at the expense of a higher parameterization effort.

Maier, Laura↗

Encouraging Combined Heat and Power in California Buildings

Governor Brown’s research priorities include an additional 6.5 GW of combined heat and power (CHP) by 2030. As of 2009, roughly 0.25 GW of small natural gas and biogas fired CHP is documented by the Self-Generation Incentive Program (SGIP) database. The SGIP is set to expire, and the anticipated grid de-carbonization based on the development of 20 GW of renewable energy will influence the CHP adoption. Thus, an integrated optimization approach for this analysis was chosen that allows optimizing the adoption of distributed energy resources (DER) such as photovoltaics (PV), CHP, storage technologies, etc. in the California commercial sector from the building owners’ perspective. To solve this DER adoption problem the Distributed Energy Resources Customer Adoption Model (DER-CAM), developed by the Lawrence Berkeley National Laboratory and used extensively to address the problem of optimally investing and scheduling DER under multiple settings, has been used. The application of CHP at large industrial sites is well known, and much of its potential is already being realized. Conversely, commercial sector CHP, especially those above 50 to 100 kW peak electricity load, is widely overlooked. In order to analyze the role of DER in CO 2 reduction, 147 representative sites in different climate zones were selected from the California Commercial End Use Survey (CEUS). About 8000 individual optimization runs, with different assumptions for the electric tariffs, natural gas costs, marginal grid CO 2 emissions, and nitrogen oxide treatment costs, SGIP, fuel cell lifetime, fuel cell efficiency, PV installation costs, and payback periods for investments have been performed. The most optimistic CHP potential contribution in this sector in 2020 will be 2.7 GW. However, this result requires a SGIP in 2020, 46% average electric efficiency for fuel cells, a payback period for investments of 10 years, and a CO 2 focused approach of the building owners. In 2030 it will be only 2.5 GW due to the anticipated grid decarbonization. The 2030 result requires a 60% electric efficiency and 20 year life time for fuel cells, a payback period of 10 years, and a CO 2 minimization strategy of building owners. Finally, the possible CHP potential in 2030 shows a significant variance between 0.2 GW and 2.5 GW, demonstrating the complex interactions between technologies, policies, and customer objectives.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

Traditionally, analytical frameworks that underpin building energy policy have focused on the need to reduce annual energy consumption by assessing the cost and efficiency performance of energy-consuming technologies. Investments in distributed energy resources (DERs) such as photovoltaics have generally been evaluated independently, but also on a cost and performance basis. However, buildings are rapidly evolving to incorporate technologies that not just consume energy, but also generate, store, and control energy loads. Concurrently, the electric grid is becoming more dynamic and variable due to the increased proportion electricity production from variable renewable sources. To that end, building energy policy analytical frameworks should be updated to include the interactions between energy efficiency and DERs as well as potential value streams for the grid and building owner that technologies or packages of technologies might offer. As buildings with DERs and controllable loads are able to provide grid services or optimize operations based on electricity rates and grid conditions, the temporal and spatial nature of these technologies should also be incorporated into design decisions. To explore these questions further, the National Renewable Energy Laboratory will use a series of building and electric grid models to simulate the design and operation of a neighborhood of buildings under various electricity rates, grid conditions, and potential compensation scenarios. Scenarios of time-sensitive values for future grid services will also be constructed for use in the analysis. New metrics that can be used in building energy policies will also be explored to capture the responsiveness or flexibility of high efficiency buildings with DERs under various electric grid conditions and future scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment

Traditionally, analytical frameworks that underpin building energy policy have focused on the need to reduce annual energy consumption by assessing the cost and efficiency performance of energy-consuming technologies. Investments in distributed energy resources (DERs) such as photovoltaics have generally been evaluated independently, but also on a cost and performance basis. However, buildings are rapidly evolving to incorporate technologies that not just consume energy, but also generate, store, and control energy loads. Concurrently, the electric grid is becoming more dynamic and variable due to the increased proportion electricity production from variable renewable sources. To that end, building energy policy analytical frameworks should be updated to include the interactions between energy efficiency and DERs as well as potential value streams for the grid and building owner that technologies or packages of technologies might offer. As buildings with DERs and controllable loads are able to provide grid services or optimize operations based on electricity rates and grid conditions, the temporal and spatial nature of these technologies should also be incorporated into design decisions. To explore these questions further, the National Renewable Energy Laboratory will use a series of building and electric grid models to simulate the design and operation of a neighborhood of buildings under various electricity rates, grid conditions, and potential compensation scenarios. Scenarios of time-sensitive values for future grid services will also be constructed for use in the analysis. New metrics that can be used in building energy policies will also be explored to capture the responsiveness or flexibility of high efficiency buildings with DERs under various electric grid conditions and future scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of MPC Formulations for Building Control under Commercial Time-of-Use Tariffs

© 2019 IEEE. Most medium and large commercial buildings in the U.S. are subject to complex electricity tariffs that combine both Time-of-Use (TOU) energy and demand charges. This study analyses the performances of different economic Model Predictive Control (MPC) formulations, from the standpoints of monthly bill reduction, load shifting, and peak demand reduction. Simulations are performed on many simplified commercial building models, with multiple TOU demand charges, and under various summer conditions. Results show that compared to energy-only MPC, the traditional method for dealing with demand charges significantly reduces peak demand and owner bill, however, highlight a lack of load shifting capability. A proposed incremental approach is presented, which better balances the bill components in the objective function. In the case study presented, this method can improve monthly bill savings and increase load shifting during demand response events, while keeping a similarly low peak demand, compared to traditional MPC methods taking into account demand charges.

Cutsem, Olivier Van↗

A Comparison of Simulation Capabilities for Ducts

Typically, the cheapest way to install a central air conditioning system in residential buildings is to place the ductwork in the attic. Energy losses due to duct-attic interactions can be great, but current whole-house models are unable to capture the dynamic multi-mode physics of the interactions. The building industry is notoriously fragmented and unable to devote adequate research resources to solve this problem. Builders are going to continue to put ducts in the attic because floor space is too expensive to closet them within living space, and there are both construction and aesthetic issues with other approaches such as dropped ceilings. Thus, there is a substantial need to publicly document duct losses and the cost of energy used by ducts in attics so that practitioners, builders, homeowners and state and federal code officials can make informed decisions leading to changes in new construction and additional retrofit actions. Thus, the goal of this study is to conduct a comparison of AtticSim and EnergyPlus simulation algorithms to identify specific features for potential inclusion in EnergyPlus that would allow higher-fidelity modeling of HVAC operation and duct transport of conditioned air. It is anticipated that the resulting analysis from these simulation tools will inform energy decisions relating to the role of ducts in future building energy codes and standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Results from Development of Model Specifications for Multifamily Energy Retrofits

Specifications, modeled after CSI MasterFormat, provide the trade contractors and builders with requirements and recommendations on specific building materials, components and industry practices that comply with the expectations and intent of the requirements within the various funding programs associated with a project. The goal is to create a greater level of consistency in execution of energyefficiency retrofits measures across the multiple regions a developer may work. IBACOS and Mercy Housing developed sample model specifications based on a common building construction type that Mercy Housing encounters.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultimate Strength of Metals

We present a theoretical model that predicts the peak strength of polycrystalline metals based on the activation energy (or stress) required to cause deformation via amorphization. Building on extensive earlier work, this model is based purely on materials properties, requires no adjustable parameters, and is shown to accurately predict the strength of four exemplar metals (fcc, bcc, and hcp, and an alloy). This framework reveals new routes for design of more complex high-strength materials systems, such as compositionally complex alloys, multiphase systems, nonmetals, and composite structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrating Energy-Efficient Computing with Computational Research to Accelerate Energy Technology

NREL's computational sciences center hosts the largest high performance computing (HPC) capabilities dedicated to energy research while functioning as a living laboratory for energy-efficient computing. NREL's HPC capabilities support the research needs of the Department of Energy's Office of Energy Efficiency and Renewable Energy (EERE). In ten years of operation, HPC use in EERE-sponsored research has grown by a factor of 30, including work in electricity generation, energy efficiency, transportation, and energy system modeling. This paper analyzes this research portfolio, providing examples of individual use cases. The paper documents NREL's history of operating one of the world's most energy-efficient data centers while examining pathways to reduce economic and environmental impact beyond reduction of Power Usage Efficiency (PUE). This paper concludes by examining the unique opportunities created for accelerating improvements in data center efficiency created by combining an HPC system dedicated to energy research and a research program in energy-efficient computing.

97 MATHEMATICS AND COMPUTING↗

Energy Model to Evaluate Thermal Energy Storage Integrated with Air Source Heat Pumps: Preprint

Full decarbonization in buildings requires the replacement of combustion appliances with electric ones, and air source heat pumps (ASHP) are a candidate alternative. However, technical limitations, such as the efficiency decrease when operating in cold weather, limit their adoption in the global heating market. Among several options to improve ASHP efficiency operating in colder climates, thermal energy storage (TES) has been considered, as it may provide heating when it is cold and shift ASHP operation to times when the weather is warmer. It may also take advantage of time of use electricity rates and support defrosting when necessary. The evaluation of ASHP-TES systems, however, is still limited because traditional metrics do not capture their full economic and environmental benefits. In this work, a python framework is presented to model the ASHP with and without the presence of TES. Metrics are proposed to analyze the system performance in terms of costs, equivalent CO2 emission, and efficiency metrics to evaluate and compare alternative systems. Model validation against experimental data obtained for a commercial heat pump is provided, as well as an application example using Denver, Colorado, to highlight the model capabilities.

cold climate↗