Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Balloon”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,171 records · Page 65

VolKilau: Volcano Rapid Response Balloon Campaign During the 2018 Kilauea Eruption

After nearly 35 years of stable activity, the Kilauea volcanic system in Hawaiʽi, went through sudden changes in May 2018 with the emergence of 20 volcanic fissures along the Lower Eastern Rift Zone(LERZ) destroying 700 homes in Leilani Estates and forcing more than 2000 people to evacuate. Volcanic emissions lasted for several months between June and September 2018 leading to low visibility and poor air quality in Hawaiʽi and across the Western Pacific. The NASA-funded VolKilau mission was rapidly mounted and conducted between 11-18 June 2018 to: i) Profile volcanic emissions with SO2and aerosol measurements, ii) Validate satellite observations and iii) Be prepared for the next large volcanic eruption. Through a series of balloon-borne measurements with tethered and free released launches, we measured SO2 concentration, aerosol concentration and optical properties 60 to 80km downwind from the volcanic fissures using gas sensors, optical particle counters, backscatter sondes, and an aerosol impactor. While most of measurements made during the Kilauea eruption were ground-based, the VolKilau mission represented a unique opportunity to characterize plume properties, constrain emission profiles, study early chemistry involving the conversion of SO2 into sulfuric acid and understand the influence of water clouds in the removal of SO2. Our team continues to be better prepared for deploying in the event of a major volcanic eruption

J-P Vernier↗

EXCLAIM: A New Balloon Mission to Map the Cosmological History of Galaxies

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity mapping approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (micro-spec) coupled to microwave kinetic inductance detectors (MKIDs). I will present an overview of the EXCLAIM instrument design and status.

Eric Switzer↗

SAGE III/ISS Validation of Ozone and Water Vapor V5.2 Data Using Collocated Balloon-Borne Measurements

The Stratospheric Aerosol and Gas Experiment III (SAGE III) instrument installed on the International Space Station (ISS) has completed nearly four years of data collection and production of science data products. The SAGE III/ISS is a solar and lunar occultation instrument that scans the light from the Sun and Moon through the limb of the Earth’s atmosphere to produce vertical profiles of aerosol, ozone, water vapor, and other trace gases. It continues the legacy of previous SAGE instruments dating back to the 1970s to provide data continuity of stratospheric constituents critical for assessing trends in the ozone layer. This presentation shows the validation results of comparing SAGE III/ISS ozone and water vapor vertical profiles from the newly released v5.2 science product with those of balloon launched ozonesonde and frost point hygrometer measurements and satellite data from the Microwave Limb Sounder.

S Kizer↗

Balloon Flight for NephEx: A Nephelometer for Probing Planetary Atmospheres

NephEx (Nephelometer Experiment) was successfully tested in a weather balloon flight by Raven Aerostar, North Dakota in June 2021.The flight took in-situ measurements and recorded data from launch to >20 km and during all of descent(Figure 1). The flight data successfully detected super-cirrus clouds up to altitudes of 15 km and boundary layer haze. Successful testing of this instrument has brought the instrument to TRL-5 status. NephEx is capable of making direct measurement of clouds on other planets, size of particles and their concentration.

V Jha↗

Parallel plate capacitor TiN KID array development for the Balloon Experiment for Galactic Infrared Science

The Balloon Experiment for Galactic Infrared Science (BEGINS) will map dust spectral energy distributions (SEDs) between 25 and 250 microns near high-mass star regions, characterizing the radiation fields and dust properties of a variety of stellar environments. To accomplish these goals, BEGINS will be outfitted with roughly 1,800 titanium nitride (TiN), superconducting kinetic inductance detectors (KIDs). A parallel plate capacitor KID design is used to achieve high pixel density arrays. A cryogenic, silicon-based, metal-mesh linear variable filter will define detector band passes across the KID array. Optical coupling to the filters and telescope will be accomplished using silicon microlenses. Here we present laboratory characterization of prototype BEGINS detector arrays, describe future array development plans, and describe the testbed used to characterize the arrays.

Nicholas F. Cothard↗

SuperHERO X-ray Telescope Balloon Mission

The SuperHERO hard X-ray telescope will observe extended sources at unprecedented imaging resolution, revealing the origins of non-thermal emission in extreme astrophysical environments. Employing NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon platform, SuperHERO consists of seven identical, co-aligned telescopes with a combined effective area of 45 cm² at 30 keV. SuperHERO was selected in the APRA 2023 call as a five-year mission, with an inaugural two-day flight scheduled from Fort Sumner, New Mexico, in the fall of 2028. For its initial target, SuperHERO will observe the Crab pulsar wind nebula, localizing hard X-ray emission. Mission development is currently underway, with updates and status to be provided in this presentation.

Nick Thomas↗

Initial Results from the ANITA 2006-2007 Balloon Flight

We report initial results of the Antarctic Impulsive Transient Antenna (ANITA) 2006-2007 Long Duration Balloon flight, which searched for evidence of the flux of cosmogenic neutrinos. ANITA flew for 35 days looking for radio impulses that might be due to the Askaryan effect in neutrino-induced electromagnetic showers within the Antarctic ice sheets. In our initial high-threshold robust analysis, no neutrino candidates are seen, with no physics background. In a non-signal horizontal-polarization channel, we do detect 6 events consistent with radio impulses from extensive air showers, which helps to validate the effectiveness of our method. Upper limits derived from our analysis now begin to eliminate the highest cosmogenic neutrino models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Balloon flight and atmospheric electricity

The air is known to be charged with electricity (chiefly positive) with reference to the earth, so that its potential increases with the altitude and the difference in potential between two points in the same vertical line, divided by the distance between them, gives a value called the "potential gradient," which may vary greatly with the altitude, the nature of the ground and the atmospheric conditions.

BALLOON FLIGHTS↗

MASA's Ultra-Long Duration Balloon Project - Teaching an Old Dog New Tricks

The leviathan silently slides through the upper atmosphere of the blue planet, its eye steadily staring into the cold, dark recesses of deep space. Periodically the eye looks at different points in the blackness while processing the information it sees.

balloons aerobots solar system exploration stratos↗

Changes in Prostate Shape and Volume and Their Implications for Radiotherapy After Introduction of Endorectal Balloon as Determined by MRI at 3T

Purpose: To determine the changes in prostate shape and volume after the introduction of an endorectal coil (ERC) by means of magnetic resonance imaging (MRI) at 3T. Methods and materials: A total of 44 consecutive patients with biopsy-proven prostate cancer underwent separate MRI examinations at 3T with a body array coil and subsequently with an ERC inflated with 50 mL of fluid. Prospectively, two experienced readers independently evaluated all data sets in random order. The maximal anteroposterior, right-to-left, and craniocaudal prostate diameters, as well as the total prostate and peripheral zone and central gland volumes were measured before and after ERC introduction. The changes in prostate shape and volume were analyzed using Wilcoxon's test for paired samples. Results: The introduction of the ERC significantly changed the prostate shape in all three directions, with mean changes in the anteroposterior, right-to-left, and craniocaudal diameters of 15.7% (5.5 mm), 7.7% (3.5 mm), and 6.3% (2.2 mm), respectively. The mean total prostate, peripheral zone, and central gland volume decreased significantly after ERC introduction by 17.9% (8.3 cm{sup 3}), 21.6% (4.8 cm{sup 3}), and 14.2% (3.4 cm{sup 3}), respectively. Conclusion: ERC introduction as observed by 3T MRI changed the prostate shape and volume significantly. The mean anteroposterior diameter was reduced by nearly one-sixth of its original diameter, and the mean total prostate volume was decreased by approximately 18%. This could cause difficulties and should be considered when using ERC-based MRI for MRI-computed tomography fusion and radiotherapy planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prospective Multicenter Trial Evaluating Balloon-Catheter Partial-Breast Irradiation for Ductal Carcinoma in Situ

Purpose: To determine outcomes of accelerated partial-breast irradiation (APBI) with MammoSite in the treatment of ductal carcinoma in situ (DCIS) after breast-conserving surgery. Methods and Materials: We conducted a prospective, multicenter trial between 2003 and 2009. Inclusion criteria included age >18 years, core needle biopsy diagnosis of DCIS, and no prior breast cancer history. Patients underwent breast-conserving surgery plus MammoSite placement. Radiation was given twice daily for 5 days for a total of 34 Gy. Patients were evaluated for development of toxicities, cosmetic outcome, and ipsilateral breast tumor recurrence (IBTR). Results: A total of 41 patients (42 breasts) completed treatment in the study, with a median follow up of 5.3 years. Overall, 28 patients (68.3%) experienced an adverse event. Skin changes and pain were the most common adverse events. Cosmetic outcome at 6 months was judged excellent/good by 100% of physicians and by 96.8% of patients. At 12 months, 86.7% of physicians and 92.3% of patients rated the cosmetic outcome as excellent/good. Overall, 4 patients (9.8%) developed an IBTR (all DCIS), with a 5-year actuarial rate of 11.3%. All IBTRs were outside the treatment field. Among patients with IBTRs, the mean time to recurrence was 3.2 years. Conclusions: Accelerated partial-breast irradiation using MammoSite seems to provide a safe and cosmetically acceptable outcome; however, the 9.8% IBTR rate with median follow-up of 5.3 years is concerning. Prospective randomized trials are necessary before routine use of APBI for DCIS can be recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of 3-Dimensional Planning Techniques Using an Intravaginal Multichannel Balloon Applicator for High-Dose-Rate Gynecologic Brachytherapy

Purpose: To study the dosimetric differences of various channel combinations of the Capri vaginal applicator. Methods and Materials: The Capri consists of a single central channel (R1), an inner array of 6 channels (R2), and an outer array of 6 channels (R3). Three-dimensional plans were simulated for 6 channel arrangements (R1, R2, R12, R13, R23, and R123). Treatment plans were optimized to the applicator surface or 5-mm depth while minimizing dose to organs at risk (OARs: bladder, rectum, sigmoid, and urethra). The clinical target volume (CTV) was defined as a 5-mm circumferential shell extending 4 cm in length around the applicator. Clinical target volume coverage (D{sub mean}, D{sub 90}, V{sub 100}, and V{sub 150}) and OAR doses (D{sub 0.1} {sub cm{sup 3}}, D{sub 1} {sub cm{sup 3}}, D{sub 2} {sub cm{sup 3}}, and D{sub mean}) were compared. A comparison between the Capri (R123) and a conventional single-channel applicator was also done. Statistical significance (P value <.05) was evaluated with a 2-tailed t test. Results: When prescribing to 5-mm depth, CTV coverage using all 13 channels (R123) versus a single channel (R1) was similar; however, when prescribing to the surface there were differences (P<.0001) in all CTV metrics except for the V{sub 150}. The R1 plans had higher doses to all OARs compared with R123 plans (P<.007). Doses to OARs were not significantly different between R23 and R123 plans (P=.05-.95), and CTV coverage differences were on the order of 1%. Capri R123 plans provided slightly lower CTV D{sub 90} and D{sub mean} but equivalent OAR doses with smaller standard deviations compared with conventional cylinder plans for both prescriptions. Conclusions: The Capri multichannel applicator provides equivalent target coverage at 5-mm depth, with significantly reduced dose to OARs relative to using a single channel. Optimal plans can be achieved using R12 (lowest V{sub 150}) or R123 or R23 (lowest OAR doses)

62 RADIOLOGY AND NUCLEAR MEDICINE↗